Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAccepted-AOC | ₹3.0 Cr Quoted ₹3.1 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹3.1 CrRejected-AOC 44 TARUN NAGAR GUWAHHATI P O CHRISTIAN BASTI PS BHANGAGARH KAMRUP METRO PIN 781005 | KAMRUP METRO | ASSAM | 781005 | ₹3.1 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹3.3 CrRejected-AOC CHATRIBARI ROAD KRISHNA NAGAR GUWAHATI 1 ASSAM | KAMRUP METRO | ASSAM | 781001 | ₹3.3 Cr | L3 | Rejected-AOC L3 |
| 4 | L4₹3.4 CrRejected-AOC | ₹3.4 Cr | L4 | Rejected-AOC L4 |
| 5 | L5₹3.5 CrRejected-AOC RNB ROAD KOKRAJHAR ASSAM | KOKRAJHAR | ASSAM | 783331 | ₹3.5 Cr | L5 | Rejected-AOC L5 |
Tender Value
₹4.7 Cr
EMD Value
₹9.3 L
Closing Date
31 Oct 2022, 2:00 pmClosed
CE PWD NH Works Assam, Chandmari, Guwahati-781003
O/O The CE PWD NH Works Assam, Chandmari, Guwahati-781003
Up - gradation and Improvement of Street Lighting Facilities of Jalukbari - Airport Borjhar Road (At National Highway No. - 17 ) in Guwahati under SOPD for the year 2022-23
2022_PWBNH_27340_1
NHR (R) / GHY/ SOPD(Elect.) /2022-23/01
Open Tender
Civil Works – Highways
180 days
Borjhar
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,330
₹9.3 L
O/O The CE PWD NH Works Assam, Chandmari, Ghy-3
19 May 2023
12 Oct 2022
31 Oct 2022
12 Oct 2022
31 Oct 2022
12 Oct 2022
20 Oct 2022
Amount
Providing and Installation of LED Street Light 90 Watts in the Existing Pole with necessary Wiring with 3 Core 1.50 Sq.mm Sheathed Cable from Pole Junction Box to Light (Philips / Crompton / Bajaj / LT / Jaquar Make). GENERAL SPECIFICATION LED Rating (In Watts) / System Wattage / Rated Power - 90 Watts. Luminaire System Effi Cacy (Lumen / Watts) :>/= 100 Lm / Watt. Ingress Protection (IP Rating) as per IS : 10322 (Part - 1) : 1982 Latest : IP 66. Warrantry for Free Replacement (In Years) : 5. Input Operating Voltage Range : 140 to 270 Volts AC. MORE STANDARDS LED Luminaire Conformity to IS : 10322 / Pat - 5 / Section - 3 / 2012 Latest and IS : 16107 (Part - 2 / Sec - 1) : 2012 Latest Yes. Photo Biological Safety of LEDs used shall be as per IS : 16108 / 2012 (Exempt Group) Yes. Types of LED Luminaire as per IS : 16107 (Part - 2 / Sec - 1) / 2012 Type - B. Types of LED Modules as per IS : 16103 (Part - 2) / 2012 Type - 3. ELECTRICAL EFFICIENCY Automatic Higher Cut Off Voltage above 300 Volts Yes Rated Voltage 230 Volts AC 50 Hz. AC Power Factor at Full Load ≥ 0.95. Driver Efficiency(in%age)Upto 100W:≥85%,Above 100W>/=90% Yes. Total Harmonics Distortion ≤10 .The total circuit powershall not be more than 110 percent of the value declared by themanufacturer(as per CI:8 of IS :16104 :2012 lates) yes. OPTICAL LED chip Effi cassy ≥130 Lm/Watt. Colour temperature 6000+/-500K.Working life for LED(Minimum 50,000 buming hours as per LM-80 and LM21 reports)Yes.
Supplying including Installation of the Octagonal Poles shall be Designed to withstand the Maximum Wind Speed of 169 KM / Hrs. The Top Loading i.e. Area and Weight of Fixtures are to be considered to Calculate maximum deflection of the Poles and the same shall meet the requirement of BS : 5649 Part - VI 1982. The Pole shaft shall have Octagonal Cross Section and shall be continously tapered with single longitudinal welding. There shall not be any circumferential welding of the Pole shaft. The welding of the Pole shaft shall be done by Submerged Welding Process. All Octagonal Pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The base plate shall be filled welded to the Pole shaft at two location i.e. from inside and outside. The welding shall be done as per process approved by Third Party Inspection agency. (BAJAJ / PHILIPS / VALMONT / PARUTHI ENGR / Nezone Make) Pole Type BOP or equlvalent - 7030 Height 7 M The materials of the Pole as follows : Conforming to grade S355JO, Base Plate Fe 41O Conforming to IS 226 / IS 2062, Foundation Bolts :- 6.8 Gr. As per IS
Providing Arm Bracket 1 M and fixing it at existing Pole design etc as approved by this Deptt. b) Double Arm.
Providing Arm Bracket 1 M and fixing it at existing Pole design etc as approved by this Deptt. a) Single Arm.
b) Triple Arm.
Earthing with G.I. Earth Pipe 4.5 Metre Long, 40 MM Dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
Providing and fixing 6 SWG Dia G.I. Wire on surface or in recess for loop earthing as required.
Erection of Steel Tubular or Rail Pole strut in cement concrete 1 : 3 : 6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts etc. as required.
Erection of RCC / PCC Pole of following length in brick ballast and ramming the foundation, finishing with 150 mm thick cement concrete (1 : 3 : 6) layer on top with including excavation and refilling etc. as required. Above 8.0 Meters and upto 11.0 Meters.
Supply of PSC Pole 9.75 Meters.
Supply of Cable 6.00 Sq.mm 4 Core Alliminium RR Kabel / Finolex / Gloster Make including storing intil laying.
Supply of Cable 16.00 Sq.mm 4 Core Alliminium RR Kabel / Finolex / Gloster Make including storing intil laying.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35.00 Sq.mm.
Above 35.00 Sq.mm and upto 95.00 Sq.mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC / HUME / METAL Pipe as required. Upto 35.00 Sq.mm.
Above 35.00 Sq.mm and upto 95.00 Sq.mm.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required. Upto 35.00 Sq.mm.
Above 35.00 Sq.mm and upto 95.00 Sq.mm.
Providing, laying and fixing following Dia G.I. Pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required. 50 MM Dia
80 MM Dia.
100 MM Dia.
150 MM Dia.
Supplying including ITC of Ready made Street Light Timer panel No. of phase Three Power rating / indicative current rating for relay on 230 V basis and 0.6 PF 3 Phase, 18 kW / 43 A each phase System Rated Voltage (+/- 10 %) 440 Volt, 50Hz IP Rating IP 54 Manually settable timer with 12 programmes spreaded over a year as defined programme Yes Manual ON / OFF Yes Intermediate ON - OFF Yes ON / OFF Timing accuracy </= 60 seconds GENERIC ATSC is an intelligents Street light control timer that can be used to control serveral existing street Light units Yes Network / Communication support through GPRS and With GPS NO Each ATSC has built in networking support that communicates to the central server that can control each phase independently and log the performance of all or a cluster of street lights (If" NO" write NA) NA Built in feature Astronomical timer Yes ATSC shall display of Longitude, Latitude, Date, Time, Voltage, Current and On time and Off time Yes Display of Energy in Kwh and Measurement of energy (in kWh) (non uttility) with resolution 1% Yes PROTECTION Over Voltage Protection per phase 260 Volt +/- 5 Volt Under Voltage Protection per phase 160 Volt +/- 5 Volt
Supplying Junction Box Polycarbonate / PVC weatherproof 300 x 300 x 175 mm (Hensel / Syntex Make) at existing Pole with Clamp etc.
Painting with alluminium paint of approved brand and manufacture to give an even shade, Two or more coats on new work.
Supplying and fixing 5 A to 32 A rating, 240 / 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole.
Supplying and fixing following rating, four pole, 415 V Isolator in the existing MCB DB complete with connections, testing and commisioning etc. as required. 40 Amps.
Providing Service Connection charge to be paid to APDCL authority for including load security (@2 5 kW for 2 Nos of Connection).
Providing 3P 4W ICS DLMS compliant whole current energy meter, 3 x 240 V phase to neutral, 5 - 30 A Class 1.0 with pilfer proof box for consumer metering.
Supply including Installation Testing Commissioning of High Mast Lighting Octagonal Tower with integrated all in One Solar Led Street Light, Onsite warranty 3 Years Height of Octagonal pole : 10 meters No. of integrated Solar LED Street Light (can be fitted in of each octagonal pole) : 6 Thickness of Octagonal Pole Sheet : 3 milli meter Thickness of Base Plate : 16 milli meter Width of Base Plate : 300 milli meter Length of Base Plate : 300 milli meter Regional wind withstand : 55 m / s Generic Height of Octagonal pole 10 meters Lightning Type integrated Solar Street Light Octagonal Pole Desighning, Engineering, Fabrication and testining before despatch with required height and required No. of Light fittings with luminaire carriage etc. for illumination of open areas) Yes No. of Integrated Solar LED Street Light (can be fitted in of each octagonal pole) 6 Octagonal Pole Construction Metal protectiontreatment of fabircatedmast section Hot dip Galvanised as per IS : 4759 latest PRODUCT COMPARE PRODUCT HISTORY 4 Ask GeMmy
Supplying including Installation of the Octagonal Poles shall be Designed to withstand the Maximum Wind Speed of 169 KM / Hrs. The Top Loading i.e. Area and Weight of Fixtures are to be considered to Calculate maximum deflection of the Poles and the same shall meet the requirement of BS : 5649 Part - VI 1982. The Pole shaft shall have Octagonal Cross Section and shall be continously tapered with single longitudinal welding. There shall not be any circumferential welding of the Pole shaft. The welding of the Pole shaft shall be done by Submerged Welding Process. All Octagonal Pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The base plate shall be filled welded to the Pole shaft at two location i.e. from inside and outside. The welding shall be done as per process approved by Third Party Inspection agency. (BAJAJ / PHILIPS / VALMONT / PARUTHI ENGR / Nezone Make) Pole Type BOP or equlvalent - 1030 Height 10 M The materials of the Pole as follows : Conforming to grade S355JO, Base Plate Fe 41O Conforming to IS 226 / IS 2062, Foundation Bolts :- 6.8 Gr. As per IS
Supply of Cable 6.00 Sq.mm 4 Core Alliminium RR Kabel / Finolex / Gloster Make including storing untill laying.
Supply of Cable 10.00 Sq.mm 4 Core Alliminium RR Kabel / Finolex / Gloster Make including storing untill laying.
Supply of Cable 16.00 Sq.mm 4 Core Alliminium RR Kabel / Finolex / Gloster Make including storing untill laying.
Supply of Cable 70.00 Sq.mm 3.5 Core Alliminium RR Kabel / Finolex / Gloster Make including storing untill laying.
Supplying and making Indoor end termination with brass compression gland and aluminium lugs for following size of PVC Insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 50.00 Sq.mm (35 MM).
3.5 x 35.00 Sq.mm (32 MM).
Supplying and Laying of following Size DWC HDPE Pipe ISI Marked along with all Accessories like Socket, Bend, Couplers etc. Conforming to IS – 14930, Part – II complete with Fitting and Cutting, Jointing etc. direct in Ground (75 CM Below Ground Level) including Excavation and Refilling the Trench but Excluding Sand Cushioning and Protective Covering etc. complete as Required. 90 MM Dia (OD – 90 MM and ID – 76 MM Nominal).
Supplying and fixing following rating, four pole, 415 V Isolator in the existing MCB DB complete with connections, testing and commisioning etc. as required. 100 Amps.
Supplying, Installation, Testing and Commissioning of 33 K.V. / 0.433 K.V. or 11 K.V. / 0.433 K.V. Sub - Station Equipments Comprising H.T. Panel, Dry Type Transformer, H.T. Cable, Bus Trunking from Transformer to L.T. Pnael, L.T. Panel, Automatic Power Factor Correction Panel, Active Harmonic Filters, TVSS (Transient Voltage Suppression System), SPD (Surge Protection System), Essential Panel, Earthing, Required Inter - Connections, Sub - Station Safety Equipments including L.T. Cabling from Sub - Station to the Building Fed by the Sub - Station.(25kVA for 2 Nos of Connection)
Providing Service Connection Disconnection charge to be paid to APDCL authority.
Providing and Installation of LED Street Light 70 Watts in the Existing Pole with necessary Wiring with 3 Core 1.50 Sq.mm Sheathed Cable from Pole Junction Box to Light (Philips / Crompton / Bajaj / LT / Jaquar Make). GENERAL SPECIFICATION LED Rating (In Watts) / System Wattage / Rated Power - 70 Watts. Luminaire System Efficacy (Lumen / Watts) :>/= 100 Lm / Watt. Ingress Protection (IP Rating) as per IS : 10322 (Part - 1) : 1982 Latest : IP 66. Warrantry for Free Replacement (In Years) : 2. LED Luminaire Confirmity to IS : 10322 / Part - 5 / Section - 3 / 2012 Latest and IS - 16107 (Part - 2 / Section - 1) : 2012 Latest Yes. Photo Biologicall Safety of LEDs used shall be as per IS : 16108 / 2012 (Exempt Group) Yes. Types of LED Lumanaire as per IS : 16107 (Part - 2 / Section - 1) / 2012 Type B Type of LED Modules as per IS : 16103 (Part - 2 / 2012) Type 3. LED Rating (In Watts) / System Wattage / Rated Power 70 Watts. Luminaire System Efficacy (Lumen / Watt) >/= 100 Lumen / Watt. Ingress Protection (IP Rating) as per IS : 10322 (Part - 1) : 1982 Latest IP - 66. Warrenty for Free Replacement (In Years) 2. ELECTRICAL EFFICIENCY Input Operating Voltage Range and Frequency 90 to 300 Volts AC at 50 Hz +/- 2. Autamatic Higher Cut off Voltage above 300 Volts Yes. Rated Voltage 230 Volts AC 50 Hz. AC Power Factor at Full Load ≥ 0.95 Driver Efficiency (In Percentage) upto 100 Watts ≥ 85 %, Above 100 Watts : >/= 90 % Yes. Total Harmonics Distortion ≤ 10 *The Total Circuit Power shall not be more than 110 Percent of the Value Decleared by the Manufacturer (As per Clause 8 of IS : 16104 / 2012 Latest)* Yes. OPTICAL LED Chip Efficiency ≥ 130 Lm / Watt. Colour Temperature 6000 +/- 500 K
Comprehensive & Preventive Annual Maintenance Contract for 1st Year including labour for operation of switchgear 3 % of Installation cost of Light fixtures, Cables and Swltchgears.
Comprehensive & Preventive Annual Maintenance Contract for 2nd Year including labour for operation of switchgear 4 % of Installation cost of Light fixtures, Cables and Swltchgears).
Comprehensive & Preventive Annual Maintenance Contract for 3rd Year including labour for operation of switchgear 5 % of Installation cost of Light fixtures, Cables and Swltchgears).
Comprehensive & Preventive Annual Maintenance Contract for 4th Year including labour for operation of switchgear 6 % of Installation cost of Light fixtures, Cables and Swltchgears).
Comprehensive & Preventive Annual Maintenance Contract for 5th Year including labour for operation of switchgear 7 % of Installation cost of Light fixtures, Cables and Swltchgears).
Buy Back / Salvage value of dismantled Solar Battery + Solar panel + LED 45 watt DC Light + GI Brackets. Dismantling and clearing from site will be under the scope of tenderer.
VERSHA TECHNOTRADE PVT LTD
Assam Supply Syndicate
Assam Electricals
M/S Assam Electric Store
Industrial Systems LLP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid