Loading…
Loading…
Tender Value
₹18.6 L
EMD Value
₹37,100
Closing Date
10 Jul 2026, 3:00 pm
Similar tender results from the same govt authority in the past 3 years.
Electrification work in connection with Provision of Running Room (18 rooms, 36 Beds) at BKI station.
ELG-04-J06-2026-27
ELG-04-J06-2026-27
Open
8 Months
Unknown (Unspecified Location)
₹0
₹37,100
16 Jun 2026
16 Jun 2026
26 Jun 2026
1-Electrification work in connection with Provision of Running Room (18
Supply of material fixing and providing the Light/FTL/C.Fan/E.Fan concealed wiring point with 2.5 Sq.mm FRLSH/HFFR insulated and sheathed multistrand copper wire 1100 V grade, single core with 1.5sq.mm. PVC insulated copper conductor for continuous earthing in recessed 1 steel/PVC conduit pipe 25mm. 1.6mm.thick dia bend, junction box etc. with ceiling rose batten holder, flush type 5A. switches mounted on white laminated phenolic sheet 3mm. thick cover on front of MS box made of 18 S.W.G. MS sheet of suitable size complete with replastering of wall if required wiring to be done in separate circuit. (Concealed wiring to be done on walls and roof if RCC roof is already constructed surface through PVC casing caping good quality double lock type wiring may be done.)
Supply of material for fixing and providing 5 pin socket outlet point (3 pin + 2 pin) 5- A/230 V. with flush type 5 Amp. Socket combined type with switch in concealed wiring by 2.5 Sq. 2 mm. PVC insulated multistranded copper wire single core 1100 V. Gr. in recessed steel conduit pipe 25 mm. dia & 1.6mm. thickness with 5 Amp. /230 V. flush type switch fixed on white phenolic laminated sheet 3mm. thick cover on front of MS box of suitable size complete including 1.5 Sq. mm. FRLSH/HFFR insulted copper conductors for earthing and replastering of wall.
Supply of material for fixing and providing of concealed wiring point of 6 pin (3 pin 15 Amp. + 3 pin 5 Amp.) power socket flush type 15 A/5 A - 230 V. comprising of switch 15 Amp. & 3 recessed MS conduit wiring or in casing caping PVC double lock type of good quality with suitable wooden board well polished by 4 sq. mm. FRLSH/HFFR insulated multistrand copper cable 1100 V. grade single core including 1.5 sq. mm. FRLSH/HFFR insulated copper conductor for earth wire, mounted on white phenolic laminated sheet 3mm. thick cover on front of MS box 1.6mm thickness complete with replastering of wall. (Separate circuit to be drawn from SDB.)
Supply, erection, Testing & Commissioning of sub main consisting of 2x4 Sq. mm (P& N) PVC insulated and sheathed copper wire multristanded single core 1.1KV grade alongwith 1.5 Sq.mm PVC insulated copper wire 1.1 KV grade for earthing. (Quantity 1 Mtr.Equal to 02 Nos., wire of 4Sq.mm of 01 Mtr.each. and 01 No. earth wire 1.5 Sq.mm. of 01 M) (No cable joint is permitted inside the MS conduit pipe cable should be jointed with cable connectors inside the switch board)
Supply, Erection, Testing and commissioning of MS/PVC conduit pipe 25mm dia 5 and1.6mm thick, recessed in the wall and through the wall by making hole and replastering the same in original condition complete with Tee, elbow,junction box, sadle & Other accessories for sub main wiring.
supply, erection, Testing & Commissioning of energy efficient LED street light fitting 6 60 Watt outdoor complete street light fitting pressure die cast aluminum (PDC) body with make embossed on PDC body and complete with all accessories/ components and connection with PVC copper wire 2.5sq.mm size multicore and fixing arrangement as per site requirement. The technical parameters will generally conform to relevant Railway specification attached Annexure-II
Supply, fixing, testing & commissioning of MCB DB single phase with RCBO, m.s. enclosure, I/C -DP RCBO of 40Amp - 1No, O/G: SP MCB of 6A - 32A - 8Nos, as per specifications. 30 mA
Supply, Erection, Testing & Commissioning of Metal Body Heavy duty type exhaust 8 fan 300mm/380mm suitable to work on 230 volt AC supply connection shall be taken with twin cord flexible PVC insulated copper wire size 48/0.2mm. exhaust fan to be fixed on wall with MS reg. bolt nut washer etc
Supply, Erection, Testing &Commissioning of 5 star rated super energy saving efficient BLDC Ceiling Fan, sweep size1200mm., down rod length asper site requirement, power 9 factor greater than 0.98 with Electronic Regulator & double ball bearing and MS Flat size50 X 5mm clamp of suitable size with hanging hook, nut bolt washer etc & Connection shall be taken with twin cord flexible PVC insulated copper wire size 48/0.2 mm., 03blades of Aluminum with power consumption not more than 28 Watt, Warranty 03years, required. 5 star rated BLDC super energy efficient ceiling Fan with double ball bearing, power 28 W. cat-Fan super efficient-ceiling BLDC
Supply, Erection, Testing & Commissioning of luminaire complete with all accessories, 10 18/20 watt, 04 feet LED tube light fitting & Tube with suitable current control driver circuit, suitable for surface mounting and connection with PVC copper flexible wire of 23/76 as per Rly. specification attached.
Supply, Erection, Testing & Commissioning of material of concealed wiring point of 3 pin power socket 20 Amp./230 V in sheet steel enclosure with 20 Amp. Single pole MCB-SP, 3 pin 11 metal plug and wiring by 6 sq. mm. PVC insulated multistranded copper wire single core in recessed steel PVC conduit pipe 25 mm. 1.6mm. thick dia with 1.5 sq. mm. PVC insulated copper wire complete with band, MS Junction Box etc. complete with replastering of wall. (Separate circuit to be drawn from SDB.)
Supply, Erection, Testing & Commissioning of Insect killer 18 W 04nos. LED tube based.
Supply, Erection, Testing and commissioning of Single earth electrode of 50mm dia 3000mm long GI Pipe class B conforming to IS: 1239 latest complete with earth box including connection from earth electrode to MDB/SDB/poles/With 8 SWGGI Wire
Supply, Erection, Testing and Commissioning of energy efficient Rechargeable Turbo 14 Inverter LED Blub 12watt having back up time 4hrs., and normal and turbocharging mode, having min rated lithium battery capacity of 2600 mAh with rated voltage of 100-300 VAC make: Halonix, C&S, Philips.
Excavation of trench 300 mm wide at the bottom, 1.0 Mtr deep on 15 platforms/road/concrete surface etc. Refilling and restoring the platform surface to its original condition including necessary plastering work with contract or sown materials at his own cost. Work shall be carried out as per instruction of Railway Engineer in charge at site. In case depth of trench is less than 600 mm specific approval of Engineer in charge of Railways should be obtained.
Supply, Erection, Testing and commissioning of hot dip galvanized octagonal pole 5 16 Mtr. long confirming to IS 2629/BSEN ISO 1461 or equivalent including casting, muffing with cement concrete foundation (1:2:4) painting, earthing etc. the pole shall be complete with holes, Anchor bolts, bottom plate etc. As per Tech. Specification/site requirement, IS/IE rules of Double Arm type with 1.5 feet to 2 feet long type
Excavation of cable trench:-This item shall be operated in conformity with IS:1255(latest version) i.e. code of practice for installation and maintenance of HT/LT cables. The price shall cover cost of excavation of cable trench in all type of soil for laying LT cables and back filling the same with sieved earth and finishing the surface in its original condition after providing sand, & bricks in cross position. For LT/HT cables the trench shall be 600mm wide x 1000mmdeep. In 17 trench the cable shall be covered with rivers and at a depth of 100mm below the cable and 100mm above the cable than placing well-burned bricks continuously in cross position through out the cable route in the ground. The bottom of the trench should level free from stones and sharp edge of rocks etc. At the termination a loop of 5 meter(approx.) cable shall be kept as allowance and loops rings be formed as per the site condition, in the ground, The cost shall include the cost of all materials i.e. sand, bricks, cable route markers (grouted in the earth firmly with cement concrete so that it can not be uprooted by miscreants) etc at 25m.interval and each turn of the cable.
Laying/Cleating erection, Testing & Commissioning of HT/LT Cable 03/04 Core on wall with all accessories & refilling of cable trench (asper IE rule) after laying of cable (Cable will be supplied by Rly free of cost at Consignee Depot)
Horizontal boring of cable duct at 1.4 to 2.1 mtr. depth from the bottom of 19 sleeper/ground label and laying of120 mm Dia HDPE DWC pipes for cable crossing under track/ road .The work shall be done as per extant practice and instruction of site engineer. It includes supply of DWC/HDPE pipes conforming to IS14930(Part:2:2001)
Supply, Erection, Testing and commissioning of Self contained Drinking water cooler with (Non-CFC refrigerant) energy efficient compressor cooling cap Liters/Hrs storage type, Capacity 150 Ltrs, rate of max energy consumption 1550W
Supply, Erection, testing and commissioning of Heavy duty powder coated stand for outdoor unit of split type AC
Supply, Erection, Testing and commissioning of 25Ltr Electric storage water heater, minimum 4 star rating white HSN code 8516.
Supply, Erection, Testing and commissioning of Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base. 1 N x 9 W LED Lamp/ 1 N x 7.5 W LED filament lamp, Order code LHFOAJE1TZ1I060
Supply and fixing of 3W Modular LED Foot Lamp suitable use on 230 V, 50 Hz AC
Supply, Erection, Testing and commissioning of auto clean wall mounted chimney, T- Shaped with Aluminum Blower Body & Stainless steel Blower Blade, Push Type Control Panel.
Supply, Erection, Testing & Commissioning of wall mounted Sub Distribution Board (Light/power) TP&N Vertical Three Phase wall mounting type 4 way peari ivory dust and vermin proof 26 in door type factory fabricated from sheet steel enclosure (1.6 mm. thick ivory colour) 04 way fitted with double door copper bus bar, neutral link, earth terminal detachable glands fitted with following item. (SDB make as per attached approved list) 01 No. 125Amp. 50 KA MCB-TPN-on incoming side. 12 Nos 16 to 32Amp. MCB-SP- on out going side.
Supply, erection, testing and commissioning of 400AMCCB 2 nos. as incoming and 1no.Auto changeover switch and 6 nos. 125 A MCCB and 4nos.63 A MCCB, 04 nos.32 A DPMCB and 4nos. 16 A DP MCB as outgoing complete with busbars, neutral link, etc. The price shall cover the cost of supply ,loading, transportation, unloading to the site, erection, testing and commissioning of 3 phase outdoor (Canopy/Hut Type) & double door type LT distribution panel comprising 2 nos. 400Amps FP MCCB as incoming with 1 no. 400 Amps automatic transfer switch (with auto, manual and by pass arrangements) and 6nos.125 Amps FPMCCB, 4 nos.63Amps FP MCCB, 04nos. 32Amps DPMCB and 4 nos.16Amps DP MCB as outgoing with 4 nos. copper bus-bars of size 50 x 7 mm, RYB indicator, digital multifunctioning Energy meter (KWH, Volt, Amp),selector switches, indicator lamps (LED type) with cable alley chamber and other associated accessories complete with cable termination by cable gland, lug, nut bolt etc. All internal wiring in the panels shall be carried out using FRLSH wires. The MCCB shall be adjustable type having ground fault module with (Ics =100%Icu) and breaking capacity of MCCBs shall be 50 KA for 400A & 250 AMCCBs, 35 KA for125A & 63 A MCCB and 10 KA for MCB. The enclosure of LT panel shall be fabricated of12SWG CRCA sheet, weather proof powder coated type with other accessories. The panel board shall be wall mounted /CC flooring with MS stand made of MS angle of size 50 mm x 50mm x 6 mm and skeleton type angle structures with holes for cable entry & exit as per site condition. The angle structure of panel should be covered with M.S. Sheet and duly painted. The panel board shall be properly earthed as per IS. The successful tenderer shall be required to submit circuit diagram and block diagram for the panel board and start fabrication after approval of the same by Sr.DEE (G)'s office. The LT panel shall be designed manufactured and all type tested in accordance with the latest relevant IEC(viz. IEC 61439 1-6,60947-2, 60898-12002 or latest) standards. The contractor shall submit original test report from CPRI/ERDA / Any other equivalent Govt. Testing Agencies.
Wiring for circuit / submain wiring along with earth wire with the following sizes of 28 FRLS PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.14.5 Size : 2 x 10 sq. mm + 1 x 6 sq. mm earth wire
Supply, fixing, testing and commissioning of LED type reading light fitting complete with 2.5 watt LED lamp and its control switch of approved make and as per relevant technical specification. Inspection by- Consignee.
Supply ,installation, connections, testing and commissioning of 5 KVA UPS ,5 star, 30 sine wave, MOSFET-PWM, with VRLA battery conforming to JISC:8702 (Pt. I,II & III), Backup time(Minutes)- minimum 180 minutes or higher, input- single phase sine wave (120 to 260 V), out put single phase sine wave 230 V, total harmonic distortion -</=5% as per IE rule and as per site requirement. Make of UPS : Microtek, Sukam, Luminous or similar make
Supply, Erection, Testing and Commissioning of GI pipe 'B' class of minimum 50 mm. Dia, suitable for cable protection or underground rail/road crossing with fixing clamp at least 03 Nos. for one pipe of MS flat of 50 x 6 mm. size clamp duly Aluminum painted
Supply, Erection, Testing and commissioning of 40Watt LED 2 X 2 Colour Temperature(+/-500K)-6000 Deg K ceiling mounting type
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril202227-04-2022.pdf
ATTACHMENT
ACS-1.pdf
ATTACHMENT
Correction Slip 02
ATTACHMENT
Correction Slip 03
ATTACHMENT
Correction Slip 04
ATTACHMENT
Correction Slip 05
ATTACHMENT
Correction Slip 06
ATTACHMENT
Correction Slip 07
ATTACHMENT
Correction Slip 08
ATTACHMENT
Correction Slip 09
ATTACHMENT
Correction Slip 10
ATTACHMENT
correctionslipNo.-02GCC13-12-22.pdf
ATTACHMENT
CorrectionslipNo.-03ofGCC-2022.pdf
ATTACHMENT
GCCCorrection07-08-2023SlipNo.4.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_5ACS-5.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_6ACS-6.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_7ACS-7.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-8.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-9.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-10.pdf
ATTACHMENT
ACS-11.pdf
ATTACHMENT
Shramikkalyan.pdf
ATTACHMENT
Letterofcredit.pdf
ATTACHMENT
AnnexureVA1Policy.pdf
ATTACHMENT
AnnexureC.pdf
ATTACHMENT
TenderDocument.pdf
ATTACHMENT
Download all tender documents and submit your bid