Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.1 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC L1 | |
| 2 | L2₹84.5 L+₹3.1 L (3.78%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹94.2 L+₹12.8 L (15.7%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | Rejected-Technical 3838 2ND FLOOR SECTOR 46 C CHANDIGARH UT 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | - | Rejected-Technical Two class below the eligibility class. |
Tender Value
₹99 L
EMD Value
₹1.7 L
Closing Date
5 Nov 2019, 6:00 pmClosed
Sh AP Singh, IDSE
HQ CWE Chandimandir
CA NO CWE/CHM(U)-49/2019-20 MANNING AND OPERATION FOR OPERATING ELECTRICAL INSTALLATIONS AT MAIN TOPs SUB STN NO 5, 7, 10, 12, SUB STN WGs AND DAY TO DAY ATTENDING OF EXTERANL COMPLAINTS AT CHANDIMANDIR CANTT
2019_MES_286672_1
CWE/CHM(U)-49/2019-20
Open Tender
Miscellaneous Works
Item Rate
270 days
HQ CWE Chandimandir
Class C, cat b(i) and d(v)
7 documents required · 7 mandatory
₹1,000
Yes
GE (U) Chandimandir
₹1.7 L
Yes
7 Jan 2020
1 Oct 2019
7 Nov 2019
1 Oct 2019
5 Nov 2019
22 Oct 2019
Amount
Outsourcing of services for operation and maint of power house at main TOP, receiving 66/11 KV supply in three feeders from HVPN Grid at Sector 1 Panchkulla, by deploying skilled electricians, technically qualified and experienced in operations of HT VCBs, round the clock for three shifts of 08 hours each including Sundays and holidays with 01 electrician in one shift of 08 hours, for the following :- [a] 11 KV HT VCB Panel board comprising of 04 Nos HT VCBs (01 incoming and 03 outgoings) of Make - Siemens. [b] 11 KV HT VCB Panel board comprising of 07 Nos HT VCBs and 02 Nos bus couplers ( 03 incoming and 04 outgoings) of Make - ABB. [c] Local transformer and connected LT Panel board - 01 No. [d] HT supply ring for three incoming feeders.
Outsourcing of services for operation and maint of power house at Mansa Devi 11 KV HT feeder TOP, by deploying skilled electricians, technically qualified and experienced in opeartions of HT VCBs, round the clock for three shifts of 08 hours each including Sundays and holidays with 01 electrician in one shift of 08 hours, for the following :- [a] 11 KV HT VCB Panel board comprising of 03 Nos HT VCBs ( 02 incoming and 01 outgoings) of Make - Schynider. [b] 11 KV HT VCB Panel board comprising of 05 Nos HT VCBs ( 02 incoming and 03 outgoings) of Make - Siemens. [c] 11 KV HT VCB Panel board comprising of 05 Nos HT VCBs ( 01 incoming and 04 outgoings) of Make - Siemens. [d] 11 KV/415 volts transformers 750 KVA - 01 No , 500 KVA - 02 No and 150 KVA - 01 No along with connected LT panel boards & changeover system. [e] HT supply ring for Solar plant and main TOP.
Outsourcing of services for operation and maint of power house at Sub Stn No 05 near HQWC, by deploying skilled electricians, technically qualified and experienced in opeartions of HT VCBs, round the clock for three shifts of 08 hours each including Sundays and holidays with 01 electrician in one shift of 08 hours, for the following :- [a] 11 KV HT VCB Panel board comprising of 03 Nos HT VCBs of Make - ABB - 01 No and 11 KV HT VCB Panel board comprising of 05 Nos HT VCBs of Make - Siemens - 01 No. [b] 11 KV/415 volts transformers 750 KVA - 01 No , 500 KVA - 01 No, 400 KVA - 01 No and 315 KVA - 01 No along with connected LT panel boards & changeover system. [c] HT ring main supply for both HT panels and HT feeder of Sub Stn No 5-B.
Outsourcing of services for operation and maint of power house at Sub Stn No 07 by deploying skilled electricians, technically qualified and experienced in opeartions of HT VCBs, round the clock for three shifts of 08 hours each including Sundays and holidays with 01 electrician in one shift of 08 hours, for the following :- [a] 11 KV HT VCB Panel board comprising of 03 Nos HT VCBs of Make - ABB - 01 No , 11 KV HT VCB Panel board comprising of 03 Nos HT VCBs of Make - Siemens - 01 No and 11 KV HT VCB Panel board comprising of 02 Nos HT VCBs of Make - Schneider - 01 No. [b] 11 KV/415 volts transformers 400 KVA - 01 No and 30 KVA DG Set - 01 No along with connected LT panel boards & changeover system. [c] HT ring main supply for all HT panels and four pole structure for local and other feeders.
Outsourcing of services for operation and maint of power house at WG Sub Stn by deploying skilled electricians, technically qualified and experienced in opeartions of HT VCBs, round the clock for three shifts of 08 hours each including Sundays and holidays with 01 electrician in one shift of 08 hours, for the following :- [a] 11 KV HT SF-6 RMU Panel board comprising of 1 No incoming and 02 Nos outgoing feeders of Make - ABB. [b] 11 KV/415 volts transformers 315 KVA - 02 Nos, 320 KVA DG Set - 02 No, along with connected LT panel boards & changeover system. [c] Servo controlled stablizers 315 KVA capacity along with bypass system - 02 Nos.
Outsourcing of services for operation and maint of HT installation comprising of under mentioned equipment at Sub Station No 10 (Sector-A) by deploying skilled electricians, technically qualified and experienced in opeartions of HT VCBs round the clock in three shifts of 08 hours each including Sunday and Holidays with 01 electrician in one shift of 08 hours, for the following :- [a] 11 KV HT Panel board comprising of 05 Nos VCBs of Make - ABB complete including incoming/outgoing and HT ring main control. [b] Step down transformer 11/433 volt 500 KVA-01 No and 400 KVA-01 No along with all LT panels , switch geras/ACBs/MCCBs and APFC panels etc complete.
Outsourcing of services for operation and maint of HT installation comprising of under mentioned equipment at Sub Station No 12 (Sector-B) by deploying skilled electricians, technically qualified and experienced in opeartions of HT VCBs round the clock in three shifts of 08 hours each including Sunday and Holidays with 01 electrician in one shift of 08 hours, for the following :- [a] 11 KV HT Panel board comprising of 06 Nos VCBs of Make - ABB complete including incoming/outgoing and HT ring main control. [b] Step down transformer 11KV/433 volt 315 KVA -01 No, 400 KVA-01 No along with all LT panels , switch geras/ACBs/MCCB and APFC panels etc complete.
Outsourcing of services for attending day to day complaints of external electric supply such as making the serviceability of LT/HT lines, panels after rectifying the defects of the external electric supply items such as cables, thimbles, ferrule, MCCB, Jumpers, joints, Bus bars, Main switch, Changeover, transformer, HT GODO switches, insulators, VCBs, Stabilizer etc of any make/type/size & capacity etc round the clock in three shifts of 08 hours each including Sunday and holiday complete complete all as specified and directed in Chandimandir Cantt including the areas across Kalka road, by deploying the following electricians and helpers:- [a] One electrician (Skilled) & two helpers (semi - skilled ) in each shift of 08 hours each. Note for item No 8 :- 1. The items required for the repair shall be measured and paid separately under respective items of Sch 'A' here-in-after.
2. Conveyance and necessary T&P , ladders etc for maintaing the services shall be provided by the contractor and unit rate quoted will be deemed to include the cost of the same. 3. Panelty for not attending complaint within two hours shall be recovered from contractor's dues @ Rs 200/- per compaint per hour or part thereof after two hours.
Note for item No 1 to item No 8 :- (a) If an individual detailed on shift duty is found absent or doing double shift duty, a penality of Rs 1500/- per shift will be imposed on the contractor for this lapse. (b) Contractor will submit photo copy of bank pass books/ bank account statement of the individuals employed by him showing details of salary paid to the employees before 7th of every month to Engr-In-Charge. Failing to fulfill the above mentioned condtion, no payment will be made to the contractor. (c) As per E-In-C's branch policy, salary to the staff employed by the contractor will not be made in cash under any circumstances.
Supply only dry sand for filling in the cable ducts complete all as specified and directed.
Supply only LT insulation tape ( FR PVC electrical insulation tape ) 0.125 mm thick , 1.80 cm width and 25 mtr lengthcomplete all as specified and directed. Make - Steelgrip/Anchor or as approved by GE.
Supply only HT insulation tape FR, 0.75 mm thick , 1.90 cm width and 9.0 mtr length packed in box complete all as specified and directed. Make- Kappa/3M Scotch/Gemini or as approved by GE.
Supply only copper tinned fuse wire complete all as specified and directed.
Supply only GI nuts/bolts/washers complete all as specified and directed.
Supply only MCCB 400 amps 35/36 KA four pole 415 volts 50 Hz with phase separators, adjustable thermal and magnetic release & with Ics=100% Icu complete all as specified and directed.
Supply only MCCB 320 amps 35/36 KA four pole 415 volts 50 Hz with phase separators, adjustable thermal and magnetic release & with Ics=100% Icu complete all as specified and directed.
Suplly only MCCB 250 amps 35/36 KA four pole 415 volts 50 Hz with phase separators, adjustable thermal and magnetic release & with Ics=100% Icu complete all as specified and directed.
Supply MCCB 200 amps 35/36 KA four pole 415 volts 50 Hz phase separators, adjustable thermal and magnetic release & with Ics=100% Icu complete all as specified and directed.
Supply only MCCB 630 amps 35/36 KA four pole 415 volts 50 Hz with phase separators, adjustable thermal and magnetic release & with Ics=100% Icu complete all as specified and directed.
Supply only on load type changeover switch without enclosure 630 amps capacity four pole 415 volts complete all as specified and directed.
Supply only on load type changeover switch without enclosure 800 amps capacity four pole 415 volts complete all as specified and directed.
Supply only LED Flood Light luminaire of capacity 120 Watt,system lumen efficacy not less than 90 lumen per watt, total system lumens not less than 10800 lumens, PF>0.90 ,CRI not less than 70, THD not more than 10 %, surge protection not less than 5 KV, colour temp 5700 k to 6500k, operating voltage ranging from 120V to 270 V at 50 Hz AC frequency,Pressure die cast aluminium housing in powder coated finish , heat resistant toughened glass , gasket etc ,luminaire IP 65 Class -I complete all as specified and directed.
Supply only high power LED street light fittings energy saving luminaire with lens , capacity 60 watt with system efficacy (lm/w) not less than 90 lumens per watt, total system lumen not less than 5400 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5000K TO 6500 K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housing IP-65/66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% complete all as specified and directed.
Supply only log sheets for sub stations printed on both sides on legal size paper all as per sample complete all as specified.
Supply only shock treatment chart (English and Hindi/punjabi) duly framed with 6 mm ply base and 25 mm thick wooden/PVC frame with transparent PVC sheet not less than 3 mm thickness on front side with wall hanging arrangement complete all as specified and directed.
Supply only dress along with name plate for electricians (Comprising of shirt, trousers, shoes, socks and safety gears) duly stiched as per required size complete all as specified and directed.
Note :- (a) Colour and pattern of the dress shall be approved by GE(U). Two sets of dress one each for summer and winter shall be provided to each operator during currency of the contract. (b) If any individual employed by the contractor is found without wearing proper dress during duty hours a penality of Rs 500/- per shift or part thereof will be imposed.
Supply only RCBO 32-40 amps 2 module 100 ma 230 volts 50 Hz ISI marked
Supply only low voltage + over voltage release 230 volts SP in one module suitable for 1 P + 1 N complete all as specified and directed.
Supply only LED lamp invertor technology 9 watt with 4 hours back up with efficiency more than 100 lumens per watt with litheum ion battery complete all as specified and directed.
Supply only LED 20-22 watt integrated batten with inbuilt Litheum ion battery , with efficiency more than 100 lumens per watt ,with min 04 hours back up complete all as specified and directed. Make :- Hallonix/Philips/Syska or equivalent of any make mentioned in Appx B.
Supply only suspended extruded aluminium decorative micro fixture powder coated 15 watt in black colour having system lumens more than 100 lumens per watt having THD more than 10 %, PF not less than 0.95. Make :- Hallonix/Philips/Syska/WIPRO or equivalent of any make mentioned in Appx B.
Supply only cotton waste complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 16 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 25 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 35 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 50 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 70 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 95 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 120 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 150 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 185 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 240 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 300 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 400 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs reducer type of size 16 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs reducer type of size 25 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs reducer type of size 35 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs reducer type of size 50 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs reducer type of size 70 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs reducer type of size 95 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs reducer type of size 120 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs reducer type of size 150 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs reducer type of size 185 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs reducer type of size 240 sqmm complete all as specified and directed.
Supply only heavy duty aluminium lugs reducer type of size 300 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 16 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 25 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 35 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 50 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 70 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 95 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 120 sqmmcomplete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 150 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 185 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 240 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 300 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 400 sqmm complete all as specified and directed.
Supply only CRC 2-26 power spray 500 ml bottle complete all as specified and directed.
Supply only ACSR conductor complete all as specified and directed.
Supply only HT outdoor type heat shrinkable end termination kit suitable for 11000 volts (earthed) HT cable of size 70 - 95 sqmm 3 core complete all as specified and directed.
Supply only HT outdoor type heat shrinkable end termination kit suitable for 11000 volts (earthed) HT cable of size 120 - 185 sqmm 3 core complete all as specified and directed.
Supply only HT outdoor type heat shrinkable end termination kit suitable for 11000 volts (earthed) HT cable of size 240 sqmm 3 core complete all as specified and directed.
Supply only HT indoor type heat shrinkable end termination kit suitable for 11000 volts (earthed) HT cable of size 70 - 95 sqmm 3 core complete all as specified and directed.
Supply only HT indoor type heat shrinkable end termination kit suitable for 11000 volts (earthed) HT cable of size 120 - 185 sqmm 3 core complete all as specified and directed.
Supply only HT indoor type heat shrinkable end termination kit suitable for 11000 volts (earthed) HT cable of size 240 sqmm 3 core complete all as specified and directed.
Supply only HT straight through type heat shrinkable jointing kit suitable for 11000 volts (earthed) HT cable of size 70 - 95 sqmm 3 core complete all as specified and directed.
Supply only HT straight trough type heat shrinkable jointing kit suitable for 11000 volts (earthed) HT cable of size 120 - 185 sqmm 3 core complete all as specified and directed.
Supply only HT straight through type heat shrinkable jointing kit suitable for 11000 volts (earthed) HT cable of size 240 sqmm 3 core complete all as specified and directed.
Supply only straight through joint epoxy type for XLPE insulated armoured 1100 volt grade aluminium conductor cable of size 25 sqmm 3.5 core to 35 sqmm 3.5 core complete all as specified and directed.
Supply only straight through joint epoxy type for XLPE insulated armoured 1100 volt grade aluminium conductor cable of size 50 sqmm 3.5 core complete all as specified and directed.
Supply only straight through joint epoxy type for XLPE insulated armoured 1100 volt grade aluminium conductor cable of size 70 sqmm 3.5 core complete all as specified and directed.
Supply only straight through joint epoxy type for XLPE insulated armoured 1100 volt grade aluminium conductor cable of size 95 sqmm 3.5 core complete all as specified and directed.
Supply only straight through joint epoxy type for XLPE insulated armoured 1100 volt grade aluminium conductor cable of size 120 sqmm 3.5 core to 150 sqmm 3.5 core complete all as specified and directed.
Supply only straight through joint epoxy type for XLPE insulated armoured 1100 volt grade aluminium conductor cable of size 185 sqmm 3.5 core complete all as specified and directed.
Supply only straight through joint epoxy type for XLPE insulated armoured 1100 volt grade aluminium conductor cable of size 240 sqmm 3.5 core complete all as specified and directed.
Supply only straight through joint epoxy type for XLPE insulated armoured 1100 volt grade aluminium conductor cable of size 400 sqmm 3.5 core complete all as specified and directed.
Supply only service cable cables insulated, PVC sheathed aluminium conductors multistranded heavy duty 1100 Volt grade cross sectional area 10 sqmm 2 core. (100 mtr roll) complete all as specified and directed.
Supply only MCCB 400 amps 35 KA TP 415 volts 50 Hz with phase separators, adjustable thermal and magnetic release & with Ics=100% Icu complete all as specified and directed.
Supply only MCCB 250 amps 35 KA TP 415 volts 50 Hz with phase separators, adjustable thermal and magnetic release & with Ics=100% Icu complete all as specified and directed.
Supply only MCCB 100 amps 25 KA TP 415 volts 50 Hz with phase separators, adjustable thermal and magnetic release & with Ics=100% Icu complete all as specified and directed.
Supply only MCCB 63 amps 25 KA TP 415 volts 50 Hz with phase separators, adjustable thermal and magnetic release & with Ics=100% Icu complete all as specified and directed.
Supply only spiral type PVC line spacers with spacer rod dia 13 mm suitable for 5 lines complete all as specified and directed.
Supply only spiral type PVC line spacers with spacer rod dia 13 mm suitable for 4 lines complete all as specified and directed.
Supply only wall mounting indoor type 200 amps capacity 8 way TPN busbar chamber 415 volts in sheet steel enclosure complete all as directed. Make:- Havells or equivalent make mentioned in Appx B.
Supply only switch disconnector fuse unit in sheet steel enclosure capacity 400 amps TPN 415 volts with and including HRC fuses complte all as directed. Make:- C&S/L&T/Havells or equivalent make mentioned in Appx B.
Supply only electrical panel doors fabricated from MS sheet as per existing size and shape and fixed with hinges by properly welding and checking for proper closing and opening complete all as specified and directed.
Refixing only existing panel doors by welding the hinges with panel body properly and fixing the panel door with hinges by welding or as per existing arrangements and checking for proper opening and closing of the door all as specified and directed.
Note:- Reparing and refixing of one door panel fitted with 2/3 hinges shall be considered as one job. Any small piece of MS sheet of thickness 2/3 mm required for repairing the portion of the door to be fixed with hinges and replacing any damaged MS hinge shall be deemed to be included in the unit rate quoted.
Supply only first aid kit as per sample or complete all as specified and directed.
Supply of feeder pillar / Distribution Boards: Thermoplastic Polycarbonate IP 65 in accordance with EN 60 529, Dust Proof, Water Proof & Weatherproof, Metering panel (1.10 X1.875 X 0.60m), Shock proof, Rust Proof, Corrosion Free, Acid & Chemical Resistant, Fire Retardant & Self Extinguishing, UV Resistant, Silica and Halogen Free recyclable material, Glow wire tested at 960°C in accordance with IEC 60 695-2-11. Type tested as per IEC 60 439-1. Total Insulated with System. The manufacturer of board/panel shall submit a copy of CPRI test report of Degree of Ingress Protection IP 65 in accordance with IEC 60529. The gasket material shall be Polyurethane; while the gasket shall be internally embedded. The manufacturer of
board / panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The report shall mention the following tests performed and passed out satisfactorily:- (a) Degree of Protection. (b) Temperature Rise. (c) Dielectric Properties. (d) Short circuit withstand current – Rated peak & short time withstand current and rated Conditional Short Circuit Current. (e) Effectiveness of Protective Circuits. (f) Clearance & Creepage Distance. (g) Mechanical Operation.
Polycarbonate enclosure shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It shall be tested at Glow Wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. The lid closing and opening shall be done by quick fastening spring mechanism latches. Suitable accessories for armoured cable shall be supplied with the panel; these accessories shall not be fitted with screws, so that there is no loss of IP, but should be auto fit. The board manufacturer shall submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Each Board shall have individual routine test report of the manufacturer & will have the following accessories :-
(a) 4 Nos heat shrink insulated bus bar of 600 Amps rating including all connection with aluminium strip. (b) Incomer:MCCB four pole 415 Volts 50 Hz 400 Amps 35 KA adjustable thermal & adjustable megnetic settings and Ics=100% Icu - 01 No. (c) Outgoing MCCB TP 415 25KA of rating 100 amps adjustable thermal and adjustable magnetic setting and Ics=100% Icu mounted on din rail including connection from main busbar to MCCB with aluminium busbar strips of suitable current ratings-02 No and MCCB TP 415 25KA of rating 160 amps adjustable thermal and adjustable magnetic setting and Ics=100% Icu mounted on din rail including connection from main busbar to MCCB with aluminium busbar strips of suitable current ratings-02 No. Make of Panel - Hensel/Siemens/GE Power/ABB/Universal/Legrand
Vee Vee Enterprises
Bharat Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .