| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 CrAccepted-AOC | ₹3.8 Cr | L1 | Accepted-AOC Lowest tender |
| 2 | L2₹4.0 Cr+₹17.1 L (4.45%)Rejected-Finance 21 PASCHIM VIHAR EXTENSION NEW DELHI 110 063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹4.0 Cr+₹17.1 L (4.45%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹4.7 Cr+₹85.5 L (22.3%)Rejected-Finance | ₹4.7 Cr+₹85.5 L (22.3%) | L3 | Rejected-Finance Other than lowest |
Tender Value
₹4.3 Cr
EMD Value
₹5.0 L
Closing Date
30 May 2022, 6:00 pmClosed
Chief Engineer
HQ CE Delhi Zone Delhi Cantt-10
PROVN OF STP OF DIFFERENT CAPACITIES INCL CONNECTED PIPING and PLUMBING WORKS FOR EFFICIENT USE OF TREATED SPT WATER IN DELHI CANTT UNDER GE (U) WATER SUPPLY DELHI CANTT-10
2022_MES_517637_1
CA NO CEDZ/TOKEN-16 of 2022
Open Tender
Civil Works
Lump-sum
270 days
Delhi Cantt
MES contractor enlisted in MES under class A cat c vii having deposited Standing Security of Rs 700000.00 with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
10 documents required · 10 mandatory
₹2,000
GE (U) Water Supply
₹5.0 L
Yes
12 Jul 2022
11 Apr 2022
1 Jun 2022
11 Apr 2022
30 May 2022
16 May 2022
Amount
Total amount of Sch 'A' Part - I (Construction of Pump House Building complete all as specified shown on drawing.)
Total amount of Sch 'A' Part-II (Excavation & Earth Work) (Ref pre priced Schedule attached seperately)
Total amount of Revised Sch 'A' Part-III (Internal Electric Supply) (Ref pre priced Schedule attached seperately)
Total amount of Sch 'A' Part-IV (Internal Water Supply) (Ref pre priced Schedule attached seperately)
Total amount of Sch 'A'Part-V (External Electric Supply) (Ref pre priced Schedule attached seperately)
Total amount of Sch 'A'Part-VI (External Water Supply) (Ref pre priced Schedule attached seperately)
Total amount of Sch 'A'Part-VII (Road Path and Culvert) (Ref pre priced Schedule attached seperately)
Total amount of REVISED Sch 'A'Part-VIII (Sewage Disposal) (Ref pre priced Schedule attached seperately)
Total amount of REVISED Sch 'A'Part-IX (Boundary Wall and Gate/ Fencing) (Ref pre priced Schedule attached seperately)
Description of Work / Item(s)
Amount
STP(SEWAGE TREATMENT PLANT) Designing, Supply, installation, testing and commssioning of Sewage Treatment Plant of capacity 300 KLD including all civil works, treated water tank of 100000 Ltr capacity, electrical and mechanical works for STP having following input and output parameters: (a) Inlet Parameter (i) BOD - 250-300 mg/ltr (ii) COD - 400-500 mg/ltr (iii) TSS - 250-300 mg/ltr (iv) Oil & Grease - 20-30 mg/ltr (v) pH - 6 to 9 (vi) Coliform - 1 x 10 6 MPN/100ML (vii) Peak Factor - 3.0 (b) outlet parameter of sewage treated water are as follows : (i) BOD < 10 mg/ltr (ii) COD < 30 mg/ltr (iii) TSS < 10 mg/ltr (iv) Oil & Grease < 10 mg/ltr (v) pH - 6.5 to 8.5 (vi) Coliform - 1000 MPN/100ML (vii) Residual Chlorine - > 0.5 mg/ltr (viii). Nitrogen < 10 mg/Ltrs (ix). Phosphours < 1 mg/Ltrs
Designing, Supply, installation, testing and commssioning of package type Sewage Treatment Plant of capacity 100 KLD including all civil works, treated water tank, electrical and mechanical works for STP having following input and output parameters: (a) Inlet Parameter (i) BOD - 250-300 mg/ltr (ii) COD - 400-500 mg/ltr (iii) TSS - 250-300 mg/ltr (iv) Oil & Grease - 20-30 mg/ltr (v) pH - 6 to 9 (vi) Coliform - 1 x 10 6 MPN/100ML (vii) Peak Factor - 3.0 (b) outlet parameter of sewage treated water are as follows : (i) BOD < 10 mg/ltr (ii) COD < 30 mg/ltr (iii) TSS < 10 mg/ltr (iv) Oil & Grease < 10 mg/ltr (v) pH - 6.5 to 8.5 (vi) Coliform - 1000 MPN/100ML (vii) Residual Chlorine - > 0.5 mg/ltr (viii). Nitrogen < 10 mg/Ltrs (ix). Phosphours < 1 mg/Ltrs
Notes :- (i) The STPs should be designed as such that the stilling chamber, Bar Screen Chamber, Oil Grease Trap Chamber, EqualizationTank and Treated water tank should be in RCC M-30. (ii) The MBBR tanks, Tube settler tank. Chlorine Contact tank, filter feed tankand sludge holding tank should be Mild steel epoxy painted (MSEP) not less than 5mm thick sheet. The package type structure should be designed such that it fits in the space allocated. the tenderer is required to visit and access the site, no claims after acceptance should be entertained here-in-after. (iii) The STPs desinged should be vetted adn approved by IIT/NIT. The process flow, process and instrumentation, Architectural and structural drawing alongwith design calculations i.e. complete designed STP by OEM should be vetted and approved by NIT/IT.
EXTERNAL ELECTRIC SUPPLY Supply, Installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 450mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 200 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, the degree of protection is IP-54. the panel shall be complete with instrumentation such as and CT's, including extended aluminium strip of rating of Incomer (100Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable dismantled before etc., and comprising of the following:-
(a) MCCB 63 amps, 4 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 01 Nos (Incomer) (b) MCCB 40 amps, 4 pole with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 02 Nos(outgoing) (c) MCB C series type TPN 32 AMP - 03 Nos (c) Multifunctional meter Cat No WL404020OOOO MAKE L&T (d) Indicator lamp RYB :01 Set (e) CT'S 100/5 01 Set Make-L&T/AE/Shanti (f). Change over switch on load type 4 pole, 3 phase of capacity 63 Amps
Supply, Installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 450mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 200 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, the degree of protection is IP-54. the panel shall be complete with instrumentation such as and CT's, including extended aluminium strip of rating of Incomer (100Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable dismantled before etc., and comprising of the following:-
(a) MCCB 100 amps, 4 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 01 Nos (Incomer) (b) MCCB 40 amps, 4 pole with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 04 Nos(outgoing) (c) MCB C series type TPN 63 AMP - 03 Nos (c) Multifunctional meter Cat No WL404020OOOO MAKE L&T (d) Indicator lamp RYB :01 Set (e) CT'S 200/5 01 Set Make-L&T/AE/Shanti (f). Changeover switch on load type 4 pole 3 phase of capacity 100 Amps
Supply, Installalation and testing of water cooled Diesel Engine driven Prime duty Generating Set of net capacity after all derating factors net of not less than 40KVA /32 KW ,50Hz 415 volt 3 phase, 4 wire,0.8 lagg, minimum Required Power for Rated kVA (hp) along with AMF system with Acoustic Enclosure exhaust silencer-residential in line , as per the noise emmission standards liad down by MoEF / CPCB Norms.
A) Engine comprising of the following: Rugged engine natural liquid cooled (EG Compleat 50:50) with radiator as secondary media with world class OEM Engines for powered diesel generator set along with these specifications of Advanced in-cylinder technology turbo charged , air cooled aspriated to meet latest emission norms without any after-treatment device. Class defining technology engine is designed to meet stringent exhaust emission tests as per revised MoEF norms, thus offering environment friendly powe Compact in size with optimum power to weight ratio, 3/4 cylinder, In-line 4 stroke, radiator cooled engine Well designed air handling system with Dry type, heavy duty, replaceable paper element aircleaner with restriction indicator, Air to air aftercooling, Optimised turbocharger for increased altitude capabilities, Best in class fuel economy with Inline fuel pump with A1 class mechanical governing, Spin on fuel filter, Standard integral set-mounted radiator system, designedand tested for 50°C ambient temperature,Full flow spin on lube oil filte,First fill of lube oil and coolant, Electrical starter motor with soft start engagement feature, Battery charging alternator,1 x 12 V DC battery/Alternator
b) Alternator PMG type comprising of the following: Stamford UC/jyothi/crompton alternator frames from Technologies Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-13 Phase reconnectable winding with 12 terminals brought out for connection Dedicated winding specially designed for 1 phase and 3 phase operation Better motor starting capability Best in class efficiency Compact design with sealed bearings for longer life and lesser maintenance Impregnation on all wound components for better mechanical strength with Alternator of IP 23, Voltage regulation (Max.)±1%, Class of Insulation H Class, Winding Pitch 2/3,Stator Winding Double layer lap Rotor Dynamically Balanced, Waveform distortion/ Total Harmonic Distortion No load < 1.5 %, Non distorting balanced linear load < 5 %,Maximum Unbalanced Load across phases# less than or equal to 25%, Telephonic Harmonic factor < 2% alternator capacity output shall not be less than 40 KVA / 32 KW ,50Hz 415 volt 3 phase, 4 wire,0.8 lagg.
Control Panel comprising of the following: c) AMF / Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish.The control panel consists of the following parts of makes as per OEM recomendation: microprocessor based generator set monitoring and control system. along with AMF Functionality is inbuilt and this control includes an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration, and diagnostics, Copper bus bars with suitable capacity with incoming/outgoing terminals, Indicating lamps for ‘Load ON’ and ‘Set Running’,Instrument fuses / MCBs duly wired and ferruled, Circuit breakers of suitable rating with overload and shortcircuit protections. with motorised change overs /on load power contactors with copper busbars, cables and protective acessories with load / bypass arrangements
Resednetial type silencer Critical grade silencer suitably optimized to meet stringentnoise emission standards laid down by MoEF / CPCBalong with MS supporting structures .along with thermal Insulation on horizontal pipe with Mineral Wool/ Asbestos Rope 50mm Thick wire mesh and 26 gauge aluminium cladding (12")
d) Controller should be compatable to the following specifications: (i)AMF Functionality controllers of Makes from the OEM. (II) Intuitive operator interface which includes LED backlit128X64 pixel graphic display with tactile feel soft-switches.Indications - Generator set, Utility Status Lamp. (iii)Remote start-stop with Engine Metering: Oil pressure, Engine temperature, Startingbattery voltage, Engine running hours (iv)AC Alternator Metering: L-L Voltage and L-N Voltage,Current (phase and total), kVA (phase and total) andFrequency. kwh, Total & per phase (kw & kVA), PF, UtilityVoltage and Freq. (v)Engine Protection: Low lube oil pressure, High/Low coolanttemperature, Battery Over/Under/Weak Volts, Fail to Crank/Start, Sensor failure, Cranking lockout, Low fuel level. (vi)AC Alternator Protection: Over/Under Voltage, Over/UnderFrequency, Loss of AC sensing. Overspeed, Over Current. (vii)Data Logging: Engine hours, Control hours and upto 5 recent fault codes (viii)Configurable glow plug control, Cycle Cranking (ix)12/24 Volt DC operation,Sleep mode,Modbus interface (RS485 RTU),InPower compatible (PC based service tool),Certifications - meets the requirement of relevant ISO, EN,Mil Std. and CE standards (e)Maintenance due alarm based on Engine Run Time and duedate,Exercisor scheduler (f) Remote HMI, Digital electronic governor with temperture compensation and smooth starting, digital AVR for shunt of PMG excitor with Torque monitoring
(g) All pipe line connections, valves etc.required for the lube oils, fuel and cooling system
(h) Battery & Battery charger of rated capacity as per the alternator/ Engine compatability
(j) Mounting Arrangement shall be of the following: (i) Engine and alternator are mounted on a common MSfabricated base frame with AVM pads. (ii) Base frame with integral fuel tank is provided with drainplug, air vent, inlet and outlet connection, level indicator andprovision for cleaning
(k) Fuel Tank of capacity 12 hrs running capacity along with Fuel pipe MS c class 25mm ID with bends , flanges , valves, tees and bends.
(l) Residnetial type silencer with MS pipe as designed by the OEM horizontal Exhaust pipe complete with bends and flanges of adeeaquate length not less than 10 Mtr.along with thermal Insulation on horizontal pipe with Mineral Wool/ Asbestos Rope 50mm Thick wire mesh and 26 gauge aluminium cladding (12")
(m) Controll / service cables shall be of 4cx 2.5 sqmm, 24 c x 2.5 sqmm , 2 c x 2.5 sqmm, and 8c x 0.75 sqmm shielded control cables ,pvc insulated copper armoured, controll panel for auxilaries with starters for pumps,heaters etc
(n) RCC foundation with necessary earth work ,PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, filling and mass concrete / RCC M-30 (20 mm graded aggregate) as in foundations, Plinth beam along with necessary form work / TMT bars of 10mm dia and over cut to length bend to shape required including cranking, bending, spirally for hooping for columns, hooking ends and bidning with and including MS wire (annealed) not less than 0.9mm dia securing with clips / 10 mm thick plastering on fair faces of brick work or concrete surface in CM (1:6),even and smooth without using extra cement / Sand filling in layers around the foundation including watering and consolidation as per OEM dimensions
(o) Acoustic Enclosure shall comprise of the following (i) Specially designed to meet stringent MoEF/ CPCB norms/as per new Guidelines of Delhi NCR at 75% load under free field conditions (ii) The Acoustic Enclosure as per CPCB Norms is made of CRCA sheets in Munselgreen shade and a structural/ sheet metal base frame painted in black. or any other standard colour as specified by the OEM (iii) High quality noise absorbant and fire-retardant gradeacoustic insulation material (P.U. Foam) complying to IS8183 designed to have optimum serviceability (iv) Air inlet louvers specially designed to operate at rated load, Made on special purpose CNC machines for consistency inquality and workmanship (v) 11 tank pretreatment process and UV resistant powdercoating of all parts to withstand extreme environment, Use of special hardware for longer life, Flush styling - no projections, Fluid drains for lube oil and fuel,Fuel filling arrangement inside the enclosure
Supply, Installalation and testing of water cooled Diesel Engine driven Prime duty Generating Set of net capacity after all derating factors net of not less than 20 KVA /15 KW ,50Hz 415 volt 3 phase, 4 wire,0.8 lagg, minimum Required Power for Rated kVA (hp) along with AMF system with Acoustic Enclosure exhaust silencer-residential in line , as per the noise emmission standards liad down by MoEF / CPCB Norms.
A) Engine comprising of the following: Rugged engine natural liquid cooled (EG Compleat 50:50) with radiator as secondary media with world class OEM Engines for powered diesel generator set along with these specifications of Advanced in-cylinder technology turbo charged , air cooled aspriated to meet latest emission norms without any after-treatment device. Class defining technology engine is designed to meet stringent exhaust emission tests as per revised MoEF norms, thus offering environment friendly powe Compact in size with optimum power to weight ratio, 3/4 cylinder, In-line 4 stroke, radiator cooled engine Well designed air handling system with Dry type, heavy duty, replaceable paper element aircleaner with restriction indicator, Air to air aftercooling, Optimised turbocharger for increased altitude capabilities, Best in class fuel economy with Inline fuel pump with A1 class mechanical governing, Spin on fuel filter, Standard integral set-mounted radiator system, designedand tested for 50°C ambient temperature,Full flow spin on lube oil filte,First fill of lube oil and coolant, Electrical starter motor with soft start engagement feature, Battery charging alternator,1 x 12 V DC battery/Alternator
b) Alternator PMG type comprising of the following: Stamford UC/jyothi/crompton alternator frames from Technologies Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-13 Phase reconnectable winding with 12 terminals brought out for connection Dedicated winding specially designed for 1 phase and 3 phase operation Better motor starting capability Best in class efficiency Compact design with sealed bearings for longer life and lesser maintenance Impregnation on all wound components for better mechanical strength with Alternator of IP 23, Voltage regulation (Max.)±1%, Class of Insulation H Class, Winding Pitch 2/3,Stator Winding Double layer lap Rotor Dynamically Balanced, Waveform distortion/ Total Harmonic Distortion No load < 1.5 %, Non distorting balanced linear load < 5 %,Maximum Unbalanced Load across phases# less than or equal to 25%, Telephonic Harmonic factor < 2% alternator capacity output shall not be less than 20 KVA / 16 KW ,50Hz 415 volt 3 phase, 4 wire,0.8 lagg.
Control Panel comprising of the following: c) AMF / Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish.The control panel consists of the following parts of makes as per OEM recomendation: microprocessor based generator set monitoring and control system. along with AMF Functionality is inbuilt and this control includes an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration, and diagnostics, Copper bus bars with suitable capacity with incoming/outgoing terminals, Indicating lamps for ‘Load ON’ and ‘Set Running’,Instrument fuses / MCBs duly wired and ferruled, Circuit breakers of suitable rating with overload and shortcircuit protections. with motorised change overs /on load power contactors with copper busbars, cables and protective acessories with load / bypass arrangements
Resednetial type silencer Critical grade silencer suitably optimized to meet stringentnoise emission standards laid down by MoEF / CPCBalong with MS supporting structures .along with thermal Insulation on horizontal pipe with Mineral Wool/ Asbestos Rope 50mm Thick wire mesh and 26 gauge aluminium cladding (12")
d) Controller should be compatable to the following specifications: (i)AMF Functionality controllers of Makes from the OEM. (II) Intuitive operator interface which includes LED backlit128X64 pixel graphic display with tactile feel soft-switches.Indications - Generator set, Utility Status Lamp. (iii)Remote start-stop with Engine Metering: Oil pressure, Engine temperature, Startingbattery voltage, Engine running hours (iv)AC Alternator Metering: L-L Voltage and L-N Voltage,Current (phase and total), kVA (phase and total) andFrequency. kwh, Total & per phase (kw & kVA), PF, UtilityVoltage and Freq. (v)Engine Protection: Low lube oil pressure, High/Low coolanttemperature, Battery Over/Under/Weak Volts, Fail to Crank/Start, Sensor failure, Cranking lockout, Low fuel level. (vi)AC Alternator Protection: Over/Under Voltage, Over/UnderFrequency, Loss of AC sensing. Overspeed, Over Current. (vii)Data Logging: Engine hours, Control hours and upto 5 recent fault codes (viii)Configurable glow plug control, Cycle Cranking (ix)12/24 Volt DC operation,Sleep mode,Modbus interface (RS485 RTU),InPower compatible (PC based service tool),Certifications - meets the requirement of relevant ISO, EN,Mil Std. and CE standards (e)Maintenance due alarm based on Engine Run Time and duedate,Exercisor scheduler (f) Remote HMI, Digital electronic governor with temperture compensation and smooth starting, digital AVR for shunt of PMG excitor with Torque monitoring
(g) All pipe line connections, valves etc.required for the lube oils, fuel and cooling system
(h) Battery & Battery charger of rated capacity as per the alternator/ Engine compatability
(j) Mounting Arrangement shall be of the following: (i) Engine and alternator are mounted on a common MSfabricated base frame with AVM pads. (ii) Base frame with integral fuel tank is provided with drainplug, air vent, inlet and outlet connection, level indicator andprovision for cleaning
(k) Fuel Tank of capacity 12 hrs running capacity along with Fuel pipe MS c class 25mm ID with bends , flanges , valves, tees and bends.
(I) Residnetial type silencer with MS pipe as designed by the OEM horizontal Exhaust pipe complete with bends and flanges of adeeaquate length not less than 10 Mtr.along with thermal Insulation on horizontal pipe with Mineral Wool/ Asbestos Rope 50mm Thick wire mesh and 26 gauge aluminium cladding (12")
(m) Controll / service cables shall be of 4cx 2.5 sqmm, 24 c x 2.5 sqmm , 2 c x 2.5 sqmm, and 8c x 0.75 sqmm shielded control cables ,pvc insulated copper armoured, controll panel for auxilaries with starters for pumps,heaters etc
(n) RCC foundation with necessary earth work ,PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, filling and mass concrete / RCC M-30 (20 mm graded aggregate) as in foundations, Plinth beam along with necessary form work / TMT bars of 10mm dia and over cut to length bend to shape required including cranking, bending, spirally for hooping for columns, hooking ends and bidning with and including MS wire (annealed) not less than 0.9mm dia securing with clips / 10 mm thick plastering on fair faces of brick work or concrete surface in CM (1:6),even and smooth without using extra cement / Sand filling in layers around the foundation including watering and consolidation as per OEM dimensions
(o) Acoustic Enclosure shall comprise of the following (i) Specially designed to meet stringent MoEF/ CPCB norms/as per new Guidelines of Delhi NCR at 75% load under free field conditions (ii) The Acoustic Enclosure as per CPCB Norms is made of CRCA sheets in Munselgreen shade and a structural/ sheet metal base frame painted in black. or any other standard colour as specified by the OEM (iii) High quality noise absorbant and fire-retardant gradeacoustic insulation material (P.U. Foam) complying to IS8183 designed to have optimum serviceability (iv) Air inlet louvers specially designed to operate at rated load, Made on special purpose CNC machines for consistency inquality and workmanship (v) 11 tank pretreatment process and UV resistant powdercoating of all parts to withstand extreme environment, Use of special hardware for longer life, Flush styling - no projections, Fluid drains for lube oil and fuel,Fuel filling arrangement inside the enclosure
EXTERNAL WATER SUPPLY M&L for MS pipe header 250mm dia size 6.3mm thick 3 mtr length with flanged ends closed with end plates not less than 20 mm thick fixed with and including provision of 1 incoming and 4 outgoing connection of 100mm dia bore with flanged end including painting with two coat of red oxide primer.
Supplying , laying , jointing, welding and testing MS Pipe (Heavy class 'C') IS : 1239/3589, of sizes 100 mm laid in trenches or in Horizontal / Vertical / inclined position for connections suction, header and connected to out going water main CI/DI pipe line. Note:- MS Flanges incl fabrication work shall deemed to be included in the rates quoted by the contractor for this item
Supply, fixing, jointing & testing Cast Iron Sluice Valve of following sizes mm bore , ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top complete all as specified and as directed at site by the Engr-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
Making bore hole under the road, pavement, hard standing any type of soil through trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 250 mm dia suitable for 0.4 MPA working pressure
M&L for construction of valve pit chamber having internal dimension 120 cm x120 cm x120 cm (internal dimension) using PCC (1:4:8) using 40 mm graded stone aggregate for foundation 15 cm thick, 23 cm thick brick wall using old size bricks in CM (1:4), 10 mm thick rendering in CM (1:6) finished even and smooth without using extra cement all around the brick work, PCC (1:2:4) type B1 using 20 mm garded stone Agg as in coping for grouting MS frame including 3 mm thick MS top sheet cover with locking arrangement including 50 mm pad lock with double key arrangement, MS frame shall be made out of 40 x40 x5 mm thick angle iron including painting of steel surfaces with two coats of synthetic enemal paint over a coat of red oxideprimer including necessary form work and excavation in any type of soil ,returning filling in and removal of surplus soil to a distance not exc 50 mtr complete all as specified
Monoblock pump set with split casing electric driven having bronze impeller and stailless steel shaft mounted on common base frame having energy efficient motor running at 2900 RPM conferming to IS-12615, complete suitable for operation on 415 volts (+/-) 10%, 3 phase 50 Hz 10 LPS at 30 meter head (10HP) inclusive of pressure gauge, base frame and PCC foundation as per manufacturers recommendations.
Monoblock pump set split casing electric driven having bronze impeller and stailless steel shaft mounted on common base frame having energy efficient motor running at 2900 RPM conforming to IS-12615, complete suitable for operation on 415 volts (+/-) 10%, 3 phase 50 Hz 05 LPS at 30 meter head (5HP) inclusive of pressure gauge, base frame and PCC foundation as per manufacturers recommendations.
SEWAGE DISPOSAL M/L for providing , lowering,laying,alighning,fixing 200(OD) MM dia in position and jointing at all level/depth full round HDPE , DWC( double wall corrugated) pipes of SN 8 grade as per IS : 16098( Part 2) amended up to date in trenchs in complete incl all material, labour section , hydraulic testing ( including cost and conyance of water to site for testing ) and commissioning as per technical specification, drawing and as per circular ) all as specified and as directed
M/L for providing , lowering,laying,alighning,fixing 300(OD) MM dia in position and jointing at all level/depth full round HDPE , DWC( double wall corrugated) pipes of SN 8 grade as per IS : 16098( Part 2) amended up to date in trenchs in complete incl all material, labour section , hydraulic testing ( including cost and conyance of water to site for testing ) and commissioning as per technical specification, drawing and as per circular ) all as specified and as directed
Supplying, laying, jointing and testing of MS pipe (Heavy class 'C' ISI 1239/3589, of size 80mm laid in trenches or in horizontal/vertical/inclined position for connections suction header and connected to outgoing water main PPR pipeline complete all as specified and directed. Note :- MS flanges including fabrication work shall be deemed to be included in the rates quoted by the contractor for this item.
Description of Work / Item(s)
Amount
Manning and Operation of Sewage treatment plant having capacity 300 Cubic meter/day installed under item No. 1.00 of BOQ under Sch 'A' part I, for the duration of 24 hours in 03 (Three) shifts ie. For Ist Shift from 0600 Hrs to 1400 Hrs, IInd shift from 1400 Hrs to 2200 Hrs and IIIrd shift from 2200 Hrs to 0600 Hrs per day (with deploying one well experienced operator in each shift) for Ist year from next date of certified date of completion all as specified and directed. Note : (i) Water and Electric required for operation of plant shall be provided free of cost by the Department. (ii) All Consumable such as Sodium Hypochlorite and any other chemical required, compressure oil and grease etc required for operation of plant shall be provided by contractor at his own cost as per the manufacturer's instruction and direction of GE during the period of manning & Operation, cost of the same shall be deemed included in the unit rates quoted by contractor. (iii) Please ensure that all trade men engaged in subject work covered in EPF scheme. Proper doc should be maintained in this regard and submitted alongwith each payment.
(iv) The expense incurred due to insurance and EPF scheme for the staff deployed by the contractor for manning & operation shall also be deemed included in the quoted rates of BoQ. Nothing extra shall be admissible in this account. (v) Contractor’s quoted rate shall be deemed to include removal of dried sludge and its disposal outside MD land during the M&O period as directed by Engineer-in-Charge. (vi) Testing of of incoming sewage and treated sewage shall be done by the contractor from any Govt. approved lab as approved by GE on a monthly basis during the M&O period and test report shall be submitted to GE. Contractor’s quoted rate shall be deemed to include for the same. (vii) In case contractor fails to employ the duty personnel in any of the shift, he shall be liable to bear the recovery @ Rs 1500/- per shift and No payment shall be made for that shift.
All as per item No. 1 here-in-before but for 2nd year
All as per item No. 1 here-in-before but for 3rd year
All as per item No.1 here-in-before but for 4th year
All as per item No. 1 here-in-before but for 5th year
Manning and Operation of Sewage treatment plant having capacity 100 Cubic meter/day installed under item No. 1.00 of BOQ under Sch 'A' part I, for the duration of 24 hours in 03 (Three) shifts ie. For Ist Shift from 0600 Hrs to 1400 Hrs, IInd shift from 1400 Hrs to 2200 Hrs and IIIrd shift from 2200 Hrs to 0600 Hrs per day (with deploying one well experienced operator in each shift) for Ist year from next date of certified date of completion all as specified and directed. Note : (i) Water and Electric required for operation of plant shall be provided free of cost by the Department. (ii) All Consumable such as Sodium Hypochlorite and any other chemical required, compressure oil and grease etc required for operation of plant shall be provided by contractor at his own cost as per the manufacturer's instruction and direction of GE during the period of manning & Operation, cost of the same shall be deemed included in the unit rates quoted by contractor. (iii) Please ensure that all trade men engaged in subject work covered in EPF scheme. Proper doc should be maintained in this regard and submitted alongwith each payment.
(iv) The expense incurred due to insurance and EPF scheme for the staff deployed by the contractor for manning & operation shall also be deemed included in the quoted rates of BoQ. Nothing extra shall be admissible in this account. (v) Contractor’s quoted rate shall be deemed to include removal of dried sludge and its disposal outside MD land during the M&O period as directed by Engineer-in-Charge. (vi) Testing of of incoming sewage and treated sewage shall be done by the contractor from any Govt. approved lab as approved by GE on a monthly basis during the M&O period and test report shall be submitted to GE. Contractor’s quoted rate shall be deemed to include for the same. (vii) In case contractor fails to employ the duty personnel in any of the shift, he shall be liable to bear the recovery @ Rs 1500/- per shift and No payment shall be made for that shift.
All as per item No. 2 here-in-before but for 2nd year
All as per item No. 2 here-in-before but for 3rd year
All as per item No. 2 here-in-before but for 4th year
All as per item No. 2 here-in-before but for 5th year
M/s R. K. Bhambri
AMIT ASSOCIATES
M/s R. K. Bhambri
AMIT ASSOCIATES
M/s R. K. Bhambri
M/s JAIMAA ASSOCIATES
Bidder Name
M/s R. K. Bhambri
AMIT ASSOCIATES
M/s JAIMAA ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .