Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹43.6 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹46.6 L+₹2.7 L (6.17%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹48.5 L+₹4.7 L (10.6%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹52.1 L+₹8.2 L (18.7%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹52.7 L+₹8.8 L (20.1%)Rejected-Finance | L-5 | Rejected-Finance L-5 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
1 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) FARIDABAD
GE (AF) FARIDABAD
ADDN/ALTN OF BLDG NO P-39, WASH ROOM AND CERTAIN B/R E/M PROVN WORK AT MCC BASANT NAGAR IN AOR OF GE (AF) FARIDABAD (2ND CALL)
2022_MES_568863_2
GE (FBD)/AF-67/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Delhi
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) FARIDABAD
₹96,000
Yes
2 Mar 2023
18 Jan 2023
3 Feb 2023
18 Jan 2023
1 Feb 2023
18 Jan 2023
Amount
Excavation in trenches not exc 1.5m wide and not exc 1.5m deep for foundation etc or for shafts n.ecx 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and directed by Engineer-in-Charge.
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:4:8 type D-2 (using 40 mm agg. ) in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M & L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (20mm graded stone aggregate) foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
M & L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
M & L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (20mm graded aggregate) in Chajjas complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone/ boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but including ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface incl WPC as per user manual ccomplete all as specified and directed by Engineer-in-Charge. (WPC will be measured and paid separately).
M&L for preparation of old surfaces by removal of existing treatmen and applying two coats of oil bound distemper over a coat of primer on surface of walls through electrical operated grinder etc, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatment and applying two coats of distemper oil emulsion on ceiling over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old surfaces by removal of existing treatment and apply two coats of cement based paint over a coat alkali primer resistance etc complete all as specified and directed by Engineer-in-Charge.
M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth exc 10cm complete all as specified and directed by Engineer-in-Charge.
M&L for one coats of synthetic enamel paint on wooden surfaces of any description over 10cm width or girth including preparation of old surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of surface two coat of white washing on wall including preparation complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), complete all as specified and directed by Engineer-in-Charge.
M&L for Virified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exc 0.36 sqm , in floors, set and jointed in neat cement slurry over 15 mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes and pointed in white or coloured cement to match and incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed by Engineer-in-Charge.
M&L for Virified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exc 0.36 sqm , in dado , skirting etc. set and jointed in neat cement slurry over 10 mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes and pointed in white or coloured cement to match and incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloiured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic colour tiles in vertical surface 300x200x 7 mm thick set andjointed in neat cement slurry and pointed in white or colour cement to match with tiles, 10 mm thick rendering on fair faces of concrete surface of verticle in CM (1:3) finished even and smooth without using extra cement, incl dismantling and rubbish off the primises etc complete all as specified and directed by Engineer-in-Charge. Note : shade & design as approved by EIC/GE.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each and complete all as specified and directed by Engineer-in-Charge.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 sqm each and acomplete all as specified and directed by Engineer-in-Charge.
M&L for anodised aluminium powder coated framed work for door, window / vent (powder coated) aluminium section weighting 0.55kg/RM with one or more rebated incl jointed cleat for fixing etc complete all as specied and directed
M&L for anodised aluminium powder coated door shutter , aluminium section weighting not less than 0.55kg/RM incl necessary 4.8mm th sheet glass ordinary quality / frosted glass or ACP sheet incl joining with cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, lock , 2 x 150mm aluminium handles, 3 x 100mm hinges aluminium, 2 x 150mm Aluminium tower bolts,1xdoor stoper,1xHydralic door closer with each shutter any type incl taking down complete all as specified and directed by Engineer-in-Charge.
M&L for anodised aluminium powder coated window and ventilator shutters, aluminium section weighting not less than 0.55kg/RM incl necessary 4.8mm th sheet glass ordinary quality glass/ frosted incl joining with cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, lock , 2 x 150mm aluminium handles, 3 x 100mm hinges aluminium, 2 x 150mm Aluminium tower bolts complete all as specified and directed by Engineer-in-Charge.
M&L for aluminium Anodized powder coated fixed frame of partiton or fixed window / ventilator , aluminium section weighting not less than 0.55kg/RM incl 4.8mm thick sheet glass oridinary quality ' frosted glass or ACP sheet joining with rubber beading , aluminium snap beading complete all as specified and directed by Engineer-in-Charge.
S&F aluminium wire guard mesh of 4mm nominal dia of wire and average width of aperture 75 - 85mm and fixed with aluminium frame / staples complete all as specified and directed by Engineer-in-Charge.
M&L for 4.8 mm thick float glass ordinary quality' frosted glass and glazing with aluminum beeding and gasket to aluminum framework in square exc 0.50 sqm in each pane in repair complete all as specified and directed by Engineer-in-Charge.
M&L in repair for PVC hollow wall panelling 7 to 8mm thick any colour/design approved by engr-in-charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed by Engineer-in-Charge.
S & F for Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed by Engineer-in-Charge.
S & F for 3mm thick figured glass, pin headed type and glazing with oil putty in Square n. exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S&F 30mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed by Engineer-in-Charge.
S & F dor plain gypsum board panel 12.5mm thick on ceiling with and incl necessary GI frame used with ' T ' or any section accessories etc of galvanized steel all as per manufacturer design conforming to IS-2095 and 2542(1981) the weight of the board shall be not less than 7 kg per sqm incl dismantling of walls and ceiling board any type and two coat of OBD over a coat of putty complete all as specified and directed by Engineer-in-Charge.
S&F in repair for Vitreous China wash basin (Pedestal pattern), White, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed by Engineer-in-Charge.
S& F for Brass CP mixer for mixing hot & cold water screwed down for 15 mm dia complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed by Engineer-in-Charge.
M&L for Chiken wire mesh of size 12.5 mm and wire dia 0.51 mm (24 SWG) hexagonal construction, stretched firmly for roof treatment, complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) for roof pedding, finish even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge
M&L for Making benching with PCC (1:2:4) type B0 using WPC along side wall adjoining to roof in concave shape complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought Iron or mild steel work of any description not otherwise provided for wind tie complete all as specified and directed by Engineer-in-Charge.
S & F for rolled sections as in main and cross beams, hip and jack rafters,truss, purlins where connected to common rafters and running rails, cleat or other connecting plates cutting, welding including Nut Bolts, Fe 410-W(Gde -E-250) quality A complete all as specified and directed by Engineer-in-Charge.
All as per item No 40 above, here-in-before but fixing only complete all as specified and directed by Engineer-in-Charge.
S&F for painted galvaume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S&F painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed by Engineer-in-Charge.
M & L for viterous china squating pan of (Orrissa Pattern) size 580x440 mm white with 'P' or 'S' trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe) fixed in repair including lime concrete bedding as required set complete all as specified and directed by Engineer-in-Charge.
S&F for Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed by Engineer-in-Charge.
S&F for 32 mm dia Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm?45gms/ 40mm-60 gms)complete all as specified and directed by Engineer-in-Charge.
S&F for 32 mm dia Waste coupling of PTMT (half or full threaded) suitable for urinal . (Minimum weight 32mm?45gms)complete all as specified and directed by Engineer-in-Charge.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
S&F for health faucet (ABS body) mils steel chromium plated suitable for 15mm dia pipe with 1.25 mtr along flexible tube and ABS wall hook incl making connection and fixed in position complete all as specified and directed by Engineer-in-Charge.
S&F for liquid soap container of PTMT fixed with and incl CP brass screws and wooden/plastic cleats complete all as specified and directed by Engineer-in-Charge.
S&F for Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/40mm-270 gms), complete all as specified and directed by Engineer-in-Charge.
S&F for Towel ring brass chromium plated, fixed with brass screws and plugs, complete all as specified and directed by Engineer-in-Charge.
S & F solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube incl taking down old frame any type complete all as specified and directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be convered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and raials with suitabale PVC sheet beading, and jointed together with solvant cement, fixing in the frame at side as per specification and drawing incl taking down old shutter & 3Nos- 100mm Aluminium hinges for each shutter complete all as specified and directed by Engineer-in-Charge.
S & F for Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed by Engineer-in-Charge.
S&F for Vitreous China wash down water closet pan (pedestal pattern) with trap, white (excluding fixing bolts, flushing cistern and flush down pipe) incl connection to drain and flushing pipe complete all as specified and directed by Engineer-in-Charge.
S&F PVC flushing cistem low level white with all accessories of 10 ltrs capacity incl flushing pipe, brackets complete all as specified and directed by Engineer-in-Charge.
S & F vitreous china urinals, half stall type (635x450mm) , complete including providing and fixing , bedding urinal against wall in cement mortar 1:2 , pointing around urinal back in cement , grating and union for discharge pipe, (Exclusive of fixing supply pipe to flushing cistern, trap & waste pipe all as specified and approved by Enger-in-Charge.
S&F for Curverbshape urinal partition with frosted glass 8mm thk size 900x450 mm. complete allas specified and dir by Engr in Charge.Jaquar cat part No-JSE-CHR-810UC450X
S&F for Vitreous China wash basin , White, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed by Engineer-in-Charge.
S& F for swan neck pillar cock fancy type chromium plated screw with iron pipe incl all fittings in repairs complete all as specified and directed by Engineer-in-Charge.
S&F CP jet for EWC along with pvc connection complete all as specified and directed by Engineer-in-Charge.
S&F for Toilet paper holder,stainless steel, fixed with and including chromium plated brass screws and and wooden/plastic cleats on walls, complete all as specified and directed by Engineer-in-Charge.. Make: Jaquar Cat Part No. AKP 35753PS or equivalent.
S&F Tublar towel rail 20 mm dia, D type, 60cm long between flanges of brass chromium plated fixed with and incl chromium plated brass screws and wooden/plastic cleats complete all as specified and directed by Engineer-in-Charge.
S & F for 20 mm dia of pipe Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F for rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 500 ltr capacity, hoisted and fixed in any position including 20 mm dia float valve with aluminium fitting, complete all as specified and directed by Engineer-in-Charge.
S&F for 32/40 mm dia PVC waste pipe for WHB/sink, complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5m wide and not exc 1.5m deep for foundation etc or for shafts n.ecx 10 Sqm on plan and n.exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:4:8 type D-2 (using 40 mm agg. ) in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L Reinforced cement concrete M-25 using 20mm graded aggregates in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
All as per item No 74 above but in columns complete all as specified and directed by Engineer-in-Charge.
All as per item No 74 above but in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.
All as per item No 74 above but in Chajjas complete all as specified and directed by Engineer-in-Charge.
All as per item No 74 above but in Slabs supported on walls, beams and columns in floors, roofs, landings, balxonies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
M&L Form work to sides of rough finished flat surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engr-in-charge.
M&L Form work to sides of rough finished square, rectaungular or polygonal surfaces of of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engr-in-charge.
M&L Formwork to sides and soffit of rough finished flat surfaces of soffits of floor or roof beams, beam haunch- ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed by Engr-in-charge.
M&L Form work to rough finished flat surfaces of chullah hoods, chajjas, troughs and similar items in- cluding edges complete all as specified and directed by Engr-in-charge.
M&L Form work to rough finished flat surfaces of soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)complete all as specified and directed by Engr-in-charge.
M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with the mild steel wire (annealed) not less than 0.9mm dia or securing with clips and complete all as specified and directed by Engineer-in-Charge.
All as per item No 84 above but 6 to 8 mm dia and over and including in stirrups, spacers and binders and complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directed by Engineer-in-Charge. (WPC will be measured and paid separately).
Supply only liquid WPC complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying two coats of oil bound distemper on wall over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance and complete all as specified and directed by Engineer-in-Charge.
M & L three coat of white washing on new surface of ceiling including preparation complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick PCC 1:4:8 type D-2 (using 40 mm agg. ) in sub base of flooring and complete all as specified and directed by Engineer-in-Charge.
M & L for 100 mm thick PCC 1:3:6 type C-2 (using 40 mm agg. ) as in plinth protection / path/ any paved area complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloiured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors etc complete all as specified and directed by Engineer-in-Charge.
M & L for glazed ceramic coloured tiles 300x450 mmx7mm thick in vertical surfaces such as skirting and dados, set and jointed in neat cement slurry and pointed in coloured cement to match and incl 10mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for box type steel window 1.25 mm thick made of ERW tube P-Section of size 60 x 25 mm double rebated outer frame comprise of glazed skeleton shutter(two gauged shutters and two glazed shutter) of ERW tube P-Section size 50 x 20 mm and 1mm thick one/two Nos openable leaf consisting of two Nos sash bar of T-Section 20x3mm welded to frame with one No Vertical mullion of ERW box type T-Section of size 60 x 25 mm and 1.25 mm thick and FI 2 mm thick welded / screwed to frame for fixing of glass including fittings and fixture like Handle, Tower Bolt, stopper, cleat, pintal hinges, hold fast etc. (i) Hold Fast, 150mm long of 120mm x 3 mm made to shape -04 Nos per window. (ii) Handle of Z sec 20mm x 25mm, 100 mm long -1 No per leaf (iii) MS Tower bolt 150mm long - 2 No per leaf (iv) Z Sec 20mm x 25 mm, 100 mm long stopper - 1 No per leaf (v) Cleat 55 mm long of hollow square 15mm x 20mm x.63mm welded to hinge -1 No per leaf. (vi) MS Pintal hinges of size 75mm x 12mm - 2 Nos per leaf . (vii) 8 mm square guard bar, 10 cm centre to centre. (viii) 40x6 mm flat iron all around for joint of both frame. (ix) stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples & 3mm thick, sheet glass ordinary quality and glazing with oil putty .(x) Two coat of synthetic enamel paint to MS window and guard bar , Incl taking down old steel / wooden window and making good dismantled portion with PCC 1:2:4 type B0 incl hold fast PCC (four No’s for Each window) & around required plaster in CM 1:4 and match with existing finishing complete all as specified and directed by Engineer-in-Charge.
M&L for pressed steel frames of size 125mmx60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets including necessary fixing lugs, butt hinges (100mm medium weight-03 Nos), lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and making good the existing surface in cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge.
S&F for 35mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed by Engineer-in-Charge.
S&F for 2nd class H.W. glazed and skelton door shutters 35mm thick, open rebated and prepared to received glass/gauge etc (without sash bars) edges of framing plain, chamfered or rounded and mitred , beads for securing glass etc the size of member of shutter as specified in SSR part-I clause 8.23(b) and fitted to chowkahts incl stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads etc complete all as specified and directed by Engineer-in-Charge.
S & F for Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed by Engineer-in-Charge.
S & F for 3mm thick sheet glass ordinary quality glazing with oil putty in square n exc 0.5 sqm quality or description from steel frame and complete all as specified and directed by Engineer-in-Charge.
S & F for mild steel framed work as in grill, guard bars etc with ends of bars/FI shoulders and or riveted or forged in to spikes, framed guard bar and similar works confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
S & F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads complete all as specified and directed by Engineer-in-Charge.
S&F for MS butt hinges, medium weight, cold rolled mild steel 100mm long (ISI Marked) with welded or complete all as specified and directed by Engineer-in-Charge.
S&F for aluminum anodized barrel tower bolts of extruded section 150mm long (ISI Marked) complete all as specified and directed by Engineer-in-Charge.
S&F for aluminum handles cast type anodized 200mm long (ISI Marked) complete all as specified and directed by Engineer-in-Charge.
S&F for 250mm long aluminium alloy, anodised, sliding door bolt of 16mm dia with hasp, staple (bolt type) and fixing clips of sheet, extruded sections and fixing bolts and sliding bolts of extruded sections complete all as specified and directed by Engineer-in-Charge.
S&F in repair, 150 mm ordinay rat tail rod pattern springs incl roller and rabber plate fixed to chowkhats in repairs incl necessary welding if reqd. complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of synthetic enamel paint over a coat of pink primer on wooden new surfaces of any description over 10cm width or girth incl preparation of new surfaces complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete all as specified and directed by Engineer-in-Charge.
All as per item No 114 above but laid in trench or in floor complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC Gully Trap setting / jointed with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC bends/junction any radius complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloiured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling/demolition and rubbish off the primises etc complete all as specified and directed by Engineer-in-Charge.
M & L for glazed ceramic coloured tiles 300x450 mmx7mm thick in vertical surfaces such as skirting and dados, set and jointed in neat cement slurry and pointed in coloured cement to match and incl 10mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stainless steel sink without drainboard, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair 40 mm dia Waste coupling of PTMT (half or full threaded) complete all as specified and directed by Engineer-in-Charge.
M & L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
M&L for Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bends in walls, horizontal or sloping and similier work exc 10 cm nut n exc 20 cm wide complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick Work or concrete surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying two coats of oil bound distemper on ceilloing over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for Granite 18-20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding ,rounding of edgeing and dismantling complete all as specified and directed by Engineer-in-Charge.
S & F Bib tap CP fancy type long body 15 mm bore with will crutch or buttewrfly handle screwed down screwed to iron pipe complete with all fittings complete all as specified and directed by Engineer-in-Charge.
S & F for sink mixer with regular spout wall mounted with connectings legs & wall flanges and incl all necessary fittings complete all as specified and directed by Engineer-in-Charge.
S & F Stop cock /angle CP fancy type 15 mm bore screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for Unions complete all as specified and directed by Engineer-in-Charge.
S & F Stop cock concealed long shank chromium plated fancy type 15 mm bore screwed down high pressure with crutch or butter fly handle complete all as specified and directed by Engineer-in-Charge.
S&F Tublar towel rail 20 mm dia, D type, 60cm long between flanges of brass chromium plated fixed with and incl chromium plated brass screws and wooden/plastic cleats complete all as specified and directed by Engineer-in-Charge.
S&F Soap dish, chromium plated fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
S&F for PVC connections 60cm long superior quality with PTMT nut on both side complete all as specified and directed by Engineer-in-Charge.
S&F for GI tubing 15mm bore medium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required complete all as specified and directed by Engineer-in-Charge.
S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F for PVC floor trap 100mm, with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete unreinforced in ground floors and paving n. exc 15 cm thickness below or above gound level , concrete debris and rubbish to a distance n exc 100m complete all as specified and directed by Engineer-in-Charge.
M&L for Surface excavation n.exc 30 cm deep and and avg 15 cm deep and getting out soft and loose soil complete all as specified and directed by Engineer-in-Charge.
M&L for Surface excavation n.exc 30 cm deep and and avg 15 cm deep and getting out hard and dense soil complete all as specified and directed by Engineer-in-Charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, with grey cement, pigment complete all as specified and directed by Engineer-in-Charge.
M & L broken bricks hard core of gauge n.exc. 63mm, deposited, spread and leveled in layers n.exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching and all other similar works including necessary formwork complete all as specified and directed by Engineer-in-Charge.
M&L 15 mm thick rendering in cement mortar 1:3 in side and out side wall of manhole,septic tank etc of brick work/concrete surfaces finished even and smooth ( With out using extra cement) complete all as specified and directed by Engineer-in-Charge.
M&L type B1 1:2:4 (20mm graded aggregate) providing RCC precast cement concrete as in cover slab for man hole and similar article with plain face and set in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced concrete pipe Class NP-3, 150mm dia with coller laid jointed with CM 1:3 complete all as specified and directed by Engineer-in-Charge.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe internal dia of 150 mm pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed by Engr-in-charge.
M&L PCC 1:3:6 type C2 as in concrete bed to 150 mm bore drain pipe and over incl packing under haunching against the sides of pipes after pipe laid and tested complete all as specified and directed by Engineer-in-Charge.
M&L for broken bricks hard core gauge n.exc 63mm deposited, spred and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C2 using 40 mm graded aggr as in surface channels and drains complete all as specified and directed by Engineer-in-Charge.
M&L brick work with sub class 'B' bricks, straight or curgved in cm 1:4 straight or cuved on plan to exc 6m mean radius complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching and all other similar works including necessary formwork complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 153 above Add or deduct for each 25 cm girth or part thereof over or under 30 cm complete all as specified and directed by Engineer-in-Charge.
M&L for one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description n. exceeding 1 square metre each complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exceeding 1 square metre but n. exc 2 sqm each complete all as specified and directed by Engineer-in-Charge.
Refixing in same opening of shutters of any description exceeding 1 square metre but n. exc 2 Sqm each incl easing, adjusting and renewal of screws complete all as specified and directed by Engineer-in-Charge.
M&L Anodised aluminium powder coated window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer-in-Charge.
M&L for 12mm thick Toughed Glass as in hinged doors,partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed by Engineer-in-Charge.
S&F of door closer hydraulically regulated design No 2 etc complete all as specified and directed by Engineer-in-Charge.
S&F of aluminium handles 150 mm long for aluminium door and window shutter etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair mild steel, chromium plated curtain rod cut to size 20mm dia with holder/bracket, stops, rollers etc, complete fixed in repairs complete all as specified and directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed by Engineer-in-Charge.
M & L cement concrete (1:3:6) type C1 (20mm graded stone Agg.) as in embedding of angle iron post complete all as specified and directed by Engineer-in-Charge.
S&F in repair grating round 100 mm size of CP complete all as specified and directed by Engineer-in-Charge.
S&F for rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 1000 ltr capacity, hoisted and fixed repair in position including 20 mm dia float valve with aluminium fitting, dismantling existing water tank complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F for 20mm dia Nipple suitable for HDPE water tank.(Minimum weight 15mm-38gms/20mm 45gms /25mm- 65gms) complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia Unions. brass to connect iron to polyethylene and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm dia Unions. brass to connect iron to polyethylene and fixed complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or removed to store complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints,laid in trenches or in floors etc complete incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc complete incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC bends/junction with access door any radius complete all as specified and directed by Engineer-in-Charge. .
S&F for 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm dia PVC (SWR) multi floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F for 75 mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed by Engineer-in-Charge.
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface incl WPC as per user manual complete all as specified and directed by Engineer-in-Charge. (WPC will be measured and paid separately).
M & L three coat of white washing on new surface of wall including preparation complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying two coats of plastic emultion paint in internal wall surface on wall over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying two coats of plastic emultion paint on ceiling over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatment and applying two coats of plastic emultion paint over a coat of primer on surface of walls through electrical operated grinder etc, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatment and applying two coats of plastic emultion paint on ceiling over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for applying one coat of Acrylic smooth exterior emulsion paint on walls, pillars cornices etc surfaces by spray gun machine incl by complete removal of existing sureface & filling necessary putty where required as in pathces or nail holes obtain smooth finish using sand paper and matching the existing surface complete all as specified and directed by Engineer-in-Charge.
M&L for applying two coat of Acrylic smooth exterior emulsion paint on walls, pillars cornices etc surfaces by spray gun machine incl by complete removal of existing sureface & filling necessary putty where required as in pathces or nail holes obtain smooth finish using sand paper and matching the existing surface complete all as specified and directed by Engineer-in-Charge.
M&L for providing RCC nominal mix 1:2:4 incl necessary formwork and providing plaster in cement mortar 1:3 and two coats of finishes over a coat of primer for RCC projected portion as in facias, fins upto a height of 30 cm facia etc incl demolition of existing and providing TMT bars if reqd complete all as specified and directed by Engineer-in-Charge. (Note length of fins, facias shall be measured irrespective of any thickness and height).
M&L for reparing of RCC projection, chajja, roof facia, celling by scrapping, cutting, derusting and cleaning exposed reinforcement surfaces of damaged loose RCC surface and applying neat cement slurry @ 3 kg/Sqm and filling the surface with cement plaster 1:3 one or two layer as reqd or PCC 1:2:4 as directed by Engr-in-Charge with or without facia and smooth finished and smotth edges incl two coats of finished to match with the existing surface at any height and in any situation including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L in repair for PVC hollow wall panelling 7 to 8mm thick any colour/design approved by engr-in-charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site incl dismantling of panelling complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plaster surface & apply two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatmen and applying one coat of oil emulsion distemper over a coat of primer on surface of walls through electrical operated grinder etc, complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old surfaces by removal of existing treatment and apply one coat of cement based paint over a coat alkali primer resistance etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatment and applying one coat of distemper oil emulsion on ceiling over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old surfaces and applying one coat of white washing on wall complete all as specified and directed by Engineer-in-Charge.
M&L for 12mm thick Toughed Glass as in hinged/sliding doors,partitions automatic doors and similar work including cutting to shape, drilling holes, chanels for sliding door, SS handles etc and other connecting necessary items required complete all as specified and directed by Engineer-in-Charge.
M&L for providing and fixing 10 mm thick plaster of paris ceiling (Gypsum anhydrous) of approved design/pattern to flat surfaces incl all necessary MS frame work, 12 mm thick board and fittings as per standard practice and as per manufacturer's instrs reinforced with GI wire mesh incl dismantling of walls and ceiling board any type complete all as specified and directed by Engineer-in-Charge.
M&L in repair of one piece closet with bowl for coupled WC with PP soft seat cover , hinges fixing accessories and accessories set of size 360x640x680 mm, strap 220 mm withsyphonic flushing cistern with necessary fittings complete all as specified and directed by Engineer-in-Charge. Make Jaquar Cat Part No- SLS-WHT-6851S220PP/Kohler/Equalent Make.
S&F in repair wash hand basin table top of size 600x400x175 mm vitrous China including , waste coupling & PVC waste pipe of 32 mm dia etc.complete all as specified and directed by Engineer-in-Charge. Make Jaquar cat part No - SLS-WHT-6601/Kohler or equalent make.
S&F in repair Toilet paper holder of brass, chromium plated fixed to walls with chromium plated (CP) brass screws complete all as specified and directed by Engineer-in-Charge. Make Jaquar cat part No - AHS-CHR-1553.
S&F for CP brass Centre hole mixer without pop up waste system with 450 mm long braided hoses, 20mm cartridge size for mixing hot and cold water screwed down for iron pipe for WHB, in repairs complete all as specified and directed by Engineer-in-Charge. Make : Jaquar Florentine (FLR-CHR-5167NB)
S&F for cabinet PTMT of 400mm x 500 mm with megnetic looking arrangements fixed with and inclduling chromiplated brass screws and PVC rawl plugs complete all as specified and directed by Engineer-in-Charge.
S & F for vitrious china sensor urinals size-485x300x740 mm Make- Jaquar cat part No- URS-WHT-13255 or equvelent including all necessary fittings etc complete all as specified and directed.
S & F for 8 mm thick toughend frosted glass urinal partitions Make- Jaquar cat part No-1810-US or equvelent including all necessary stainless steel fitting etc complete all as specified and directed by Engineer-in-Charge.
S&F for Soap tray brass chromium plated and fixed to plugs on wall with brass screws, complete all as specified and directed by Engineer-in-Charge. Make: Jaquar Cat Part No. ACN 1131N or equivalent .
S&F for Towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed by Engineer-in-Charge. Make: Jaquar Cat Part No.ACN CHR 1111SM or equivalent.
S&F for Towel ring brass chromium plated, fixed with brass screws and plugs, complete all as specified and directed by Engineer-in-Charge. Make: Jaquar Cat Part No. ACN CHR 1121N or equivalent.
S&F stainless steel pegset of six suitable size of length complete etc complete all as specified and directed by Engineer-in-Charge.
M&L for 25mm dia Decorative/ fancy type stainless steel curtain rod with brackets and knobs at both ends as per site requirement including taking down old existing PVC/steel conduit pipes with accessories complete all as specified and directed by Engineer-in-Charge. Note : The cost of brackets and knobs is deemed to be including in the quoted rate. Nothing extra shall be paid on this account.
M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and including concealed PVC Conduit medium grade, ISI marked 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet (Make: Hylam) for provision of switches/regulators as per specified SSR complete all as specified and directed by Engineer-in-Charge. NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls.
All as per item No 217 above but 5 Amp socket outlet, independent complete all as specified and directed by Engineer-in-Charge.
All as per item No 217 above but on the same board complete all as specified and directed by Engineer-in-Charge.
All as per item No 217 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of switch piano type 5 amp SP one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of switch 15 Amps SP one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of socket outlet 3 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of socket outlet 2-in-1, 3 pin 5 amps and 15 amps flush type complete all as specified and directed by Engineer-in-Charge.
S/fix ceiling rose,3 phase/PVC/Polycarbonate,isolated body after dismantling old one complete all as specified and directed by Engineer-in-Charge.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 4 sqmm cable alongwith one run of 2 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
M&L for earthing with galvanised steel plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25mtr deep from ground level) surrounded from all directions with charcoal dust, salt and edge of earth plate not less than 1.5 mtr below ground level connected to galvanised iron strip 32mmx6mm earth lead by means of nuts, bolts and washers incl excavation and earth work PCC chamber and RCC cover of 1:2:4 type B-1 using XPM weighing not less than 4 Kg/Sqmm using 20mm graded stone aggregate for coping/under covers, 20mm size GI pipe light grade for watering funnel wire mesh etc, complete all as specified and directed by Engineer-in-Charge and shown in electrical plate No-03 of SSR Part-I.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge.
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louvers all as specified and directed by Engineer-in-Charge
S/Fix in replacement MCB DB SPN 8 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc completed after dismantling old one complete all as specified and directed by Engineer-in-Charge.
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm (1”) dia complete all as specified and directed by Engineer-in-Charge.
M&L for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 m wide in depth for laying of cable or pipe for protection of cables or fixing of poles struts or stays and getting out in hard dense soil including triming the side and forming bottom surface to required level complete all as specified and directed by Engineer-in-Charge.
Returning , filling in approved excavated , soil in including spreading ,leveling , watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed by Engineer-in-Charge.
M & Labour for sand cushioning with a layer of sand 80mm thick consolidated before laying of cable and 150mm thick consolidated after laying of cable in trenches ducts for electric cable protection including consolidation complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated soil to a distance n exc 50m and deposited where directed at a level n exc 1.5 m above the starting points complete all as specified and directed by Engineer-in-Charge.
M&L for Burnt clay fly ash building bricks designation 75(Kg/cm2) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge. (a) SP 5 To 32 Amp
SPN 32 Amp complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engineer-in-Charge.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclosures DB Double door Verticle distribution type, 04 way, TPN DB , IP43, 415V & including4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed by Engineer-in-Charge.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix pipe galvanized, “Medium class”, including fittings 15 mm (1/2”) dia all as specified and as directed by Engineer-in-Charge.
M&L for Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) all as specified and as directed by Engineer-in-Charge.
Supply and fix PVC connections 15mm size with PTMT nuts of length 300mm all as specified and as directed by Engineer-in-Charge.
Supply and fix Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and as directed by Engineer-in-Charge.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amps MCB all as specified and directed by Engineer-in-Charge
M&L for Design, development, supply commissioning and testing EHCC certified ground tubular effective chemical earthing system in hard soil /rock etc (CPRI tested for 15 KA current capacity for LT Iine) highly anticorrosive long life electrode with and including adequate protective coating to withstand servere weather conditions in the earth pit of the standard size comprising of 40mm x 3m Long Copper rod as primary conductor and hollow copper tube of 80mm x 3m long as secondary conductor to install with suitable connecting terminal confirming of IS 3043 : 1987 specification, highly conductive packing material to be filled in earth pits for providing uniform, low resistivity anticorrosive, hygroscopic medium around the earth system for improving the efficiency of current dissipation with crystalline conductive mixture (CCM) 20 Kg per bag (3 bag per kit) minimum or sufficient quanitities required as per site complete including RCC earthing pit cover , material and labour complete all as specified and directed by Engineer-in-Charge. Note :- Excavation / drilling hole in hard soil/rock is included in the rate quoted.
M&l tubing light grade galvanized iron to be embeded in PCC block fitting complete with 40 mm bore all as specified and directed by Engineer-in-Charge
M&L for Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-Charge
Supply and fix Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed by Engineer-in-Charge
M & L for test point terminal block made of gun metal or phosphorus bronze size 75X75X25 mm drilled and screwed including 3 no's 8 mm dia 25 mm long hex. head screw complete all as specified and directed by Engineer-in-Charge.
M&L Pre-cast cement concrete block masonry with solid blocks PCC Type B1 1:2:4 ( 20 mm graded aggregate ) , exc. 10 cm in width and setting in mortar, complete all as specified and directed by Engineer-in-Charge
Supply and install hi wall split units indoor/outdoor with inverter Power Supply [V/Hz/Ph] 230 / 50 / 1 Phase complete with cordless remote control unit and with in built air ioniser , blue fins and Plasma filter for better indoor air quality with Twin Rotary compressor - BLDC, Copper Condenser Coil, Variable speed compressor which adjusts power depending on heat load energy efficient and lowest-noise operation Capacity: 2 Ton Energy Rating: 5 Star rated ISEER not less than 5.5 Refrigerant gas: R-134a Environment friendly - no ozone depletion potential & low global warming potential with suitable MS mounting stands factory made for indoor and outdoor unit including connecting Copper tubings , drain pipe, including extra refrigerant , electric cable , copper inlet and outlet tubing as required at site all as specified and directed by Engineer-in-Charge.
Supply and install Automatic boost/buck transformer for low and high voltage correction, equipped with electronic transistored relay suitable for correction on single phase 50 cycles AC supply complete with voltmeter and designed for input voltage 160 to 280 V and output voltage stabilized 230V with accuracy of + 5% and of capacity 5 KVA wall mounted all as specified and directed by Engineer-in-Charge. Make V Gaurd/ Microtec / Luminous
Single pole and neutral enclosure with a two pin and earth Plug and socket complete including one single pole MCB 20 - 32 Amp SP MCB B Curve 10 KA all as specified and directed by Engineer-in-Charge.
M&L submain wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2.5 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 4 sqmm cable alongwith one run of 2.5 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).Make of Cable : Finolex/Polycab/Havells
Supply and fix complete UPS system including battery 2 Nos of 180 AH, 30 min back up single phase AC input 160 to 260 V and out put 230 ± 1% of capacity 2KVA suitable to be connected with HT VCB Panel including connecting connecting cables , thimbles , links, battery UPS stand etc all as specified and directed by Engineer-in-Charge.
Supply and installation of 16M high mast shaft in two sections suitable for 47 m/s wind speed, with Latching type head frame, winch mounting bracket, luminaries carriage suitable for installation of 8nos of 150w Flood light luminaries in symmetrical arrangement comprising of following :- HIGH MAST SYSTEM Height of mast : 16 Meter, No. of sections : Two, Material construction : S 355 grade as per BS- Base dia. and top diameter (A/F) :, Plate thickness : Top : 200 mm, Bottom : 460 mm Top : 3 mm, Bottom : 4mm Cross section of Mast : 20 side polygon. Standard for of galvanisation : As per BS EN ISO 1461 Size of opening and door at base : 1200 x 250 mm, Diameter of base plate : 670 mm, Thickness of base plate : 25 mm, Lightning protection finial : G.I single spike Max.wind speed : As per IS : 875 (Part - III Number of foundation bolts : 08 nos, PCD of foundation bolts : 590 mm, Type / diameter / length of foundation bolts : TS 600 / 30 mm dia / 85 LUMINAIRES CARRIAGE Material of construction : 40 NB (50mm) ERW Class Raising lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial. TRAILING CABLE Conductor : Copper, 5 core, 2.5 sqm, Insulation : EPR insulated PCP sheath, No. of circuits per mast : One no. cable per mast WINCH / POWER TOOL Type / SWL of winch : Double drum, SWL 750 K, Method of operation : Integral Motor, Motor capacity : 1 HP, No of speeds : 6 Pole, Single speed
All as per item No 264 above :- STAINLESS STEEL WIRE ROPE Grade / construction : AISI 316, 7/19 constructi, Number of ropes : 2/3 Wire Rope Diameter (mm) : 6 mm, Breaking load capacity : 2350 kg x 2 Foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template. LED type single dome aviation obstruction light. Flood light luminaire 150 watt 230 V AC outdoor type with poly carbonate optics die-cast housing, IP66 ingress protection, 4KV in -built and 10 KV external surge protection. Efficacy 110 Im/W complete suitable for input voltage140 Volt to 280 Volt. The LED flood light shall have power factor more than 0.95 , 50000 L70,CRI>70,CCT 5665K ± 355K, THD <10%,IP 66,IK 07, Operating Tempreature -10 degree Celcius to 50 degree Celcius ,Beam Angle 70degree complete all as specified and directed by Engineer-in-Charge.
All as per item No 264 above :- Note:- The quoted rate is deemed to include the cost of aviation obstruction light, Lightening arrestor spike , required suitable size of RCC foundation for the high mast pole and 4 mm GI wire for earthing connection from LA spikes at the top of the pole to the earthing point. (i) Erection of the high Mast with the help of suitable equipments and wiring of luminaires with all wiring materials and labor. (ii) Installation of control panel on suitable foundation including material labour. (iii) Detailed specification/ Technical data sheet shall be submitted by contractor before erection of high mast. (iv) High mast must be installed by authorised OEM rep only. (v) provision of switch socket/ starter point with plugtop for power trailling cable in included in unit rate. (vi) PCC 1:2:4 type B-1 ( using 20 mm graded aggregate) for coping of poles up to 30 cm above ground including necessary form work , and finishing the surface even and smooth without using extra cement including. (vii) Driver and luminaire shall be of same manufacture
Supply and fix LED Flood light fitting 150 Watt Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for mounting on luminaire arm of high mast fitting highlighting architectural facade and general purpose lighting all as specified and directed by Engineer-in-Charge.
M&L for XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm having 4 core all as specified and directed by Engineer-in-Charge.
M&L for GI Pipe/Tubes 40 mm dia., 'light grad', galvanised, with all fitting laid in trenches for pasisng through XLPE cables of different size all as specified and directed at site by Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip of 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified and directed at site by Engineer-in-Charge or indicated including testing on completion
GAR CONSTRUCTIONS
Akhil Enterprises
Singh Associates
High Tech Metal India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .