Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC VILL BENIADANGA P O MALLICKPUR P S BARUIPUR KOLKATA 700 145 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700145 | ₹1.4 L | L1 | Accepted-AOC WORK ORDER ISSUED |
| 2 | L2₹1.4 LRejected-Finance VILL BENIADANGA PO MALLICKPUR PS BARUIPUR SOUTH 24 PGS KOLKATA 175 | 175 | ₹1.4 L | L2 | Rejected-Finance NOT L1 BIDDER |
| 3 | L3₹1.4 LRejected-Finance VILL BENIADANGA PO MALLICKPUR PS BARUIPUR SOUTH 24 PGS KOLKATA 175 | 175 | ₹1.4 L | L3 | Rejected-Finance NOT L1 BIDDER |
| 4 | Rejected-Technical 5A GOBINDA SARKAR LANE KOLKATA 700 012 | KOLKATA | WEST BENGAL | 700012 | - | - | Rejected-Technical Rejected |
| 5 | Rejected-Technical N A | - | - | Rejected-Technical Rejected |
Tender Value
₹1.4 L
EMD Value
₹2,850
Closing Date
24 Mar 2026, 3:00 pmClosed
Assistant Engineer CKHSD-II PWD
Central Kolkata Health Sub Division II 138 AJC Bose Road NRS Medical College Building 1st Floor Kolkata 700 014
SHYAMADAS Repair and renovation work of Yoga Room located at Ground Floor during the year 2025 2026
2026_WBPWD_1013290_1
WBPWD/AE/CKHSDII/NIeT20/25-26
Open Tender
CIVIL WORKS
10 days
Shyamadas Vaidya Shastra Pith Hospital Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,850
Yes
13 May 2026
23 Feb 2026
27 Mar 2026
23 Feb 2026
24 Mar 2026
23 Feb 2026
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. In 10-12 Micron thickness Annodizing film- Natural white - Fixed partitions. (Unsupported length of vertical member more than 1.5 mtr.or both ends of vertical member restrained but panels more than 0.9 Sq.m) Top , bottom & side member :
Intermediate member :
Supplying fitting & fixing in position 9 mm thick Heavy Duty Cement board - Type- A (High Pressure steam cured, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, density > 1450kg/m3, Bond strength 15 N/sqmm fire resistant, termite proof, moisture resistant) reinforced with cellulose fibre manufactured through autoclaving process as per IS : 14862 & ISO 8336, with fibre cement screws in partition excluding cost of supporting structure as per drawings and direction of Engineer-in-Charge complete. (Note: The Item -26 under Section - U (Page - 247) can be used as supporting structure for internal partition ).
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame etc.. Partly glazed and partly panelled partition or fixed glazing made of extruded and anodised alloy aluminium sections, fabrications after cutting to proper shape and size, drilling and aligning fitted with inbuilt locking arrangement cutting the glass / board (prelaminated / particle / block) to requisite shape and size moulding the edges fitted and fixed glazing clips and dry set neoprine /EPDM gasket, along with all other necessary arrangements for fixing the partition to walls, floors, beams, columns polysulphide sealant for water proofing if necessary complete in all respect as per drawing and specifications and direction of the Engineer in charge. 101.50mm x 44.45 mm :
Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 4 mm thick High Pressure Steam Cured Non Asbestos pearl designer Fibre Cement Standard Ceiling Board (Density > 1500 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type A Category IV of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor.
Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating) :
Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) One Coat -- Solvent based interior grade Acrylic Primer.
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) Luxury Quality :
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary On timber or plastered surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
Please Enable Macros to View BoQ information
stage.html
html • 0.10 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.34 MB
BOQ_2488938.xls
BOQ • 0.28 MB
2911_FINAL.pdf
Tender Documents • 1.86 MB
Download all tender documents and submit your bid