Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹15.6 L
Closing Date
27 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer University of Kashmir
Construction Division
Electrification for Bio resources and Bioinformatics Department (Phase III at Zakura Campus.
2021_UDJK_153817_1
F(UCD)(Elect. B-Res. B-Inf. At ZC)/KU/74/21
Open Tender
Electrical Works
Item Rate
60 days
Zakura Campus
As per NIT
8 documents required · 8 mandatory
₹600
Registrar University of Kashmir
Exempted
28 Dec 2021
17 Dec 2021
28 Dec 2021
17 Dec 2021
27 Dec 2021
17 Dec 2021
120 days
Amount
Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC/ MS conduit , with modular switch modular plate , suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required..(Conduit shall be heavy duty) Note : Rates of Suitable PVC/ MS conduit included in above description for the above mentioned items. Applicable Test Certificates have to be submitted following BIS Standards and ISI Marks wherever necessary (DSR 1.10.1) From switch board to primary light point & it's loop.
Wiring for heating point with 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with 16A modular switch, 1 Nos. 16A modular socket, modular plate having relevant IS Mark , suitable GI box and earthing the point with 4 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required..(Conduit shall be heavy duty/ISI Marked) Note : Rates of Suitable PVC conduit included in above description. Applicable Test Certificates have to be submitted following BIS Standards and ISI Marks wherever necessary
Wiring for Industrial type socket outlet point with 2 X 6 sq. mm + 1 X 6 sq. mm earth wire FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with 30 A, 415 V, TPN Industrial type socket outlet (Conduit shall be heavy duty), metal enclosed plug top alongwith 30 A "C" curve, TPN MCB, in sheet steel enclosure, on surface or in recess Note : Rates of Suitable PVC conduit included in above description & point taken upto DB duly tested and commissioned
Supplying and fixing of 25mm sizes of medium class MS conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit(heavy, ISI Mark) as required.
Supplying and fixing of 25mm sizes of heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit(heavy, ISI Mark) as required.
Supply and fixing of ISI marked aluminum conductor XLPE insulated cableas per IS 7098, armoured, served, sheathed 1100 volts grade.
4x 70 sq. mm
4x 16 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm (22mm)
4 X 70 sq. mm (32mm)
Supplying and fixing prewired prefab TP&N MCB distribution board of sheet steel for 415 volts on surface/recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly wired with suitable size FRLS PVC insulated aluminium conductor upto terminal blocks, tinned 200A copper bus bar,neutral link, earth bar, din bar, detachable gland plate, interconnections, powder paint including earthing with following MCBS(ISI mark, IS 8828-1996, IEC 898), MCCBS (ISI mark, IS 8828-1996, IEC 898)(wall mounted, 3mm thick): 6A SP MCBs= 12Nos. 40A TPN MCBs=7Nos. 32A DP MCBs= 2No. 125A,36kA TPN MCCB=1No. i/c 2 nos. Digital type multifunction meter
Main LT Panel: Supplying and fixing prewired prefab TP&N MCB distribution board of sheet steel for 415 volts on surface/recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly wired with suitable size FRLS PVC insulated aluminium conductor upto terminal bloacks, tinned 400A and 80A aluminium bus bar,neutral link, earth bar, din bar, detachable gland plate, interconnections, powder paint including earthing with following MCBS(ISI mark, IS 8828-1996, IEC 898), MCCBS (ISI mark, IS 8828-1996, IEC 898)(wall mounted): 250A,36kA TPN MCCB=1No. 1No. Manual changeover of 125A 6 Amp to 32 Amp. S/P MCB=10Nos. 32A DP MCB= 1Nos. Digital multifunctional meter having RS 485 port for BMS Integration with 1 set of CT's of 60/5 Amp & 1 set of CT's of 200/5 Amp. 1 set of CT's of 250/5 Amp for in main breaker of Main LT Panel. 2 Set of R,Y,B LED phase indicating lamp with MCB protection. 2 Set of ON,OFF & TRIP LED indicating lamp with MCB protection.
Supplying in underground/clamped to wall with suitable clamps saddles and fixing bolts/ in ground including testing and commissioning of the following sizes of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable conforming to IS : 7098 (Part-I). Identification tags shall be provided for all cables and route markers for cables in ground as per specifications and as per instructions of Engineer- in-charge. 4 core X 150 mm2 Armoured XLPE Aluminum cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, and refilling the trench etc as required-Above 150 sq. mm and upto 300 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required-4 X 150 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required 120 mm dia (OD-120 mm & ID-103 mm nominal)
Supply and fixing of 40 W or more Suspended LED Light approx. 4ft length i/c joining kit and Mains cable, chain etc. LxWxH = (1200x104x61)mm complete Certification: LM79-08, LM80, L70, NABL etc. certificates have to be submitted
Providing/ fixing of 4 ft long LED type tube lights, 20Watts to 22Watts, 230V complete with tube, base etc. (wall mounted) Certification: LM79-08, LM80, L70, NABL etc. certificates have to be submitted
Providing and Fixing of 7 Watts LED Panel, round/square type, color temp: 6500K/4000K, Surface/Recessed mounted as per site requirement Certification: LM79-08, LM80, L70, NABL etc. certificates have to be submitted
Supplying, erection and testing of approved make electric ceiling fan of complete with down rods of required length as per site, canopy, hanging shackle, Aluminium blades, A.C. 230-250 volts including connections / wiring the downrods with all necessary material complete of approved as required -Ceiling Fan ( ISI )-1400 mm Sweep,4 Blades, 80-90W. including required length of extra down rods
SITC of approved make Exhaust Fan of 380 mm (15 Inches), heavy duty metal body with mounting frame, blades AC 230-250 complete connection and including, frame bolt/ Anchor hole fastners etc. complete finished of approved as required
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but including modular plate etc. as required complete in all respects.(for ceiling fans points)
Supplying and fixing 6 A ceiling rose having ISI Mark i/c junction box including connections etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. i/c Constructing masonry Chamber 100x100x100 cm, inside with 75 class designation brick work in cement moryar 1:5 ( 1 cement : 5 fine sand ) for valve, with C.I.surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12mm thick finished with a floating coat of neat cement complete as per standard design (NOTE: Actual Depth of chamber may vary as per Site conditions).
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing of outdoor type MS Steel cubical panel having minimum thickness of 2mm, double doors, dust and vermin proof in cement foundation of M20 of required size. Two coats of epoxy based primer shall be applied before applying two final coats of epoxy paint. Electrostatic epoxy powder coating shall be applied after pre-treatment in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate foundation including excavation and refilling.The colour of paint shall be RAL 2009 including providing and fixing of following equipments a) 250A TPN MCCB (ISI mark, IS 8828-1996, IEC 898) b) 1 Set of R,Y,B LED phase indicating lamp with MCB protection. c) 400 Amp aluminium busbar chamber of suitable length with aluminium busbars. All busbars and interconnections shall be of suitable size aluminium strips. Current density of aluminium shall not be more than 0.8 Amps/ sq.mm. d) 1 Set of Amp meter, Volt Meter & Frequency Meter with 1 set of CT's of 60/5 Amp for outgoing feeder as marked in SLD.
M/s J. K. Electrical Works
HUBBI ELECTRICALS
M/S BRIGHT SPARKS
M/S B.I.ELECTRICALS
stage.html
html • 0.02 MB
finance_341769.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .