| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC C 187 NIRMAN VIHAR DELHI 92 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹27.2 L+₹6.4 L (31.0%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹28.0 L+₹7.2 L (34.6%)Rejected-Finance 01 TIWARI BAZAAR GONDA ROAD TIWARI BAZAAR GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹28.4 L+₹7.6 L (36.6%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹28.8 L+₹8.0 L (38.4%)Rejected-Finance 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L5 | Rejected-Finance Not being lowest tender |
Tender Value
₹20.2 L
EMD Value
₹40,400
Closing Date
21 Jan 2022, 6:00 pmClosed
GE AF TA
GE AF TA GWALIOR-474020
REPAIR/MAINT OF FLAME PROOF WIRING/FITTING IN SHELTERS/HANGARS AT AF STN GWALIOR
2021_MES_494767_2
8900/1362/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF TA GWALIOR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF TA GWALIOR
₹40,400
Yes
9 Mar 2022
7 Jan 2022
29 Jan 2022
7 Jan 2022
21 Jan 2022
14 Jan 2022
Amount
Taking down carefully existing unserviceable flame proof point wiring of any description & in any position with and including existing conduit fixed on surface with and including existing junction boxes in between the point wiring complete, including making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed. NOTE: (i) Old existing junction boxes obtained in serviceable condition from taking down of point wiring shall be re-used in the work. (ii) Taking down / replacement of existing fittings like switches/sockets / switch fuses / tube light fittings etc. if any, shall be measured and paid for separately under appropriate item of Schedule `A'/BOQ
Taking down carefully existing unserviceable flame proof point wiring of any description & in any position from existing conduits fixed on surface or cancealed including accessaries & fixtures etc and making good the distrubed surface of walls, floors, ceiling etc to match with the existing surface complete all as specified and directed NOTE: (i) Taking down / replacement of existing fittings like switches/sockets / switch fuses / tube light fitting etc. if any, shall be measured and paid for separately under appropriate item of Schedule `A'/BOQ.
Material and labour for flame proof point wiring for one light point or one socket point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLSH PVC insulated & unsheathed cable, 1100 volts grade in and including stove enameled black, rigid steel conduits of size not less than 20 mm dia (Medium grade) fixed on surface of walls/ceilings as directed with all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core FRLSH, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly / fittings etc. complete all as specified and directed NOTE : (i) Old junction boxes retrieved in serviceable conditions shall be re-used in the work. However, additional junction boxes, if any required, for making new point wiring other than the quantity of junction boxes retrieved from taking down of point wiring, shall be measured and paid for separately as ‘’supply only’’ under appropriate item of Schedule `A'/BOQ but fixing element of any type of junction boxes new or old is deemed to be included in the rates quoted by the contractor for the above item. (ii) Wiring shall be terminated and connected to the relevant switch / controlling switch gear and relevant fittings / sockets all as directed and controlling switch / fittings shall be measured and paid for separately under appropriate item of Schedule `A'/BOQ.
All as per item No 3 here-in-before but point wiring with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, FRLSH PVC insulated & unsheathed cable for 16 A Flame proof Switch and socket
Material and labour for flame proof point wiring for one light point or one socket point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLSH PVC insulated & unsheathed cable, 1100 volts grade in existing conduit fixed on surface of walls/ceilings as directed and using 1.5 Sqmm (nominal area) stranded copper conductor single core FRLSH, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly / fittings etc. complete all as specified and directed NOTE : (i) Point wiring shall be executed with using existing conduits and junction boxes but contractor’s quoted rates for the above item is deemed to include the cost of fixing the existing conduits and junction boxes in position properly as per site requirement and as directed by the Engineer-in-Charge. (ii) Wiring shall be terminated and connected to the relevant switch / controlling switch gear and relevant fittings / sockets all as directed and controlling switch / fittings shall be measured and paid for separately under appropriate item of Schedule `A'/BOQ.
All as per item No 5 here-in-before but point wiring with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, FRLSH PVC insulated & unsheathed cable for 16 A Flame proof Switch and socket complete all as specified and directed.
M&L for sub main wiring in repair using Four single core PVC insulated, FRLSH, stranded copper conductor cable of size 4 Sqmm for sub main wiring, along with one run of 4Sqmm PVC insulated, FRLSH, Stranded copper conductor cable for earth continuity conductor in steeel conduit complete all as specified and directed. Note: Four run of single core PVC cable with one run of earth wire and one run of steel conduit shall be measured as one unit.
All as per item No. 7 here-in-before but using Two single core, 2.5 Sqmm copper conductor cable and without earth continuity conductor. Note: Two run of single core PVC cable and one run of steel conduit together shall be measured as one unit.
All as per item No. 7 here-in-before but using Two single core, 1.5 Sqmm copper conductor cable and without earth continuity conductor. Note: Two run of single core PVC cable and one run of steel conduit together shall be measured as one unit.
Disconnecting and taking down carefully flame proof, weather proof, toggle type switches and making good the disturbed surfaces complete all as specified and directed.
Disconnecting and taking down carefully flame proof DB’s of any size/way and making good the disturbed surfaces complete all as specified and directed.
Disconnecting and taking down carefully flame proof, switch fuse unit of any capacity and making good the disturbed surface complete all as specified and directed.
Disconnecting and taking down carefully flame proof Switch socket of any capacity and making good the disturbed surface complete all as specified and directed.
Supply & fixing flame proof push button 10 Amps in LM 6 metal enclosures, conforming to cat part No PBS / OA /1010-1A of make Sudhir or equivalent model of other make as specified complete all as specified & directed.
Supply & fixing in flameproof switch fuse unit in LM-06 metal enclosures with HRC fuse double pole 16 Amps, Single Phase 240 volts complete all as specified and directed (Make/model – Sudhir cat part No. SF/OA/1011 or equivalent model of other make as specified and directed.
Supply & fixing flameproof switch fuse unit in LM-06 metal enclosures, with HRC fuse triple pole and neutral having current rating of 63 Amps three phase 500 volts complete all as specified and directed. (Make/model – Sudhir cat part No. RCP/215 or equivalent model of other make as specified).
Supplying & fixing flame proof, switch socket & plug combined made of aluminum alloy LM-6 having 2 pole + earth suitable for 250 volts supply and current rating of 16 Amps complete all as specified & directed. (Make/model – Sudhir cat part No. SS/OA/1010 -1 or equivalent model of other make as specified).
Supplying & fixing flame proof, switch socket & plug combined made of aluminum alloy LM-6 having 4 pole + earth suitable for 500 volts supply and current rating of 32 Amps complete all as specified & directed. (Make/model – Sudhir cat part No. SS/187 or equivalent model of other make as specified).
Disconnecting & taking out existing unserviceable socket’s plug of any description and in any position and supplying & fixing new spare plug suitable for existing flame proof, weather proof, switch, socket & plug combined in LM-6 for 2 poles + earth & current rating of 16 Amps complete all as specified and directed. (Make – Sudhir or other make as specified ).
All as per item No 19 here-in-before but plug suitable for 4 pole + earth & current rating of 32 Amps (Make – Sudhir or other make as specified).
Supply & fixing flameproof distribution board 8 way single pole & neutral in LM-6 metal enclosures with and including 01 No MCBs single pole and neutral 40 Amps & 06 Nos MCB single pole 16 Amps `C’ series complete all as specified and directed. (Make : Cat part no MCDB-186 of Sudhir or equivalent model of other make as specified.
Supply & fixing flameproof distribution board 4 way Triple pole & neutral in LM-6 metal enclosures with and including 01 No MCBs tripple pole and neutral 63 Amps & 06 Nos MCB single pole 16 Amps `C’ series complete all as specified and directed. (Make : Cat part no MCDB-186 of Sudhir or equivalent model of other make as specified).
Supply & fixing in replacement flameproof distribution board 4 way Triple pole & neutral in LM-6 metal enclosures with and including 01 No MCCB tripple pole and neutral 100 Amps as Incoming & Out going MCB 63 Amps TPN 415 volts -01 No,MCB DP 32 Amps 240 Volts-01 No and MCB SP 16 Amps 240 Volts -03 Nos complete all as specified and directed. (Make : Cat part no MCDB-186 of Sudhir or equivalent model of other make as specified).
Supply & fixing in replacement FLP Flexiblae metelic Hose conduit M20/3/4ET 300 mm long complete all as specified and directed. (Make : Cat part no FH/199 of Sudhir or equivalent model of other make as specified).
Supply & fixing in replacement FLP Flexiblae metelic Hose conduit M20/3/4ET 500 mm long complete all as specified and directed. (Make : Cat part no FH/199 of Sudhir or equivalent model of other make as specified).
Supply & fixing in replacement FLP Flexiblae metelic Hose conduit M20/3/4ET 1000 mm long complete all as specified and directed. (Make : Cat part no FH/199 of Sudhir or equivalent model of other make as specified).
M & L for checking & repairing flame proof tube lights/flood lights & other flame proof connected work as directed in tech area and repairing of flameprrof lights found unserviceable during checking or as directed by JE/Engr-in-Charge/men on complaint cell including rectification of fault of wirng etc by deploying skilled Electrician, helper with all tools & plants, ladder, gaskets safety arrangements and including providing minor materials like insulation tap and connected material by contractor to make light serviceable complete all as specified and directed. NOTES :- (i) Rate quoted shall deemed to be included for required minor material like insulation tap,rubber gasket and packing materials required for function of box with lugs etc. (ii) Items like Driver for LED and other items other than mentioned above shall be measured and paid separately.
Supply and fixing LED driver 240 V 50 Hz suitable for the existing LED flame proof lights fittings (Make Sudir) for the following watt :-
(a) 75-90 Watt
(b) 120-180 watt
S&F in repair Ultra bright glass 20W LED tube light and high efficiency suited for installation in exsiting flame proof Tube light fitting (T-8) alongwith G3 lamp holders complete all as specified and directed. Make :-Havells Cat part No -CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Philips/Bajaj/Wipro
Supply & fixing flame proof FLP Flood light 60 W LED fittings as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers heat resistant glass complete all as specified and directed.
Supply & fixing flame proof FLP Flood light 70 W LED fittings as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers heat resistant glass complete all as specified and directed.
Supply & fixing flame proof FLP Flood light 90 W LED fittings as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers heat resistant glass complete all as specified and directed.
Supply & fixing flame proof FLP Flood light 120 W LED fittings as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers heat resistant glass complete all as specified and directed.
S&F LED Tube rod 28 W T-5 complete all as specified and directed.
Supply and fixing in distribution board, single pole (SP) MCB 6 to 20 Amps, 240 volts, 50 Hz, AC made from molded self extinguishing thermostat plastic and suitable for ‘ C ‘ curve, 10 KA breaking capacity conforming to IS : 8828 of 1996 including taking down unserviceable MCB complete all as specified and directed.
All as per item No 33 here-in-before but MCB double pole & current rating 6 Amps to 32 Amps
All as per item No 33 here-in-before but MCB four pole & current rating 40 Amps
Supply only flame proof junction box 3 way ¾ “ entry in LM – 6 complete all as specified and directed.
m/s vikash Engineers
M/s A.K. Trading Co.
UNIVERSAL AGENCY
M/s Anupam Construction Co.
M/s Yashika Enterprises
M/s. Ravi and brothers
lodhi builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .