Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 CrAccepted-AOC | ₹18.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹19.4 CrRejected-Finance | ₹19.4 Cr | L2 | Rejected-Finance L2 |
Tender Value
₹18.0 Cr
EMD Value
₹9.0 L
Closing Date
4 Mar 2024, 6:55 pmClosed
EXECUTIVE ENGINEER INTEGRATED UNIT (M)P.W.NAGPUR
OFFICE OF THE EXECUTIVE ENGINEER INTEGRATED UNIT (M)P.W.NAGPUR, T.B. WARD PREMISES NAGPUR
CONSTRUCTION OF MULTILEVEL PARKING WITH CAR LIFT (G PLUS 3) INCLUDING ELECTRIFICATION AT INDIRA GANDHI GOVERNMENT MEDICAL COLLEGE AND HOSPITAL, NAGPUR
2024_PWR_1004973_1
pwc/ngp/IUM/44-11/2023-24
Open Tender
Civil Works - Buildings
540 days
NAGPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,540
via Net Banking
₹9.0 L
Office of the C.E. P.W.Region, Civil Lines Nagpur
30 Mar 2024
14 Feb 2024
6 Mar 2024
14 Feb 2024
4 Mar 2024
14 Feb 2024
20 Feb 2024
Amount
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means
Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (To be executed with prior approval of Superintending Engineer)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper.
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete.
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
UPTO PLITH FLOOR LEVEL
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
UPTO PLITH FLOOR LEVEL
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
THIRD FLOOR
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
BELOW PLINTH
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing Water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make (such as Master Seal 550/ brush bond / RoffSupercrete / Webercrete / Monobond /Perma shield / Hypercrate / Master Crete M 81) and Cement in 1 : 2 proportion ( 1 litre polymer : 2 Kg. Cement) to a neatly cleaned and dust free concrete surface and upto 300 mm. over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protective mechanical cover water proof plaster 20 mm thick after sufficient curing apply IPS 40 mm to 75 mm. thick cement concrete of 1:2:3 proportion using coarse aggregate of 10 MSA and water proofing compound of approved make and polypropylene fibres @ 125 gm per bag of cement making groovr 3 to 4 mm wide & 10 mm deep in concrete, in pannels of 3m/4m or as per site condition & filling the joints with poly sulphide sealant after curing including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry, as directed and ponding the surface as directed etc.complete ; covering 10 years guarantee against leakproofness on court Fee stamp paper of Rs 100/-
TERRACE FLOOR
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing flush grooved pointing with cement mortar 1:3 for brick work including scaffolding and curing etc. complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand)
GROUND FLOOR
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and fixing solid core flush door shutter in double leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and fixing of factory made Upvc Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2mm), duly reinforced with G.I. section 1.5mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BSEN 12608 and others tandard sas mentioned below :S.No. Name of the test Test Method Specified Parameter1Tensile Impact Strength ISO8256-more than 700Kj /m22 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM/ TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window/ Door will be fixed to the wall with 100mm long and 8mm dia. Fastener sand complete in all respectas per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten(10) years against non-uniform dis coloration.wrapping and rotting under general use.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing & fixing factory-made Single leaf 2 hour fire rated door as per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL /CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of 1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of 5mm thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer , Panic bar and external trim lock and Flush bolts complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt.
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. Spec.No.: As directed by Engineer- in-charge .
Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kilogram/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and laying in trenches 50 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 5.17 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete.
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Concrete Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
TERRACE FLOOR
Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 Kilogram/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300 in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring.
Dismantling flat wooden or A.C. Sheet ceiling with frame work including stacking the materials as directed with all leads, lifts etc. complete.
Removing iron pipe raling having wooden R.C.C. or C.C. or iron post and stacking the materials as directed etc. complete.
Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete.
Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc.
Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete.
Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete.
Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete.
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete
Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete.
Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. Spec.No.: As directed by Engineer- in-charge .
Drilling of Borewell by reverse rotary method in all types of Trata 400 including all charges ete c complete
Providing and fixing 150 mm dia MS csing pipe class B 4.80mm thick as per IS 1239(Blank)
Yiest test by Air lift Method with 90Cone "V: notch as directed
Loweing 150 mm diametre MS steel pipe ERW medium class casing (4.8 mm thick) loweing grouting etc complete
Providing and fixing MS steel cap 150 mm dia meter
Cement (Physical Tests) Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness.
Cement Concrete Concrete Mix Design (With all Tests on basic materials)
Cement Concrete Compressive Strength OF C.C. Cube (Set of 3 cubes).
Steel Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.Upto 16 mm (Set of 3 Bars) Upto 16 mm
Steel Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.Upto 16 mm (Set of 3 Bars) Above 16 mm (Set of 3 Bars)
Fine Aggregate Fineness Modulus ( Sieve Analysis ),Silt & Clay Content
Fine AggregateChloride & Sulphate Content.
Silt Factor.
Coarse Aggregate Water Absorption, Specific Gravity,Impact Value, Crushing Value.
Coarse Aggregate Sieve Analysis.
Coarse Aggregate Abrasion Value.
Coarse Aggregate Flakiness Index & Elongation Index.
Coarse Aggregate Soundness.
HB METAL-Crushing Value/Compressive Strength, Water Absorption & Specific Gravity,
MURUM Liquid limit & plastic Limit.
BRICKS Compressive Strength
Tiles Flooring of Natural Stone (Kota,Marble, Granite,Tandur.etc.) Water absorption, Specific gravity
Carrying out testing BASIC TEST OF FLOORING TILES (MOSSAIC / CEMENT) Flexural test ( Set of 6 Tiles), Water Absorption ( Set of 6 Tiles). Resistance to wear (Set of 6 Tiles).
WaterPH Value, Sulphate & Chloride Content
Royalty charges for Sand
Royalty charges for Murum+HB Metal
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
SSupplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking /inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW (LDB Circuit)
Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW (LDB Circuit earth)
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background
1-w- Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW
2-w- Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
Wiring for plug on board with Switch socket surface/ concealed type, copper wiring and earthing and with modular accessories as per specification No: WP W/CW
Supplying and erecting CRCA powder coated corridor / passage light LED fitting (4 feet) Max. 33W with high transitivity diffuser with system lumens output of Min. 4000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying, erecting, testing and commissioning of 2kVA capacity online pure sine wave, with backup time of 30 MIN PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS (for Camera NVR, LAN Rack & EPABX supply)
Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL( PANEL TO POWER DB)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (MAIN PANEL TO LIGHTING PANEL)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ( MAIN SUPPLY CABLE & MAIN PANEL TO POWER PANEL)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(DB TO EV CHARGER)
Supplying, erecting, testing and commissioning of 10kW, 3 x 3.3 KW AC Electric Vehicle charger (suitable for 2/3/4 wheeler) having minimum IK08/IP 54 Protection suitable for three phase, 415V AC, 50Hz incoming and 3 nos. output as per IEC 60309 industrial sockets having capacity of output current of 16A 240V AC at each socket with 3.5"TFT touch screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, one hour battery backup for communication, emergency push stop button and having short circuit, over & under voltage, overload, over temperature, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 Coated M.S, Erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification.
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW SWR/MCBDB1
Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/ RCBO
Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/ MCCB (18563)
Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/ MCCB (18563)
Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400A, 4 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs)
Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400A, 12 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW SWR/MCCBPB. (Excluding MCCBs)
Supplying and erecting terminal spreaders suitable for 4 pole, up to 100A MCCB (Set of 8)
Supplying and erecting terminal spreaders suitable for 4 pole, above 400A up to 630A MCCB (Set of 8)
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB.
Supplying & erecting four pole ON LOAD change over switch, 415V, 315- 320A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgradewith fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 6 way outgoing or 400A incoming and 4 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 12 way outgoing or 400A incoming and 6/8 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 400A incoming and 12 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit /trunking /inside pole/Bus bars or any other places as per specification No: WG-MA/BW (for 1 Lift- Lift Room- 7 mtr)
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking /inside pole/Bus bars or any other places as per specification No: WG-MA/BW (for 1 Lift- Lift Room- 7 mtr)
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (for 1 Lift- shaft- 25 mtr)
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (for 1 Lift- shaft- 25 mtr)
Supplying and laying rigid steel conduit 16 SWG 25 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No: WG?MA/CC (30 mtr for 1 Lift)
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. (shaft-2 (bulkhead-1 & socket-1)x 3= 6 x 1=6)
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. (shaft - 1 x 6 = 6)
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. (Lift Room- 1 x 1= 1 x 2 = 2)
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. (Lift Room power- 1 x 1= 1 x 2 = 2)
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. (Lift Room power- 1 x 1 = 1 x 2 =2)
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected (shaft- 1 x 3 = 3 x 2=6)
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG?PW/CW (Lift room-3 no x 2 = 6)
Wiring for plug on board with Switch socket surface/ concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW /CW (Lift Room- 1 x 1= 1)
Supplying & erecting 18W, 230V integral type LED Lamp suitable for B-22 /
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. (Shaft 3 x 4= 12)
Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base. (for Bulkhead)
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB (Lifr Romm power-1)
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB (shaft Lighting-1, Romm SB-1)
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB (Lift Room 4-SPN enclosure)
Supplying & erecting CRCA sheet metal one way enclosures suitable for DP MCB /TP MCB /FP MCB erected on angle iron/GI frame complete. (4P RCCB-1, 2P RCCB+2SP MCB-1) (2 x 3= 6)
Providing, erecting & commissioning 4 pole RCCB 100A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivity complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall /cable /conduit with screws complete. (8 SWG Tar- 0.116 kg / mtr - 24 Mtr x 0.116 Kg/Mtr = 2.78 Kg x 1 Lifts)
SITC of Electric Traction Passenger LIFT Rated capacity :- 15 Passenger/1020Kg……………. For Detailed wording of Item refer tender Book lete anad Speciification
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete.
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete.
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 82.5 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 14.0 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 145 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 62.5 kVA up to 82.5 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. . .....(10% less)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. (25x3 GI Strip - 30 Mtr x 0.59 Kg/Mtr = 17.7)
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and fixing POE adaptor to provide DC supply to ethernet devices as per specification No. WG-NAS/PEA
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying and erecting 25m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
Supplying erecting testing and commissioning of 2 MP motirised , verifocal, IP Dome Camera with built in microphone with having following features: (1) maximum 2M (1920 x 1080 ) resolution, (2) Min. Illumination : Color 0.095 LUX (30 IRE) , B/W : 0 Lus (IR LED On), (3) 2.8 - 12mm (4.3x) varifocal lens, (4) Field of view : H : 103.80 - 32.40/ / V: 53.70 - 18.40/ D : 121.90- 37.10 (5) 120 dB WDR (6) Max. 30 fps @ 2 M all resolusions (H.265/ H.264), (7) H.165, H.264 codec supported, (8) Intelligent analytic like Motion detection with metadata, tampering, defocus detection, (9) 128 GB micro SD/ SDHC/ SDXC memory slot, PoE/ 12V DC, (10) IR viewable length 20m. (11) Motion detection min 4 zones. (12) Multiple streaming upto 3 profiles, (13) Model specific UL,CE & FCC certification. Detection min 4 zones (14) multiple streaming min upto 3 profile (15 LDC support (16) Model specification and UL , CE & FCC certificationI) I) Video Resolution; Sub Stream 2MP (1920+1080) max; 30fps, Third Stream: D1 (720x576) max;30fps 2)Frame Rate;- Main stream 4MP (2592x1520), 20fps, 4MP (2560x1440) ; max; 25fps, 3MP (2048x1520); max 30fps sub stream 2MP (1920x1080) (Reference taken from- Estimet No-1356/BND/2021-22, TS Dt-25th Jan 2022 Sanction No. 196)
Supplying erecting testing and commissioning of 2 MP motirised , verifocal, IP Bullet Camera with external microphone with having following features: (1) maximum 2M (1920x1080) resolution, (2) Min. Illumination: Color 0.095 LUX(30IRE), B/W: 0 Lus (IR LED On), (3)2.8- 12mm(4.3x) varifocal lens, (4) Field of view: H: 103.80- 32.40/ V: 53.70- 18.40/D : 121.90- 37.10 (5) 120dB WDR (6) Max. 30 fps @ 2 M all resolusions (H.265/ H.264), (7) H.165, H.264 codec supported, (8) Intelligent analytic like Motion detection with metadata, tampering, defocus detection, (9) 128 GB micro SD/ SDHC/ SDXC memory slot, PoE/ 12V DC, (10) IR viewable length 30m. IP-66, IK10 (11) Motion detection min 4 zones. (12) Multiple streaming upto 3 profiles, (13) Hallway, view support, (14) LDC Support (15) Model specific UL, CE & FCC Certification I) Video Resolution; Sub Stream 2MP (1920+1080) max; 30fps, Third Stream: D1 (720x576) max;30fps 2) Frame Rate;- Main stream 4MP (2592x1520), 20fps, 4MP (2560x1440) ; max; 25fps, 3MP (2048x1520); max 30fps sub stream 2MP (1920x1080) (-Reference taken from 100 Beded Akot Hospital (NHM), Akot, Sanction date-6-12-22, TS No- 672 (Letter No 2385)
Supplying erecting testing and commissioning of 32 channel network video recorder (NVR) with 8. HHD slots for 48 Tb storage support having following specification : Dual core embeded processor with 8 HHD slots supporting 48 TB for internal recording and external ISCSI storage upto 384 TB, Embedded Linux, 32 Channel with 1080p Realtime Live View upto 12 Mega pixel resolution preview & playback ,256 Mbps Recording Bandwidth & 32 Mbps playback bandwith atleast playback of 16 channels simultaneously, Supporting TCP/IP,UDP/IP, RTP(UDP), RTP (TCP), RTSP, NTP, HTTP, DHCP (Server,Client), PPPoE, SMTP, ICMP, IGMP, ARP, DNS, DDNS, uPnP, HTTPS, SNMP, ONVIF (Profiles), SUNAPI (Server, Client) Protocals. (-Reference taken from 100 Beded Akot Hospital (NHM), Akot, Sanction date-6-12-22, TS No- 672 (Letter No 2385)
Supplying erecting testing and commissioning of 8TB cpacity internal SATA HDD having following specification General 7200.14, Capacity 8TB, Form factor 3.5'', interface option SATA 6Gb/s, Performance , Transfer rate Max Ext (MB/s)600, Sustained data rate OD210MB/s, Average latency (ms) 4.16, Power management , Idiling Typicaloperating (W) 7.5, Similar to Seagate make SATA 8TB (ST4000DM000)with 2yrs manu warrenty. -Reference taken from 100 Beded Akot Hospital (NHM), Akot, Sanction date-6-12-22, TS No- 672 (Letter No 2385)
Supplying erecting testing and commissioning 108 cm (43") Full HD slim LED television having Display 1920x1080 resolution similar to 2 x HDMI, 2 x USB Port 1 Year Samsung India Warranty 95 W Power Consumption Similar to Samsung Joy Plus UA43J5100AR43. (-Reference taken from 100 Beded Akot Hospital (NHM), Akot, Sanction date-6-12-22, TS No- 672 (Letter No 2385)
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and erecting minimum Three & above star rated submersible pump set of 3.75KW/5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 120 to 390 LPM discharge at 88 to 26 m head & discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP (1 running & 1 standby)
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete.
Supplying and erecting 50 mm dia. gun metal foot valve at position with necessary materials complete.
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.
Supplying and erecting CI flange 50 mm. dia with necessary nuts bolts and washers with rubber seal in position complete.
Supplying & erecting four pole ON LOAD change over switch, 415V, 40A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. (for openwll pump, incase felure)
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC
Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1600 to 1800 LPM at 70 to 55 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 30kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 1600 to 1800 LPM at 70 to 50 m head driven by 45 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine, exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears: 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. for detailed wording of Item refer tender Book let
For main electric motor driven fire hydrant system pump of 30kW capacity & relevant capacity jockey pump add Rs….
for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs…....
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting ISI mark GI pipe 32 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting ISI mark GI pipe 40 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 20 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting 19 mm dia high pressure rubber hose pipe complete as per specification no. FF-FFA/RHP
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ
Supplying and erecting 19 mm dia gun metal chrome plated nozzle complete as per specification no. FF-FFA/NZ
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and erecting brass orifice plate having 6 mm. thickness, 160 mm outer dia with required diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (Street Light Pole)
Supplying & erecting 415V, 16A porcelain base neutral link complete erected in provided M.S. box.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
D. V. Patel and Company
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid