Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.9 LAccepted-AOC | ₹57.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹59.6 LRejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹59.6 L | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹61.1 LRejected-Finance | ₹61.1 L | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹66.6 LRejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | ₹66.6 L | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹70.5 LRejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹70.5 L | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | Electromech Engineers L4 | CHINAR CONSTRUCTION TRADERS L1 | M/S MARSHAL TRADERS L3 | vijay kumar gupta and co L5 | ANIKET TRADERS L2 | M/s Nasir Rasool Dar L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of copper wound HT 11 KV AVR (Automatic Voltage regulator) suitable for outdoor installation of capacity 1500 KVA, 3 Phase,50 Hz, HV input voltage of 7 KV to 12 KV, HV output voltage 11 KV (+ or -) 1% with the following Specifications.
(A) Ratings Input/Output :-
(i)Type of cooling : ONAN
(ii) Rated Voltage : 11 KV
(iii) Input Voltage Range : 7 KV to 12 KV
(iv) Input Current in Amps : 123.72 A to 72.17 A
(v) Output Voltage in Amps : 11 KV + or -1%
(vi) Output Current in Amps : 78.73A | 1 | Each | 61,93,000 ₹61.9 L | 55,25,000 ₹55.3 L | 55,55,555 ₹55.6 L | 68,00,000 ₹68 L | 56,99,999 ₹57.0 L | 67,00,000 ₹67 L |
| 1.01(B) Type :- Suitable for balance supply and Unbalanced load. (C) Supply for Control unit :- Single phase 230 Volts, 50 Hz AC from self source. (D) Rate of Correction :- 10 Volt/Sec (E) Impedance at 11 KV :- 4 to 5% (F) Efficiency: AT FULL LOAD 95%. (G) Duty Cycle :- 100% Continuous (H) Suitability :- Suitable for all Power factor (J) Winding :- Copper wound, HV & LV, Electrolytie copper, Uniformly insulated. (K) Type of Regulator :- (i) Roller contact type vertical Regulator. (ii) Auto wound with double wound buck boost Transformer with Automatic control gear consisting of electronic relay. (iii) Reversing gear motor unit. (iv) Limit switch for Highest & Lowest position (v) Chain Drive. (vi) Coupling device and control panel with all electrical connection. (L) Tapping :- ON-Load step less linear rolling Contact type regulator. (M) INDICATIONS: Input On, Input Low, Input High, Output Cut Off (N) CORE LAMINATIONS: Type : CRGO, Material : Silicon, Steel Lamination, Thickness : 0.3 | |||||||||
| 1.02(O) Terminal Bushing Minimum Clearance in Air :11 KV Phase to Phase : 200mm 11 KV, Phase to Ground : 385mm, Minimum Creepage Distance : 385mm with oil filling hole with cap & drain plug with extension of pipe.Detachable radiator with shut off valve, Oil level gauge with 3 position, Filter valve 25mmsize, Air release valve, Rating & terminal marking plate, Weather proof. (P) Test Required : (i)Routine Test, All routine test as per IS : 2026, Oil Pressure & Vacuum with stand test : 7 PSI, Colour shade : D.A.Gary. (ii) Insulation with stand : 28 KV for 1 Minute. (Q) Fittings would include:- (i) Rating & Diagram Plate (ii) Silica gel breather (iii) Earthing Terminals. (iv) Lifting lugs (v) Drain valve (vi) Air Release plug (vii) Oil level indicator (Viii) Filter valve (ix) Pressure Relief Valve (x) O.T.I. | |||||||||
| 1.03(R) GENERAL FEATURES: (i) HAND CONTROL: Hand wheel will be located on the front of the Regulator tank at convenient operative height. (ii) MOTOR CONTROL: Raise / Lower push button control by means of small single phase reversible geared motor of permanent capacitor type will be provided. Limit switches will be fitted to restrict the travel at extreme positions. With this arrangement, it would also be possible to provide remote control to the Regulating Unit. The reversible geared motor would be of ‘Step-Syn’ type. (iii) AUTOMATIC CONTROL: For automatic correction of fluctuating supply voltage, we shall provide Electronic Relay which in its simplest form, senses the Output Voltage and provide signal to the driving motor for necessary correction. (S) Temperature :- (i) Average Ambient Temp : 45 Degree C. (ii) Top oil temperature rise : 50 Degree C above ambient. (iii) Winding Temp rise : 55 Degree C above ambien. Note :- The Contractor shall get approval of design & drawing of equipements from Accepting Officer before procurement of equipements. (ii) Foundation of AVR as per OEM recommendation. (iii) The cost of foundation Exclusive in the item rate. | |||||||||
| 2.00 | Supply, laying, jointing, commissioning & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable, heavy duty (earthed) with aluminium conductor, 11000 volts grade, cross sectional area 95 Sqmm 3 Core, laid in trenches/ floor/ duct/ fixed on poles/ through GI tubing, complete all as specified and directed.
Note :-
(a) Excavation, earth work, sand cushioning and PCC cable covers will be measured and paid separately under respective items of this BOQ.
(b) Cable shall be tested after laying/ fixing and rates for the shall be deemed to included in the quoted rates. | 80 | RM | 1,360 ₹1.1 L | 700 ₹56,000 | 1,455 ₹1.2 L | 900 ₹72,000 | 990 ₹79,200 | 1,200 ₹96,000 |
| 3.00 | M&L cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, complete all as specified and directed. | 6 | Each | 6,600 ₹39,600 | 3,000 ₹18,000 | 6,500 ₹39,000 | 4,000 ₹24,000 | 2,200 ₹13,200 | 8,000 ₹48,000 |
| 4.00 | M&L earthing complete with copper earth plate electrode of size 600x600x3.15mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below from normal ground level), connecting to the copper earth strip of size 20x3mm by means of bolts, nuts, check nuts and washers of galvanised iron and earth lead protected by 40mm bore GI pipe, light grade including provision of conrete pit PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) with 40mm thick cover of RCC (1:2:4) type B-1, reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x3mm and with 6mm dia MS bar handle, made to shape, 20mm bore GI light grade pipe for watering pipe, placed on top edge of earth plate and including common salt and charcoal filling, test point with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtr, complete as per electrical plate No. 3 of MES SSR Part-I (2009), complete all as specified and directed.
Note :- The earthing will be tested after completion, if desire results not achieved, the contractor shall redo the earthing and rates for the same shall be deemed to included in the quoted rates. | 4 | Each | 45,000 ₹1.8 L | 18,000 ₹72,000 | 35,000 ₹1.4 L | 20,000 ₹80,000 | 22,000 ₹88,000 | 30,000 ₹1.2 L |
| 5.00 | M&L plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggragate) as in foundation, filling in etc., complete all as specified and directed. | 4 | Cum | 5,650 ₹22,600 | 5,000 ₹20,000 | 5,500 ₹22,000 | 2,000 ₹8,000 | 2,000 ₹8,000 | 3,000 ₹12,000 |
| 6.00 | M&L cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in copings, kneelers, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating form work, complete all as specified and directed. | 7 | Cum | 7,500 ₹52,500 | 9,000 ₹63,000 | 6,000 ₹42,000 | 2,500 ₹17,500 | 3,000 ₹21,000 | 8,000 ₹56,000 |
| 7.00 | M&L brick work with sub class 'B' bricks, old size, straight or curved on plan exceeding 6 Mtr mean radius, built in cement mortar 1:6, complete all as specified and directed. | 5 | Cum | 7,500 ₹37,500 | 5,000 ₹25,000 | 8,000 ₹40,000 | 6,000 ₹30,000 | 6,600 ₹33,000 | 8,000 ₹40,000 |
Updated dates
Tender Value
₹67.8 L
EMD Value
₹1.3 L
Closing Date
10 Feb 2026, 6:00 pmClosed
Col P Canon Anal CWE
HQ 134 Wks Engrs PIN - 914134 C/o 56 APO
Provn of 1.5 MVA HT Automatic Voltage Regulator with connected works at 33/11 KV MRS of JAK LI RC under GE 970 EWS
2026_MES_748033_1
134WE-99(T)/2025-26
Open Tender
Civil Works - Others
180 days
GE 970 EWS
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE 970 EWS
₹1.3 L
24 Feb 2026
10 Jan 2026
12 Feb 2026
10 Jan 2026
10 Feb 2026
27 Jan 2026
10 Jan 2026 - 17 Jan 2026
Supply, installation, testing and commissioning of copper wound HT, AVR suitable for outdoor installation of capacity 1500 KVA, suitable outdoor HV input voltage range of 7 KV to 12 KV, HV output voltage 11 KV (+/-) 1% with the following all standard fittings, such as silica gel breather, temperature gauge, bucholz relay, WTI & OTI trip & alarm including by pass connections with all control cables of appropriate rating technical specifications of HT AVR, complete with the followings :- (A) RATINGS :- Rating in KVA : 1500 KVA, Number of phases & Frequency : 3 Phase 50 Hz. Type of cooling : ONAN, Rated Voltage : 11 KV, Input Voltage Range : 7 KV to 12 KV, Input Current Range : 123.72 Amp to 72.17 Amp, Output Voltage : 11 KV +1% Output Current : 78.73Amp, Correction Rate : KV/ Second : 50V/Sec, Operating frequency : 50 HZ, Duty Cycle : 100% Continuous Load, Type of Load : More than 99%, Guaranteed Over-all efficiency : 98.65%, Winding : Electrolytic grade copper purity 99.08% IMPEDANCE : 1.95%,
(L) TERMINATION ARRANGEMENT :- H.V SIDE (CABLE BOX) : Auxiliary L.V. (Cable box), Disconnecting Chambers for HT, Conservator with oil filling hole with cap & drain plug with extension of pipe. Detachable radiator with shut off valve, Oil level gauge with 3 position, Filter valve 25mm size, Air release valve, Rating & terminal marking plate, Weather proof Marshaling box with connection for above auxiliary protection with Lamp holder with Switch. (M) Miscellaneous :- Test Required : Routine Test, All routine test as per IS : 2026, Oil Pressure & Vacuum with stand test : 7 PSI, Colour shade : D.A.Gary. (N) GENERAL ARRANGEMENT :- The unit consists of following :- (i) Stepdown Transformer- Double wound Delta/Star connected. (ii) ‘ON’ Load Voltage Regulator, Auto wound Delta connected. (iii) Buck-Boost Transformer, Double wound, open/open connected. (iv) Automatic control gear consisting of :- One Electronic Voltage Relay, One Reversing Stepsyn type geared motor unit, Two limit switches in order to avoid over running highest and lowest positions, chain drive, coupling device and all electrical connection.
(O) CONSTRUCTION :- The items N (i) & N (iii) above will be housed inside a well ventilated sheet steel tank and mounted on feet and items shall be supplied with first filing of oil, fittings would include :- (i) Rating & Diagram Plate (ii) Silica gel breather (iii) Earthing Terminals (iv) Lifting lugs (v) Drain valve (vi) Air Release plug (vii) Oil Conservator with Oil level indicator (viii) Filter valve (ix) Pressure Relief Valve (x) W.T.I. & O.T.I (xi) Buchholz Relay (P) GENERAL FEATURES :- (i) HAND CONTROL :- Hand wheel will be located on the front of the Regulator tank at convenient operative height. (ii) MOTOR CONTROL :- Raise / Lower push button control by means of small single phase reversible geared motor of permanent capacitor type will be provided. Limit switches will be fitted to restrict the travel at extreme positions. With this arrangement, it would also be possible to provide remote control to the Regulating Unit. The reversible geared motor would be of ‘Step-Syn’ type. (iii) AUTOMATIC CONTROL :- For automatic correction of fluctuating supply voltage, we shall provide Electronic Relay which in its simplest form, senses the Output Voltage and provide signal to the driving motor for necessary correction. Note :- The contractor shall get approval of design & drawings of equipment(s) from Accepting Officer before procurement of equipment(s).
(e) Conductor cable as per manufacturer's instructions as required at site-01 Job. (f) The contractor shall submit a type test certificate to the Engr-in-charge / GE for approval before placing the order. Conditions:- The switchboards shall be designed to operate under site conditions as specified in the datasheets. If not specifically mentioned therein, a design ambient temperature range upto +40°C and an altitude not exceeding 1652 meters above mean sea level shall be considered. (i) All openings, covers, and doors shall be provided with suitable gaskets around the perimeter to make the switchboard dust and vermin proof. (ii) Each unit of the switchgear shall have necessary internal sheet metal barriers to form separate compartments for circuit breakers, busbars, instruments and relays, cable connections, etc. Compartments for cable connections shall allow cable termination and connection work with the switchgear energized. A suitable interlock shall be provided such that the cable compartment can be opened only when the earth switch is ON or Earthing truck is inserted. (iii) All joints and connections of the panel members shall be made by zinc-passivated high-quality Grade 8.8 or superior steel bolts, nuts and washers, secured against loosening. (v) Suitable eyebolts/ lifting clamps shall be provided for the lifting of the panel/shipping section. (vi) A rear door interlock shall be provided i.e rear door can not be opened unless the breaker is in the test position.
Space Heaters:- (i) The panels shall be provided with space heaters to prevent moisture condensation, and maintain cubicle temperature 5°C above the ambient. (ii) The space heaters shall be located at the bottom of the panel and shall be controlled through a double pole MCB and a thermostat with an adjustable setting range of 30 to 70°C. Space heaters shall be supplied from 240V AC auxiliary bus for a space heater. (iii) The work also include the interconnection of existing VCB Panel with complete bus bar connection arrangement and enclousure with above mentioned VCB Panel. The cost of the same shall be deemed to be included in the rates qouted by the contractor (iv) Cost of any other item required to complete the job, is deemed to be included in the rate quoted by the contractor complete all as specified and directed.
M&L cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, complete all as specified and directed.
M&L plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggragate) as in foundation, filling in etc., complete all as specified and directed.
M&L cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in copings, kneelers, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating form work, complete all as specified and directed.
M&L brick work with sub class 'B' bricks, old size, straight or curved on plan exceeding 6 Mtr mean radius, built in cement mortar 1:6, complete all as specified and directed.
M&L 15mm thick rendering in cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surface even and fair without using extra cement, complete all as specified and directed.
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying/ taking out of XLPE cables, foundation of pole, ducts etc. and getting out in any type soil, complete all as specified and directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Removing surplus excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
M&L dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured and paid.
Supplying and laying reinforced precast concrete cable cover, Class HV, Type 1, flat, size 300mmx 180mm x 40mm, as per IS-5820-1970, ISI Marked, complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
BOQ_837699.xls
BOQ • 2.32 MB
PS99T.pdf
Tender Documents • 1.03 MB
Download all tender documents and submit your bid