| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹25.8 L+₹4.9 L (23.7%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than L1 | |
| 3 | L3₹27.6 L+₹6.8 L (32.6%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than L1 | |
| 4 | L4₹28.8 L+₹7.9 L (38.2%)Rejected-Finance PHAYANG GOMPA COMPLEX AGLING ROAD SKALZANGLING LEH LADAKH J K 194101 | LEH | LEH | LADAKH | 194101 | L4 | Rejected-Finance Rejected being other than L1 | |
| 5 | L5₹29.5 L+₹8.6 L (41.5%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L5 | Rejected-Finance Rejected being other than L1 |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
1 May 2021, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR MAINTENANCE OF LT CABLE MCCBS LT PANELS WITH CONNECTED ACCESSORIES AT SECTOR A AND B AND ADJACENT AREA UNDER GE 865 EWS
2021_MES_434772_1
865/EWS(NIT-01)/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹92,000
Yes
12 Jun 2021
6 Apr 2021
3 May 2021
6 Apr 2021
1 May 2021
22 Apr 2021
Amount
Supply and installation,over head, aluminium conductor, steel reinforced, weasel, including making connections and fixing on poles with all necessary arrangements, including dismantling of old ACSR or AAC conductors complete all as specified and as directed by Engr-in-Charge. Note: Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring taut horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers, etc.
S&F for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint, including dismantling old u/s cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m complete all as specified and as directed by Engr-in-Charge.
M&L for Stay assembly complete with accessories as shown in electrical plate No. 1 (Excavation and concrete measured separately) including dismantling old u/s stay assembly complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth, for foundation etc. or for shafts, welles cesspitsm, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5m in depthe in hard/dense soil and getting out , complete all as specified and as directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25m, complete all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the strating point, complete all as specified and directed by Engr-in-Charge.
Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, punned to 18 cm thick complete all as specified in clause 19.75 of SSR Par-I, complete all as specified and directed by Engr-in-Charge. Note : only punned thickness of 18 cm shall be measured and paid.
S&F in replacement of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-I flate size 250 x 150x40mm , complete all as specified and directed by Engr-in- Charge.
S&F in replacement cable route indicator made out cast iron and embedded LT Cable on the plate of size 80 mm dia 5 mm thick and gouting lugg of suitable size including gouted in PCC foundation of suitable size complete all as directed and directed by Engr-in-Charge.
Supply and fix Indicator lamp LED type (Red,Yellow, green) moulded single piece suitable for LT Panels including taking out the Old U/S indicator lamp and directed by Engr-in-Charge.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 2 core, 16 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches including taking down of old cable complete all as specified and directed by Engr-in-Charge. Make : Cable Corporation of India/Finolex Cable Co/Polycab/ Gloster/Havells/KEI/ RR Kabel Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 4 core, 16 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches including taking down of old cable complete all as specified and directed by Engr in Charge. Make : Cable Corporation of India/Finolex Cable Co/Polycab/ Gloster/Havells/KEI/ RR Kabel Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 core, 25 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches including taking down of old cable complete all as specified. Make : Cable Corporation of India/Finolex Cable Co/Polycab/ Gloster/Havells/KEI/ RR Kabel Note : Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately and directed by Engr-in-Charge.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 core, 35 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches including taking down of old cable complete all as specified. Make : Cable Corporation of India/Finolex Cable Co/Polycab/Gloster/ Havells/KEI/ RR Kabel Note : Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately and directed by Engr-in-Charge.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 core, 50 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches including taking down of old cable complete all as specified. Make : Cable Corporation of India/Finolex Cable Co/Polycab/ Gloster/ Havells/KEI/ RR Kabel Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately and directed by Engr-in-Charge.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 core, 70 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches including taking down of old cable complete all as specified and directed by Engr-in-Charge. Make : Cable Corporation of India/Finolex Cable Co/Polycab/ Gloster/Havells/KEI/ RR Kabel Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 core, 120 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches including taking down of old cable complete all as specified and directed by Engr-in-Charge. Make : Cable Corporation of India/Finolex Cable Co/Polycab/ GlosterHavells/KEI/ RR Kabel Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 core, 240 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches including taking down of old cable complete all as specified and directed by Engr-in-Charge. Make : Cable Corporation of India/Finolex Cable Co/Polycab/Gloster /Havells/KEI/ RR Kabel Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
S&F in replacement danger notice Plate of 1.6 mm thick mild steel sheet , vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS Clamps , bolts and nuts of approved size, for LT ,20x15 CM size and directed by Engr-in-Charge.
S&F in replacement MCCB 630 Amps current carrying capacity 50 KA, 3 pole AC, 415 Volts three pole with thermal & adjustable magnetic setting complete all as specified and directed by Engr-in-Charge. Make: Legrand (Ekinoxe)/Schneider (Acti-9)/Siemens (Betagard-8GB32)/ABB/L&T
S&F in replacement MCCB 630 Amps current carrying capacity 50 KA, 4 pole AC, 415 Volts three pole with thermal & adjustable magnetic setting complete all as specified and directed by Engr-in- Charge. Make: Legrand (Ekinoxe)/Schneider (Acti-9)/Siemens (Betagard-8GB32)/ABB/L&T
S&F in replacement MCCB 500 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with thermal & adjustable magnetic setting complete all as specified and directed by Engr-in-Charge. Make: Legrand (Ekinoxe)/Schneider (Acti-9)/Siemens (Betagard-8GB32)/ABB/L&T
S&F in replacement MCCB 400 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with thermal & adjustable magnetic setting complete all as specified and directed by Engr-in-Charge. Make: Legrand (Ekinoxe)/Schneider (Acti-9)/Siemens (Betagard-8GB32)/ABB/L&T
Supply and fix in replacement MCCB 350 Amp 4 Pole of rupturing capacity 36 KA complete all as specified and directed by Engr-in-Charge. Make: Legrand (Ekinoxe)/Schneider (Acti-9)/Siemens (Betagard-8GB32)/ABB/L&T
M&L for prepration including complete removal of existing treatment of old Steel Surfaces and applying two coat of synthetic enamel white paint over a coat of red oxide primer of LT Panels including cleaning of exposed surface with brush and empry paper including painting with smoke grey paint all as directed any size of LT Panels complete all as specified and directed by Engr-in-Charge. MAKE: NEROLAC PAINTS/ JEHNSON & NICHOLSON/BERGER PAINTS/ICI DULUXE/ASIAN PAINTS
M&L for prepration including complete removal of existing treatment of old Steel Surfaces and applying two coat of synthetic enamel white paint over a coat of red oxide primer/priming paint plaster coat to LT Steel tubular /PCC Pole and upto 1 Mtr height from ground level alternative in Yellow and black or white and black strips of 30 CM height each including numbering of Pole No with black paint complete all as specified and directed by Engr-in-Charge. MAKE: NEROLAC PAINTS/ JEHNSON & NICHOLSON/BERGER PAINTS/ICI DULUXE/ASIAN PAINTS
S&F in replacement mild steel galvanized pipe light grade 80 mm nominal bore for passing of cable fixed to poles/walls/laid under floor/roads complete with and including, fittings as requited all as specified and directed by Engr-in-Charge. MAKE : TATA/JINDAL/BST/Prakash Surya
S&F in replacement mild steel galvanized pipe light grade 50 mm nominal bore for passing of cable fixed to poles/walls/laid under floor/roads complete with and including, fittings as requited all as specified and directed by Engr-in-Charge. MAKE : TATA/JINDAL/BST/Prakash Surya
S&F in replacement mild steel galvanized pipe light grade 40 mm nominal bore for passing of cable fixed to poles/walls/laid under floor/roads complete with and including, fittings as requited all as specified and directed by Engr-in-Charge. MAKE : TATA/JINDAL/BST/Prakash Surya
S&F pin type, porcelain,vitreous, white, green & brown insulator including one galvanised iron steel spindle, two galvanized iron washer and one galvanised iron nut, working pressure 1100 Volts and of size 65 mm dia and 100 mm height ISI marked including dismantling insulators any type and any size complete all as specified and directed by Engr-in-Charge. Make : BHEL/Mysore/Pactil/Jayshree/WS Insulators/Southern Insulators/Jaipura Brothers/Hitkari/Bengal Poteries
Supply & fix shackle type, porcelain,vitreous, white, green & brown insulator including one galvanised iron steel spindle, two galvanized iron washer and one galvanised iron nut, working pressure 1100 Volts and of size 115 mm dia and 100 mm height ISI marked including dismantling insulators any type and any size complete all as specified and directed by Engr-in-Charge. Make : BHEL/Mysore/Pactil/Jayshree/WS Insulators/Southern Insulators/Jaipura Brothers/Hitkari/Bengal Poteries
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of 32 x 6 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR (Part-I) including taking down old u/s earthing set complete all as specified and directed.
S&F in replacement GI earthing strip of size 25x4 mm on PVC/Porcelain insulators at suitable distance with saddeles and fixing screws for roof/wall conductors and down conductors above ground all joints of GI strip should be brazed properly and directed by Engr-in-Charge.
M&L in replacement for Synthetic Insulating Mat for Electrical Instrument of size 2mx1mx10mm complete all as specified and directed by Engr-in-Charge.
S&F PVC Spacers 2/4 way for LT OH Line 1100 Volts grade with necessary screws nuts bolts etc complete all as specified and directed prevent the lines touching each other on heavy wind as a preventive arrangement to the existing system including removing the existing old/out lived spacers and directed by Engr-in-Charge.
S&F ON Load Change over ( Front Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 1000 Amps with connecting acessories incluidng taking down old u/s change over switch complete all as specified and directed by Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F ON Load Change over ( Front Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 630 Amps with connecting acessories incluidng taking down old u/s change over switch complete all as specified and directed by Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F ON Load Change Change over (Front Handel) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 400 Amps with connecting acessories incluidng taking down old u/s change over switch complete all as specified and directed by Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F ON Load Change over ( Front Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 125 Amps with connecting acessories incluidng taking down old u/s change over switch complete all as specified and directed by Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F ON Load Change over( Front Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 63 Amps with connecting acessories incluidng taking down old u/s change over switch complete all as specified and directed by Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F in repalcement Alluminium Thimbale of size 35/50/70/95 Sq mm complete all as spd and directed by Engr-in-Charge. .
S&F in repalcement Alluminium Thimbale of size 120/150/185/240/400 Sq mm complete all as spd and directed by Engr-in-Charge.
S&F in replacement of ON Load Change Change over ( Side Handel) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 63 Amps with connecting acessories complete all as specified and directedby Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F in replacement of ON Load Change Change over ( Side Handel) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 125 Amps with connecting acessories complete all as specified and directedby Engr in Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F in replacement of OFF Load Change Change over ( Side Handel) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 125 Amps with connecting acessories complete all as specified and directedby Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F in replacement of OFF Load Change Change over ( Side Handel) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 200 Amps with connecting acessories complete all as specified and directedby Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F in replacement of OFF Load Change Change over ( Side Handel) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 320 Amps with connecting acessories complete all as specified and directedby Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F in replacement of OFF Load Change Change over ( Side Handel) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 400 Amps with connecting acessories complete all as specified and directedby Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F in replacement of OFF Load Change over ( Side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 630 Amps with connecting acessories complete all as specified and directed by Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F in replacement of OFF Load Change over ( Side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 1000 Amps with connecting acessories complete all as specified and directed by Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F in replacement MCCB 63 Amp 4 Pole of rupturing capacity 25 KA complete all as specified and directed by Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F in replecement MCCB 100 Amp 4 Pole of rupturing capacity 16 KA complete all as specified and directed by Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F in replacement MCCB 125 Amp 4 Pole of rupturing capacity 16 KA complete all as specified and directed by Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F in replacement MCCB 160 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with thermal & adjustable magnetic setting complete all as specified and directed by Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
S&F in replacement MCCB 200 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with thermal & adjustable magnetic setting complete all as specified and directed by Engr-in-Charge. Make: Legrand/Schneider/Siemens/ABB/L&T
M&L for PCC 1:4:8 Type D2 using 40mm graded aggregate for base foundation complete all as specified and directed by Engr-in-Charge.
M&L for PCC (1:3:6) type C-1 with 20 mm gradded stone aggregate for copping of poles Pedestal (PCC) or mass filling complete all as specified and directed by Engr-in-Charge.
M/S MALIK CHAND SIRI RAM
Gyamdu Engineering Works
M/S BETONG CONSTRUCTION CO
SUMEET TRADING CORPORATION
Horizon Construction Company
M/S LEO TRADERS
Hitech Erectors Pvt. Ltd.
R B TRADERS
M/S BALI CONSTRUCTIONS
darshan kumar gandhi
Mehar Enterprises
CHHIRPON BUILDERS
N K BUILDERS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .