Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹19.1 L+₹1.8 L (10.4%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹21.2 L+₹3.9 L (22.8%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹22.1 L+₹4.8 L (27.7%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest | |
| 5 | L5₹24.4 L+₹7.1 L (41.1%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
2 Jun 2020, 6:00 pmClosed
Lt Col Vipin Kumar Singh
GE (S) Ahmednagar, Military Engineer Services, Ahmednagar- 414002
Repair and maintenance of LT network, LT UG Cable, LT Panels ,Conductors, external electric supply for water supply installation at ACC and S area Pump houses and misc E/M works at CQA(V) and DAD under GE (South) Ahmednagar
2020_MES_329558_1
8687/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
AHMEDNAGAR
Class E cat b (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (S) Ahmednagar
₹50,000
Yes
15 Jun 2020
28 Feb 2020
4 Jun 2020
28 Feb 2020
2 Jun 2020
14 Mar 2020
28 Feb 2020 - 6 Mar 2020
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed.
All as per item No 01 above but in hard/dense soil or bituminous road/ hard standing.
All as per item No 01 above but exceeding 1.5 Mtr but not exceeding 3.00 mtr
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Supply and laying HDPE pipe 40 mm dia for laying of LT cables etc. complete with all as specified and directed. Make : Vectus industires/ Supreme/ Infra/ Astorn Plastic
Supply and laying HDPE pipe 65 mm dia for laying of LT cables etc. complete with all as specified and directed. Make : Vectus industires/ Supreme/ Infra/ Astorn Plastic
Disconnecting & taking out cable LT 1100V grade any of any size complete all as specified and directed.
LT XLPE underground cable 1100 Volts grade heavy duty, 2 core 6 Sqmm, with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall sheathed including cable gland, lug, jointing material etc, laid in trenches or fixing or passing through pipe including jointing, connecting , testing and commissioning complete all as specified and directed. Make: Havells/Polycab/RR cable
All as per Ser item No 9 here-in-before but LT cable of size 2 Core 10 Sqmm
All as per Ser item No 9 here-in-before but LT cable of size 2 Core 16 Sqmm
All as per Ser item No 9 here-in-before but LT cable of size 4 Core 16 Sqmm
All as per Ser item No 9 here-in-before but LT cable of size 3.5 Core 25 Sqmm
All as per Ser item No 9 here-in-before but LT cable of size 3.5 Core 35 Sqmm
All as per Ser item No 9 here-in-before but LT cable of size 3.5 Core 50 Sqmm
All as per Ser item No 9 here-in-before but LT cable of size 3.5 Core 70 Sqmm
All as per Ser item No 9 here-in-before but LT cable of size 3.5 Core 95 Sqmm
All as per Ser item No 9 here-in-before but LT cable of size 3.5 Core 120 Sqmm
All as per Ser item No 9 here-in-before but LT cable of size 3.5 Core 150 Sqmm
All as per Ser item No 9 here-in-before but LT cable of size 3.5 Core 185 Sqmm
All as per Ser item No 9 here-in-before but LT cable of size 3.5 Core 240 Sqmm
GI pipe 80 mm bore light grade for cable protection, ISI marked with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
GI pipe 40 mm bore light grade for cable protection at road crossing etc including necessary road cutting and making good with PCC 1:2:4, Type B-1, using 20mm graded stone aggregate, 100 mm thick or for fixing along wall / poles of any type, secured with clamps of suitable size complete all as specified and as directed.
GI pipe 50 mm bore light grade for cable protection at road crossing etc including necessary road cutting and making good with PCC 1:2:4, Type B-1, using 20mm graded stone aggregate, 100 mm thick or for fixing along wall / poles of any type, secured with clamps of suitable size complete all as specified and as directed.
HT XLPE cable PVC insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) with stranded aluminium conductor 11000 volts grade, of size 120 Sqmm, 3 core, including laying, jointing, testing and commissioning complete all as specified & directed. Make: Havells/Polycab/CCI/Universal
Cable jointing kit for 11KV HT (Earthed) grade Cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoued aluminium conductor cable of size 120 sqmm to 185 sqmm type with all accessories as in replacement complete all as specified and directed. Make :Denson/M-Seal/ Rechom
All as per serial item No. 26 here-in-before but straight through joint for 120 Sqmm to 185 sqmm 3 core HT cable.
Dismantling of old steel pole / struts any type and size including demolition of concrete, foundation, necessary excavation and earth work and transportation etc. complete all as specified and directed.
Steel tubular swaged pole complete with MS base plate 6 mm thick of size 300 x 300 mm finial taper plug, cap, bolt, nuts washers & screws as specified type 410-SP-31 (9 mtr long) made out of ERW MS tubing confirming to IS-2713 Part II including drilling holes of required size for fixing cross arms etc painting with two coat of aluminium paint over a coat of red oxide primer, duly erected in truel vertical position complete all as specified and directed.
Steel tubular swaged pole complete with MS Box plate 6 mm thick of size 300 x 300 mm finial taper plug, cap, bolt, nuts washers & screws as specified type 410-SP-55 (11 mtr long) Made out of ERW MS tubing confirming to IS-2713 Part II including drilling holes of required size for fixing cross arms etc painting with two coat of aluminium paint over a coat of red oxide primer, duly erected in truel vertical position complete all as specified and directed.
Demolition of PCC of any description above or below ground level exceeding 15 cm thickness complete all as specified and directed.
PCC 1:4:8, type D2 using 40mm graded stone aggregate for pole / struts foundation etc complete all as specified and directed.
PCC 1:2:4, type B1 using 20 mm graded stone aggregate as in coping etc. including necessary form work and fair finishing of exposed surface of concrete fair and even complete all as specified and directed.
PCC 1:3:6, type C2 using 40 mm graded stone aggregates for stays complete all as specified and directed.
Dismantling/taking out stay assembly of any descripiton keeping aside for further disposal complete all as directed.
Stay assembly comprising of 16 mm dia stay rod 1800 mm long, loop type insulator of size 65 mm x 90 mm, galvanised stay plate 6 mm thick of size 250 x 250 mm, stay bow, fixed in repairs complete all as specified and directed & shown in EP No. 1 of SSR Pt I. Note : Excavation/earth work PCC shall be measured and paid seperately.
Galvanised stay strand 7/4 mm size fixed complete all as specified and directed.
Loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions 90 mm x 140 mm, clearnce of hole 25.5 mm, fixed in position complete all as specified and directed.
Dismantling cross arms, MS Channel or angle section etc complete all as specified and directed.
Switch Air break gang operated device triple pole mechanically operated, mounted on insulator and steel frame with operating mechanism working from ground level for current rating upto 200 Amp, 11000 Volts all as existing complete all as specified and directed.
Cross arms. bracings, support channel, backpate hooks etc fabricated from structural steel sections MS angle, channel and flat etc of required size and shape including nuts, bolts,washers, welding, bending , cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Dismantling of GI cradle / earthwire / stay strand etc. complete all as specified and directed.
GI continuous earth wire 4mm dia for cradle/guarding, fabricated with galvanised steel wire 3.15 or 4 mm dia connecting properly to cross arms hook etc with and incl 22 SWG binding wire all as specified and directed.
Lightnening arrestor for outdoor use, non-linear resistor type, horn gap and choking coil, maximum working pressure 1100 volts grade, fixed in replacement complete all as specified and directed.
Dismantling LT insulator any type any size complete all as specified and directed.
Pin type porcelain, vitreous, while or brown insulator including galvanised MS spindle , two galvanised iron washers & one galvanised iron nut, 100 mm height 65 mm dia for 1100 Volts grade fixed in replacement complete all as specified and directed.
Pin type / post type porcelain, vitreous, while or brown insulator including galvanised MS Spindle , two galvanised iron washers & one galvanised iron nut, 150 mm height and 150 mm dia for 11000 Volts grade, fixed in replacement complete all as specified and directed.
Disc type insulator ,porcelain,vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green single disc assembly with tension clamp for 11000 volts fixed in replacement complete all as specified and directed.
Reel type / spool insulator porcelain, vitreous white brown insulator incl galvanised mild steel straps, washers insulator, bolts, washers and nuts of size 40 mm dia X 20 mm height X 12 mm hole, section of strap 31 x 3 mm, dia of bolts 12 mm working pressure 1100 Volts fixed in replacement complete all as specified and directed.
Shackle type insulator porcelain, vitreous white brown insulator including galvanised mild steel straps, washers insulator, bolts, washers and nuts of size 75 mm height, 90 mm dia, section of strap 31 x 3 mm, dia of bolts 12 mm working pressure 1100 Volts complete all as specified and directed.
Overhauling GOD set by replacing stationary and moving contacts adjusting from ground level for smooth operation by replacing flexible copper strip, insulators, nuts, bolts, washer, GI pipe handle etc, complete all as specified and directed. (Note- Stationary/ moving contact, post insulator, GI pipe and handle shall be measured & paid separately).
GOD handle with locking strip and insulation sleeve, fixed in replacement complete all as specified and directed.
LT line spacers polyproplene composite phase seperators (Moulded or Bolted type) 4 lines, fixed in replacement complete all as specified and directed.
LT line spacers polyproplene composite phase seperators (Moulded or Bolted type) 5 lines, fixed in replacement complete all as specified and directed.
Male Contact / Moving contact blade (with Insulators) complete set, fixed in replacement complete all as specified and directed.
Female Contact/Fix contact blade (with Insulators) complete set, fixed in replacement complete all as specified and directed.
Replacement of MS Jumper carrier, fixed in replacement complete all as specified and directed.
Dismantling ACSR conductor from LT/HT pole complete all as specified and directed.
ACSR Conductor including stringing, binding, jointing, jumpering etc with insulators on poles with minimum sag complete all as specified and directed for the following sizes:-
1/6 x 2.59 mm Weasel
6/1 x 3.00 mm Ferret
1/6 x 2.19 mm Squirell
Danger notice plate of 1.6 mm thick mild steel sheet of size 20x15 mm,painted vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with screws on LT panel boards complete all as specified and directed.
Restringing / restretching of LT OH line by replacing pin binding with new aluminium conductor and maintaining sag within permissible limit for following runs :-
2 runs of ACSR conductor
5 runs of ACSR conductor
6 runs of ACSR conductor
Obtaining written shut down from concerned JE/AGE (E/M), trimming / prunning of tree branches touching to the LT over head line or near to the LT over head line as per the direction of AGE E/M/JE incharge complete including removing the tree branches from site complete all as specified and directed by Engr in Chatge. Note :(I) Span from one pole to next pole ( 30 to 50 RM) will be considered as a one Job (ii) Any damage caused due to contractor workmen will be rectified without any extra payment (iii) T & P such as ladder,rope,cutter, axes and other related material will be provided by the contractor.
Repairs to LT panel boards complete wiring with suitable size / existing size copper cable with necessary works complete all as specified and as directed by Engineer-in-Charge
Repairs to LT panel boards complete with necessary welding works to doors, replacement of unserviceable hinges and all drop bolts complete and painting with one coat of synthetic enamel paint of approved color internally and externally complete all as specified and as directed.
Preparation of surfaces for HT/LT swaged poles by scrapping damaged paint and painting with two coats of silver aluminium paint and writing pole No with black paint on yellow colour complete all as directed.
Replacement of damaged sheet of panel board of size 14 SWG to match to existing sheet including bending, cutting, pressing to required size and shape including painting with two coats of synthetic enamel paint over a coat of primer to match the existing surface complete all as directed.
Taking out old unserviceable MCCB TP/TPN four pole from existing LT panel board and supply and fix MCCB TP 25-100 amps, rup capacity 16 KA at 415 volt 50 Hz AC supply including necessary modification in panel board if required to fix the MCCB complete and making incoming and out going cable connection with lugs, aluminium conductor cable of proper size, nuts bolts etc. complete all as specified and directed. (Make- L&T/Siemens/Schneider] ( Ics = 100% Icu)
All as per Item No 67 above but 125 amps capacity, 25 KA complete all as specified and as directed.
All as per Item No 67 above but 160 amps capacity, 36 KA complete all as specified and as directed.
All as per Item No 67 here-in-before but MCCB of 200 amps capacity, rup capacity 35 KA, 415 Volts complete all as specified and as directed.
All as per Item No 67 above but MCCB of 315/400 amps capacity, rup capacity 35 KA , 415 volt complete all as specified and as directed.
Voltmeter 0-500 volt square type complete including necessary fixing, fixed in replacement complete all as specified and as directed.
Ammeter 0-500 amps square type complete including necessary fixing, fixed in replacement complete all as specified and as directed.
Phase indicator lamps complete including necessary fixing, fixed in replacement complete all as specified and as directed.
Replacement existing unserviceable resin cast type twin secondary current transformer of ratio 200/100/5-5A, class 1 SP 10 for protection & metering cap 15 VA/15VA burden for protection and metering equipment to confirm IS : 2705 of 1992 complete all as specified and directed.
Jump connection by using ACSR conductor weasel, alkathine pipe ,aluminium lugs, nuts, bolts etc. complete all as directed .
Thimble stud type suitable for 185 Sqmm LT cable, fixed in replacement completre all as specified and directed.
All as per srl item No 77 here-in-before but thimble of size 120 Sqmm.
All as per srl item No 77 here-in-before but thimble of size 95 Sqmm.
All as per srl item No 77 here-in-before but thimble of size 70 Sqmm.
GI contineous earth wire 4 mm dia (8 SWG) running on poles of HT/LT overhead feeders, stringing, stretching, tightly connecting properly and binding to cross arms hooks etc with and including 22 SWG GI binding wire for earth continuity complete with all nuts, washers etc all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI wire 4.0 mm dia, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 15 mm, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point including testing on completion all as specified and directed. Note: These earthings shall be provided for poles; without provision of concrete earth pits.
Energy saving LED street light fitting 1 x 60 Watt pressure dia cast IP-65 complete with connecting using 1.5 Sqmm FRLS PVC insulated (unsheathed) single core cable, 1100 V grade with multistranded copper conductor (Upto 2.00 RM double run) testing and commissioning complete all as directed. Make: HPL Cat No- HPLLEDSL6060S or equivalent of Crompton Greaves, Philips, Surya, Havells.
Energy saving LED Street light fitting 1 x 90 Watt ECO pressure dia cast IP-65 complete with connecting using 1.5 Sqmm FRLS PVC insulated (unsheathed) single core cable, 1100 V grade with multistranded copper conductor (upto 2.00 RM double run) including testing and commissioning complete all as specified and directed. Make: HPL Cat No- HPLLEDST9060E or equivalent of Crompton Greaves, Philips, Surya, Havells.
LED post top lantern 35 Watt, with spun aluminium canopy & die cast aluminium spigot with opal PMMA acrylic diffuser pre wired with all accessories including making necessary connections with and including suitable suitable size copper conductor cable complete all as specified and directed. Make : Havells cat part No. CORALPT35WLED757PSYMTOPC or equvalent in Philips/GE lighting/HPL
Brackets made out of 50 mm bore GI pipe, medium grade, 1.5 mtr long, bend to shape and including suitable MS clamps made out of 40 x 6 mm flat iron, necessary bolts, nuts, washers etc complete and painting the clamps with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer complete all as specified and directed.
Brackets made out of 40 mm bore GI pipe, medium grede, 1.5 mtr long, bend to shape and including suitable MS clamps made out of 40 x 6 mm flat iron, necessary bolts, nuts, washers etc complete and painting the clamps with two coats of synthetic enamel paint over a coat of red oxide Zinc chromate primer all as specified and directed.
PVC weather proof, hinged door, junction box with 10 A aluminium bus bar, 240 V, neutral link and 1No MCB SP of 6 Amps, necessary fixing arrangement such as clamps, nut, bolts, etc including dismantling old unservieable junction box completeall as specified and directed. Make : Syntex, Cat No. GSJB 2014.
PVC sheathed round twin core cable of size 1.5 sqmm with stranded copper conductor including drawing through pole and connecting complete all as specified and directed.
Dismanthing/taking down carefully the defective street light/security light/ floodlight fittings/ Post top lanterns of any description and servicing / cleaning, checking connections, replacement of unserviceable spares, reassembling and refixing at its original location including reconnections and testing / commisssioning complete all as directed. Note: (i) Spares to be replaced shall be measured separately under relevant items of schedule. (ii) Cost of minor parts like screws, nut bolts, washers, pieces of wires and insulation tape etc required on site is deemed to be included in the quoted rates.
Supply and fixing the undermentioned spares required in replacement for repairs of Street light/security light / floodlight fittings/Post top lanterns:- .
LED drivers for 18 W LED panel lights/Post top /batten fittings any type and any make as per sample, fixed in repairs complete all as specified & directed. Make - CG/Philips/Havells/HPL
LED Drivers for 34 to 42 W LED panel lights any type and any make as per sample, fixed in repairs complete all as specified & directed. Make - CG/Philips/Havells/HPL
LED Drivers for 30 W LED Security light any type and any make as per sample, fixed in repairs complete all as specified & directed. Make - CG/Philips/Havells/HPL
LED Drivers for 40 W LED Post top lantern any type and any make as per sample, fixed in repairs complete all as specified & directed. Make - CG/Philips/Havells/HPL
LED Drivers for 45 W LED Security light any type and any make as per sample, fixed in repairs complete all as specified & directed. Make - CG/Philips/Havells/HPL
LED Drivers for 50 W LED Security light fittings any type and any make as per sample, fixed in repairs complete all as specified & directed. Make - CG/Philips/Havells/HPL
LED Drivers for 60 W LED Security light fittings any type and any make as per sample, fixed in repairs complete all as specified & directed. Make - CG/Philips/Havells/HPL
LED Drivers for 70 to 75 W LED Security light fittings any type and any make as per sample, fixed in repairs complete all as specified & directed. Make - CG/Philips/Havells/HPL
LED Drivers for 90 W LED Security light fittings any type and any make as per sample, fixed in repairs complete all as specified & directed. Make - CG/Philips/Havells/HPL
LED surg protectors for exisiting Size/Capacity LED fittings any type and any make as per sample, fixed in repairs complete all as specified & directed. Make - CG/Philips/Havells/HPL
Open Construction Ballast, heavy duty, Copper wound, SP 230 Volts, 50 Hz suitable for HPSV/MH 70 Watt. Make Havells of CP No LHBW07170036 or equivalent in make CG/Wipro/Bajaj.
Open Construction Ballast, heavy duty, Copper wound, SP 230 Volts, 50 Hz suitable for HPSV/MH 150 Watt. Make Havells of CP No LHBW20115036 or equivalent in make CG/Wipro/Bajaj.
Open Construction Ballast, heavy duty, Copper wound, SP 230 Volts, 50 Hz suitable for HPSV/MH 250 Watt. Make Havells of CP No LHBW20125036 or equivalent in make CG/Wipro/Bajaj.
High Pressure Sodium Vapour lamp tubular type of capacity 70 watt. Make - CG, havells, Wipro
High Pressure Sodium Vapour lamp tubular type of capacity 150 watt. Make - CG, havells, Wipro
High Pressure Sodium Vapour lamp tubular type of capacity 250 watt. Make - CG, havells, Wipro
Metal halide lamp 70 Watt, tubular type, 230 V, Make :- Crompton/Philips/CG
Metal halide lamp 150 Watt, tubular type, 230 V, Make :- Crompton/Philips/CG .
Metal halide lamp 250 Watt, tubular type, 230 V, Make :- Crompton/Philips/CG
Metal halide lamp 400 Watt, tubular type, 230 V, Make :- Crompton/Philips/CG
Metal Halide tube double ended 150 watt.
Open Construction Ballast, heavy duty, Copper wound, SP 230 Volts, 50 Hz suitable for HPSV/ MH 400 Watt. Make Havells or CG/Wipro/Bajaj.
Open Construction Ballast, heavy duty, Copper wound, SP 230 Volts, 50 Hz suitable for HPMV 250 Watt. Make Havells of CP No LHBG08125036 or equivalent in make CG/Wipro/Bajaj.
High Pressure Mercury Vapour lamp tubular type of capacity 125 watt. Make - CG, havells, Wipro
High Pressure Mercury Vapour lamp tubular type of capacity 250 watt. Make - CG, havells, Wipro
Ignitors suitable for 70-400W SON & MH lamps.
Electronic Ballast for Lamp Type 1x36/40W FTL/PL CFL. Make - Havells of CP No LHBF27904025 or equivalent in make CG, Wipro
Bipin holder for 18/20/36/40W FTL & 14/21/24/28 T5, 230 V Make - Havells of CP No LHYF11000099 or equivalent in make CG, Bajaj
Holder porcelain screw type suitable for 70 Watt to 250 WattHPMV/HPSV/MH fitting . Make -Havells/CG/Bajaj
Tube rod 36 watt cool, day light.
CFL 36 Watt 4 pin SU PLL 6500K. Make - CG/ Havells/ Philips.
Electronic Ballast 2 x 24 Watt, 230V ACSP 50 Hz T 5 type. Make - Havells of Cat Part No LHBT02224042 or equivalent in make Philips/Bajaj/CG
T-5 tube rod 24 Watt, cool day for 4 x 24 watt street light fitting. Make - CG/Havells/ Philips/Wipro.
Electronic Ballast 1x18W CFL. Make - Havells of CP No LHBC07118055 or equivalent in make CG/Bajaj.
Electronic Ballast 1x9/11/13W CFL. Make - Havells of CP No LHBC07113055 or equivalent in make CG/Bajaj.
CFL 18 Watt 2 pin SU/DU 6500K. Make - CG/ Havells/ Philips.
LAMP HOLDERS for non-retrofit 5/7/9/11W CFL (PL-S). Make - Havells of CP No LHYC12000099 or equivalent in make Crompton/ Bajaj.
LAMP HOLDERS for non-retrofit 10/13/18/26W CFL (PL-C). Make - Havells of CP No LHYC13000099 or equivalent in make CG/ Bajaj.
LAMP HOLDERS for non-retrofit 18/24/36/55 W FP-L. Make - Havells of CP No LHYC14000099 or equivalent in make CG/ Bajaj.
Spiral type Compact fluorescent Lamp 85 Watt suitable for batten Holder. Make - Havells of Cat Part No PHFR*#085 or equivalent in make CG/ Philips.
Lamp holder brass type with back plate suitable for batten fittings.
PVC insulated sheathed cable with stranded aluminium conductor of size 2.5 sqmm single core from fitting to over head line conductor, as in replacement complete all as specified and directed .Make: Havells/Polycab/Plaza/Universal
1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor cable 4 sqmm flat or circular with and including 4 mm suspension GI wire , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart complete all as specified & directed. Make: Havells/Polycab/Plaza/Universal
All as per item No 93 above but 6 Sqmm two core complete all as specified & directed.
Automatic timer switch digital type suitable for operation on 230 volt 50 Hz AC supply of 16 amps capacity, fixed in replacement complete all as specified and directed. [Make - L&T/Schneider/Havells]
Dehyderation, filtration and cleaning of transformer oil in indoor/outdoor/ pole mounted/plinth mounted transformers/ HT switch gear etc at different locations by suitable dehgydration plant including testing of oil sample before and after dehydration for each transformer/equipment and results of transformer insulation oil minimum upto 45 KV with 2.5mm gap, recorded jointly by contractor and Engineer-in-Charge complete all as directed Note : Oil for toping up/fresh fill shall be measured and paid seperately under relevant item. Dehyderation plant and all tools required shall be arranged by contractor under his own arrangements.
Transformer oil for toping up oil level with and including new insulating oil confoming to IS-335 having dielectric strength upto 45 KV with 2.5 mm gap complete all as specified and directed. Note: Dehyderation plant and all tools required shall be arranged by contractor under his own arrangements. Make : Savita/ APAR/HP
Repair to transformer in situ pole mounted/plinth mounted of any capacity to stop the leakage of transformer by lifiting core assembley with the help of chain pully block/crane, removing transformer oil, replacing cork sheet gasket 5 mm thick, reassembling, the transformer completely refilling transformer oil, connecting HT/LT connection complete all as directed. Note : Spares required shall be measured and paid separately.
Lightening arrester expulsion type complete with all fittings, transsmision class, discharge capacity 65 KA, suitable for 11000 Volts complete all as directed.
Replacement of unserviceable nuts/bolts/washers for various equipments complete all as directed.
Replacement of silica gel, cleaning breather and filling new silica gel complete all as directed.
Porcelain bushing LV side 440Volt of required/adequate size and shape fixed in replacement complete all as specified and directed.
LV rod brass 20 mm dia 300 mm long with rubber bushing and brass nuts 2 Nos fixed in replacement complete all as directed.
HV rod brass 20 mm dia 300 mm long with rubber bushing and brass nuts 2 Nos fixed in replacement complete all as directed.
Rewinding of transformer of capacity 150 to 500 KVA with super enamelled copper winding wire for HT/LT coils with existing gauge and number of turns , input 11000Volts output 415 Volts including dismantilling removing old winding etc applying insulation, varnish heating in oven to remove moisture, reassembling and testiing complete all as directed.
Painting the transformer of capacity 100KVA-500 KVA by spray painting with applying two coats of synthetic enamel paint including prepartion of surface by scrapping old paint and writing SM No, MES No, and capacity of transformer etc complete all as specified and directed..
Stone aggregate 40 mm graded spreading and leveling aroung 2 pole/ 4 pole structure where GODO is installed including well ramming complete all as specified and directed.
Cleaning/clearing of vegitation around the installations and disposing off the rubbish off the premises complete all as directed.
Akanksha Enterprises
G.A. Construction
OM SAI ASSOCIATES
AMAR CONSTRUCTION
Ms. S.K. ASSOCIATES
M/S MAHESHWARI ENTERPRISES
M/s AG PATHAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .