Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹32.0 L+₹70,649 (2.26%)Rejected-Finance SHOP NO 02 GROUND FLOOR SAMUDRIKA CHS PLOT NO 183 URAN RAIGAD MAHARASHTRA 400 702 | RAIGAD | MAHARASHTRA | 400702 | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹35.7 L+₹4.4 L (14.1%)Rejected-Finance | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹39.0 L+₹7.7 L (24.7%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L4 | Rejected-Finance Other than being lowest | |
| 5 | L5₹39.3 L+₹8.0 L (25.5%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L5 | Rejected-Finance Other than being lowest |
Tender Value
₹46.3 L
EMD Value
₹92,600
Closing Date
6 Apr 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
SPECIAL REPAIRS REPLACEMENT TO COOLING APPLIANCES AGAINST DECLARED BER AT VAJRABAHU BLDG NO (A 14 PA 33) YARD AT ND AND ADDITION AND ALTERATION AND SPECIAL REPAIRS TO STREET LIGHTS FROM LION GATE TO CRUSIER WHARF UNDER YAS DEPARTMENT AT NAVAL DOCKYAR
2024_MES_645968_1
8329/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) Kunjali
Class D
Category b (i)
7 documents required · 7 mandatory
₹500
GE (NW) Kunjali
₹92,600
Yes
3 Jun 2024
11 Mar 2024
8 Apr 2024
11 Mar 2024
6 Apr 2024
25 Mar 2024
11 Mar 2024 - 23 Mar 2024
Amount
Supply, installation and testing inverter based air cooled split type air conditioner, not less than 3 star rated, electric driven, single phase with capacity 1.5 Ton ( Non CFC gas ) , 230 volts, 50 Hz complete with all accessories including suitable size powder coated stand for both units, fixing arrangement as per manufacturers instructions, and testing for performance including provn of PVC drain pipe 20mm bore heavy duty as per site requirement including taking down old AC and depositing to BSO,GE(Kunjali) and making good disturbed surfaces as per existing complete all as directed by Engineer-in-Charge.
Supply and fix refrigerator, electric driven (single phase), capacity 195 Liters double door direct cool with inverter, energy efficient, toughened glass self , BEE 5 star rated , frost free, auto defrost tostop ice-build upof approved colour complete all as specified.
Supply and fix refrigerator, electric driven (single phase), capacity 310 Liters double door direct cool with inverter, energy efficient, toughened glass self , BEE 5 star rated , frost free, auto defrost tostop ice-build upof approved colour complete all as specified.
M & L for point wiring with 2.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable 1100 volts grade drawn through and including 25mm wide PVC casing caping (ISI marked) with all accessories and terminated in and including PVC modular box with modular cover plate and frame of sutable size including 2.5 sqmm size PVC insulated, unsheathed, multistranded FRLS copper conductor cable for continuous earth conductor for One 5pin, 16 Amps switch socket combination on indipendent board. Note: Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green
Supply and fix Switch piano, modular type 1 way 16 Amps 1 module 240 volts flush type complete all as directed.
Supply and fix modular socket 16 Amps 2/3 pin 240 volts combined 2 moduled all as specified and directed by Engr-in -Charge.
Supply and fix in repairs Single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240V 'C' curve complete all as specifid.
M&L for sub-main wiring with 2 runs of 4 Sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn through and including heavy grade PVC casing caping not less than 25 mm wide with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4 Sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) 2 runs of 4 Sqmm cable, One run of 4 Sqmm earth cable and PVC conduit shall be measured and paid as one length only.
Supply, fixing, clamping and jointing suitable size copper tubing for suction line and for liquid discharge line insulated with suitable insulation material as per manufacturers instructions including making hole in wall for passing through and making good disturbed surfaces as per existing complete all as specified.
Supply and fixing Rigid non-metallic heavy grade PVC conduit 20mm dia incl connecting to water cooler drain pipe including fixing accessories such as tees, bends,elbows, reducers, mouth tube ends etc. fixing on walls/roof with suitab;e size GI saddles, full threded screws and nylon rawl plugs etc complete all as specified and as directed.
Supply,laying,connect and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core passing through pipes/ fixed on wall duly clamped with suitable size of GI saddles with equal distance not upto 1 mtr including connecting properly by means of thimble complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair Distribution board timer panel limelite-65/63 A, 3 Pole/230V-Analog Time switch double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting including locking arrangement complete all as directed.
Material and labour for PCC 1:2:4 type B1( using 20mm graded stone aggregate) in foundation, road (below paver block) complete all as specified and directed.
Supply and fixing weather proof IP65 cable loop in loop out box complete all as specified and directed.
Supply and fixing MCB 5-40 Amps, SP 240V 'C' curve complete all as specified and directed.
Supply , fixing, testing in repairs of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( averaSchneider ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof complete all as specified . Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
Excavating in trenches, not exceeding 1.5 Mtr wide and not exceeding 1.5 m in depth for foundation, laying of cables etc and getting out in hard/dense soil complete all as specified.
Removing excavated material(soil) exc 50m and depositing where directed at a level n. exc. 1.5 Mtr above the starting point complete all as specified.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25cm depth in soil complete all as specified.
Material and labour for dry river sand as cushioning for protection of UG cable including punning of sand in layers complete all as specified. Note: Thickness after punning down shall be measured and paid
Supplying and laying un-reinforced precast concrete cable cover, class LV, type I, flat, size 250mm x 150mm x 40mm for protection of U/G cable laid in trenches complete all as specified and directed.
Supply and fixing Galvanised steel tubing, light grade, with fittings and MS clamps, nuts, bolts etc of 50mm dia bore for cable protection on pole, road crossing or ground in pillars for fixing gate light etc complete all as specified.
Material and labour for taking out carefully /interlocking tiles, demolition of PCC 15cm in depth including Road cutting in any type of soil for laying of pipes of width n.exc 0.6 mtr including filling soil watering and well ramming in layers and filling PCC and laying interlocking tiles removed as directed by Engineer-in-Charge. Note- PCC will be measured and paid separately.
BRICKS ON CLOUD INFRA
AIRDOT ENGINEERING
pk Enterprises
AGRAWAL ASSOCIATES
shubham construction
Vandan Enterprises
GANGAJAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .