Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.9 LAccepted-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹21.2 L+₹5.3 L (33.0%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹21.4 L+₹5.5 L (34.5%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹28.4 L+₹12.4 L (78.1%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST | |
| 5 | Rejected-Technical 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | - | Rejected-Technical Rejected due to remark No, Slow progress in WLR |
Tender Value
₹30.0 L
EMD Value
₹59,980
Closing Date
29 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PALAM DELHI CANTT
GE (AF) PALAM DELHI CANTT-10
REPAIR / REPLACEMENT OF FLOOD LIGHT, AVIATION LIGHT, TRAFFIC LIGHT AND TARMAC LIGHTS IN AREA OF AGE E/M-I UNDER GE (AF) PALAM, DELHI CANTT-10
2022_MES_532769_1
GENP-35/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM
₹59,980
Yes
24 Apr 2023
22 Jun 2022
30 Jul 2022
22 Jun 2022
29 Jul 2022
8 Jul 2022
Amount
Taking down unserviceable light fittings from the tarmac/ dispersal / taxi track by removing glass cover and checking the unserviceable parts like copper wire, capacitor ,control gear box ,contactor,copper ballast , electric driver, lamp,ignitor, states of servicability etc and re-fixing the fittings back to its original position after carried out all necessary repairs to make the fitting serviceable.( Note:- The spare parts to be replaced shall be measured and paid separately under respective items here-in- after).
Taking down unserviceable light fittings from the high mast by lowering the high mast by winch & motor including checking the unserviceable parts like electronic driver copper wire link unservice hight mast light , overhaling rope wire , rope wire nut bolt , clamp etc and re-fixing the fittings back to its original position after carried out all necessary repairs to make the fitting serviceable.( Note:- Light fitting, connecting wire , driver etc to be replaced shall be measured and paid separately under respective items here-in- after).
Supply only in replacement of super imposed copper ballast 150 watt for SV fitting .
Supply only in replacement of super imposed copper ballast 250 watt for SV fitting .
Supply only in replacement of super imposed copper ballast 400 watt for SV fitting .
Supply only in replacement of lamp SON lamp tubular 150 Watt.
Supply only in replacement of lamp SON lamp tubular 250 Watt .
Supply only in replacement of lamp SON lamp tubular 400 Watt.
Supply only in replacement of ignitor short distance suitable for MH/HPSV fitting of 400/250/150/70 watt.
Supply only in replacement of ignitor Long distance suitable for MH/HPSV fitting of 400/250/150/70 watt .
Supply only in replacement of Capacitor 42 MFD suitable for 400 watt SV/MH lamp.
Supply only in replacement of Capacitor 33 MFD suitable for 250 watt SV/MH lamp.
S&F in replacement of LT 3 phase 4 wire 415 volts transparent Kiosks cubical pole box moulded in single piece of size 300mmx200mmx100mm, shock proof, rust proof, fire retardant with 4 Nos aluminium bus bar of capacity 100 Amps mounted on DMC unbreakable insulators complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of electronic driver for LED flood light 100/120 watt as per existing Flood light model complete .
Supply only in replacement of electronic driver for LED flood light 150/250 wattas per existing Flood light model complete .
S&F in replacement of Traffic light LED type red/green/white/Blue/Orange, 24 hrs operation 300 mm round light source ,visibility> 500 mtrs ,operating voltage 230 Volt AC complete with poly carbonate enclosure and clear diffuser complete.
S&F in replacement of LED Aviation 6 W Obstruction Light with yellow painted die cast aluminium alloy housing with polycarbonate enclosure complete.
S&F in replacement of LED Aviation 2 X 6W Obstruction Light with yellow painted die cast aluminium alloy housing with polycarbonate enclosure complete.
S&F in replacement of analog type time switch 3P module, DIN 24 hours programmable every 30 minutes of current capacity 16 Amps with one change over including connecting to existing power contactor complete .
S&F in replacement of digital type type time switch 3P module, DIN 24 hours programmable every 30 minutes of current capacity 16 Amps with one change over including connecting to existing power contactor complete .
Supply and fixing in replacement of Power contactor 40 A, 4 pole of timer panel.
S&F in replacement of LT panel analog type auto time switch distribution panel board with 3 pole power contactor 32/40 Amps, and time switch, on/off switch, indicator and control wiring with one 4 pole MCB 40 Amps complete.
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out /laying cable, poles & stay etc complete all as specified and as directed by Engr-in-Charge.
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete.
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete.
M&L for sand cushioning to under ground cable provided with layer of sand (8 cm deep before laying the cable and 15 cm deep after laying the cable i.e total 23 cm and after compaction 18cm thickness).
M&L for brick of burnt clay sub class ‘B’ laid dry flat in trenches for cable protection.
Taking out old unserviceable LT under ground cable of any type/ size from trenches, pipes & poles complete.
Supply and fixing LT Cable XLPE insulated under ground 1100 Volt grade with stranded aluminium conductor of size 16 Sqmm 4 core in trenches /passing through pipes/ on poles etc complele all as specified and directed.
Supply and fixing LT Cable XLPE insulated under ground 1100 Volt grade with stranded aluminium conductor of size 25 Sqmm 4 core in trenches /passing through pipes/ on poles etc complele all as specified and directed.
Supply and fixing LT Cable XLPE insulated under ground 1100 Volt grade with stranded aluminium conductor of size 50 Sqmm 3.5 core in trenches /passing through pipes/ on poles etc complele all as specified and directed.
S&F in replacement of LED flood light fitting 100 watt with internally prewired incl electronic driver and connecting up with three core flexible copper conductor 1.5 Sqmm cable complete all as specified and directed.
S&F in replacement of LED flood light fitting 120 watt with internally prewired including electronic driver and connecting up with three core flexible copper conductor 1.5 Sqmm cable complete all as specified and directed.
S&F in replacement of LED flood light fitting 150 watt with internally prewired including electronic driver and connecting up with three core flexible copper conductor 1.5 Sqmm cable complete all as specified and directed.
S&F in replacement of LED flood light fitting 200 watt with internally prewired including electronic driver and connecting up with three core flexible copper conductor 1.5 Sqmm cable complete all as specified and directed.(for High mast lights).
S&F in replacement of LED flood light fitting 250 watt with internally prewired including electronic driver and connecting up with three core flexible copper conductor 1.5 Sqmm cable complete all as specified and directed.(for High mast lights).
Supply and fixing in replacement of high efficient LED flood light fitting with thermal management and equipped with IP66 protection of 300 Watts complete with driver, control box and connection with suitable size copper wire etc complete.
S&F in replacement of control cable PVC insulated copper conductor 2.5 Sqmm 3 core complete.
S&F in replacement of control cable PVC insulated copper conductor 4.0 Sqmm 3 core complete.
M&L in replacement of PVC insulated service cable flat or round sheathed, aluminium, multistranded conductor 1100V grade size 16 Sqmm 2 core
All as per item No. 40 above but of size 10 Sqmm 2 core
All as per item No. 40 above but of size 6 Sqmm 2 core
Supply and fixing in replacement of electric motor 2 HP heavy duty capacity 415 volts 50Hz ,900 RPM with gear 100 mm dia and chain machanism suitable to existing system to drive the high mast light up and down complete all as specified and directed.
S&F in replacement of MCCB , 3 Pole, 125 Amps, 415 volts, 16 KA repturing capacity.
Supply and fixing in replacement of MCCB 63 A, 4 pole, 10 KA of timer panel complete all as specified and directed.
Supply and fixing in replacement of MCB TPN 40 Amp rating, 240V, 10KA,with connection testing and commissioning, complete all as specified and directed.
Supply and fixing in replacement of MCB, TP, 40 Amp rating, 240V, 10KA with connection testing and commissioning, complete all as specified and directed.
Supply and fixing in replacement of MCB, TPN, 63 Amp rating, 240V, 10KA with connection testing and commissioning, complete all as specified and directed.
Supply and fixing in replacement of MCB, TP, 63 Amp rating, 240V, 10KA with connection testing and commissioning, complete all as specified and directed.
M/s Adhikari construction co.
Commercial Traders
Surjit and Sons
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .