Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC ROOM NO 145 MASJID WALI GALLI GANESH MURTI NAGAR PART NO 2 COLABA MUMBAI 05 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹15.1 L+₹1.6 L (11.6%)Rejected-Finance | L2 | Rejected-Finance Found in order but L2 | |
| 3 | L3₹16.2 L+₹2.7 L (19.9%)Rejected-Finance | L3 | Rejected-Finance Found in order but L3 | |
| 4 | L4₹17.0 L+₹3.5 L (25.8%)Rejected-Finance | L4 | Rejected-Finance Found in order but L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Desired documents not uploaded by your firm. |
Tender Value
Refer Docs
EMD Value
₹34,500
Closing Date
10 Mar 2025, 6:00 pmClosed
HQ CWE Meerut
29J The Mall Road Meerut Cantt Uttar Pradesh 250001
REPLACEMENT OF BER SUBMERSIBLE PUMP, SEWAGE PUMP AND CHLORINE DOSING PUMP AND PROVN OF LIGHTING CONDUCTORS OF 416 ENGR BDE CAMP UNDER GE (NORTH) MEERUT CANTT
2025_MES_697008_1
94179/MRT/2024-25/E8
Open Tender
Civil Works
Item Rate
120 days
Meerut Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (N) Meerut
₹34,500
Yes
26 Apr 2025
7 Feb 2025
14 Mar 2025
7 Feb 2025
10 Mar 2025
22 Feb 2025
Amount
Supply, installation, commissioning and testing of Submersible pumpset, comprising of 1 pump and 1 electric driven motor with following specifications 3 phase, 415 volts, frequency 50 Hz, delivery size 100 mm, head of around 60 metres , discharge of around 1800 LPM respectively, having multi stages, rotor and winding wires should be of copper,impeller, motor body and pump shaft should be of stainless steel and the sealing should be oil seal, should have sand fighter design to restrict the entry of sand in motor and pump, protect the pump and motor bushes to perform well in sandy borewells and increase the life of pumpset, should have CED (cathodic electro deposition) coating for corrosion resistance and uniform coating, should be suitable for 350 mm bore well. Note: The price to be quoted by the contractor must be including the cost of lowering all the connected column pipe and complete set and setting it to work, complete all as specified and directed. Make :- Lubi/Kirloskar/KSB
Supply and fixing MS steel column pipe (ERW) heavy duty of dia 150 mm, IS 3589 (1981), with both ends flanged complete with suitable size of bolts, nuts, washers, rubber packing, etc. complete all as specified and directed at site. Note: The price of suitable size of bolts, nuts, washers, rubber packing, etc.must be included in the rate quoted by the contractor.
Material and labour for submersible copper cable 3 core 16 sqmm multi stranded 1100 volts grade complete with connection including suitable size of copper thimble, nuts, bolts, washers and testing complete all as specified and directed. Note:- The price of suitable size ofcopper thimble, nuts, bolts, washers, etc.must be included in the rate quoted by the contractor. Make :- Finalex/Polycab/Havells/Grandly
Supply and fix fully automatic star delta starter of motor capacity 30 HP, 3 phase, 415 volts, complete with contactor, relay setting for protection against under voltage/ over voltage, short circuit, including testing, complete all as specified and directed.
Supply install testing commissioining non clog submersible centrifugal pump in 2MLD STP equilisation tank having dischage 42 M³ /Hr and head 25 M ,permissible solid size upto 100mm, SS impeller ,double mechanical seal,suction plate with support plate for stand,cast iron volute casing,support bracket/socket suitably grouted in equilisation tank base floor with duck foot bend,guide shoe , guide pipe adaptor, rubber diaphragm with suitable size single/double guide pipe made up of SS minimum thickness not less than 4mm,guide pipe holder etc pump should also have moisture sensor to indicate it in panel including of chain to pull the pump up ,coupled with suitbale size 3 phase squirrel cage induction motor in water tight housing IP68 as per IS 2147, class of insulation F, S1 duty cycle, working voltage 415± 10% ,frequency 50±5%,The capacity of motor shall be at least 15% in excess of BHP requirement of pump,stator housing, material of constuction CI duly painted,cable gland,cable protection tube, motor end cover ,eye bolt etc. The pump is provided with high and low liquid level controllers which avoids dry running of pump.Rate quoted is inclusive of suitable size multi core EBXL copper cable for motor and moisture sensor upto (40Mtrs) from motor to control panel star delt starter all as directed by Engineer-In-Charge. Contractor should submit TD sheet and drawing before sample approval.All the T&P,Transport,packaging included in quoted rate. Make:- Lubi/Kirloskar/KSB
M&L for cleaning and desilting the sewage equilisation tank of 2MLD STP at SRC location dewatering the complete, removing all the deposited sludge, soil and other material from the well including pumping out muddy water from the well by providing suitable pump sets from bottom level of well, scrapping out the scales / deposits from inner surface of the well thoroughly, washing with bleaching powder and soda ash, cleaning / bailing out settled materials completely by any means and removing sludge to a distance up to 3 km out side of defence land limit and dispose off in low lying area including dewatering as required for fixing support socket,guide pipe including taking down of existing sockets,guide pipe , delivery pipe if required making surface good with suitable class PCC to further grouting of new socket as recommended by OEM. Note:-(i) Contractor shall arrange his own diesel pump, T&P etc for cleaning purpose and minor spares and consumables like small screws, washers, grease, cleaning agents, Diesel & other consumables etc. and cost of the same shall deemed to be included in the quoted cost. (ii) The unit rate quoted shall deemed to be included draining of water with mechanical equipment and working in water and mud etc. (iii) The unit rate quoted shall deemed to be included All safety precautions which shall be taken while working in STP tank / under ground sump. (iv) Making good to the damages during the cleaning of the tank shall be sole responsibility of the contractor.
supply fixing fabricating MS pipe heavy class 'C' of size 150 mm including flanged complete with suitable size of bolts, nuts, washers, rubber packing, etc,reducer,bend for delivery pipe duly painted with two coat of enamel paint and zinc coated primer including cutting/ removing old unseviceable pipe complete all as specified and directed. Make:- Tata, Jindal,SAIL
Supply and fix pressure gauge 100mm dial UL listed polised stainless steel casing hardened glass window sealed against weather,moisture,dust, , range 1-10kg/sqcm burdon tube with brass moving part complete all as specified and directed.
Supply and fix dosing pump 2HP, 500LPH along with container and agitator complete all as specified and directed.
M&L Earthing with copper plate of size 60cm x 60cm x 3.15mm thick electrode and 20 x 3 mm copper strip as earthing lead, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level.connected to copper earth strip by means of bolts, nuts, check nuts and washers all as shown in electrical plate No 5 connected to earthing test points all as described in MES schedule Part I including excavation, earth work concrete pit with 50mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 6mm dia @ 150C/G both ways and pit chamber in PCC 1:2:4 TYPE B-1 with 2 No's suitable lifting handles of 12mm MS bar and GI protection pipe of 20mm dia and watering pipe 20 mm dia with washer funnel with wire mesh, test point and extra length up to 7.5 mtr (beyond 7.5 mtr will be measured seperately) connected to main switch board all as specified. Note : On testing after completion if desired earth resistance 1.5 Ohms is not obtained the earthing will be redone by the contractor without extra cost to Govt.
M&L earth continuity of main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required of size 20 x 3mm copper strip with fixed saddles complete all as specified and as directed.
M&L earth continuity of main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required of size 25 x 3mm aluminium strip with fixed saddles complete all as specified and as directed.
M&L test point terminal block made of gun metal or phosphoras of size 75 x 75 x 25mm drilled and screwed including 3 No's 08 mm dia, 25mm long hex heat screws including sheet metal box of suitable size complete all as specified and directed.
M&L for fixing the Air termination, single pointed aluminium rod 12mm dia and 300mm long including PCC foundation for mounting air terminal and GI pipe of suitable size 1.5 mtr complete all as specified and directed.
NITHYA INFRATECH (BID ID -3259573)
SIDDHARTH TRADERS (BID ID -3253840)
Narender Construction (BID ID -3258244)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .