| Sl No | Description | Qty | Unit | M/S HILAL ENTERPRISES L2 | MUKHTAR ELECTRIC WORKS L6 | M/S TANTRAY ELECTRICALS L3 | M/s ELITE ELECTRICALS L1 | M/S ALJAN ENGINEERS AND CO L4 | M/S WATT ELECTRICAL CONTRACTS L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and Erection of 13mtr Long ST Pole with base plate and top cap (ST-410 SP69 ) including excavation of pit and back filling by boulders upto 1ft as per REC standards | 30 | No | 38,500 ₹11,55,000 | 47,000 ₹14,10,000 | 32,500 ₹9,75,000 | 31,000 ₹9,30,000 Lowest | 39,000 ₹11,70,000 | 35,121 ₹10,53,630 |
| 2.00 | Supply and Erection of 11mtr Long ST Pole with base plate and top cap (ST-410 SP56 ) including excavation of pit and back filling by boulders upto 1ft as per REC standards | 110 | No | 29,500 ₹32,45,000 | 30,000 ₹33,00,000 | 28,200 ₹31,02,000 | 30,000 ₹33,00,000 | 35,000 ₹38,50,000 | 25,121 ₹27,63,310 Lowest |
| 3.00 | Providing and fixing of GI V cross-arm duly fabricated with top Bracket including clamp as per site requirement and REC standardsfor 33kV network | 4,500 | kg | 119.5 ₹5,37,750 | 145 ₹6,52,500 | 165 ₹7,42,500 | 124 ₹5,58,000 | 106 ₹4,77,000 Lowest | 171 ₹7,69,500 |
| 4.00 | Providing and fixing of GI channel/Angle duly fabricated with clamp and brace as per site requirement and REC standardsfor 11kV network | 2,000 | kg | 119.5 ₹2,39,000 | 145 ₹2,90,000 | 145 ₹2,90,000 | 124 ₹2,48,000 | 100 ₹2,00,000 Lowest | 171 ₹3,42,000 |
| 5.00 | Providing and fixing of GI channel/Angle duly fabricated with clamp and brace as per site requirement for existing 11kV/LT network | 1,400 | kg | 119.5 ₹1,67,300 | 145 ₹2,03,000 | 110 ₹1,54,000 | 124 ₹1,73,600 | 100 ₹1,40,000 Lowest | 171 ₹2,39,400 |
| 6.00 | Provding,Laying,stringing ,tensioning and binding of 0.2 ACSR Conductor (PANTHER) as per REC standards | 10 | km | 2,42,800 ₹24,28,000 | 2,70,000 ₹27,00,000 | 2,65,000 ₹26,50,000 | 1,90,000 ₹19,00,000 Lowest | 2,45,000 ₹24,50,000 | 2,51,212 ₹25,12,120 |
| 7.00 | Providing and fixing of PG clamps suitable for 0.2ACSR as per REC standards | 200 | No | 550 ₹1,10,000 | 150 ₹30,000 Lowest | 250 ₹50,000 | 200 ₹40,000 | 250 ₹50,000 | 375 ₹75,000 |
| 8.00 | Supply,installation,testing and commissioning of 33 kV Polymeric composite Pin Insulator(36kV,10kN, Lighting Impulse 170KV positive and 180kV negative) suitable for for 0.2ACSR of reputed make as per REC standards | 400 | No | 549 ₹2,19,600 | 1,050 ₹4,20,000 | 720 ₹2,88,000 | 500 ₹2,00,000 Lowest | 550 ₹2,20,000 | 777 ₹3,10,800 |
| 9.00 | Supply,installation,Testing and commissioning of 33 KV DISC Insulators ( 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) complete with tension fitting suitable for for 0.2ACSR of reputed make as per REC standards | 180 | No | 900 ₹1,62,000 | 1,550 ₹2,79,000 | 800 ₹1,44,000 | 600 ₹1,08,000 Lowest | 900 ₹1,62,000 | 1,786 ₹3,21,480 |
| 10.00 | Providing and fixing of GI Nuts & Bolts of sorts as per site requirements | 220 | kg | 105 ₹23,100 Lowest | 150 ₹33,000 | 170 ₹37,400 | 120 ₹26,400 | 110 ₹24,200 | 110 ₹24,200 |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
15 Jul 2024, 2:30 pmClosed
THE EXECUTIVE ENGINEER STD 2ND RAJBAGH
OFFICE OF THE EXECUTIVE ENGINEER STD 2ND RAJBAGH
Construction of 33kV Line from Sukhnag upto Receiving Station Arizal as a Tie Line between Grid Station Budgam and Grid Station Ahmadpora (Part B)
2024_PDD_250988_1
eNIT No STD-II / 17 of 2024-25 Dated 20-06-2024
Open Tender
Electrical Works
Turn-key
90 days
BUDGAM
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
THE EXECUTIVE ENGINEER STD 2ND RAJBAGH
₹2 L
28 Oct 2024
24 Jun 2024
16 Jul 2024
24 Jun 2024
15 Jul 2024
1 Jul 2024
Amount
Supply and Erection of 13mtr Long ST Pole with base plate and top cap (ST-410 SP69 ) including excavation of pit and back filling by boulders upto 1ft as per REC standards
Supply and Erection of 11mtr Long ST Pole with base plate and top cap (ST-410 SP56 ) including excavation of pit and back filling by boulders upto 1ft as per REC standards
Providing and fixing of GI V cross-arm duly fabricated with top Bracket including clamp as per site requirement and REC standardsfor 33kV network
Providing and fixing of GI channel/Angle duly fabricated with clamp and brace as per site requirement and REC standardsfor 11kV network
Providing and fixing of GI channel/Angle duly fabricated with clamp and brace as per site requirement for existing 11kV/LT network
Provding,Laying,stringing ,tensioning and binding of 0.2 ACSR Conductor (PANTHER) as per REC standards
Providing and fixing of PG clamps suitable for 0.2ACSR as per REC standards
Supply,installation,testing and commissioning of 33 kV Polymeric composite Pin Insulator(36kV,10kN, Lighting Impulse 170KV positive and 180kV negative) suitable for for 0.2ACSR of reputed make as per REC standards
Supply,installation,Testing and commissioning of 33 KV DISC Insulators ( 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm) complete with tension fitting suitable for for 0.2ACSR of reputed make as per REC standards
Providing and fixing of GI Nuts & Bolts of sorts as per site requirements
Providing and fixing of danger plates with clamps as per REC standards
Providing and fixing of anti climbing devices with clamps as per REC standards
Providing and fixing of earthing of ST poles Complete by GI Pipe 40 mm 3mtr long through GI Strip(25x8mm)
Providing and Painting of 13/ 11 mtr long ST Poles with one coat of red oxide and two coats of aluminum paint to give even shade.
Providing and laying of Cement bottoming of 13mtr long ST Poles in mix 1:2:4 using 20mm crush stone aggregate including shuttering ,form work etc. as per REC standards .7cum /pole
Providing and laying of Cement bottoming of 11 mtr long ST Poles in mix 1:2:4 using 20mm crush stone aggregate including shuttering ,form work etc. as per REC standards .6cum /pole
Providing and fixing of Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete
Providing and fixing of 16kN Polymer Shackle insulator including GI Mukki Clamps including nuts and bolts for exiisting LT network as per REC standards
Providing and fixing of Guard Netting as per REC Standards
Supply,installation,testing and commissioning of 11kV Polymeric composite Pin Insulator with pins (12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm) of reputed make
Supply Installation, Testing & Commissioning of 11kV Polymeric composite Disc Insulator (12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm) wth fittings of reputed make
Extensive Branch cutting of trees including chopping of trees coming in the coridor of 33KV line and stacking of serviceable material and disposal of unservicable material.(complete job)
Shifting of existing 0.05/0.1 ACSR of LT/HT Lines whereever required on 11/13 metre long poles including stringing ,tensioning and binding of the same as per REC standards (complete job)
M/S HILAL ENTERPRISES
M/S TANTRAY ELECTRICALS
M/S ALJAN ENGINEERS AND CO
M/S WATT ELECTRICAL CONTRACTS
MUKHTAR ELECTRIC WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .