Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAccepted-AOC | ₹3.0 Cr | L1 | Accepted-AOC Awarded Contract Bidder |
| 2 | Rejected-Technical | - | - | Rejected-Technical As per the decision of Bid Evaluation Committee. |
| 3 | Rejected-Technical | - | - | Rejected-Technical As per the decision of Bid Evaluation Committee. |
Tender Value
₹3.9 Cr
EMD Value
₹7.9 L
Closing Date
4 Jun 2022, 2:00 pmClosed
Chief Engineer,(EAP) PWRD,Assam
O/o The Chief Engineer,(EAP) PWRD,Assam Fatasil Ambari,Guwahati- 781025
APART/NOCP/WAREHOUSES/SIV-01 Renovation and Up-gradation of Warehousing Facilities in existing Warehouse complex (Godown 1 and Godown 7) at Sivasagar District under APART.
2022_PWRDW_25370_6
CE/APART/21/2022/27
Open Tender
Civil Works - Building
Lump-sum
360 days
Sivasagar District
Please refer Tender documents.
6 documents required · 6 mandatory
₹8,000
₹7.9 L
Yes
O/o The Chief Engineer,(EAP) PWRD,Assam
31 Aug 2022
2 May 2022
4 Jun 2022
2 May 2022
4 Jun 2022
2 May 2022
2 May 2022 - 12 May 2022
12 May 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil.
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kind of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (b).Brick on edge soling.
RETROFITTING WORKS Chipping and breaking / cutting of loose concrete, mortars etc. using electrical chipping hammers to the satisfaction of the Engineer-in charge for successful execution of the subsequent rehabilitation works at all heights with all leads, lifts etc complete with all tools and machineries required for the job , operator, applicator, labour, scaffolding for staging and supervision etc.
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
ANTI - TERMITE TREATMENT Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Along external wall where the apron (existing) is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.
Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(Zone III) : 4 graded stone aggregate 12.5mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundation, footings, bases of columns
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement : 4 coarse sand)
RANDOM RUBBLE MASONRY Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (c).Stone soling of thickness 150mm.
FLOORING Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick.
ROOFING Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm).
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Barge board (Upto 300 mm).
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester to Crimp curve
Extra for crimp at eave of colour coated zinc-aluminium roof , wall and tile profile sheet accessories (total coating thickness=0.5mm) including fasteners class 2 SDS, fitting and fixing complete. (Roof trusses, purlins etc. to be measured and paid separately.) Crimped Eave
FINISHES 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
PLASTER OF PARIS & WALL PUTTY Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
PAINTING ON STEEL AND OTHER METAL SURFACE Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work.
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Steel Work Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
REBAR ANCHORING Supply and fixing of rebaring chemical Fosroc LOKFIX E75/Hilti RE500 V3 or equivalent - Pure Epoxy Chemical anchor to grout various diameters of reinforcement bar at provided embedment depth upto 100mm or as per the manufacturer's specifications and as directed by Engineer in charge. (Cost of the reinforcement will be paid extra) iii) 12 mm diameter of reinforcement bar as per embedment depth.
REBAR ANCHORING Supply and fixing of rebaring chemical Fosroc LOKFIX E75/Hilti RE500 V3 or equivalent - Pure Epoxy Chemical anchor to grout various diameters of reinforcement bar at provided embedment depth upto 100mm or as per the manufacturer's specifications and as directed by Engineer in charge. (Cost of the reinforcement will be paid extra) 10 mm diameter of reinforcement bar as per embedment depth..
Supply and fixing of rebaring chemical Fosroc LOKFIX E75/Hilti RE500 V3 or equivalent - Pure Epoxy Chemical anchor to grout various diameters of reinforcement bar at provided embedment depth upto 100mm or as per the manufacturer's specifications and as directed by Engineer in charge. (Cost of the reinforcement will be paid extra) For 16mm Dia Reinforcement (Column)
Supply and fixing of rebaring chemical Fosroc LOKFIX E75/Hilti RE500 V3 or equivalent - Pure Epoxy Chemical anchor to grout various diameters of reinforcement bar at provided embedment depth upto 100mm or as per the manufacturer's specifications and as directed by Engineer in charge. (Cost of the reinforcement will be paid extra) v) 20 mm diameter of reinforcement bar as per embedment depth.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Providing and fixing bolts including nuts and washers complete. Electric resistance or induction butt welded tubes.
STEEL AND IRON WORKS Providing and fixing bolts including nuts and washers complete
backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete 20mm dia (1000 mm long)
PLINTH PROTECTION Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth.
DISMANTLING AND DEMOLISHING Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Dismantling wood work in frames, trusses, purlins and rafters including stacking the materials as directed by the department for all levels.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge.
Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flats Ventilators
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. Truss main building Verandah
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. (i) Area of door/window up to 3.00 m2
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres
Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/ bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).
PLINTH PROTECTION DRAIN Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. i) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Poviding and applying two coats of two component epoxy zinc rich primer like Fosroc Nitozinc Primer or equivalent on the properly cleaned reinforcement after the required chipping and cleaning of the concreate surface as per the manufacyure’s specification at a dry flim thickness of 40 micron /coat.The epoxy zinc rich primer should have a adhesive bond strength with steel greater than 1.5 N/Sqm.Make:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Providing and placing free flow micro concrete of approved brand after fixing slurry tight shuttering. The microconcrete shall contain no metallic aggregates, or chlorides and shall be shrinkage compensated in the plastic state.The micro concrete in the flowable consistency should achieve a compressive strength of not less than 10N/mm2 after 24 hours, 40N/mm2 after 7 days and 50 N/mm2 after 28 days at 30ºC. Most importantly, the cured microconcrete shall contain no metallic aggregates, or chlorides and shall be shrinkage compensated in the plastic state. The unrestrained expansion shall be between 1 - 4%. The flexural strength shall not be less than 5 N/mm2 @ 28 days. The microconcrete shall have a coefficient of thermal expansion similar to that of the host concrete. The mixed density of microconcrete shall exceed 2100 kg/ m3 at 27ºC.Make:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Providing and Sealing the cracks, in the concrete surface, after opening the cracks using suitable tools or saw cut in the crack, and cleaning the interior sides of the crack using sharp tools to remove all loose materials, using two component, high strength, non- sag, epoxy compound like Nitobond PC40 or equivalent inclusive of all Manpower, Material and Equipment. Injection Of Low Viscous Resin: BY Providing and grouting the cracks after fixing the injection ports at predetermine locations with the help of suitable injection grouting pumps at suitable pressures using two- component, high strength, low viscous epoxy resin system grout like Conbextra EP10 or equivalent.(inclusive of Manpower, Material and Equipment). Make:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Drilling 12 mm dia X100 mm hole in to the concreate surface using concreate hammer drill machine. Providing 10mm PGMs nozzles is gird of 0.25 m both and injecting cement slurry Injecting cement slurry 1:3 ( 1 Cement: 3 water ) by weight including mixing of grout compound as per manufacture specifications , in cracks/ effected approved brand till completion and refusel of gout complite as per manufactures specification. The nozzles are to be sealed off after grouting using rapid setting cement based pluging mortar of approved brand.Make:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Crack opening should be chiselled out to approximately 20mm X 20mm , and should always be undercut to avoid formation of a V shape and cut back to a minimum depth of 15 mm and given a good mechanical key to apply Single part, non shrink, cementitious, crack sealer like Fosroc Renderoc CS or equivalant for plaster, masonry and concrete as per manufactures specificationMake:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
Providing and Applying a two component structural grade polymer modified reinstatement mortar of approved brand up to a thickness of 10 mm over a epoxy rasin bonding agent like Fosroc Renderoc S2 or equivalent. The cured mortar shall achieve a compressive strength of 12 N/mm² in 1 day & 45 N/mm² in 28 days with Flexural strength 8 N/mm² in 28 days. Chloride diffusion coefficient shall be Nil after 24 hours when tested by Accelerated Electrochemical chloride ion diffusion test method and the depth of carbonation shall be Nil after 24 hours when tested by Accelerated carbonation test. In addition to this percentage of water absorption should be 0.45 after 24 Hrs in immersion testMake:- Fosroc/ Sika/ Dr. Fixit/ BASF/ Choskey
TURBO VENTILATOR Supplying, fitting and fixing in position turbo ventilator of Nylon made Typhonic Bearing, double top cap ensured permanent alignment in inverted cap design, corrugated foil framed of aluminium fabrication for wind driven having wind velocity 1600 exauster of effective throatal Dia 21 inch and overall dia 28 inch having overall height 17 inch as specified and directed by the Engineer-in-charge.
LOUVERS Providing & fixing louvers of size (450mmx300mm) at all heights with all leads- 3.5 mm thick toughened frosted glass louvers, 25 micron anodized aluminum sections for louver manufactured from best extruded aluminum sections from approved manufactures, the frame work fixed of jindal sections of minimum anodic coating of grade AC 15 with standard approved fastenings or hinges as per details specifications with all the sections pretreated for removal of any rust and prevention of any further rust, M.S. Grill of required size, one primary coat of red-lead/red oxide primer and two coats of enamel paint of approved brand and manufacture all complete as per specifications and direction by the Engineer-in-charge.
VDF Providing VDF flooring for top coat of floor with dewatering of concrete by vaccum pump and sprinkling non-metallic floor hardner @ 5 kg/sqm followed by a coat of cement slurry mixed with Nitobond SBR latex or equivalent @ 1 kg over 1.25 sqmtr and 67 ml. Nitobond SBR latex. Over the levelling reinforeced cement concrete base 1:1.5:3 simulteniously casted as per specification. 10mm x 12mm groove @ 5 mtr. or equally distributed pattern to be cut and filled with Polysulphide Sealent as grouting compound. Complete and finished in all respect as per company specification and Engineer-in-charge. (The R.C.C. work will be measured and paid separetly)
UREA CORROSION RESISTANCE COATING Providing and applying a chemical and abrasion resistant, high build, two-pack epoxy-novolac system specially designed to provide a tough and impermeable high chemical resistant film at a thickness of 500 micron. The coating should able to resist wide range of chemicals both acid and alkaline having pH value 1 to 14. The cured flim should have Tensile strength 30 N/mm², Elongation 3%, flexure strength 45 N/mm², Compresive strength 95 N/mm².
RECRON 3S Extra over Analysis Item C10. Providing Recron 3S shall be mixed with the approved concrete and laid over prepared subbase. The work shall be carried out as per direction by Engineer-in-charge. The materials, loading, unloading, transporting to site, removing rubbish from site, all taxes etc. complete for all lead and lift. VDF concrete
Fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates (in columns and trusses), bolts and nuts complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed.
Supplying materials and laying 25 mm thick self adhesive closed-cell nitrile elastomeric rubber insulation foam with non-porous composition, aluminium foam on one side, high thermal efficiency as well as protection from imminent condensation problems.The product should be environmental friendly and zero Ozone Depletion Potential (ODP). The self adhesived sheets are to be cutted in required size and shape should be fixed with necessary screws and rubber washers fixed to the truss members on both the direction. Including necessary accessories for fitting and fixing of sheet in position as complete as per the instruction of Engineer In Charge. The basic property of the material should be as follows : Fire rated “CLASS O” as per BS 476 Parts 6 & 7; Water vapour permeance (0 perms); Water vapour diffusion factor (> 10,000); Water absorption rate (0.06% by volume); Thermal efficiency (λ24˚ C = 0.033 W/mK; λ46˚ C = 0.036 W/mK); Temperature range (from -50˚ C to +105˚ C); Antibacterial & antifungal; Environmental friendly – ODP = 0; Low VOC emission level
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Primary Point wiring in PVC conduit, with piano type switch - Wiring for light point / fan point / exhaust fan point / call bell point ( for door call bell only ) with 1.5 Sq.mm FRLS PVC insulsted copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch ,recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Conduit Make : Anchor / Richa or equivalent as approved. Wires : FR /FRLS - Finolex, RRKable, Anchor,Polycab, Havels or equivalent as approved. Group B
UNDER GROUND CABLE WORKS Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.. Make ; RR Kable, Havells, Polycab, KEI Or equivalent as approved 3 Core, 6 sq.mm. XLPE ARMOURED Aluminium Cable. Form transformer to MDB
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
Supply and Installation of 1400 sweep powerful double bearing ceiling fan. Make ; Oirent Summer breeze or equivalent Havells or Panasomic make as approved. For dining hall
Supply of 150mm high spped exhaust fan having automatinc lovour shutter . Make ; Oirent Ventilator HS or equivalent Havells or Panasomic make as approved. For toilets
1 x 20/18 W LED T8 tube light fitting with drive and frame Make ;SSK T5 12W Siska COB DLC or equivalent CGL/ Havells/ Surya as approved. For study table lamp.
Supply, installation , and electrical connectin of an angle holder with 12W NW LED BULB for toilet and dressing room as directed
3 Core, 6 sq.mm. XLPE ARMOURED Aluminium Cable. Form transformer to MDB
Construction of 400mm x 400mm x 400mm masonry manhole with air tight C.I. Cover requires for earthing point to cover.
Wiring for 15/16A light/power plug for power point with 2x4 Sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No. 4 Sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 150mm X 75 mm X 60 mm deep
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.FOR DOOR CALL
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. Make ; Havells/ Panasonic/ Schneider or equivalent as approved. 5/6 amps piano type switch and 3 pin 5/6 amp socket outlet for existing switch borad.as directed.
Circuit / submain /Light plug wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required. Wires : FR /FRLS - Finolex, RRKable, Anchor,Polycab, Havels or equivalent as approved 2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) For 6 way, Double door SPN MCBDB for srcurity booth, waiting area and toilets
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) For 8 way, Double door SPN MCBDB for office 2
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing following rating, pole, , MCB Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. For room DB 40 amps DP 240 V -
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required for rooms and media room. 40A
Common Light Point wiring in Steel conduit - Wiring for common light point / fan point wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in recess or surface Steel conduit ( to be fitted with the truss member by sport welding ) as required.. Make : conduit as approved by CA, Wires : FR /FRLS - Finolex, RRKable, Anchor, Havels or equivalent as approved. 2 x 1.5 Sq.mm + 1 x1.5 Sq.mm earth wire for common light point wiring from Primary point to two nos. secondary points as shown in the drawing
Supplying and fixing following piano type switch and socket on the existing switch box/ cover including connections etc. as required as directed. 3 pin 5/6 A socket outlet
Supplying and fixing following piano type switch and socket on the existing switch box/ cover including connections etc. as required as directed. 5/6 amps switch for light power point as directed.
SUB MAIN WIRING FROM SPN DB TO SB Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required ( from SPN DB to Switch boards ) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
SUB POWER DISBTIBUTION BOARD FOR GF Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without MCB / RCCB and incomer) as required.- for each floor power distribution for rooms. 12 - way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral (16 KA)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
CEILING & EXHAUST FAN Installation, testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Earthing Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia cover plate having locking arangement and watereing pipe with charcoal / coke andsalt as required for out door lighting system & indoor DBs. One for VTPN and 1 for washr room and 1 for cofee house .
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing of G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing of G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontall run)
Providing and fixing earth bus bar joint made of 20mmx3mm thick 125 mm long with 4 nos. G.I bolts , nuts, chuck nut and spring washers etc. complete as requried
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioC70:C80ning, protective covering and refilling the trench etc as required. Up to 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on surface of building walls addirected Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35sq. Mm
Supply and making cable end termination with brass compression glands and crimped aluminium lugs following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade of the following sizes as required. 2 X 6 sq. mm (19mm)
Misecellineous Items - GI Pipes Supplying and embedding following G.I pipe of medium class for cable entry / road crossing of cable etc. including bending the pipe as required shape as required. a) 32 mm dia
Supplying of following LED lighting fixtures complete with Drive and Lamps with reflector/cover etc. complete as required:- Make : Sisk / CGL/ Havells/ Surya or Panasonic as approved 1 x 20 W LED 6500K retrofitting polycarbinateT8 tube with in built driver and heat sink double sided connection with compact commercial batten suitable for T8 LED tube Make ;CGL Cat Ref. LT820865 and for batten unilite DMLN1LT8-16 or equivalent Siska or Havells , phillips, bajaj as approved. for small class room lighting
Installation, testing and commissioning of prewired, flourescent fittings / all type of LED indoor ceiling fittings complete with all accessories and tube etc
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing, commissioning etc. as required.
Construction of 400mm x 400mm x 400mm masonry manhole with air tight C.I. Cover requires for earthing point to cover.
Supplying, Installing and commissioning of On-grid 10kW Solar powered system of the following capacity including basic AC cableing, Lightning Arrester, LA Clamp with 6 sqmm solar cable, supporting structure and additional accessiories complete with making necessary connection SPV Panels: 395 watt peak Solar modules (Mono) (26nos.) PCU: 10 kW On Grid Inverter (1nos.) ACDB: 10KW (1nos.) DCDB: 10KW (1nos.) Electrical Earthing (3sets) Lighting Arrester with clamps: (2nos.) SPV Panels 395 watt peak Solar modules each (Mono) as approved, specified and directed by the Engineer. (Civil works in support structure & Electric panel to be measured & paid separately)
Supplying, Installing and commissioning of Closed Circuit Television system of the following capacity including Supply and Laying of 2 Core 2.5 Sqmm Electrical Wire in PVC Conduit, Casing/ Caping with Supply & Installation of 6U & 17/18U Floor Mounted Equipment Rack complete with making necessary programming/ connections as approved, specified and directed by the Engineer. 4mp Dome Camera. 1/3" Progressive CMOS, ICR, Colour: 0.01 Lux @(F1.2; AGC ON), 0lux with IR, 2688x1520:25fps(P)/ 30fps(N), H.265+/H.265/H.264/ MJPEG, DC12V & PoE, WDR, 3D DNR, BLC, HLC, 5 VCA, IR range: up to 40m, HIK-Connect cloud service: (3Nos) 4mp Bullet Camera. 1/3" Progressive CMOS, ICR, Colour: 0.01 Lux @(F1.2; AGC ON), 0lux with IR, 2688x1520:25fps(P)/ 30fps(N), H.265+/H.265/H.264/ MJPEG, DC12V & PoE, WDR, 3D DNR, BLC, HLC, 5 VCA, IR range: up to 40m, HIK-Connect cloud service: (32Nos) 4MP Varifocal Camera. 1/3" Progressive Scan CMOS; H.265+/H.265/H.264+/H.264/MJPEG; Colour: 0.01 lux @(F1.2, AGC ON), 0 lux with IR; 25fps/30fps(2560x440, 1920x1080); 3 VCA functions; 3 streams; 3D DNR; ICR; EXIR, up to 50m; DC12V&PoE; Built-in micro SD/SDHC/SDXC slot; HIK- Connect cloud service: (11Nos) ANPR camera [Deep learning] 2MP smart monitoring camera, 1/1.9 Progressive Scan CMOS, 1920x1080 60fps/50fps; Lens:5.3-13mm: (2Nos) NVR 32Mbps Bit Rate Input Max(up to 64-ch IP video), 8 SATA interfaces, alarm I/O: 16/4, 2U case,19": (1Nos) 16 channel Gigabyte PoE Switch L2, Unmanaged, 16 Gigabit POE ports, 1 Gigabit RJ45 uplink port, 1 Gigabit SFP uplink port, 802.3af/at, PoE power budget 230w: (4Nos) Surveillance Grade Hard Disk Drive. ST6000VX001,6TB,5400,3.5": (8Nos) 4K LED Display of 55inch (min) with build-in speaker, view angle 178deg, plastic casing, VESA, 7*18h">55" 4K, HDMI*2, VGA*1, USB2.0, USB3.0: (1Nos)
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks)
EXTERIOR PAINTS / COATINGS Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound@ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
DISTEMPERING Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade.
PVC PIPES,BENDS,JUNCTIONS,TEES ETC. Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (iv)75MM
Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood
Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
CHOWKATHS Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). (a) With sal wood
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES Applying priming coat : With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with oil type wood preservative of approved brand and manufacture: New work (two or more coats)
Supplying, installation, testing and commissioning of follownig specifications and as per the relevent IS code of practice [IS 2190-2010 [ANNEX B] (Clause 5.3)]. A) 6 kg ABC fire extinguisher ( Class-A, Occupancy-Medium Hazard)
Supplying, installation, testing and commissioning of follownig specifications and as per the relevent IS code of practice [IS 2190-2010 [ANNEX B] (Clause 5.3)]. B) 25 kg ABC fire extinguisher ( Class-A, Occupancy-High Hazard)
ALUMINIUM FITTINGS Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 300x10 mm
Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
A provisional sum of Rs. 7,71,000.00 (Rupees Seven lakhs Seventy One Thousand only) for ESMP requirements is provided and to be operated and expended in whole or in part as per the instruction of Engineer.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .