Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹46.9 L+₹2.0 L (4.52%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹48.3 L+₹3.4 L (7.65%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
27 Jan 2020, 6:00 pmClosed
BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
SPECIAL REPAIRS TO ROOF TREATMENT FLOORING WALL PLASTERING JOINERIES PLUMBING AND REWIRING OF COOK HOUSE OF P 334 ST COY ADDITION ALTERATION TO BLDG NO P 113 P 217 AND CERTAIN REVENUE WORKS AT PRTC UNDER GE NORTH BANGALORE
2019_MES_310557_1
8412
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Class D category a (i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹96,000
Yes
28 Feb 2020
30 Dec 2019
28 Jan 2020
30 Dec 2019
27 Jan 2020
13 Jan 2020
30 Dec 2019 - 12 Jan 2020
Amount
B/R WORKS
Taking down door frame or chowkats without taking off shutter from frame area n.exc. 1.50 sqm each all as specified and as directed.
Taking down chowkats or frame area exc. 1.5 sqm but n.exc. 4 sqm (without taking off shutters) from the frame all as specified and directed.
Pressed mild steel frames suitable for doors, box type with one or more rebates including necessary fixing lugs, hinges, lock srike plate etc complete of size 125 x 60mm all as specified and directed.
Pressed mild steel frames suitable for doors, box type with one or more rebates including necessary fixing lugs, hinges, lock srike plate etc complete of size 100 x 60mm all as specified and directed.
35 mm thick factory made second class hard wood panelled door shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both sides, size of stile and rail as per IS: 1003 (Part-I) kiln seasoned etc complete all as specified and as directed.
35 mm thick factory made door shutters second class hard wood fully glazed skeleton shutters, open rebated and prepared to receive glass, gauge etc divided into squares with plain chamfered, mitred and rebated sash bars any numbers fitted with cut and mitred beads for securing glass etc complete all as specified and as directed.
18/19 mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame work including teak wood lipping, as in cup board shutters,cup board shelves, pelmet boxes etc., complete all as specified and as directed.
PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube. fixing in opening as per specification all as specified and as directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing including 3 nos of stainless steel hinges 100mm long,2nos of Aluminium handles 100mm long and 02 nos of Aluminium anodised tower bolt 150mm long complete all as specified and as directed..
PTMT butt hinges, 100 mm long and fixed with steel screws complete all as specified.
PTMT tower bolts, 150 mm long and fixed with steel screws complete all as specified.
PTMT door handle, 150 mm long and fixed with steel screws complete all as specified Make Prayag / Polytuf.
Mild Steel windows double rebated with box type frame side hung shutters on one side glazed and other side gauzed shutter including projected type hinges, 100mm long steel handle, 150mm long tower bolt and steel peg stay all as per TD drawing-539 sheet 1/3 to 3/3 all as specified and directed Engineer-in-Charge including filling frame with PCC 1:3:6 type C0 (using 12.5mm graded stone aggregate) complete all as specified and as directed.
Mild Steel ventilators top hung shutters including peg stay complete with glazing bars all as specified and as directed.
Rolled Mild steel square bar of size 12 mm as in grills or guard bars welded to steel window all as spacefied and directed.
Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed complete all as specified and as directed.
Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed in repairs complete all as specified and as directed.
Sheet glass 3mm thick ordinary quality and glazing with silicon and securing pins n.exc. 0.50 sqm in each pane complete all as specified and as directed.
Rolled Mild Steel small articles such as hold fast, strips for rain water pipes, bends, stray support etc., all as specified and as directed.
Plain Cement Concrete, (1:3:6) type C1 using 20mm graded stone aggregate as in hold fasts, bed blocks etc., including necessary form work complete all as specified and as directed.
200mm long Aluminium anodised barrel tower bolts etc., complete all as specified and as directed.
300mm long Aluminium alloy anodised sliding door bolt (Aldrop bolt) with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed etc complete all as specified and as directed.
MS butt hinges medium weight 100mm long cold rolled all as specified and as directed.
150mm long Aluminium anodised handles fabricated type etc., complete all as specified and as directed.
Taking down cement plaster with/without tiling on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc and disposal of debris outside MD land all as specified and as directed.
Rendering 15mm thick on surface of brick work/concrete surface in CM(1:6) and finishing the surfaces even and fair without using extra cement complete all as specified and as directed.
Rendering 15mm thick in CM (1:4) on other than fair face of brick or concrete surfaces, finishing the surfaces even and fair with out using extra cement all as specified and as directed.
5mm thick rendering in cement mortar (1:3) on concrete surfaces, finishing the surfaces even and smooth without using extra cement as in ceiling complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer all as specified and as directed.
Preparation of new plastered surfaces and applying three coats of white washing on wall all as specified and as directed.
Preparation of old un treated surfaces of any description including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts, trading oil and greasy spots etc on wall surfaces and applying one coat of cement based paint all as specified and as as directed.
Preparation of new plastered surfaces and applying two coats of colour washing on wall all as specified and as directed.
Preparation of new or previously untreated wooden surfaces of any description not other wise described over 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing) removing seviceable tiles to store and rubbish off the premises
Non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tiles exceeding 0.11 sqm but n.exc. 0.18 sqm, as in floor etc set and jointed in neet cement slurry and pointed in white or coloured cement to match over including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
Glazed ceramic coloured tiles as in vertical surfaces 300 x 200 x 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over including 10 mm thick backing coat in cement mortar (1:3) on fair faces of brick work or concrete surfaces complete all as specified and as directed.
Taking up or down steel tubing 15mm dia and connections all as specified and as directed.
Taking up or down steel tubing 20mm dia and connections all as specified and as directed.
Galvanised iron tubing medium grade 15mm dia with all fittings and fixed to wall, ceiling or laid in floors etc., complete all as specified and as directed.
Galvanised iron tubing medium grade 20mm dia with all fittings and fixed to wall, ceiling or laid in floors etc., complete all as specified and as directed.
Bib taps, 15 mm bore chromium plated, fancy type, long body cast copper alloy with capstan head handle , screwed down for iron pipe or for brass ferrule fixed in repairs complete all as specified and as directed.
Stop valves, 15mm dia fixed in repairs, cast copper alloy, screwed down high pressure with crutch or butter fly handle screwed both ends or for unions etc., complete all as specified and as directed.
Gratings chromium plated of size 125 mm dia with waste hole of suitable size all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 1000 ltrs capacity complete complete all as specified and as directed.
20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed(Min weight 20mm-210 gms) all as specified and as directed.
PVC valveless, syphonic action type, flushing cistern, 10ltr capacity,low level, white, with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull, or lever, fixed in repairs complete all as specified and directed.
PVC connections 15mm dia with PTMT nuts of length of 450 mm long fixed in repairs complete all as specfied and as directed.
Vitreous china wash hand basin, white, flat back of size 630 x 450 mm excluding taps,chain and plug and porcelain stopper but including CI bracket. etc complete fixed in repairs all as specified and as directed.
15 mm dia cast copper alloy chromium plated Pillar tap fancy type screwed for iron pipe and fixed in repairs complete all as specified and as directed.
32 mm dia waste fittings, brass, chromium plated for sinks, basins, etc., with long screwed shanks and flynuts, flange end fixed in repairs complete all as specified and as directed.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including PVC(SWR) P trap connecting to flush pipe and to anti syphonage pipe, etc. complete including making good to floor fixed in repairs complete all as specified and directed.
Machine cut Cudappa stone slab as in cub board slab/ Kitchen 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including a screed bed in CM 1:6, 15mm thick complete all as specified and as directed.
Rounding to edges of stone slabs of one edge, such as in steps, cooking platform, and other similar situations complete all as specified
Demolition of un-Reinforced cement concrete in ground floors and pavings not exceeding 15 cm thick (below or above ground level) complete all as specified and as directed.
Plain Cement Concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection, 50mm thick, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints complete all as specified and as directed.
Dismantling of single layer Mangalore pattern roofing tiles or similar tiles in roofing etc complete all as specified and directed.
Dismantling of wooden timber fillets, rails, posts, rafters, purlins etc not exceeding 40 sq.cm in section all as specified and as directed.
Dismantling of timber scantlings in any position unframed work 40 sq.cm and over in section all as specified and directed.
Second class hard wood clean sawn timber scantlings in unframed work 40 sq.cm and over in section all as specified and directed.
All as per item no 1.060 but except timber.
Rolled mild steel work as in joist, channel, angle, or tee sections, as in purlins fixed independently, without connecting plates, etc. of grade Fe 410-W complete all as specified and as directed.
Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixd with self tapping screws all as specified and as directed.
As per item No 1.007 above but plain sheet for ridge.
Dismantling wall and ceiling boards (fibre pulp, insulation, etc) or insulation boards / slabs / blankets any thickness including cover fillets.etc complete all as specified and directed.
E-grid suspended false ceiling grid system of size 600mm x 600mm with main tee 32 x 24 x 0.6mm cross Tee 25 x 24 x 0.6mm and wall angle 22.2 x 22.2 x 0.5mm, ceiling suspended with 3mm dia GI wire hanger fixed with steel dash fastener, butterfly clips, hold down clips etc., (Main runner, cross Tee & wall angle of MS galvanised with PPPCGS) including 4mm thick HPSC self textured design pre primered non asbestos fibre cement building board fixed to false ceiling including one coat of oil bound emulsion distemper complete all as specified and as directed.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete of size 105 x 60mm all as specified and as directed.
Preparation of new plaster surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of oil bound distemper over a coat of alkali reistant primer over a coat of 2 mm thick white putty on walls complete all as specified and directed.
Roughening of the concrete surfaces of old concrete by picking, sweeping cleaning and washing down with water to remove dust etc complete all as specified and directed.
Demolition of brick or stone work built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles all as specified and as directed.
Brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) all as specified and directed.
Scarifying or picking gravelled, macadam or bituminous macadam surfaces, in area n.exc. 400 sqm and n.exc. 50 mm deep all as specified and directed.
Screed bed or bedding layer or mortar 15 mm thick in CM(1:4) for laying floor finishes with all as specified and directed.
Chequered cement concrete tiles of size 200 x 200 x20mm thick with white cement and pigment, set jointed and pointed in neat cement slurry as in floors all as specified and directed.
Gun metal , globe or gate valves 20mm dia, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed.
Towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats. (minimum weight 190gms) all as specified and directed.
Vitreous china bowl type urinal flat back of size 465x355x265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) all as specified and directed.
110mm bore PVC (SWR) pipe, type 'B' , single socketed in any length with rubber ring joints laid in floors complete all as specifed and as directed.
110mm bore PVC (SWR) pipe, type 'B' , single socketed in any length with rubber ring joints fixed to walls complete all as specifed and as directed.
75mm bore PVC (SWR) pipe, type 'B' , single socketed in any length with rubber ring joints laid in floors complete all as specifed and as directed.
75mm bore PVC (SWR) pipe, type 'B' , single socketed in any length with rubber ring joints fixed to walls complete all as specifed and as directed.
PVC (SWR) bends any radius 75 mm dia, type 'B' with access door complete all as specified and as directed.
PVC (SWR) bends any radius 110 mm dia, type 'B' complete all as specified and as directed.
PVC(SWR) multi floor trap 75 mm dia with gratings including jointing with solvent cement all as specified and as directed.
Complete removal of existing roof treatment (tarfelt) and removing debris to a distance of n.exc 50m all as specified and as directed.
Plain Cement Concrete, (1:2;4), type B-1, 40mm thick using 20mm graded stone aggregate including finishing cement concrete surface even and rough to receive finishing coats complete all as specified and as directed.
Screed bed or bedding layer of 15mm thick for laying floor finishes in CM (1:4) mixed with approved water proofing compound all as speciifed and as directed. Note: Water proofing liquid shall be measured and paid separately.
Supply only integral liquid water proofing compound all as specified and as directed.
Roof treatment by applying bitumen primer @ 0.27kg/sqm, providing 3mm thick APP modified water proofing membrane weighing not less than 3.8 kg/sqm reinforced with non woven polyester matt weighing not less than 180gm/sqm, having softening point not less than 140 centigrade, having tensile strength of 650 N/sq.cm in longitudinal and transverse directions, the reinforced tearing strength of 180N by torch application with minimum 10cm side overlap and 15cm end lap applying a coat of blown grade hot bitumen VG-10 over the membrane @ 1.2kg/sqm, top of membrane shall than be finished with solar reflective bituminous aluminium paint @0.10kg/sqm all as specified and as directed.
Non skid ceramic coloured tiles7 to 8 mm thick (square) area of each tiles exceeding 0.06 Sqm but nexc 0.11 sqm, in floor etc set and jointed in neet cement slurry and pointed in white or coloured cement to match over including 15 mm thick screed bed in cement mortar (1:6)all as specified and directed.
Rendering 10mm thick on surface of brick work/concrete surface in CM(1:6) and finishing the surfaces even and fair without using extra cement complete all as specified and as directed.
Preparation of old un treated surfaces of any description including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts, trading oil and greasy spots etc on wall surfaces and applying one coat of oil bound emulsion distemper all as specified and as as directed.
Preparation of old un treated surfaces of any description including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts, trading oil and greasy spots etc on wall surfaces and applying one coat of cement based paint all as specified and as as directed.
Preparation of old un treated surfaces of any description including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts, trading oil and greasy spots etc on wall surfaces and applying one coat of white wash all as specified and as as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazzing pins/ spring clips and providing and fixing new one all as specified and as directed.
Preparation of old painted wooden surfaces of any description and applying one coats of synthetic enamel paint complete all as specified and as directed.
Preparation of old painted steel surfaces of any description and applying one coats of synthetic enamel paint complete all as specified and as directed.
125mm dia brass chromium plated shower rose with swivel joints fixed and repairs all as specified and as directed.
Refixing of old 15mm dia steel tubing and connections in new or old position to fixed to walls, ceiling or laid in floors etc., complete all as specified and as directed.
Refixing of old 20mm dia steel tubing and connections in new or old position to fixed to walls, ceiling or laid in floors etc., complete all as specified and as directed.
Drapery rods, 25 mm dia, having corrugated PVC extrusion on electric resistance welded MS pipe with fancy type 02 nos knob and 02 nos brackets for each door/windows etc complete all as specified directed Make : soffio II of Vista
Precast cement concrete block masonry with solid blocks type C1 (1:3:6) using 12.5 mm graded stone aggregate exc. 10 cm in width and setting in cement mortar(1:6) complete all as specified and as directed.
TMT bars 10mm dia and over cut to length bent to shape required, including, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
All as per Sl Item No. 1.104 here in before but 6mm dia and over upto and including 10mm dia as in stirrups, spacers and binders all as specified and as directed.
Use and waste of form work to soffits of suspended slab such as roof slab, floor slas, landing and similar work n.exc. 200 mm thick all as specified and as directed.
Reinforced Cement Concrete (1:2;4), type B-1, using 20mm graded stone aggregate as in slabs supported on walls, beam in roofs, flooring, landing, balconies, canopies,deck slab & in sheves & the like all as specified and as directed.
Rolled mild steel work as in tubular trusses, purlins etc., including special shaped washers etc., complete using ERW or incduction butt weld tubes conforming to IS 1161-1979 Gde St-240 and painted with one shop coat of zinc chromate primer including preparation of surfaces at contractor's workshop before fabrication complete all as pecified and as directed.
Excavating in post holes (or similar holes) each n. exc. 0.5 cum, getting out in any type of soil, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm thick all as specified and as directed.
Plain Cement Concrete as in foundation filling and mass concrete, type D-2, (1:4:8), using 40 mm graded stone aggregate complete all as specified and as directed.
Excavating in trenches, n exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc. 10 sq m on plan and n.exc. 1.5 m in depth and getting out in hard/dense soil all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thickness all as specified and as directed.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 m above the starting point all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 ltrs capacity complete complete all as specified and as directed.
Gun metal globe valve 20mm dia, high pressure,with polythene float and flynut complete 20mm screwed for iron pipe or brass ferrule and fixed all as specified and as directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and as directed.
Hardcore of guage exc. 63mm, broken stone or boulders, deposited, spread and levelled in layers n.exc. 15cm thick, watered and rammed to a true surface all as specified and as directed.
Plain Cement Concrete, (1:4:8), type D2 using 40mm graded stone aggregate as in sub base to floors, 75mm thick all as specified and as directed.
Plain Cement Concrete, (1:2:4), type B-1, using 20 mm graded stone aggregate as in sub base to floors, 25 mm thick all as specified and as directed.
Plain Cement Concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in floor topping, 40mm thick, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Supply only 38mmx3mm glass dividing strips as in floors complete all as specified and as directed.
Plain Cement Concrete, (1:3:6), type C2, using 40 mm graded stone aggregate as in foundations, filling and mass concrete all as specified and as directed.
Rolled mild steel tubes medium grade as in posts and struts and wind ties for roof including securing bolts, including all necessary drilling, bolting or riverting etc. and similar work conforming to Fe 410-0 or FE 310-0 all as specified and as directed.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (beam, tee, angle, channel or flat sections), distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-B including fabrication, erraction and fixing complete all as specified and as directed.
Stone masonry, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6, complete all as specified and as directed.
Brick work with sub class B bricks, straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified.
Brick work with sub class B bricks, straight or curved on plan to any radius in half brick thick wall built in CM (1:4) complete all as specified.
Providing precast cement concrete(1:2:4) type B0 using 12.5 mm graded stone aggregate as in window or door cills,lintels and setting in mortar complete with joints to match all as specified and directed.
Form work to edges of concrete flats treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors and roofs n.exc. 20 cm wide and similar works exc. 10 cm and n.exc 20 cm wide etc all as specified and directed.
Rendering on ceiling 10mm thick in CM 1:3 on fair faces of concrete surfaces finished even and smooth without using extra cement.
Preparation of newly plastered surfaces and applying three coats of white wash on vertical surfaces of walls all as specified and as directed.
Preparation of newly plastered surfaces and applying three coats of white wash on ceiling all as specified and as directed.
Plain Cement Concrete, (1:2:4), type B-1, using 20 mm graded stone aggregate as in lintels, cills, steps, sesmic and similar bands etc., all as specified and directed
Bib taps standard of PTMT any colour screwed for iron pipe suitable for 15mm dia fixed in repairs all as directed.
Vitreous China wash basin, white, flat back, size 550 X 400mm excluding taps, waste, chain and plug and percelain stopper but incl brackets all as specified and as directed.
Vitreous china ladies urinal pot of size 450 x 350 x 100 mm snow white complete all as specified and as directed.
Concussive push button taps, 15mm dia, cast copper alloy, screwed for iron pipe and fixed complete all as specified and as directed.
PVC (SWR) gully trap 125/110mm setting and jointing with solvent cement complete all as specified and as directed.
Plain Cement Concrete, (1:3:6), type C-2, using 40 mm graded stone aggregate, 75mm thick as in plinth protection complete all as specified and as directed.
Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed.
Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) suitable for 75mm dia of outlet pipe complete all as specified and as directed.
Cast iron Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) for 75mm dia of outlet pipe.
Reinforced Cement Concrete pipes 150mm dia, class NP-2, laid and jointed complete with collars all as specified and as directed.
Plain Cement Concrete bed to drains pipes suitable for 150mm dia pipes including packing under and haunching aginst the sides of pipes after they are laid and tested in cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm dia pipe.
E/M Works
Taking down carefully aluminium / copper wiring / power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Wiring complete with 1.5 Sq.mm single core FRLS PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade includiing all accessories surface type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one light point controlled by one switch.
All as per Sl Item No. 2.002 above but for one fan point controlled by one switch / regulator.
All as per Sl Item No. 2.002 above but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.002 above but for one 3 pin socket out let 5 Amps on same board.
All as per Srl item No 2.002 here-in-before but for 16 Amps socket outlet by using 2.5 sq.mm FRLS PVC insulated unsheathed copper conductor multi stranded on independent board including provn of 2.5 sq.mm PVC insulated solid copper conductor as contineous earth wire. Note for Item No 2.002 to 2.006 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
Switch piano flush type single pole one way 5 Amps all as specified and as directed.
Switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and as directed.
Switch socket combination 2 in 1 , 5 Amps flush type all as specified and as directed.
LED batten suitable for indoor applications 18 Watts,4 feet with polycarbonate housing & integrated LED channel with white arcylic cover all as per Bajaj Cat No..BCLSB 18 WH / WIPRO Cat No. LL20-221-XXX-65-NE or techno commercially equivalent makes specified in PS complete with all accessories all as specified and directed.
Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed.
Stepped type electronic fan regulator flush type 5 Amps all as specified and as directed.
Angle holder, PVC / polycarbonate type all as specified and as directed.
Removing of existing and provision of new MCB single pole 240 volts 5 to 40 Amps complete all as specified and as directed
Removing of existing and provision of new MCB SPN 240 volts 40 Amps complete all as specified and as directed
Replacement of MCB DB TPN 4 way double door 415 volts with 200 Amps rated busbar for housing of MCB incoming and MCBs outgoing all as specified and as directed.
Replacement of MCB TPN 415 volts 63 Amps complete all as specified and as directed
36 Watt LED building security light fitting with pressure die cast housing, toughened glass and indivudial LEDs with secondary optics and IP 66 protection all as per Bajaj Cat No..Cat No.:- BRTFG 36W LED or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Bracket made out of GI tubing medium grade 40 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from building complete all as specified and directed.
Dismantling, greasing, servicing and spray painting of ceiling fans / exhaust fan complete, in situ with one coat of synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dust etc.,. and re-fixing with downrod & clamps complete all as specified and as directed
Removing of existing and provision of new sub main wiring 1100 volts grade multistranded copper conductors, two runs of single core 4 sq.mm along with 4 sq.mm FRLS PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed
Removing of existing and provision of new sub main wiring 1100 volts grade multistranded copper conductors, four runs of single core 6 sq.mm along with 2 runs of 6 sq.mm FRLS PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed. NOTE:- four runs of cable, two runs of cable and one run of PVC conduit shall be me measured as one unit for payment purpose.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
Replacement of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20Amps all as specified and as directed.
LED tube light fitting 10 watt 6000 K (2 feet long) wall mounted industrial batten type, connector block etc, complete with all acessories internally pre-wired and including connecting up twin core twist flexible copper conductor cable all as pe Bajaj Model No : BCLSB 10 WH/ WIPRO Model No.LL20-111-XXX-65-NE or techno commrcially equivalent makes specified in PS complete all as specified and as directed.
Removing of existing and provision of new MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed.
Skyline LED fitting 30 Watt building security light having high power LED with pressure die cast including lamp complete all as specified and as directed.
Sand cushioning in layers for cables in trenches / ducts for cable including consolidation complete all as specified and directed. NOTE: Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq.mm 3.5 core connected with suitable lugs complete all as specified and as directed.
Galvanised Iron tubing, light grade, 50 mm bore with fittings and fixture for protection of cable laid at road crossing / on pole / trenches complete all as specified and as directed.
Wiring complete with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit including accessories concealed type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one light point controlled by one switch.
All as per Sl Item No. 2.032 above but for one 3 pin socket out let 5 Amps on independent board
All as per Sl Item No. 2.032 above but for one 3 pin socket out let 5 Amp on same board
Wiring complete with 2.5sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit incl accessories concealed run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. Note for Item No 2.032 to 2.035 :- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring
MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed.
MCB single pole 240 volts 5 to 40 Amps complete all as specified and as directed
MCB SPN 240 volts 32 Amps complete all as specified and as directed
XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq.mm 2 core connected with suitable lugs complete all as specified and as directed.
DARSHAN CONSTRUCTION CO
P R S ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .