| 1 | L1₹33.9 LAccepted-AOC NEAR RAILWAY STATION UTARLAI BARMER RAJASTHAN PIN 344001 | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹35.1 L+₹29,846.60 (0.86%)Rejected-Finance 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance HIGHEST | |
| 3 | L3₹36.4 L+₹1.6 L (4.48%)Rejected-Finance | L3 | Rejected-Finance HIGHEST | |
| 4 | L4₹36.6 L+₹1.8 L (5.13%)Rejected-Finance | L4 | Rejected-Finance HIGHEST | |
| 5 | L5₹38.4 L+₹3.6 L (10.3%)Rejected-Finance VILL JASSAI DISTRICT BARMER RAJ 344001 | JASSAI | BARMER | RAJASTHAN | 344001 | L5 | Rejected-Finance HIGHEST |
Tender Value
₹41.9 L
EMD Value
₹93,600
Closing Date
1 Jun 2022, 6:00 pmClosed
GE ARMY BARMER
MILITARY ENGINEER SERVICES GARRISON ENGINEER ARMY JALIPA MIL STN POST BOX NO 53 BARMER 344001
PROVN OF SPECIAL REPAIR TO BUILDING NO P153 P 96 AND ESH NO 34 P 37 AT JASAI MIL STN UNDER GE ARMY BARMER
2022_MES_518225_1
8536/E8
Open Tender
Civil Works
Item Rate
180 days
GE ARMY BARMER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY BARMER
₹93,600
2 Aug 2022
13 Apr 2022
2 Jun 2022
13 Apr 2022
1 Jun 2022
16 May 2022
Amount
Taking up or down existing GI Tubing15 mm dia & connections including cleaning for refixing or removal to store all as specified and as directed
Taking up or down existing GI Tubing 20 mm dia & connections including cleaning for refixing or removal to store all as specified and as directed
Taking up or down existing GI Tubing 25 or 32 mm dia & connections including cleaning for refixing or removal to store all as specified and as directed
S&F, 15 mm bore galvanized iron tube medium grade with all fittings such as bends, elbos , socket, reducer and fixed to wall, ceiling or laid in floors.
S&F, 20 mm bore galvanized iron tube medium grade with all fittings such as bends, elbos , socket, reducer and fixed to wall, ceiling or laid in floors.
S&F,25& 32 mm bore galvanized iron tube medium grade with all fittings such as bends, elbos , socket, reducer and fixed to wall, ceiling or laid in floors.
S&F in repair 25mm bore low density polyethylene pipes (LDPE) pressure rating 6 kg/ cm2 of fixed complete to walls, ceiling or laid in trenches
S&F in repair 32mm bore low density polyethylene pipes (LDPE) pressure rating 6 kg/ cm2 of fixed complete to walls, ceiling or laid in trenches
Dismantling of existing water tanks capacity n exc 500 ltr and removing to store
S&F in Repair rotational moulded polethylene water tank of 500 ltrs capacity ( cylindrical vertical with closed top) hoisted and fixed in position all as pacific SSR Part- I
S&F in repair 15 mm dia bib tap,fancy type chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified anddirected.
S&f in repair 15mm bore pillar tap cast copper alloy fancy type with capston heads, chromium plated screwed down high pressure, with or without letters Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipes and fixed all as specified and directed.
S&F in repair 15 mm dia fancy type chromium plated Stop valves, cast copper alloy,screwed down,high pressure,with crutch orbutterfly handle,screwed both ends for iron pipe or for unions and fixed
S&F in repair 15mm bore stop valve cast copper alloy chromium plated fancy type with long shank and cup ( concealed type)high prssure screwed for iron pipe and fixed all as specified.
S&F in repair 15 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe
S&F in repair 15mm bore angle stop valve of PTMT any colour high prssure screwed for iron pipe and fixed all as specified (minimum wt. 90gms).
S&F in repair 20mm ball valve high pressure of PTMT with epoxy coated aluminium rod and high denty plastic ball screwed for iron pipe and fixed (min wt. 210gms).
S&F in repair 32mm dia waste coupling of PTMT (half or full threaded) min wt.32 mm 45 gms/40 mm -60 gms .
S&F in repair grating doom 100 mm dia of PTMT (Min wt 25 gms)
S&F swivel shower rose of PTMT any colour for fixing with 15mm pipe fixed all as specified (minimum wt. 40 gms).
S&F in repair PVC connection 15mm bore length not less than 300 mm long with both ends PTMT nuts complete all as specified.
S&F in repair PVC connection 15mm bore length not less than 450 mm long with both ends PTMT nuts complete all as specified.
S&F in repair Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms)
S&F in repair wash down water closet (Pedestal pattern) white complete
S&F in repair vitreous china squatting pan ORISSA pattern size 580mm x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and directed.
S&F in repair Vitreous China urinals,half stall ,complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S&F in repair vitreous china wash basin white, flat, back, size 550x400 mm excluding tap waste but including brackets and including cutting for and pinioning in ends of brackets but exclusive of supply waste pipe all as specified
S&F seat cover for EWC.
S&F in repair Soap dish, any type, fixed to plugs with chromium plated fancy type brass screws
Supply and fix in repair 10 ltrs PVC valveless syphonic action type flushing cistern low level white , with inlet ball valve, float and handle including bracket with 32 mm dia PVC pipe 600 mm long complete all as specified and as directed.
S & F health faucet with nozzle 30" long PVC coneection pipe and CP brass spary handle complete all as specified and directed.
Taking down cement plaster on brick or stone walls or ceiling etc. including racking out joints,hacking for key, scrubbing down with water etc all as specified and directed.
M&L rendering 10mm thick in CM 1:4 on ceiling surface of concrete or stone slabs, rendering is to be finished even and smooth (without using extra cement) all as specified and directed.
M&L 15mm thick plastering other than fair surface in cement mortar 1:6 finished even and smooth without using extra cement on stone masonry and concrete surface all as specified.
M&L 15mm thick plastering on fair surface in cement mortar 1:6 finished even and smooth without using extra cement on stone masonry and concrete surface all as specified.
M&L for preparing of new plastered / Unplastered surfaces of walls and applying two coats of cement based paint over one coat of primer as camouflage pattern all as specified and directed by Engr in Charge.
M&L for Preparing new surface of wall (plastered) and applying two coat of oil Bound distemper (OBD) on wall over one coat of alkali resistant primer of approved tints all as specified and direceted by Engr-in-Charge.
M&L for Preparing new plasterd unplastered surfaces and applying three coats of white wash on Ceiling .
Dismantling floor, hearth or wall tiling including cement mortar bedding, removing serviceable tiles to stores and removing debris outside the MD land.
M&L 20 to 25mm thick machine cut kota stone slab flooring laid and jointed with gray cement slurry with pigment to match the shade of the slab including rubbing and polishing complete including 20mm thick screed bed in cement mortar 1:6 all as specified.
M&L kota stone slab skirting 20mm thick over cement screed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete inlcuding 10 mm thick screed bed in vertical surface of stone / PCC block wall in cement mortar 1:4 all as specified.
M&L for makarana marble tiles 30cmx20cm x 20mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing complete over and including 20mm thick screed bed in CM 1:6 complete all as specified and as directed.
S&F Non-skid ceramic Coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified.
S&F Glazed ceramic tiles 350 x 250 x 7mm /450 x 350 x 7mm thick, in vertical surfaces and such as skirting, dados and riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match inluding 10mm thick screed bed in CM 1:4 complete all as specified.
Taking down chowkats with shutters (without taking off shutters from the frames) not exceeding 1.5 Sqm each complete.
All as per Item No 46 above but exceeding 1.50 Sqm but not exceeding 4 Sqm.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bar, dovetailed or welded complete all as specified.
S&F galvanized mild steel wire cloth 0.50mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
M&L 10-12mm square bar in MS framed guard bars confirming to grade Fe-290 welded to steel ventilators complete all as specified and directed.
S&F sheet glass, ordinary quality 3mm thick fixed with oil putty size of glass not exceeding 0.50 Sqm in each pane complete.
S&F steel ventilator with top hung shutter inc. hinges,steel peg stay,complete
S& F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as specified and as per drawing.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consistiing of frame made out of MS tubes for top and bottom rail MS frame, shall be covered with heat moulded channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fited in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawing.
S&F pressed steel frames for doors with one or more rebates inc,necessary fixing lugs,hinges,lock strike plate,etc of size of frame 165x60mm , complete ,as specified,supplied and fixed
M&L for cement concrete of type C1 1:3:6 ( 20mm graded aggregate )in lintels upto 1.5m clear span,cills,steps;seismic and other similar bands,plinth courses,string courses,lacing courses,parapets and railings upto 60cm in height,copings,kneelers,apex stones,bed plates,kerbs not provided for in item 4028,water troughts and the like inc.weathering,slightly rounded or chamfered angels and throatinf,as directed
S&F second class hard wood 35mm gauged and skeleton shutter factory made without sash bars open rebated and prepared to receive gauge etc. top, bottom and lock rail, styles, edges of framing champhered or rounded fitted with cut and mitered wooden beads for securing glass, etc; size of members of shutters as specified in SSR Part-I, Section 8, Clause 8.24 (a); supplied and fitted to chowkats.
S&F factory made second class hard wood plain framed panelled shutter (Two panel) with lock rail and pannel of 9mm thicks BWP commercial ply or 12mm veneered parlide board with commercial vereered on both faces the size of rails and style as per IS-1003 (Part-I) kiln seasond and chemicadly pressue treated 35mm thick all as specified and directed.
S&F 100mm size Stainless steel hinges and fixed to PVC frame and angle iron frame by necessary welding complete all as directed.
S&F extruded aluminum alloy handle fabricated type anodized, 150mm size.
S&F aluminum anodized barrel tower bolts extruded section, 150mm size.
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed 250mm in length.
M&L for preparing old decorated steel surfaces of any description not otherwise described exceeding 10 cm width or girth and applying one coat of synthetic enameled paint incl,cleaning glass,joinery etc. of drop&splashes all as specied and directed by Engineer -in Charge.
M&L for preparation of new wooden surfaces of any description, over 10cm in width or girth, not otherwise specified with two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
M&L 75mm thick cement concrete 1:3:6 type C1, using 20mm crushed stone aggregate finished even and smooth without using extra cement as in plinth protection and floors etc complete all as specified.
M&L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound,grade'A'
Demolition of briclwork or stone masonry built in cement mortar including all quoins or pillars etc.
M&L for stone masonry Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6.
M&L for removing mortar from and cleaning stones,obtained from masonary of any description (except ashlar facings and dressed stone work) and stone setts from pavings,stacking for measurement inc.all extra handling and removal and disposing off rubbish
M&L for stone masonry Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 but except stone.
M&L fot Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exc 40mm of sand stone and dressing face beds and joints as specified to random rubble walling uncursed or brought upto courses all as specified and directed.
Demolition of brickwork or stone/boulder masonary,laid dry built in cement mortar inc.all quoins or pillars etc .or pillars etc.
M&L brickwork with fly ash bricks, straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed.
M&L brick work with fly ash brick, straight or curved on plan any radius as in half brick thick walls built in CM 1:4 complete all as specified and as directed.
Demolition of Reinforcement cement concrete Roofs,floors (other than ground floors),beams,staircases,landing,chajjas and similar suspended work and all as specified and directed.
RCC M-25 design mix as in slabs supported on walls, beams and colunms in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide includingrough finished surfaces complete all as specified and directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including fair finished surfaces complete all as specified and directed.
Use and waste of form work to sides and soffits of lintels, beams, brackets, shelves and similar works for rough finished surfaces of concrete complete all as specified and as directed.
M&L TMT steel bars of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M&L TMT steel bars of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
Supply only liquid water proofing compound ( ISI Marked)
M&L for Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face complete all as specified and as directed .
M&L 10mm thick plastering on floor surface in cement mortar 1:3 finished even and smooth without using extra cement on stone masonry and concrete surface all as specified.
M&L for APP based polymeric membrane minimum weighing not less than 3kg / Sqm and minimum 3mm thick reinforced with polyester non woven fabric weight not less than 150 gms / Sqm and on primed surface of one coat of approved bituminous [email protected] Ltr per Sqm by torch application method complete all as specified and as directed .
M&L 15 mm thick sreed bed or bedding layer in cement mortar 1:3 for laying floor finishes and complete all as specified.
M&L Cement concrete tiles 25cmx25cmx22mm thick machine pressed set jointed and pointed in neat cement slurry in floors and cut and polished
Demolition of concrete in ground floors and paving n exc 15cm thickness (below or above ground level )
M&L 100mm thick cement concrete type D-2, 1:4:8 (40mm graded crushed stone aggregate) finishing cement concrete surface even and smooth without using extra cement as specified and directed.
M&L 100 mm thick cement concrete type B-1, 1:2:4 ( 20 mm graded crushed stone aggregate) finishing cement concrete surface even and smooth without using extra cement as specified and directed.
M&L for sand filling 25mm thick under floors or in foundations inc. watering and consolidation
M&L 60 mm thickfor machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness,M-35 grade.
M&L for pre-cast cement concrete block of type C1 1:3:6 (20mm graded aggregate) masonary with solid blocks,exc.10cm in width and setting in mortar complete all as specified and directed
Demolition of cement concrete ( unreinforced) in roofs , floors (other than ground floors) beams, staircases,landing, chajjas and similar suspended work
M&L for plain cement concrete 1:2:4 type B0 using 12.5 mm graded aggregate as in roof for maint. the uniform slope etc any thickness at any height and in any position all as specified and directed by engr-in-charge at site.
M&L providing reinforced cement concrete type B1 (1:2:4) using 20 mm graded stone aggregate as in ,copings and the like including s, incl necessary form work weathering, slighting rounded or chamfered angles and throating all as directed and specified.
M & L 15 mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces on fair face , surface finished even and smooth without using extra cement complete all as specified.
M&L for applying of two coat of cement base paint in camaflounge pattern over old wall surfaces including preparation of surfaces complete all as specified and directed by Engineer-in-charge.
M&L one coat of synthetic enamel paint in camaflounge pattern over old surface of any description over 10 cm girth or width not otherwise described including surface preparation
M&L for one coat of distemper on ceiling including surface preparation all as specified and directed.
M&L for one coat of distemper on old wall including surface preparation all as specified and directed.
M&L Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer of mortar for laying floor finishes in cement mortar 1:6 as specified and directed
M&L Glazed ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick in CM 1:6 on other than fair faces of brick or concrete surfaces and complete all as specifeid.
M&L for 20-25 mm thick machine cut kota stone slab flooring set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 20 mm thick screed bed in cement mortar 1:3 ,rubbing , polishing complete inclu Demolition Stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar all as specified and directed.
S &F Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete. Including taking down old Stone slabs and tiles of any description or thickness in floors, aprons etc including 20 mm thick screed bed in CM 1:4
M&L three coat of white wash on walls including preparation of new plastered surface and complete all as specified
M&L for applying of two coat of cement base paint over a coat of primer on new wall surfaces including preparation of surfaces complete all as specified and directed by Engineer-in-charge.
M&L for applying of one coat of cement base paint over old wall surfaces including preparation of surfaces complete all as specified and directed by Engineer-in-charge.
Refixing 15mm bore old steel water tubing and connection in new or old position (walls, ceilling, floor etc)
Refixing 20mm bore old steel water tubing and connection in new or old position (walls, ceilling, floor etc)
S&F, 200 mm long aluminium anodised barrel barrel tower bolts of extruded section and fixed as specified and as directed.
S&F, 125 mm aluminium handles cast type, anodised complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 using 12.5 mm graded stone aggregate as in kerbs benching, haunching corbelling and channel etc finished even and smooth with out using extra cement.
Cutting chases, pinning in making good to facing on brick walls & pointing in CM 1:3 for concealed water tubing cutting n exc 10 cm girth all as specified and as directed.
M&L for Providing PCC 1:3:6 type C-2 (40 mm stone agg) as in plinth protection 75 mm thick finishing cement concrete even amd smooth without ung extra cement. Including includind Demolition of cement concrete (un reinforced) in ground floor or pavings of any sidescription n exc 15 cm thickness (below or above ground level)
M&L forming 12mm thick expansion joint filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade 'A' for 75mm thick slab
Dismantling of existing water tanks capacity exc 500 ltr but n exc 1000 ltr and removing to store
Demolition of cement concrete ( reinforced) in roofs , floors (other than ground floors) beams, staircases,landing, chajjas and similar suspended work( reinforcement cut as required to facilitate demolition)
S&F rotational moulded polethylene water tank of 1000 ltrs capacity ( cylindrical vertical with closed top) hoisted and fixed in position all as pacific SSR Part- I
M& L for roof treatment in the following stages (a) Apply first coat of bitumin primer confirming to IS 3384-1986 @ 0.40Kg/ Sqm over and including 10 mm thick cement mortar (1:4) mixed with water proofing compound as per manufacturer's instruction surfaces finished even and smooth without using extra cement all as specified (b) Second coat of bonding material using blown type bitumen confirming to IS- 702-1988 grade 85/25 @ 1.20 Kg/ Sqm (c) Third layer of APP modified polymeric membrane centre core of 100 micron HMHDPE outer film 20 micron each sides, thickness 2.0 mm having weight 3.00 Kg /Sqm (d) Fourth coat of bonding material using blown type bitumen confirming to IS 702-1998 of grade 85/25 @ 1.20 Kg/Sqm
Demolition of RCC / plain cemant concrete of any description and in any position incl removing of debries all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 with 2%WPC by weight of cement, applying evenly a coat of bituminous primer confirming to IS 3384 - 1986 @ 0.30 Kg/Sqm and laying of APP modified membrane with 100 mm over lap in longitudinal direction and 100 mm in transverse direction weight not less than 3 Kg/Sqm all joints and changes in directions should be curved with CM 1:3 mixed with SBR latex @ 200 ml/Bag of cement and cured well before laying the membrane complete all as specified and as directed
M&L PCC 40mm thick 1:2:4 of type B-1 using 20mm graded stone aggregate as in floorsfinished concrete surface even and smooth without using extra ement
Forming V grooves in concrete n exc 10 mm deep and n exc 10 mm on face complete all as specified and as directed.
M&L PCC 1:5:10 type E-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete as bedding for squatting pan etc complete all as specified and as directed.
M&L PCC 25mm thick 1:2:4 of type B0 using 12.5mm graded stone aggregate as in base of floors
S&F in repair 15 mm dia bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and directed.
S&F in repair vitreous china wash basin white, oval shape , size 550x400 mm excluding tap waste but including brackets and including cutting for and pinioning in ends of brackets but exclusive of supply waste pipe all as specified
Supply only 32mm dia wast fittings brass chromium plated for basin with long screwed shank and fly nuts, flange end bedded in red lead cement and other end fixed.
S&F 1200X900mm bevelled edges mirror consisting of 5.5mm thick commercial plywood and fixed to plug with chromium plated brass screwed and cup washer
S&F 32mm bore low density polyethylene pipes waste pipe (LDPE) pressure rating 6 kg/ cm2 of fixed complete to walls, ceiling or laid in floors all as specified.
S&F 75 mm dia PVC (SWR) floor trap plain with greting incl jointing with solvent cement
M&L for 5mm thick rendering on concrete surface of ceiling in CM 1:4 and rendering is to be finished even and smooth with out using extra cement
S&F 20 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe
S&F 20 mm dia Ball valves ,high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule
S&F PVC connection 15mm bore length not less than 300 mm long with both ends PTMT nuts complete all as specified.
Taking up or down 75 mm dia existing asbestos cement pressure pipe any class ,(including all fitting ) including disconnecting pipes and fittings complete
Taking up or down 110 mm dia existing asbestos cement pressure pipe any class ,(including all fitting ) including disconnecting pipes and fittings complete
S&F 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints laid in trenches or in floors all as specified
S&F 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints fixed to wall all as specified
S&F 75 mm bore. PVC (SWR) bends
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall
S&F 110mm bore PVC (SWR) bends with oval access door all as specified
S&F 110 mm PVC (SWR) bend any radius
S&F 110mm bore.PVC(SWR) junction single (single T) equal or unequal with access door
S&F in repair Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union
Dismantling wrought iron or mild steel of any description all as specified and directed.
Supply only chain link MS galvanised fencing any size or type all as specified and directed.
Fixing only chain link fencing including line wires any mesh,any mesh,size and type to any to any type of standards,rails,straining bolts,etc including provision of binding wire all as specified and directed.
M&L mild steel purpose made with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut exc 30.cm long, dia of shank exc 12 but n exc 20 mm all as specified and directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M&L framed work such as grills grating etc with end of bars shoulderd and/or riveted .welded or forged into spikes.framedguard bars iron doors.ladders framed balusters , walk ways. Railings, frame work of of water tanks and ssimilar work conforming to Fe410 all as specified and directed.
Taking down carefully from roof/ wall of the building loose/ hanging/ de-shaped, aluminium strips of any size & type including unserviceable insulators etc complete all as directed by Engineer -in-charge.
Refixing serviceable aluminium strips of any size as obtained from item above with porcelin insulators of 15 BMD size 'T' type placed not more than 50cm apart with screws /nut/bolts etc complete all as directed by Engineer -in-charge.
S & F aluminium strip 25mm x 3.15mm fixed with saddles & fixing screws of size not less than 4 mm dia and 32 mm long for roof conductors and down conductors above ground with porcelin insulators of 15 BMD size 'T' type placed not more than 50cm apart with screws /nut/bolts etc complete all as specified and directed by Engineer -in-charge.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75X75X25mm drilled and screwed including 4 nos. 8mm dia 25 mm long hexagonal head brass screws, and screwed to wall for protection of test point including 80 mm x 80 mm x 40 mm PVC box for Gun made block fix to the wall by means of screws and nuts including taking down old unserviceable test terminal point complete all as specified and directed by Engineer -in-charge.
M&L for Air termination, single pointed, Aluminium rod 12mm dia and 300mm long fixed with the roof in and including all fittings, fixtures including taking down old unserviceable Air termination rod of any size complete all as specified and directed by Engineer -in-charge.
Taking down carefully from wall of the building loose/ hanging/ de-shaped, GI strip of any size type including unserviceable Galvanised iron pipe of any dia bore complete all as specified and directed by Engineer -in-charge.
Refixing serviceable GI strips of any size as obtained from item above with GI pipe of any size on wall/floor with clamps and nuts and bolts of suitable size etc complete all as directed by Engineer -in-charge.
M&L Galvanised iron strip 32x6 mm burried in ground/PCC hard standing /fixed on wall including all necessary excavation and earth work, connecting at ends, jointing etc complete all as specified and directed by Engineer -in-charge.
M & L for replacement of U/S plate earthing with bore well earthing by drilling bore with bore machine for lightening protection system using GI pipe heavy duty 50 mm dia as earth electrode driven up to a depth of 50 meters below ground level, duly made holes at 20 cm intervals, along the length of GI pipe and providing the charcoal salt mixture incl GI pipe 150 mm dia light grade as protection upto a depth of 12 meters and GI strip of 30x5 mm so as to acheive desired earth results. Testing and commissioning complete. (Earth strip of size 30x5mm upto a length of 7.5m is deemed to incl in this item rate).
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etccomplete all as specified and directedby Engineer-in- Charge.
Taking down carefully old unserviceable burnt MCB DB with MCBs and keeping in safe custody for issuing under Sch of creditcomplete all as specified and directedby Engineer-in- Charge.
M/L Point wiring complete with 1100volt grade PVC insulated unsheathed multistranded 1.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor and connected to earth dolly, including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches sockets etc concealed on wall complete all as specified and directed by Engr-in-Charge : (a) One light point controlled by one, one way switch
All as per Srl Item No 165 above but One ceiling fan/exhaust Fan point controlled by one, one way switch.
All as per Srl Item No 165 above but One socket outlet 5 Amps on same board with other switches, with cables 1.5 sqmm size.
All as per Srl Item No 165 above but One socket outlet 3 Pin 5 Amp on independent board, with cables 1.5 sqmm size.
All as per Srl Item No 165 above but One 3 pin socket out let, 15 Amps, Independent Board with cables 4 Sqmm size along with 4.00 Sqmm earth wire.
S&F in repairs MCB DB SPN double door 8 way sheet metal enclosure SPN 240 V 50 Hz horizontal with IP-20 degree protection complete all as specified and directed.
M&L in repairs for MCB SPN 40 Amps 230 VoltsC series complete all as specified and directedby Engineer-in- Charge.
M&L in repairs for MCB SP 5-30 Amps 230 VoltsC series complete all as specified and directedby Engineer-in- Charge.
S&F in repairs Switch piano 5A one way 230 Volts surface mounting Flush type complete all as specified and directedby Engineer-in- Charge.
S&F in repairs Switch piano 15A one way 230 Volts surface mounting Flush type complete all as specified and directedby Engineer-in- Charge.
S&F in repairs socket outlet outlets multipurpose 2 in 1, 5A Flush type(ISI marked) all as specified and directed by Engineer-in-charge.
M&Lin repairs socket outlet combination 5A/15A, 5 in 1, Flush type complete all as specified and directedby Engineer-in- Charge.
S & F in repairs Ceiling rose, two to three terminal /PVC/Polycarbonate, isolated body complete all as specified and directedby Engineer-in- Charge.
S&F in repairs LED light fitting 1x10 watt bulk headsurface mounted,decorative oval bulk head edgelit LED luminaries comprising of high brightness LEDs etc. complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed.Make :-Havells cat part No. RGBYNEONFT10WLED860SSMTOPCC or equivalent philips/havells/bajaj/wipro etc.
S&F in repairs lamp holder complete all as specified and directed by Engineer-in- Charge.
S&F in repairs LED Lamp 9 W of make CG/BAJAJ/PHILIPS.
S&F in repairs LED tube light fitting , single tube surface/ pendent mounting 1x20 watt complete with electronic LED driver etc complete with tube rod all as specified and directed by Engineer-in charge.
S&F in repair LED Street light made up of pressure die cast aluminium housing with LED 25W as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and other accessories fixing on wall with and including bracket and made out of 25 mm dia GI tube light grade 1.2 mtr bend to shape as required including 02 Nos MS clamp (FI 25 x 3mm) with nuts and bolt washer including taken done old light fitting complete all as specified and as directed including testing complete. Make :-Havells cat part No. SL25WLED757SASTOPC or equivalent philips/havells/bajaj/wipro etc.
Dismantling and taking out old burnt out winding and bearing of ceiling fan 1200/1400 mm sweepand rewinding with same gauge & sizeof copper winding wire of superior quality including replacement of 23/0.0076 twin core PVC insulated flexible copper wire of required length complete including painting the fan with two coats of synthetic enamel paint of white colour, replacement of worn out bushes,bearings, capacitor, PVC bushes, writing MES Number etc and fixing at same position after repair complete all as specified and directedby Engineer-in- Charge.
S & F in repairs exhaust fan 300mm sweep including provision of 3 core 23/0.0076 size flexible copper cable from ceiling rose to fan, incl.taking down old existing fan complete all as specified and directed by Engineer-in- Charge.Make Havells or equivalent.
Earthing complete in repair with galvanised steel earth plate electrode size 600x600x6.0mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by GI protection pipe medium grade 15mm dia connected to main earth wire on pole or control board and GI pipe light grade 20mm bore for watering, funnel with wire mesh. PCC chamber pit in PCC 1:3:6 type C-1, 40 mm thick precast RCC M-25 (design mix) cover reinforced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50 m complete all as specified and shown in electric plate No.03 of SSR Part-I(2009), connecting to earthing test point all as specified and directed including testing on completion. NOTE FOR ITEM NO. 23:- (i) The unit rate includes for protection pipe and earth lead upto 7.50 meter. (ii) Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured separately. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional height of watering pipe bends elbow etc shall be deemed to be included in the unit rate.
S & F tubes, medium grade (ISI marked), galvanized iron with and including all fitting (ISI marked) laid in trenches complete GI pipe 40 mm bore all as specified and as directed .
S & F tubes, medium grade (ISI marked), galvanized iron with and including all fitting (ISI marked) laid in trenches complete GI pipe 25 mm bore all as specified and as directed.
Supply and fixing in replacement gun metal gate valves with iron wheel head, screwed both ends for jointing iron pipe and fixed complete all as specified and as directed suitable for 25 mm sizes.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth and getting out loose soil for laying of electrical cables
Returning filling in including spreading levelling watering and well ramming in layer not exceeding 25 cm in any type of sale.
Removal of excavated material to distance 50 m and deposing where directed at a level not exceeding 1.5 m above the starting point.
6. Material and labour for sand cushioning to under ground electric cable all as per clause No 19.75 of MES SSR Part-I (1991)
M & L for 40 to 50 mm thick rough dressed sq mtr. Jodhpur type stone slab cover 25 to 30 cm wide and 80 cm in length , gaid dry abutting each other for under ground protection.
Supply and lay cable XLPE insulated screened PVC beded, gavanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sq mm 2 core.
Supply and fix in repair of outdoor feeder piller boxes otdoor type factory made cubicle type weather and vermin proof fixed on and including ventilation and louvers arrangement space for MCCB 63Amps complete with bus bar PCC 1:2:4 type B1 foundation of required suitable size and as directed at site with angle iron frame 40x40x6mm for 415 Volts 3 Phase 4 wire 50hz
S & F in repairs smart Integrated Solar All in One with > 140 Lum/W, MPPT charge controller , Tiltable LED Panel, Adjustable A10 mounting angle, (along with GI pipe 50mm bore -06 RM and necessary PCC) Monocrystalline Solar Panel, PIR motion sensor MOQ 20 Nos solar panel 60 battery 12.8V 20Ah system wattage 20 Cat Part No CSADEMPS20CDL of Crompton or equivalent complete all as specified and directedby Engineer-in- Charge.
National Rewinding Works
m/s sai construction company,bijarar
SOHANLAL MOHTTA
m/s jogaram sujaram
M/S Tanisha Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .