Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹43.9 L+₹9.0 L (25.7%)Rejected-Finance 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹44.4 L+₹9.5 L (27.1%)Rejected-Finance AT SRIKONA PS CHANDIPUR DIST BALASORE ODISHA 756 025 | CHANDIPUR | BALASORE | ODISHA | 756025 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹46.7 L+₹11.7 L (33.6%)Rejected-Finance SRIKONA POTAPOLA CHHAKA CHANDIPUR ROAD BALASORE ODISHA 756025 | BALASORE | BALESHWAR | ODISHA | 756025 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹47.8 L+₹12.9 L (36.8%)Rejected-Finance KACHERY ROAD BALASORE 756001 ODISHA | BALESHWAR | ODISHA | 756001 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
20 Jun 2023, 6:00 pmClosed
GARRISON ENGINEER
GE I R and D Chandipur Post Chandipur PIN 756025
REPAIR TO ROOF TREATMENT JOINERY WOODEN AND ALUMINIUM FALSE CEILING AC AND GALVALUME SHEET SUNKEN FLOORS AND CERTAIN ALLIED WORKS AT OFFRS MD ACCN OTM ACCN AND TECH AREA UNDER AGE B AND R I CHANDIPUR
2023_MES_599991_1
8831/E8
Open Tender
Civil Works
Item Rate
180 days
Chandipur
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandipur
₹70,000
Yes
30 Jun 2023
31 May 2023
22 Jun 2023
31 May 2023
20 Jun 2023
14 Jun 2023
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.
Dismantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed.
S & F 0.50 mm thick Pre- painted galvalume aluminium zinc coating GI based corrugated steel colour sheet having tensile strength of 550 Mpa as in roof covering with self tapping screws complete all as specified and directed.
S & F 0.50 mm thick Pre- painted galvalume aluminium zinc coating GI based plain colour sheet having tensile strength of 550 Mpa as in roof covering with self tapping screws complete all as specified and directed.
S & F 6 mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc complete all as specified and directed.
M & L for asbestos cement two piece adjustable plain wing ridge 6 mm thick fixed with L or J type or cranked hook bolts complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
S & F power coated anodised aluminium snap grid frame work for false ceiling of grid size 605 mm x 605 mm fixed to walls with rawl plugs and screws and hung to roof members with 6 mm dia GI wire (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia. 40 mm long with and including 4 mm thick non asbestos fibre cement building designer board fixed or laid / inserted to timber / GI / aluminium frame work and applying two coats of distemper oil emulsion complete all as specified and directed .
Taking down Chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down Chowkats or frames exc. 1.50 Sqm but n.exc 4.00 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down shutter of any description n. exc 1 sqm each. complete all as specified and directed.
Taking down shutter of any description but exc 1 sq. m and n exc 2 sq. m each complete all as specified and directed.
Taking down shutter of any description but exc 2 sq. m each complete all as specified and directed.
M & L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
M & L for Factory made of 35 mm thick glazed and skeleton shutters made of 2nd class hard wood, open rebated and prepared to receive glass gauge edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed .
M & L for Factory made of 30 mm thick glazed and skeleton shutters made of 2nd class hard wood, open rebated and prepared to receive glass gauge edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc for window, ventilator shutters, etc. as specified in SSR Part I, Section 8 clause 8.24(b) and fitted to chowkhat complete all as specified and directed .
M & L for Factory made of 30 mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
M & L for preparation of new or previously untreated surface of wood of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamelled paint over one coat of pink primer complete all as specified and directed
Taking down and refixing shutter after repair of any description n. exc 1 Sqm each in same opening complete all as specified and as directed.
Taking down and refixing shutter after repair of any description exc 1 Sqm but n. exc 2 Sqm each in same opening complete all as specified and as directed.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinforced with MS Square tube complete all as specified and directed .
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as directed .
S & F for butt hinges medium weight cold rolled mild steel of 100 mm size. complete all as specified and directed . (for wooden doors)
S & F for butt hinges medium weight cold rolled mild steel of 75 mm size. complete all as specified and directed . (for wooden windows)
S & F for Stainless steel butt hinges of 75 mm size. complete all as specified and directed . (for PVC door)
S & F for 150 mm extruded Aluminium aloy handles, febricated type anodised complete all as specified and directed .
S & F for 100 mm extruded Aluminium aloy handles, febricated type anodised complete all as specified and directed .
S & F for 150 mm size aluminium anodised barrel tower bolt of extruded section complete all as specified and directed .
S & F for 100 mm size aluminium anodised barrel tower bolt of extruded section complete all as specified and directed .
S & F for 150 mm long aluminium plate type II hook & eye for window shutter complete all as specified and as directed.
S & F for 250 mm Sliding door bolt aluminium alloy, anodised, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S & F for Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
S & F for 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
S & F for 3 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
M & L for flat iron for hold fast of doors / windows confirming to FE - 290 Gde E-165 complete all as specified and directed. (Flat Iron 250 x 30 x 3 mm thick @ 0.707 Kg / RM)
Cutting holes for inserting hold fasts in Brick walls built in cement mortar and making good disturbed portion in PCC (1: 2 :4) type B1 or in cement mortar (1:3) as required, depth of embedded portion exceeding half brick but not exceeding one brick for full brick walls, complete all as specified and as directed .
S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length 150 mm fixed in floor complete all as specified and as directed .
S & F in repairs Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length 150 mm fixed in floor complete all as specified and as directed .
S & F in repairs MS Mortice lock, vertical type, size 100 mm, long 4 levers with handles complete all as specified and directed.
S & F in repairs door closer hydraulically regulated of cast iron body, designation No.3 universal type suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed.
Demolition of cement concrete of any description in any position not otherwise specifically provided for (including old roof treatment) complete all as specified and directed.
Roughening surfaces of old concrete floors/slabs by pickling, sweeping cleaning and washing down with water to remove dust, brushing neat cement slurry with 3.0Kg of cement per sqm including removal of old roof treatment complete all as specified and directed.
M & L for providing average 25 mm thick PCC 1 : 2 : 4 type B-0 (using 12.5 mm graded stone aggregate) as in padding concrete for getting proper slope of roof / covering etc as complete all as specified and directed.
M & L for rendering 10 mm thick average in cement mortar (1:4) over roof surfaces mixed with WPC as per manufacturer’s instructions, finished fair without using extra cement complete all as specified and directed. (NOTE: WPC shall be measured and paid separately)
Preparation of surface and applying two coats of hot bitumen blown VG-30 to concrete surfaces at the rate of 1.5 kg. per sq. m per coat complete all as specified & directed.
M & L for roof treatment using APP based polymeric membrane, minimum weighing 3 kg / sqm and minimum 3 mm thick, reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application with side over lap 75 mm and end lap minimum 100 mm and sealing over lap and joints as per manufacturer's instructions complete all as specified and directed.
M & L for one coat of aluminium paint 0.30 ltr / sqm above the APP membrane complete all as specified and directed.
Taking down cement plaster any description and the like on brick or stone walls, etc including raking out joints,hacking for key, scrubbing down with water etc. complete all as specified and directed.
M & L for 10 mm thick rendering in CM 1:6 on brick or concrete surfaces finished even and smooth on wall complete all as specified and directed.
M & L for 15 mm thick rendering in CM 1:4 on brick or concrete surfaces finished even and smooth with integral water proofing compound (IWPC Measured and paid seperately) on wall complete all as specified and directed.
M & L for preparation of newly plastered / unplastered surfaces of walls and two coats distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed.
Preparation of new plaster surface of wall and applying two coats of Premium Acrylic Smooth exterior paint with Silicone additives of required shade@ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and directed.
Supply only integral liquid water proofing compound
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to tore (measured overall as fixed along the centre line over fittings and accessories)
S & F for 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F for 110 mm PVC (SWR) bends any radius complete all as specified and directed.
S & F for 110 mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
Dismantling water tanks of any type of capacity exc 250 but n.exc 500 liters and removing to store complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks of 500 ltrs capacity (cylin-drical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part I .
Dismantling water tanks of any type of capacity exc 500 liters but n. exc 1000 ltrs and removing to store complete all as specified and directed.
S & F Rotational moulded polyethylene water storage tanks of 1000 ltrs capacity (cylin-drical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part I .
Disconnecting existing 500 Ltr tanks, setting aside (or lowering if required) from mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.
Disconnecting existing 1000 Ltr tanks, setting aside (or lowering if required) from mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.
S & F of Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed to 20 mm bore pipe complete all as specified and directed.
Taking up or down steel tubing 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Taking up or down steel tubing 20mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
S & F GI pipe medium grade 15 mm dia bore galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F GI pipe medium grade 20 mm dia bore galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Fixing only, ‘Medium grade’ galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors of 15 mm bore complete all as specified and directed.
Fixing only, ‘Medium grade’ galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors of 20 mm bore complete all as specified and directed.
Taking down aluminium anodised shutters for doors, windows, ventilator partition wall and refixing after necessary repairs etc complete all as directed by Engineer-in-charge. Note : Aluminium section, glass, prelaminated particle board panels and floor hinges etc will be measured and paid separately.
Dismantling timber scantlings framed work under 40 sq. cm in section, in any position complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
S & F for Anodised aluminium frame for doors, windows, ventilators, partition with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S & F for Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and directed.
S & F for Anodised aluminium window and ventilator shutters, fixed type without sash bar/sliding shutter, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, hinges etc. complete all as specified and directed.
S & F 12 mm Prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations fixed with screws to timber frame work complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with screws complete all as specified and directed.
S & F 12 mm Prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations fixed with screw to timber frame work including second class hardwood beading all around complete all as specified and directed.
S & F sheet glass 5.5 mm thick, ordinary quality in square n exc 0.5 sq. m in each pane fixed to aluminium door/window/partition complete all as specified and directed.
S & F sheet glass 5.5 mm thick, ordinary quality in square exc 0.5 sq.m in each pane fixed to aluminium door/window/ventilator/partition complete all as specified and directed.
S & F sheet glass 5.5 mm thick, ordinary quality in square exc 0.5 sq.m in each pane fixed to aluminium door/window/ventilator/partition including hacking out old broken glass complete all as specified and directed.
S & F Anodised Aluminium grill (anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC-15 of approved design / pattern, with approved standard section and fixed to the existing window frame with CP Brass / Stainless Steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge.
Taking down care fully collapsible gate complete all as specified and directed.
S & F for Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and as directed.
Taking down care fully steel rolling shutters of any size complete gear operated / mannual operated complete all as specified and directed.
S & F for Steel rolling shutters, with out ball bearing thickness of lath 1.25 mm as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
Refixing of steel rolling shutters including necessary repairs / replacement of spare parts if required and cleaning dust, greasing etc including making good the disturb surface of brick / RCC wall in existing complete all as specified and directed.
M & L for preparation of new steel surfaces over 10 cm in width or girth and applying two coats of aluminium paint over a coat of aluminium red oxide primer complete all as specified and directed.
M & L for preparation of old steel surfaces over 10 cm in width or girth and applying one coat of aluminium paint complete all as specified and directed.
Supply only 75 mm wide, 1.25 mm thick MS profile for rolling shutter, riveted / welded were necessary including taking out old unserviceable profile one coat of red oxide primer and painting one coat complete all as specified and directed.
S & F in repairs ball bearing for rolling shutter complete all as specified and directed.
S & F in repairs Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
Supply only MS spring 40 CM long for rolling shutter for counter balancing the weight of rolling shutter complete all as specified and directed.
S & F in repairs gear box with handle complete all as specified and directed.
S & F in repairs 0.80 mm Mild steel, plain, black sheet in rolling shutter cover hood, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc.
S & F for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete with Fe-410- W(Gde- E-250) quality- B complete all as specified and as directed.
S & F for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete with Fe-410- W(Gde- E-250) quality- B complete all as specified and as directed.
S & F for 1.25 mm Mild steel, plain, black sheet in steel gates, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
Treatment of sunken floor slab comprises the following specificatons and all as specified :- (i) Demolition of existing treatment including tiling, concrete etc. (ii) M & L for cleaning the sunken/ lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush,chisel out any mortar sticking to the surface and brooming completely. 40 mm thick avg PCC 1:2:4 type B0 using 12.5 mm graded aggregate as in padding concrete to achieve proper slope including 50 mm PVC pipe and cutting holes in bricks or RCC wall for spour. (iii) Rendering of uneven surface with 6mm thick CM 1:4 mixed with liquid water proofing compound @0.4 % by wt of cement consumed. Fill it with water and check dampness and seepage, where dampness /seepage is noticed, nozzles shall be fixed and grouting carried out. (iv) All junction points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. (v) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (vi) M & L for applying two coats of polymer modified cementious water proof coating as per manufacturer's instruction to bottom and vertical sides up to finished floor level +100 mm ht. The thickness of two layer shall be 1 mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface portion all as specified and directed. (vii) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with liquid water proofing compound @ 0.4% by wt of cement consumed as per manufacturer's speciication incl rounding of corners and junctions sloping towards spout. Note: Test the water proofed area (ponding test) by filling water for at least 72 hrs and tested for leakage, seepage and to the entire satisfaction of GE. The treatment shall be carried out by authorised applicators of chemicals.(Cost of testing is included in the rates quoted). (viii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anti-corrosive paint( Black Japan). (ix) Two Nos of 50mm bore GI medium grade 600mm long spout shall be provided through external wall to drain out accumulated water.
M & L for joint free Non - skid Ceramic tiles 7-8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles in 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Treatment for damaged ceiling of roof or chajjas comprising the following specification and as directed :- (a) Dismantling and stripping the damaged concrete of Internal Roof plaster by light chiseling and other manual methods until damage surfaces clean up. That might affect adhesion are to be removed by wire brushing. The entire exposed surface shall be washed thoroughly with Clean water and then allowed to dry. (b) Exposing the corroded reinforcement completely along its full circumference, cleaned to remove all loose scale and corrosion deposit applying rust removing chemical followed by removing the rust by sand paper and cleaning the area thoroughly by water and allow it to dry. ( Dr. FIXIT / Fosroc / SIKA / REDWOP Chemicals ) (c) Supply and Application of Epoxy Zinc Rich primer on the Prepared Reinforced surface after electro welding of it’s sectional area by brush , the primer should have a minimum specific gravity 1.75. Minimum Wet film thickness /coat 100 microns & Dry film thickness / coat 40 microns. Minimum Adhesive bond strength with steel is 1.5 N/mm2. ( Dr. FIXIT / Fosroc / SIKA / REDWOP Chemicals ) (d) A general purpose Epoxy Bonding agent to be applied on the concrete surface before the application of free flow non-shrink cementitious micro concrete mortar. The bonding agent should have minimum compressive strength 40 N/mm2 as per BS6319 Part 7. Minimum Flexural Strength 25 N/mm2 as per BS 6319 Part 3 and minimum bond strength as per ASTM C88111 N/mm2 . ( Dr. Fixit / Fosroc / SIKA / REDWOP). (e) Supply and Apply non shrink highly consistent light weight high grade polymer modified repair mortar for vertical and over head cementitious patch work mortar system where local spelling has taken place or shuttering is not possible. The mortar can be applied from a minimum 5mm to 50mm thickness in vertical and overhead applications. The mortar should have a minimum compressive strength 35 N/mm2 in 7 days and 45 N/mm2 in 45 days. Minimum flexural strength should be 6.5 N/mm2 in 28days. (f) Supply and Apply, covering plaster up to 10 mm thick with mixing ratio 1- 4 Cement / Sand, adding adhesives (Butadiene Styrene Emulsion), for smooth finishing on after Application of non shrink highly consistent light weight high grade polymer modified repair mortar . ( Dr. FIXIT / Fosroc / SIKA / REDWOP Chemicals )
Treatment for parapet wall comprising the following specification and as directed :- (a) Dismantling and stripping the damaged concrete of entire Parapet wall , Fascia etc by light chiseling & other manual methods until sound concrete surfaces comes up. Any trace of loose plaster, oil, grease, and funguses if any or other materials that might affect adhesion are to be removed by wire brushing. The entire exposed surface shall then be washed thoroughly with Clean water and then allowed to dry. (b) Exposing the corroded reinforcement completely along its full circumference, cleaned to remove all loose scale and corrosion deposit applying rust removing chemical followed by removing the rust by sand paper and cleaning the area thoroughly by water and allow it to dry.( Dr. Fixit / Fosroc / SIKA / REDWOP ) (c) Supply and Application of Epoxy Zinc Rich primer on the Prepared Reinforced surface after electro welding of it’s sectional area by brush , the primer should have a minimum specific gravity 1.75. Minimum Wet film thickness /coat 100 microns & Dry film thickness / coat 40 microns. Minimum Adhesive bond strength with steel is 1.5 N/mm2. ( Dr. Fixit / Fosroc / SIKA / REDWOP ) (d) M & L formwork of smooth finish surfaces of Fascia, Parapet Wall incl. fixing and striking out after pouring of concrete at all levels with necessary Bamboo staging. (e) A modified Styrene Butadiene Emulsion for use as a bonding aid and gauging liquid for cementitious system to be mixed with cement slurry before the application of two component micro concrete to be used @ 5 Ltr./bag of cement. The bonding agent should have minimum compressive strength 24 N/mm2 . ( Dr. Fixit / Fosroc / SIKA / REDWOP). (f) Supply and Application Two component high build polymer modified cementitious reinstatement mortar where local spelling has taken place or shuttering is not possible. The Mortar can be applied in thicknesses from 15mm to 40mm thickness in vertical and 25mm in overhead situations. The Mortar should have a minimum Compressive strength 7 N/mm2 in 1 Day and 20 N/mm2 in 28days. Minimum Flexural strength should be 4.5 N/mm2 in 28 days. Minimum Tensile strength should be 1.7 N/mm2 in 28days. ( Dr. Fixit / Fosroc / SIKA / REDWOP). (g) Supply and Apply, covering plaster 10 mm thick with mixing ratio 1- 4 Cement / Sand, adding adhesives butadiene styrene emulsion, for smooth finishing on Fascia / Parapet Wall after Application of two component high build polymer modified cementitious reinstatement mortar. ( Dr. FIXIT / Fosroc / SIKA / REDWOP ) (h) M&L APPLYING curing compound over cement plaster as curing, complete as per manufacturer’s instruction and as directed by EIC. ( Dr. Fixit / Fosroc / SIKA / REDWOP).
ELECTRO COMMERCIAL CO
M/s Manas Ranjan Bera
bholanath bera
R.B.Construction
chauhan syndicate
DS ENTERPRISES
J B NATH AND SON
Bidder Name
RANA ENTERPRISES
DS ENTERPRISES
J B NATH AND SON
chauhan syndicate
R.B.Construction
ELECTRO COMMERCIAL CO
bholanath bera
M/s Manas Ranjan Bera
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .