| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹18.9 L+₹70,130 (3.86%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹19.4 L+₹1.2 L (6.72%)Rejected-AOC 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹19.9 L+₹1.7 L (9.59%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹20.5 L+₹2.4 L (12.9%)Rejected-AOC KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
15 Apr 2022, 6:00 pmClosed
CWE ARMY BANGALORE
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
SPECIAL REPAIR REPLACEMENT OF UG CABLE, MCCBs, LT PANEL ETC WITH SOME WATER SUPPLY WORKS AT 1 ATC, 2 ATC AND ASC CENTRE AND COLLEGE AREA WITH OTHER AREA UNDER GE CENTRAL BANGALORE
2022_MES_514219_1
86118/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
BANGALORE
AS PER TENDER
8 documents required · 8 mandatory
₹500
Yes
GE (CENTRAL) BANGALORE
₹32,000
Yes
HQ CWE ARMY BANGALORE
7 May 2022
17 Mar 2022
18 Apr 2022
17 Mar 2022
15 Apr 2022
1 Apr 2022
17 Mar 2022 - 24 Mar 2022
25 Mar 2022
Amount
Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc. and keeping Serviceable Materials in Safe Custody for Re-use, complete all as directed.
Dismantling Insulators from Poles of any description and any size including keeping Serviceable Materials in Safe Custody for Re-use, complete all as directed.
Dismantling ACSR or AAC Conductors from the disturbed Span including Line Spacer, etc. including keeping Serviceable Materials in Safe Custody for Re-use, complete all as directed.
Excavation in trenches in soft / loose soil n . exc 1.5 mtrs wide and not exceeding 1.5 mtrs depth for taking out / laying of under ground cables / erection of poles complete all as directed.
Excavation in trenches exc 1.5 m wide and exc 1.5m in depth for foundation of pole in any type of soil complete all as directed.
Returning, filling in, including spreading levelling and well ramming in layers not exc 25 cm with excavated soil complete all as directed.
Removing surplus spoil to a distance not exc 50mtrs away and depositing at a level not exc 1.5 mtrs above the starting point complete all as directed.
M&L for sand coarse filling in trenches obtained from local river for cushioning of UG cable complete all as directed. Note : Punned thickness of sand layer shall be considered for the purpose of payment
Supply and lay common burnt old size bricks of sub class B laid at right angle on the cable in trenches for cable protection complete all as directed.
Supply laying & testing XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 120 Sqmm 3.5 core complete all as specified and as directed.
Supply laying & testing XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 95 Sqmm 3.5 core complete all as directed.
Supply laying & testing XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 70 Sqmm 3.5 core complete all as directed.
Supply laying & testing XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 25 Sqmm 3.5 core complete all as directed.
Supply laying & testing XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 16 Sqmm 4 core complete all as directed.
Supply and fixing GI tubing light grade 80 mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor /wall complete including taking out if required all as specified and directed . ( Note for item no 15 and 16 :- Excavation / earth work , MS clamp, nuts and bolts shall be measured and paid separately under relevant items of Sch ‘A’ complete all as directed.
Supply and fixing GI tubing light grade 50 mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor /wall complete including taking out if required all as specified and directed .
M&L for boring of holes under roads,pavements,hard standing by manual for 80 mm to 25 mm dia pipe complete all as directed.
Supply, fabrication, installation and testing of LT out door type factory made(CPRI Approved ), junction box of size 900mm(H)X700mm(B)X400mm(W) (over all dimension ) made out of 3.15mm thick CRCA sheet duly supported with mild steel angle iron of size 40X40X5 mm frame, 04 Nos aluminium bus bar of capacity 250 Amps with drilled hole for incoming/outgoing cable connection with necessary aluminium lungs, GI nuts bolts and washer including 08 Nos bridge insulator DMC , heavy duty, suitable for 3 Phase 4 wire system, one danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull & bones in signal red colour and fixed in front door size and PCC (1:3:6) type C-2 foundation 0.30m above normal ground level & 0.30m below ground level with necessary exacavation and earth work and painting to internal and external steel surface with powder coated (Siemens gray) RL-35 after neccesary preparation of surfaces including Indicating lamp LED type 240V 50 Hz AC -one set of 3.
M&L for installation, commissioning and testing Double Door Panel board (CPRI approved) with canopy head out door cubical type panel board of over all min dimension 0.80 m (L) X 1.00m (H) X 0.50m (W) fabricated with 3.15mm thick CRCA sheet on mild steel angle iron 50X50X6 mm thick frame, totally enclosed type dust & vermin proof back side open-able fixed with hinged shutter and front side open-able with hinged shutter and locking arrangement for individual MCCBs/MCBs , powder coated finished both internally and externally suitable for 415Volt AC 50 Hz 3 Phase 4 wire system by means of Alluminum bus bar of 250 Amps Capacity (Main bus bar ) and 350 Amps Loop Bus bar with coloured insulating tape/sleeves mounted on porcelain or synthetic insulators with provision for fixing MCCBs/MCBs necessary inter connections with Aluminium bar/strip duly coloured code insulation and providing under mentioned equipments & accessories including connections of all out going/in coming existing/New cables of size different size and including PCC foundation of 0.5 mtrs height complete all as directed. (a) I/C MCCB 4 pole 160Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals - 01No complete all as directed. (b) O/G MCCB 4 pole 63 Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -07 Nos complete all as directed. (c) O/G MCB TPN 63Amp, 10KA,C curve - 02 Nos complete all as directed. (d) Indicating lamp LED type 240V 50 Hz AC -one set of 3 complete all as directed.
M&L for installation, commissioning and testing Double Door Panel board (CPRI approved) with canopy heade out door cubical type panel board of over all min dimension 0.80 m (L) X 1.00m (H) X 0.50m (W) fabricated with 3.15mm thick CRCA sheet on mild steel angle iron 50X50X6 mm thick frame, totally enclosed type dust & vermin proof back side open-able fixed with hinged shutter and front side open-able with hinged shutter and locking arrangement for individual MCCBs/MCBs , powder coated finished both internally and externally suitable for 415Volt AC 50 Hz 3 Phase 4 wire system by means of Alluminum bus bar of 250 Amps Capacity (Main bus bar ) and 350 Amps Loop Bus bar with coloured insulating tape/sleeves mounted on porcelain or synthetic insulators with provision for fixing MCCBs/MCBs necessary inter connections with Aluminium bar/strip duly coloured code insulation and providing under mentioned equipments & accessories including connections of all out going/in coming existing/New cables of size different size and including PCC foundation of 0.5 mtrs height complete all as directed. (a) I/C MCCB 4 pole 250 Amp,Icu=Ics=36KA, Adjustable thermal and adjustable Magnetic setting with extended terminals - 01No complete all as directed. (b) O/G MCCB 4 pole 200 Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals - 03 Nos complete all as directed. (c) O/G MCCB 4 pole 63 Amp,Icu=Ics=16KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -01 Nos complete all as directed. (d) O/G MCCB 4 pole 63 Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals -01 Nos complete all as directed. (e) Indicating lamp LED type 240V 50 Hz AC -one set of 3 complete all as directed.
M&L for Earthing of machinery/ equipment installed at power house /substation, using Galvanised Iron earth plate eletcrode of size 600 x 600 x6 mm thick as buried directly in ground (earth pit not less than 3mtr below normal ground level connected to GI earth strip 32 mm x 6 mm thick by means of bolts nuts,check nuts and washers at complete etc all as shown in electrical plate No-3 of SSR part-1 connected to earthing test point all as specified or indicated including PCC pit (1:3:6) type C-1 with 50mm thick pre cast RCC (1:1½ :3) nominal mix cover slab reinforced with 8mm dia mild steel bar including necessary excavation and earth work in soft/loose soil and disposal of spoil to a distance n.exc 50mtr and funnel with watering pipe wire mesh GI protection pipe 40 mm bore including testing complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches/fixing on wall/floor GI pipe water tubing medium grade with all fittings, including testing complete for the following all as directed.
(a) 50mm bore tube
(b) 25mm bore tube
Supply and fixing in gun metal /globe/gate valve, with iron wheel head, screwed both ends for iron pipe and fixed complete all as directed for the following pipes :-
(a) 50 mm bore
(b) 25mm bore
S&F brass float valve with PVC for 25mm pipe complete all as directed.
RAMSON TRADERS
G K CONSTRUCTIONS
kamadhenu Electricals
GS TRADERS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .