Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.5 LAccepted-AOC | ₹49.5 L Quoted ₹49.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹54.5 L+₹4.6 L (9.24%)Rejected-Finance | ₹54.5 L+₹4.6 L (9.24%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹54.7 L+₹4.8 L (9.65%)Rejected-Finance | ₹54.7 L+₹4.8 L (9.65%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹55.3 L+₹5.4 L (10.9%)Rejected-Finance | ₹55.3 L+₹5.4 L (10.9%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹56.0 L+₹6.1 L (12.2%)Rejected-Finance | ₹56.0 L+₹6.1 L (12.2%) | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
5 Dec 2024, 6:00 pmClosed
GE (AF) JORHAT
JORHAT
REPAIR/RENEWAL OF FLAMEPROOF INTERNAL ELECTRIFICATION, FLAMEPROOF SUB MAIN WIRING, FLAMEPROOF AND REPAIR/MAINTENANCE OF CEILING/EXHAUST FAN/WALL MOUNTED FAN AND ALLIED WORKS AT VARIOUS LOCATIONS AT AFS UNDER GE (AF) JORHAT
2024_MES_683816_1
8663/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) JORHAT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹94,000
Yes
10 Jan 2025
14 Nov 2024
7 Dec 2024
14 Nov 2024
5 Dec 2024
29 Nov 2024
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) including complete fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. and removing materials to store for keeping in safe custody for re-use at site and making good to disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M&L for flame proof point wiring complete with 2.5 sq.mm single core PVC insulated unsheathed FRLSH cable of 1100 volts grade, ISI marked with multi stranded copper conductor, concealed type, drawn through and including stove enamelled steel conduit, heavy duty and conduit accessories, ISI marked, fixed on wall, roof, ceiling, etc. and including provision of 2.5 sq.mm PVC insulated multistranded unsheathed copper conductor cable FRLSH, ISI marked as earth continuity conductor, fabricated sunken terminal box, made out of 1.22mm thick sheet steel duly painted and fixed on walls with 3mm thick bakelite, ISI marked top cover with brass/ chromium plated screws and cup washers for housing switches, socket outlets, fan, regulators, etc. complete all as specified and as directed of the followings :-
One light point controlled by one switch
One 3 pin socket outlet 15 amps, on independent board with cables 4 sq. mm size
S&F as in repairs FLP WP rotary switch flame proof rotary type with termination box in LM6, 16A, single pole, 250 volt complete all as specified and as directed.
S&F as in repairs flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250 volt, 2P+earth complete all as specified and as directed.
S&F as in repairs LED light fitting 1x20 watt, flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including nuts, bolts, etc. as required complete all as specified and as directed. Make : Crompton, Cat No. EXTN1LT8-16/20 or equivalent model in make specified in Particular Specificatins.
S&F as in repairs LED light fitting 60 watt, flame proof well glass in die cast Al housing with heat resistant toughened glass, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including nuts, bolts, etc. as required complete all as specified and as directed. Make : Crompton Greaves, Cat No. FWL1315-60-CDL or equivalent model in make specified in Particular Specificatins.
S&F as in repairs LED light fitting 40/45 watt, flame proof well glass in die cast Al housing with heat resistant toughened glass, CMRI certified recommended for gas / vapor group of IIA & IIIB Zone 1 & 2 and IP 65 protection complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including nuts, bolts, etc. as required complete all as specified and as directed. Make : Crompton Greaves, Cat No. FWL1315-40-CDL or equivalent model in make specified in Particular Specificatins.
S&F as in repairs for 120 watt LED flood light fitting, LED flood light luminaire with high pressure die cast housing acting as heat sink in order to ensure better performance of the luminaires, complete including clamp, nut, bolts, etc. and other accessories for fixing including cable for connection after and including taking down old unserviceable light fittings complete all as specified and as directed.
S&F as in repairs 20 watt glass tube rod 4 feet, suitable for fixing in flame proof fittings complete all as specified and as directed.
S&F flame proof wearther proof DB SPN 240 volt, 8 way with busbar in cast aluminium LM-6 enclosure operated externally spring type knob complete with M-25 cable entry to suit incomming cable and 2 Nos M-20 cable entries for outgoing cable from bottom with cable glands suitable for hazardous area and confirming to IS- 2147/62 neoprene gasket degree of protection IP 65 including flame proof incomming 2 pole MCB 32 Amps (01 No) and outgoing MCB 6-32 Amp (06 Nos) complete including PCC as per manufacture's instructions and taking down the old unsericeable DB and making good the disturbed surfaces complete all as specified and as directed.
Supply and draw submain wiring with two single core 2.5 sq.mm FRLSH PVC insulated copper cable 1100 vots grade, multistrand, unseathed conductor, concealed type drawn into steel conduit and all necessary fittings including 2.5 sq.mm multi strand FRLSH PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete including taking down old unserviceable sub main wiring of any size and making good to disturbed surfaces complete all as specified and as directed.
All as per Serial item No.11 here-in-before but of two single core 4 Sq.mm for phase & neutral and one single core 4 Sq.mm for earth wire.
S&F as in repairs for building security light 35 watt LED light fitting, new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP-65 roadway luminaire with high power LEDs as light source and exclusively designed polycarbonate cover alongwith electronic driver complete after and including taking down old unserviceable light fitting complete all as specified and as directed.
S&F as in repairs 20 watt intregated LED tube light fitting, 4 feet, suitable for single phase 230 volts, 50 Hz, AC supply and mounted on wall or ceiling, complete with all accessories internally prewired and including electrically connection with copper conductor cable of size 0.5 Sq.mm (nominal area) complete all as specified and as directed.
S&F as in repairs 120 watt highbay light luminaire with high pressure die cast housing acting as heat sink in order to ensure better performance of the luminaires after and including taking down old unserviceable light fittings complete all as specified and as directed.
All as per Serial item No.15 here-in-before but of 100 Watt.
M&L for point wiring with 1.5 sq.mm FR grade PVC insulated and unsheathed stranded copper conductor cable, 1100 volts grade as per IS-694 drawn through and including PVC casing and capping (not less than 20mm wide) complete with all fittings and acessories including PVC board for mounting of switches, sockets, regulators, etc. and 1.5 sq.mm stranded copper conductor cable FR grade PVC insulated and unsheathed for earth continuity for one light point controlled by one, one way switch complete all as specified and as directed.
All as per Serial item No. 17 here-in-before but for one ceiling/Exhaust fan point controlled by one, one way switch.
All as per Serial item No. 17 here-in-before but for 5 amps socket point on independent board.
All as per Serial item No. 17 here-in-before but for 5 amps socket point on same board controlled by another switch.
All as per Serial item No. 17 here-in-before but with 2.5 sq.mm cable for 15 Amps socket outlet on independent board with 2.5 Sq.mm earth continuty wire.
All as per Serial item No. 17 here-in-before but with 4 sq.mm cable for 20/25 amps Power Unit on independent board with 4 Sq.mm earth continuty wire
All as per Serial item No. 17 here-in-before but for One bell point controlled by one bell push.
S&F ceiling rose surface backelite, three terminals, PVC/polycarbonate, insulated body complete all as specified and as directed.
S&F switch piano, flush type, 6 Amps 240 volts single pole, one way complete all as specified and as directed.
S&F socket outlet, 5 pin 6 amps, flush type complete all as specified and as directed.
S&F socket outlet, 15/16 Amps, 6 in 1, flush type complete all as specified and as directed.
S&F switch piano, flush type, 15/16 Amps 240 volts single pole, one way complete all as specified and as directed.
S&F fan regulator, electronic type, rotary step, socket type 240 volt complete all as specified and as directed.
S&F as in repairs switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal with box complete all as specified and as directed.
S&F as in repairs switch socket combination 2 in 1, 5 Amps, flush type with box complete all as specified and as directed.
S&F as in repairs MCB protected POWER UNIT with one 20 amps socket, (including 3 pin plug top) including MCB SP 20 amps suitable for flush mounting and surface mounting for protection of appliances like AC / Geyser, with neutral links, flush metal GI box and electrically connecting up after and including taking down old unserviceable wiring complete all as specified and as directed.
S&F as in repairs VTPN DB , 415 volt, 4 way, 100 amp bus bar with metal door having facility for MCCB incomming up to 250 amps and MCB out going including taking down old unserviceable DB complete all as specified and as directed.
S&F as in repairs SP&N DBs, double door, 240 volt, 4 way including taking down old unserviceable DB complete all as specified and as directed.
S&F as in repairs SP&N DBs, double door, 240 volt, 8 way including taking down old unserviceable DB complete all as specified and as directed.
S&F as in repairs MCCB 160 amps current carrying capacity 415 volts, 25 KA, 4 pole thermal magnetic type along with spreader terminals complete all as specified and as directed.
S&F as in repairs for MCB single pole, 240 volts, 6-32 amps, 10 KA, 'C' curve complete all as specified and as directed.
S&F as in repairs for MCB single pole & neutral, 240 volts, 32 amps, 'C' curve complete all as specified and as directed.
S&F LED luminaire of size 600mmx600mm, 35/36 watt, 220 volt AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Taking down/out unserviceable or serviceable UG cables of any cross sectional area and connections including bricks, GI pipes, etc. of any descriptions, laid in trenches and/or fixing with walls/poles including segregating of serviceable materials such as bricks, cables, GI pipes, etc. and keep in safe custody for re-use complete all as specified and as directed. Note: Necessary excavation and earth work shall be measured and paid for separately.
Excavating in trenches not exc. 1.50m wide and not exc. 1.50m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil complete all as specified and as directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.50m above the starting point in soft/loose soil complete all as specified and as directed.
M&L for cable in trenches/passing through pipe/on wall, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade of cross sectional area 16 sq.mm, 4 core complete all as specified and directed. Note: Rate of the saddle and clamp for fixing of cable on wall is included in this rate.
All as per Item Serial item No. 34 here-in-before but of size 10 Sq.mm, 4 core
All as per Serial item No. 34 here-in-before but of size 25 Sqmm, 3.5 core
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. Note : For the purpose of payment, punned thickness of sand cushioning only shall be measured and paid for.
S&F sub-class 'B' bricks, well burnt, laid breadth-wise along the length of cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and as directed.
Labour only for laying old serviceable bricks perpendicular to UG cable over the dry sand cushioning for cable protection complete all as specified and as directed. Note : old serviceable brickes obtained from taking down shall re-used.
Taking down/out unserviceable GI / HDPE pipes of any descriptions, laid in trenches and/or fixing with walls, poles, etc. complete all as specified and as directed.
S&F 50mm dia high density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm² fixed complete to walls. ceilings or in floors, etc. complete all as specified and as directed.
S&F GI pipe of size 50mm bore (dia) 'light grade' for protection of UG cable laid in floors/road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc. complete all as specified and as directed
Labour only for horizontal boring for passing protection pipe up to 80mm bore (dia), under road /footpath not exc. 10.00m in a single length complete all as specified and as directed. Note: Pipe shall be measured and paid separately.
Taking down ceiling fan/exhaust fan/wall fan of any sweep and make including cable end by disconnecting electric connection, dismantling blades, down rod and removing fan to MES Store Yard of AGE E/M (AF) Jorhat for checking complete all as specified and as directed.
S&F of ceiling fans complete with blades, down rods, electronic regulator, 2 Nos canopies, shackels and accessories including nut, bolts, washers, etc. 230 volt, 50 Hz, power input 52Watt, 350 RPM, 100% copper winding, 3 blades with upto 210mm long down rod, 1200mm sweep, min air delivery 215 CM with service value of BEE one star rated ISI marked with 2 years warranty including all connection required to connect a fan complete all as specified and as directed.
S&F in replacement 1200mm BLDC 5 star rated ceiling fan with regulator enable motor with power input of 28 watt with 10% tolerance, motor insulation B, 230 volt, 50 Hz, single phase AC speed 350, Air delivery 215 CMM with complete set of 3 Nos blades, down rod, 2 Nos canopies, shackel kit and all remaining accessories including nut, bolts, washers, etc. including all connection required to connect a fan complete all as specified and as directed.
M&L for opening stator of ceiling fan/exhaust fan/wall fan of 1200/1400mm sweep cleaning of parts, replacement of unserviceable parts as ordered greasing of moveable parts complete all as specified and as directed. Note : Unserviceable parts such as ball bearing, bush, capacitor, canopy, rubber reel, split pin, etc. shall be measured and paid separately.
Re-assemble only ceiling fan/exhaust fan/wall fan/pedestal fan of any sweep after repairing and testing complete all as specified and as directed. Note : Old serviceable fans obtained from taking down shall be re-assebled.
Supply only ball bearing No. 6201 as approved suitable for ceiling fan of any sweep and make complete all as specified and as directed.
Supply only ball bearing No. 6202 as approved suitable for ceiling fan of any sweep and make complete all as specified and as directed.
Supply only ball bearing as ordered suitable for exhaust fan/wall fan/pedestal fan of size 300/400/450mm Sweep complete all as specified and as directed.
Supply only capacitor 2.5 MFD 440 volts AC 50 Hz, as approved suitable for ceiling fan of any sweep and make complete all as specified and as directed.
Supply only capacitor 3.15 MFD 440 volts AC 50Hz, as approved suitable for ceiling fan of any sweep and make complete all as specified and as directed.
Supply only split pin for ceiling fan of any sweep and make complete all as specified and as directed.
Supply only bush (Gun metal) including lathe machining work as approved suitable for ceiling fan of any sweep and make complete all as specified and as directed
Supply only bush (Gun metal) including lathe machining work as approved suitable for exhaust fan/wall fan/pedestal fan of any sweep and make complete all as specified and as directed
S&F down rod as approved suitable for ceiling fan of any sweep and make complete all as specified and as directed.
S&F down rod clamps with rubber reel of suitable size/as ordered including necessary mild steel nut, bolts, washer etc. complete all as specified and as directed.
Hanging only ceiling fan of any sweep and make and connecting up with electric connection from ceiling rose/connector to fan including provn of cable from ceiling rose or connector to fan complete all as specified and as directed. Note : Flexible wire required is to be provided under respective items.
S&F as in repairs square/round recess mounted 12/15 W LED edge lit slim downlight with dia-cast aluminium housing finished in premium white powder coating eficacy 100 lm/w complete with all acessories internally prewired suitable for single phase 230 volts, 50 Hz AC supply including connecting up with flexible copper conductor cable of size 0.5 sq.mm (nominal area) complete all as specified and as directed.
Taking down MCB DB / Main switch of any size and making good to disturbed surface of wall/floor, etc. complete all as specified andas directed.
S&F as in repairs 415 volts, 10 KA, 'C' curve Miniature circuit breaker (MCB) of TPN, 40 to 100 Amps and current carrying capacity in the DB with connection testing and commissioning complete all as specified and as directed.
S&F as in repairs MCB, single pole, 240 volts, 40 Amps, 10 KA, 'C' curve complete all as specified and as directed.
S&F as in repairs MCB, single pole & neutral, 240 volts, 40 to 63 Amps, 'C' curve in the MCB, DB with connection including testing complete all as specified and as directed.
S&F in repairs switch bell push flush type, 5 Amps, 240 volts complete all as specified and as directed.
M&L for submain wiring with two runs of single core 6 sq.mm FRLS PVC insulated copper cable 1100 vots grade, multistrand, unsheathed conductor drawn into PVC casing and capping and all necessary fittings including 1x6 sq.mm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete including taking down old unserviceable sub main wiring of any size and making good to disturbed surfaces complete all as specified and as directed. NOTE :- The contract sum shall be derieved by deducting the amount shown in Schedule of Credit attached to this tender from total amount of Schedule 'A'/BOQ.
Chief Builders &Consultants (BID ID -3181351)
NIHAR ENTERPRISE (BID ID -3181917)
RAJGURU & CO (BID ID -3180642)
THE SUPPLY AGENCY (BID ID -3181957)
SHRI RAJEN PASWAN (BID ID -3181415)
Bidder Name
KAY CEE CO. INDIA
NIHAR ENTERPRISE
THE SUPPLY AGENCY
RAJGURU & CO
SHRI RAJEN PASWAN
Chief Builders &Consultants
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .