Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹21.8 L+₹2.9 L (15.4%)Rejected-Finance 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-Finance BEING L2 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
11 Jul 2023, 6:00 pmClosed
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIRS/CLEANING OF SEWAGE LINE, SEPTIC TANK AND MANHOLES AT AFS MADH ISLAND UNDER GE AF THANE
2023_MES_601339_1
8282/E8
Open Tender
Civil Works - Others
Item Rate
330 days
THANE
AS PER NIT AND TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹16,000
Yes
23 Sept 2023
6 Jun 2023
12 Jul 2023
6 Jun 2023
11 Jul 2023
29 Jun 2023
6 Jun 2023 - 29 Jun 2023
Amount
M&L for cleaning/clear of blockage of manholes, gully traps, floor traps, vertical soil/waste pipe of different dia and sewage line in the area of AF station Mumbai (Domestic and Tech area) by providing and deployment of 02 (TWO) Nos of Labours per day including Sundays and Holidays. Note : a) The labour (02 nos) will report daily at 0845 hrs on all working days including Sundays and holidays at complaint cell centre to attend complaints given by Engr -In- Charge . Complaints needs to be cleared within 24 hrs after receiving the complaints. The contractor will deploy requisite labour and supply all T&P ( mechanical Iron rods, knot ropes , bamboo etc.) scaffolding ladders any other materials required to clear the blockages at the site without any extra cost .Labour for cleaning of sludge from sewage lines (any dia) to manhole is included in quoted rates. In case any labour does not report to Engineer In Charge for the whole day or found missing more than half an hour on any day, Panel recovery @ RS.900/- per head per day shall be made proportionally from contractor's dues. b) The recovery will be made from the contractor @250 Rs per complaint which are not cleared within 24 hrs from the date and time of receipt of complaints. Decision of Engr-In- Charge is final in this respect. Two persons will be provided by the contractor at site. The above item includes conveyance cost of labour with their tools to travel from pocket to pocket to attend complaints including removal of sludge from the site outside MOD land to a distance not exc 5km (The department shall not be liable to provide any kind/form of transportation to the labour). (c) Registers of labour attendance and complaints slips shall be maintained by contractor at their own cost, which shall be kept in the custody of MES Department(complaint cell) duly signed by contractor's representative ,JE(civil) and Engineer in charge.
Opening of cover ,de-watering and taking out sludge from septic tank of any size and removing sludge out side MD land and cleaning the septic tank as per BMC rules and placing cover in original position,complete all as specified and directed by Engr-in-Charge.
Cleaning and removing all scale and dirt, etc, from tanks of capacity exc 250 & not exc 500 in liters and from mouths of curculating pipes, etc all as specified and directed by Engineer-in-Charge
Cleaning and removing all scale and dirt, etc, from tanks of capacity exc 500 & not exc 1000 in liters and from mouths of curculating pipes, etc all as specified and directed by Engineer-in-Charge.
Demolition of brick masonary built in cement mortar including all quions, arches, pillars etc but including ashlars facings, dressed stone work and pre cast concrete articles all as specified and directed by Engr-in-Charge and
M&L cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in benching and coping ,complete all as specified and directed by Engr-in-Charge.
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc. ,complete all as specified and directed by Engr-in-Charge.
M&L for brickwork with subclass ‘B’ brickwork straight on plan exc 6m mean radius with old size bricks built in CM 1:4 ,complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15mm thick (10 mm thick backing coat in CM 1:6 and 5 mm thick finishing coat in CM 1:4) on other than fair faces of brick work/stone surface in cement mortar 1:4 mixed with water proofing compound including finished even and smooth with using extra cement for manholes ,complete all as specified and directed by Engr-in-Charge Note :- WPC will be measured and paid separaterly under relevent item of Sch A.
Supply only liquid water proofing compound ,complete all as specified and directed by Engr-in-Charge.
M & L ,PVC (SWR) multi floor trap plain of 63mm outet Dia with grating including jointing with solvent cement ,complete all as specified and directed by Engr-in-Charge.
M & L ,PVC (SWR) multi floor trap plain of 75mm outet Dia with grating including jointing with solvent cement ,complete all as specified and directed by Engr-in-Charge.
M & L , PVC (SWR) Gully Trap 125/110 mm ,setting and jointing with solvent cement,complete all as specified and directed by Engr-in-Charge
M & L PVC (SWR) Nahani trap plain of Dia 75mm with grating including jointing with solvent cement ,complete all as specified and directed by Engr-in-Charge.
S & F in repair PVC SWR pipes single socketed, in any length with rubber ring joints laid in trenches or in floors 110mm dia ,complete all as specified and directed by Engr-in-Charge.
S & F in repair PVC SWR bends of 110mm bore ,complete all as specified and directed by Engr-in-Charge.
S & F in repair PVC SWR bends of 75mm bore ,complete all as specified and directed by Engr-in-Charge.
S & F in repair PVC SWR branch piece doule Y equal or unequal 75 mm bore ,complete all as specified and directed by Engr-in-Charge.
S & F in repair PVC SWR branch piece ,single y equal or unequal of 75mm bore ,complete all as specified and directed by Engr-in-Charge.
S & F in repair PVC SWR branch piece single Y equal or unequal 110 mm bore ,complete all as specified and directed by Engr-in-Charge.
S & F PVC (SWR ) Couplers 75mm bore,complete all as specified and directed by Engr-in-Charge.
S & F PVC (SWR) Couplers 110mm bore ,complete all as specified and directed by Engr-in-Charge.
S & F PVC (SWR) reducer 110mm bore ,complete all as specified and directed by Engr-in-Charge.
S & F in repair PVC SWR branch piece doule Y equal or unequal 110 mm bore, complete all as specified and directed by Engr-in-Charge.
Demolition of reinforced cement concrete of any description as in any position & removing Demolition materials , complete all as specified and directed by Engr-in-Charge.
M&L for providing precast cement concrete type B1 1:2:4 (20mm graded stone aggregate) in apex stones,etc including chamfers,weatherings throating etc and setting in mortar 1:4 (for manholes etc.) ,complete all as specified and directed by Engr-in-Charge.
M&L for TMT steel bars 6mm dia to 8mm dia & over cut to length bent to shape required including cranking bending spirally for hoping for columns and binding with MS wire not exc than 0.9mm dia. ,complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n. exc 1.5m wide and n. exc 1.5m depth for foundation etc and getting out in hard/dense soil ,complete all as specified and directed by Engr-in-Charge.
Demolition PCC and taking up break/decayed drain pipe (Salt glazed ware, AC or Reinforced concrete) 150 mm dia pipe from Cement mortor and depositing the debries where as directed to a distance n exc. 50m ,complete all as specified and directed by Engr-in-Charge. .
Demolition PCC and taking up break/decayed drain pipe (Salt glazed ware, AC or Reinforced concrete) 100 mm dia pipe from Cement mortor and depositing the debries where as directed to a distance n exc. 50m ,complete all as specified and directed by Engr-in-Charge.
S&F 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches and jointed as specified and directed by Engr-in-Charge ,complete all as specified and directed by Engr-in-Charge.
S&F 100mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches and jointed as specified and directed by Engr-in-Charge ,complete all as specified and directed by Engr-in-Charge.
M&L concrete bed of cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) to drain pipes including packing under ,and hunching against the sides of pipe after they are laid and tested for bore of pipe is 150mm ,complete all as specified and directed by Engr-in-Charge.
M&L concrete bed of cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) to drain pipes including packing under ,and hunching against the sides of pipe after they are laid and tested for bore of pipe is 100mm complete all as specified and directed by Engr-in-Charge.
Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm and directed by Engr-in-Charge.
Removing excavated material (Soil) exc. 500m but n exc. 1.50 km distance and depositing where directed by Engr-in-Charge.
M & L for complete removal of existing treatment on surface of wall etc in any position washing down with water and clearing the surface from all loose dirt, chalk, grease, fungi, algai, flakes etc, and applying two coats of weather proof acrylic paint over a coat of weather proof primer with camouflage pattern complete all as specified and directed by Engr - in - Charge.
M & L for preparation of old surface by bio wash, scrapping and cleaning etc of slope roof of concrete, asbestos cement sheet and applying two coats of weatherproof acrylic paint over a coat of weather proof primer with camouflage pattern complete all as specified and directed by Engr - in - Charge.
M & L for preperation of old painted steel surface and applying two coat of acrylic emulsion paint over a coat of acrylic primer in different shades with camouflage pattern complete all as specified and directed by Engr - in - Charge.
M&L for preparation of plastered or unplastered old treated surfaces of walls and applying one coat of white wash on walls etc complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of plastered or unplastered surfaces of walls and applying two coats of white wash on walls etc complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of plastered or unplastered old treated surfaces of ceiling and applying one coat of white wash to ceiling etc complete all as specified and as directed by Engineer-in-Charge.
Ditto as per Srl item No 42.00 above but in two coats
M&L for preparation of old treated plastered or un-plastered surfaces of wall and applying one coat of oil bound distember etc,complete all as specified and as directed by Engineer-in- Charge.
Ditto as per Srl item No 44.00 above but in two coats
M&L for preparation of old treated wood surfaces of any description over 10 cm width & girth not otherwise described and applying one coat of synthetic enamel paint ,complete all as specified and as directed by Engineer-in- Charge.
M&L for 2mm thick wall care putty on wall including removal of existing treatment and preparation of surfaces to recieve the new treatment etc ,complete all as specified and as directed by Engineer-in- Charge.
M&L for 2mm thick wall care putty on ceiling including removal of existing treatment and preparation of surfaces to recieve the new treatment etc ,complete all as specified and as directed by Engr-in-charge.
Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site ,complete all as specified and as directed by Engineer-in- Charge.
Rendering 15 mm thick in cement mortar 1:6 on brick / concrete surfaces finished even and smooth with neeru finish ,complete all as specified and as directed by Engineer-in- Charge.
Rendering 10mm thick as in CM 1:3 on ceiling and finishing the surface even and fair ,complete all as specified and as directed by Engr-in-charge.
M&L for preparation of newly plastered surface of wall and applying two coat of oil bound distemper over a coat of alkali resistance primer ,complete all as specified and as directed by Engr-in-charge.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distember on ceiling etc, complete all as specified and as directed by Engineer-in- charge.
S&F ball brass valve, high pressure, with ploythene float and flynut complete, screwed for iron pipe or brass ferrule 20 mm bore dia , complete all as specified and as directed by Engineer-in- charge.
Ditto as per Srl Item No 54.00 above but for 15 mm bore dia
Dismantling floor hearth or tiling including cement morter bedding (but not backing) removing servicable tiles to store and rubbish off the premies , complete all as specified and as directed by Engineer-in- charge.
M&L non skid ceramic tiles(Coloured) rectitied 7 to 8mm thick (square/rectangular) area of each tile exc 0.06sqm but n.exc 0.11 sqm, in in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including screed bed 15mm thick in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L Coloured Glazed Ceramic tiles 300 x 450 and 6-7mm thick on vertical surfaces such as skirting, dados and risers to steps etc including 10mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer-in-Charge..
S&F in repairs stainless steel wire mesh in repairs, 0.36mm nominal dia of wire with 1.40mm average aperture and fixed with aluminium wire staples ,complete all as specified and as directed by Engineer-in- Charge.
S&F in repairs 15mm dia bib taps, Chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule ,complete all as specified and as directed by Engineer-in- Charge.
S&F in repairs 15mm dia Stop valves, cast copper alloy chromium plated screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed ,complete all as specified and as directed by Engineer-in- Charge.
S&F in repairs 15mm dia pillar taps cast copper alloy with capstan heads chromium plated fancy type screwed down high pressure with or without lettered hot or cold with long screwed for iron pipe ,complete all as specified and as directed by Engineer-in- Charge.
S&F in repairs GI tubing 20mm bore dia, medium grade including all fittings fixed in floor /walls/ ceilling etc ,complete all as specified and as directed by Engineer-in- Charge.
S&F in repairs GI tubing of15mm bore dia ,medium grade including all fittings fixed in floor /walls / ceilling etc, complete all as specified and as directed by Engineer-in- Charge.
S&F in repair CP brass shower rose of 125mm dia swivel joints including fixing to steel pipe or union ,complete all as specified and as directed by Engineer-in- Charge.
S&F in repairs Harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc. ,complete all as specified and as directed by Engineer-in- Charge.
S&F in repairs Brass Chromium plated Tubular towel rail 20mm dia ,complete all as specified and as directed by Engineer-in- Charge.
S&F in repairs Brass Chromium plated Tubular towel ring, 20mm dia, D type, 60cm long between flanges ,complete all as specified and as directed by Engineer-in- Charge.
S&F Soap dish, any type, fixed to plugs with chromium plated brass screws ,complete all as specified and as directed by Engineer-in- Charge.
Taking down aluminium sliding windows of any description and any size and replacing the worn out, broken wiremesh, aluminium sections, glass grill, rubber beading, rollers, locks etc as required and refixing back into the same opening for easy movement of shutters including necessary fittings and fixtures (Note : Items such as i) Wiremesh, ii) Glass, iii) Grill, iv) Rubber beeding, v) Rollers, vi) Locks, vii) Aluminium sections etc will be paid seperately under respective items as supply only)
Supply only Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each pane ,complete all as specified and as directed by Engineer-in- Charge.
Supply only Sheet glass, ordinary quality, in squares exc 0.5 sq. m each pane ,complete all as specified and as directed by Engineer-in- Charge.
S & F in Repairs PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of 10 Ltr Capacity
M&L for providing of 20 mm thick Granite (of any type ) work (table rubbed and polished) in steps, jambs, pillars, win dow/door -cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match shade of granite over 10 mm thick screed bed in cement mortor 1:6 ,complete all as specified and as directed by Engineer-in- Charge.
Excavation in trenches n. exc. 1.5 M in width and 1.5 M in deep for laying of pipes and getting out in Soft / loose soil complete all as specified and directed
M&L for providing crushed stone sand cushioning to UG cable including punning down of sand in layers , complete all as specified and as directed by Engineer-in- charge.
Taking out serviceable unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm during excation of trenches and relaying after cable laying in trenches all as specified and directed.
S&F unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm during excation of trenches all as specified and directed.
Taking down GI pipe laying in trenches for UG cable protection of any sizes pipe complete all as specified and as diercted.
Supply and lay in trenches / along the wall / floor pipes GI light grade of size 80 mm with and including all fittings and accessories complete all as specified and and directed for cable protection complete all as specified and directed.
Supply and lay in trenches / along the wall / floor pipes GI light grade of size 40 mm with and including all fittings and accessories for cable protection complete all as specified and directed .
Taking down any sizes of of LT UG cable XLPE with aluminum conductor multistranded , PVC insulated and PVC sheeted heavy duty 1100 Volts grade under ground cable complete all as specified and as directed.
Supply and lay cable XLPE Insulated armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 10 sq mm 4 Core, complete all as specified and directed.
Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables (heavy duty) 1100 Volts grade cross sectional area with stranded aluminium conductor of size 16 sq mm 4 Core complete all as specified and directed.
Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 35 sq mm 3.5 Core complete all as specified and directed.
Supply and lay of LT UG cable XLPE with aluminum conductor multistranded 1100 volts grade in armored, heavy duty electric power cables with stranded aluminium conductor, 1100 volts grade, cross-sectional area of size 70 sq mm 3.5 Core complete all as specified and directed.
S&F Cable jointing kit for 1100V (Earthed) grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed.
M&L for cutting existing road/hard standing not exc 50x60 cm in wide & depth getting out excavated material for laying GI tube , for passing through LT cable, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:1.5:3; including removal of surplus soil complete all as specified and directed.
M & L for maintenance free chemical Gel based earthing, GI Pipe in Pipe type having 80 mm dia 3 mtr long GI pipe(Wall thickness of 3.2 mm) 50 Kg back fill compound all as required at site including testing on completion and taking down of old earthing all as directed by Engr in-Charge.Note : (a) Earth resistance of earth pit should be less than 1.0 Ohms on testing after completion. If the desired earth resistance is not obtained the earthing will be redone at no extra cost.
S&F,in repair,Copper Strip of size 20 x3 mm, complete all as specified and directed by Engr - in - charge.
Demolition of Cement concrete in ground floor and paving n.exc 15 cm thickness (below or above) ground level including removal, complete all as specified and as directed by Engineer-in- charge.
Supply and in repairs MCCB DB verticle type made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T CAT NO-DBVTH004DD/ / LEGRAND CAT NO-607913/ equivalent of ABB
Supply in repair MCCB DB verticle type made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 8 way Double door , L&T CAT NO-DBVTH004DD/ / LEGRAND CAT NO-607913/ equivalent of ABB
M&L for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate as in sub base to floor 100 mm thick finished even and smooth without using extra cement complete all as specified and directed.
S & F in replacement MCCB 415 volts grade with adjustable short circuit and over load of following rating :- Make: L&T/Havells/Legrand
63 Amps, 16 KA, 3 Pole
100 Amps, 16 KA, 3 Pole
125 Amps, 16 KA, 3Pole
160 Amps, 36 KA, 3 Pole
200 Amps, 36KA, 3 Pole
250 Amps, 36 KA, 3 Pole
400 Amps, 36 KA, 3 Pole
M&L for MS chequered plates of not less than 6 mm thick of sizes Fe 410-W (Gde E- 250) Quality 'A' incl cutting , welding of strip on the edges for proper fixing and provn of handles for lifting & fixing arrangement as shown & directed.incl taking out the old & unserviceble chequered plates.including one coat of primer & 2 coats of synthetic enamelled paint of approved colour , complete all as specified and as directed by Engineer-in- charge.
Material and Labour for repairing of LT Panel of not exc of sizes 2.5 Mtr x 2 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engineer-in-Charge.
Material and Labour for repairing of LT Panel of not exc of sizes 2 Mtr x 1.5 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engineer-in-Charge.
Material and Labour for repairing of feeder pillar box of not exc of sizes 2 Mtr x 1.5 Mtr x 0.80 Mtr doors/shuttering to welding and bracing of hinges, tinkering, and replace worn out rusted unserviceable doors/compartment shutters front sides and back side lock system including replace worn out rubber gaskets/feeding of compartment doors/shutters, decorbonising of all cable terminals, Busbars (R,Y,B &N) aluminium/copper cleaning inside of panel housing with help of air belower heavy duty complete all as specified and directed by Engineer-in-Charge
S&F, in replacement of LED indication lamp for indication of (R,Y,B) 230 Volts including connections and taking out unserviceable indication Lamp , complete all as specified and as directed by Engineer-in- charge.
S&F, in replacement of Volt meter 0-500 Volt digital type including connections and taking out unserviceable Volt meter complete all as specified and directed
S&F, in replacement of Ampere meter 0-400Amps digital type including connections , complete all as specified and as directed by Engineer-in- charge.
S&F, in replacement of epoxy insulators suitable to fixing of earth conducors including all fixing accessories saddles. screws, Nut and bolts ,complete all as specified and directed by Engineer-in-Charge.
Material and labour for painting of ceiling fan of any sweep with blades, down rod for any size and type,scraping out of old paint, filling of cavities with filler preparation of body painting by spray with first quality synthetic enamel paint and writing of MES number complete all as directed by Engr-in-Charge.
Material and Labour for painting of exhaust fan of any size with louvers, scraping out of old paint filling of cavities with filler preparation of body and cleaning of dust etc and painting by spray with first quality synthetic enamel paint over a coat of zinc primer and writing of MES number, complete all as specified and as directed by Engineer-in- charge.
Material and Labour for painting of pedestal fan of any size and type,scraping out of old paint filling of cavities with filler preparation of body and cleaning of dust etc and painting by spray with first quality synthetic enamel paint and writing of MES number , complete all as specified and as directed by Engineer-in- charge
Material and Labour for painting of wall mounted fan of any size and type,scraping out of old paint filling of cavities with filler preparation of body and cleaning of dust etc and painting by spray with first quality synthetic enamel paint and writing of MES number, complete all as specified and as directed by Engineer-in- charge
Material and Labour for dismantlng and opening of stator and rotor,cutting and removing burnt unserviceable winding wire from slots, cleaning of slots, rewinding with super enameled copper insulated wire as per existing gauge, varnishing,heating assembling with wire stator coil to connector block and pre-wire for connector block to ceiling rose suitable size PVC insulaed sheathed 1100 Volts grade 3 core 1.5sqmm flexible round insulaed stranded copper condutors cable required at site condition and testing complete all as directed by Engr-in- Charge for the following sweep fans of sizes as given below :-
Ceiling fan of 1200 mm sweep
Ceiling fan of 1400 mm sweep
Exhaust fan of 300 mm sweep
Exhaust fan of 450 mm sweep
Wall Mounted fan of 400 mm sweep
Pedestal fan of 400 mm sweep
S&F, in replacement of Capacitor 2.5 Mfd/3.15 Mfd 230 volts 50Hz complete all as directed by Engineer-in-Charge
S&F, in replacement of Capacitor 4.0 Mfd 230 volts 50Hz complete all as directed by Engineer-in-Charge
S&F, in replacement of down rod of 300 mm long suitable for ceiling fan complete all as directed by Engineer-in- charge.
S&F, in replacement of down rod of 600 mm long suitable for ceiling fan complete all as directed by Engineer-in-Charge.
S&F, in replacement of down rod of 1.0 m long suitable for ceiling fan complete all as directed by Engineer-in-Charge.
S&F, in replacement of Ball bearing suitable for ceiling fan with Cat part No 6201/6202 complete all as directed by Engineer-in-Charge MAKE : SKF,TATA,NBC
S&F, in replacement of Ball bearing for Wall Fan/ pedestal fan of any size or sweep complete all as directed by Engineer-in-charge MAKE : SKF,TATA,NBC
S&F, in replacement of Ball bearing suitable for exhaust fan of 300 mm /450 mm sweep/size complete all as directed by Engineer-in-charge.MAKE : SKF,TATA,NBC
S&F, in replacement of Gun Metal bush suitable for ceiling fan, exhaust fan etc complete all as directed by Engineer-in- charge
S&F, in replacement of blade made of aluminium and suitable to existing colour/size of ceiling fan 1200/1400 mm sweep including bolts and washers complete all as directed by Engineer-in-charge Make : Bajaj/Crompton/Orient /Usha
S&F, in replacement of blade made of cast iron suitable to existing colour/size of exhaust fan 300 mm sweep with nut, bolt, washers complete all as directed by Engineer-in-charge. Make : Bajaj/Shakti/Crompton
S&F, in replacement of blade made of cast iron suitable to existing colour/size of exhaust fan 450 mm sweep including nut, bolt,washers complete all as directed by Engineer-in-charge. Make : Bajaj/Shakti/Crompton/Usha
S&F, in replacement of blade made of aluminium/ PVC biody suitable to existing colour/size of wall mounted/pedestal fan 400 mm sweep including suitable size bolts complete all as directed by Engineer-in-charge.Make : Bajaj/Shakti/Crompton/Usha
Supply only canopy made of PVC body suitable for existing ceiling fan/wall mounted/pedestal fan complete all asdirected by Engineer-in-charge.
Supply only bracket with frame Nut,Bolt,Rubbers etc suitable for exhaust 300 mm sweep complete all as specified and directed.
Supply only bracket with frame Nut,Bolt,Rubbers etc suitable for exhaust 450mm sweep complete all as specified and directed.
Supply & Fixing in repair of Electronic Regulator Step down type 230 volts, AC, 50Hz including taking out unserviceable regulator of any type complete all directed by Engineer--in-charge.
Supply and fixing in repairs of electronic dimmers, 450 watt, 240 volt, flush type on the existing phenolic/ Hylum laminated sheet as site requirement complete all as directed by Engineer-in-charge.
Supply & Fix in repair of Exhaust Fan louvers of size 450 mm sweep as per sample of metal body with nut bolt and washers and anchor fastner for fixing complete all as directed by Engineer-in-Charge. Make : Bajaj/Shakti/Crompton/Usha
Supply & Fixing in repair of Exhaust fan louvers of size 300 mm sweep as per sample of metal body complete all as directed by Engineer-in-Charge. Make : Bajaj/Shakti/Crompton
Supply and fixing in repairs of Anchor fastner for hanging of ceiling Fan and necessary fittings complete all as directed by Engineer-in-Charge.
Supply and fixing in repairs hanging clamps, nut, boltswashers, spring washers, split sefty pin and rubber real suiable for ceiling fan complete all as directed by Engineer-in- Charge.
Material and Labour for PVC insulaed sheathed flexible type over all round insulated 1100 Volts grade 3 core 1.5sqmm stranded copper condutors cable required at site condition and testing complete all as directed by Engr-in- Charge.
Supply and fixing in repairs oscillation mechanism suitable for wall mounted fan/pedestal fan complete all as directed by Engr-in- Charge.
M/s Mukesh Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .