Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.9 LAccepted-Finance | ₹76.9 L | L1 | Accepted-Finance L1 BIDDER |
| 2 | L2₹76.9 LRejected-Finance FATULLAPUR P O P S NIMTA KOLKATA 700049 WEST BENGAL INDIA | 24 PARAGANAS NORTH | WEST BENGAL | 700049 | ₹76.9 L | L2 | Rejected-Finance HIGHER THAN L1 |
| 3 | L3₹76.9 LRejected-Finance | ₹76.9 L | L3 | Rejected-Finance HIGHER THAN L1 |
| 4 | Rejected-Technical 165 185 259 SINGATALA NORTH WARD NO 5 MALDA | MALDA | MALDA | WEST BENGAL | 732102 | - | - | Rejected-Technical UNSATISFACTORY |
| 5 | Rejected-Technical THAKURBARI LANE PO MOKDUMPUR DIST MALDA PIN 732103 | MALDA | MALDA | WEST BENGAL | 732103 | - | - | Rejected-Technical UNSATISFACTORY |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
11 Feb 2026, 11:00 amClosed
THE DRCS, Cooperation Directorate Malda Range
THE DRCS, Cooperation Directorate Malda Range
03/2025-26/COOP/MLD
2026_COD_992795_1
03/2025-26/COOP/MLD
Open Tender
CIVIL WORKS
365 days
MALD
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1.6 L
Yes
23 Feb 2026
21 Jan 2026
13 Feb 2026
21 Jan 2026
11 Feb 2026
21 Jan 2026
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoil within a lead of 75 m as directed. The item includes necess-ary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (P.W.D schedule page No. 02 & item No.2a)
Earth work in filling in foundation treanches or plinth with good earth in layers not exceeding 150 mm including watering and ramming etc. layer by layer complete. (P.W.D schedule page No.04 & item No.3a).
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidation the same by through saturation with water ramming complete including the cost of supply of sand . (P.W.D schedule page No. 02 & item No.4a)
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. (P.W.D schedule page No.34 & item No.1).
Cement concrete with graded stone ballast (40 mm size) excluding shuttering. (A) In ground floor. [P.W.D Schedule page no.60, item no.10(I)A(a)],
a) Brick work with 1st class bricks in cement morter (6:1). (P.W.D Schedule page no.70, item no.22a). In Foundation & Plinth
a) Brick work with 1st class bricks in cement morter (6:1). (P.W.D Schedule page no.70, item no.22a). b) In Superstructure
a) Brick work with 1st class bricks in cement morter (6:1). (P.W.D Schedule page no.70, item no.22a). In 1st Floor
a) Brick work with 1st class bricks in cement morter (6:1). (P.W.D Schedule page no.70, item no.22a). In 2 nd Floor
Ordinary Cement Concrete (mix 3 :1.5 :1) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor, as per IS codes. [P.W.D Schedule page no. 39, item no.7(a)].(i) Rajmahal Variety Stone. G.F.
Ordinary Cement Concrete (mix 3 :1.5 :1) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor, as per IS codes. [P.W.D Schedule page no. 39, item no.7(a)].(i) Rajmahal Variety Stone. F.F.
Ordinary Cement Concrete (mix 3 :1.5 :1) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor, as per IS codes. [P.W.D Schedule page no. 39, item no.7(a)].(i) Rajmahal Variety Stone. S.F.
Reinforcement for reinforced concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial strightening and removal of , complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor /upto 4 m. (i) Tor steel.( Sail/ Tata/ RINL) [P.W.D Schedule page no.66, item no.15]In ground floor ----
Reinforcement for reinforced concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial strightening and removal of , complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor /upto 4 m. (i) Tor steel.( Sail/ Tata/ RINL) [P.W.D Schedule page no.66, item no.15]In first floor ----
Reinforcement for reinforced concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial strightening and removal of , complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor /upto 4 m. (i) Tor steel.( Sail/ Tata/ RINL) [P.W.D Schedule page no.66, item no.15]In second floor ----
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood plank of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. [P.W.D Schedule page no.64, item no.12]. (a) 25 mm to 30 mm thick wooden shuttering without staging. ground floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood plank of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. [P.W.D Schedule page no.64, item no.12]. (b) 25 mm to 30 mm thick wooden shuttering with staging. Ground Floor.
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood plank of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. [P.W.D Schedule page no.64, item no.12]. (b) 25 mm to 30 mm thick wooden shuttering with staging. First Floor.
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood plank of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. [P.W.D Schedule page no.64, item no.12]. (b) 25 mm to 30 mm thick wooden shuttering with staging. Second Floor.
125 mm thick bricks work with 1st class brick in cement mortar (4:1) G.F.
125 mm thick bricks work with 1st class brick in cement mortar (4:1) F.F.
125 mm thick bricks work with 1st class brick in cement mortar (4:1) S.F.
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corner as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary [P.W.D Schedule page No.320, item No 2]. i) With 6:1 cement Plaster. a) 15 mm thick plaster. G.F.
With 6:1 cement Plaster. b) 20 mm thick plaster.. G.F.
With 6:1 cement Plaster. c) 10 mm thick plaster.. G.F.
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corner as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary [P.W.D Schedule page No.320, item No 2]. i) With 6:1 cement Plaster. a) 15 mm thick plaster. F.F.
With 6:1 cement Plaster. b) 20 mm thick plaster.. F.F.
With 4:1 cement Plaster. b) 10 mm thick plaster.. F.F.
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corner as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary [P.W.D Schedule page No.320, item No 2]. i) With 6:1 cement Plaster. a) 15 mm thick plaster. S.F.
With 6:1 cement Plaster. b) 20 mm thick plaster.. S.F.
With 4:1 cement Plaster. b) 10 mm thick plaster.. S.F.
Neat cement punning about 1.5 mm thick in wall, dado, window sills floors, drains etc. [P.W.D Schedule page no.324, item no 8]. G.F.
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) ii) Luxury Quality
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (iv) Two coats (with any shade except white)
Wood work in door and window frame fitted and fixed in position complete including a pretective coat of painting at the contact surface of the frame excluding cost of concrete, iron butt hinges and MS Clamps. In Ground Floor. [P.W.D Schedule page no.114, item no 1]. (h) Neem, Jam, jackfruits
Panel shutters of door and window, as per design (each panel consisting of single plank without joint),. In Ground Floor [P.W.D Schedule page no.117, item no.1].(c) 35mm thick shutter with 19 mm thick panel of size 30 to 45 cm. Other Local Hard Wood (Sishu, Gama, Chap, Badam...) Plank.
Supplying, fitting & fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc by cement concrete (4:2:1) as per direction. [P.W.D Schedule page no.190, item no 18]. 40mm x 6mm 250mm length.
Iron But hinges of approved quality fitted and fixed with steel screws, ISI mark. [P.W.D Schedule page no.192, item no 20]. (vii) 100mm x 75mm x 3.50mm
Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16 mm dia rod with centre bolt and round fitting. [P.W.D Schedule page no. 143, item no 27i].
Anodised aluminium barral/tower/socket bolt (full covered) of approved manufactured from extruded section conforming to I.S.I. specification (I.S.204/74) fitted & fixed with cadmium plated screws.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S specification (IS 230/72) fitted and fixed complete. [P.W.D Schedule page no.216, item no 65].
M.S or W.I ornamental grill or approved design joints continuously welded with M.S, W.I flats and bars for windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. [P.W.D Schedule page no.156, item no 10]. (ii) Grill weighting above 10 Kg./Sq.m. and upto 16Kg/ Sq.m.
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.
Providing and fixing of factory made uPVC Sliding window (White Colour) complete, (U value=1.9-1.3 W/m²K, flame resistant, self extinguishing, lead 2 free) comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (±0.2 mm) duly reinforced with G.I. section 1.6.....b) 3 Track 3 Sash window frame of size 122 x 54 mm & Sash of size 64 x 47 mm both having wall thickness of 2.3 ± 0.2 mm
Supplying,fitting approved type ventilator in position after cutting holesin walls setting in cement morter…… R.C.C.ventilator of 20 mm thick I)upto 0.10 sqm area
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surface by sand papering etc. [P.W.D Schedule page no.200, item no 1. A) On timber surface
Painting 2 coat with best quality synthetic enamel paint of approved make and brand including smoothenig surface by sand papering etc. including using of approved putty etc. on the surface if necessary. A) On Steel or other Metal surface
Painting 2 coat with best quality synthetic enamel paint of approved make and brand including smoothenig surface by sand papering etc. including using of approved putty etc. on the surface if necessary. [P.W.D Schedule page no.200, item no 2]. A) On Wooden surface
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. xiv) 12mm thick coloured / tinted / toughened glass coforming to IS: 2553-1992 (Part-II)
Artificial stone in floor,dado,staircase etc. with cement concrete (1:2:4) with stone-chips laid in panels as directed with topping made with ordinary or white cement and marble dust in proportion (1:2) including smooth finishing……….using grey cement. 35 mm thick. [P.W.D Schedule page no.40, item no 3(ii)] a) Ground Floor
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc.... ln Ground FIoor:(size not Iess than 600mmX600 mm X 10.2 mm thick). Ground Floor
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006…. ln First FIoor:(size not Iess than 600mmX600 mm X 10.2 mm thick). First Floor
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006…. ln second FIoor:(size not Iess than 600mmX600 mm X 10.2 mm thick). Second Floor
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. Wall
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary
Supplying, fitting & fixing UPVC pipes-A-types and fitting conforming to IS:13592-1992 with all necessary clams nails, including making holes in walls, floor, etc. cutting treches in any soil through masonary concerete structure etc….. P.W.D. schedule page no 212, item no.21 A) UPVC PIPE 110 mm
Supplying, fitting & fixing UPVC pipes-A-types and fitting conforming to IS:13592-1992 with e etc….. P.W.D. schedule page no 212, item no.21 A) UPVC Fittings T 110 mm
Supplying, fitting & fixing UPVC pipes-A-types and fitting conforming to IS:13592-1992 with e etc….. P.W.D. schedule page no 212, item no.21 A) Bend 87.5 Degree 110 mm
Supplying, fitting & fixing UPVC pipes-A-types and fitting conforming to IS:13592-1992 with e etc….. P.W.D. schedule page no 212, item no.21 A)shoe 110 mm
Add Cost for water supply sanitary works 15%
Add Cost for Electrification 15%
Please Enable Macros to View BoQ information
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 15.13 MB
BOQ_2427818.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid