Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-Finance 65 DEEP NAGAR BIRRING ROAD JALANDHAR CANTT PB | L1 | Accepted-Finance Lowest and reasonable bid | |
| 2 | L2₹46.5 L+₹91,252.90 (2.00%)Rejected-Finance | L2 | Rejected-Finance Other than the lowest bid | |
| 3 | L3₹48.4 L+₹2.9 L (6.29%)Rejected-Finance 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | L3 | Rejected-Finance Other than the lowest bid |
Tender Value
₹49.3 L
EMD Value
₹98,600
Closing Date
9 Nov 2023, 6:00 pmClosed
Garrison Engineer (West)
Kabir Road Jalandhar Cantt
SPECIAL REPAIR TO SUNKEN FLOOR AT COMMON TOILET AT BLDG NO P-164 (NCHQ) AND CERTAIN MINOR WORKS UNDER GE (WEST) JRC
2023_MES_614094_2
GE/JAL(W)-51/2023-24
Open Tender
Civil Works
Item Rate
180 days
Jalandhar Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (West)
₹98,600
Yes
17 Nov 2023
21 Oct 2023
16 Nov 2023
21 Oct 2023
9 Nov 2023
28 Oct 2023
Amount
Demolition of cement concrete above ground level exceeding 15 cm thickness complete all as specified and as directed by the Engineer-in-Charge.
M&L for 10 mm thick rendering in cement mortar 1:3 on fair face finished even and smooth without using water proofing with and including water proofing compound.
M&L for applying two coats of SHALIMAR SUPERCRETE/NITBOND water proofing coating on the entire surface of sunken portion all as specified.
M&L for cement concrete type E-2, 1:5:10 (using 40 mm graded stone aggregate) as in sunken flooring.
M&L for 15mm thick cement screed in cement mortar 1:3 admixed with integral water proofing compound FOSROC's complast X 421 IC @ 130ml per bag of cement incl a bonding coat of FOSROC's Nito bond AR cement slurry/ STP No 1 liquid @ 200ml per bag of complete all as specified. (a) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coatings and achieve a gripping profile that is clean, dry and free from laitance and any other form of surface contamination. The installation instructions in manufacturer's published literature should be strictly complied with, including but not limited to the following :- (b) Chipping out any visible cracks in "V-Groove" pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/ Dr Fixit 302 SBR latex / Perma latex SBR/FOSROC Nitabond SBR latex / Asian Paints latex as required. Final cleaning of surface with power grinder, wire brush, hair brush & vacuum pressure if required. (c) Dampen all surfaces immediately ahead of application of Acrylic modified Cementitious coating of Sika Top Seal - 107 / Brush Bond FOSROC/ Dr Fixit/STP/CICO. (d) Whilst the surface is still damp from saturation (S.S.D), apply one coat of Acrylic modified Cementitious coating of Sika Top Seal - 107/ Brush Bond FOSROC/ Dr Fixit/ STP/CICO of viscosity as per manufacturer's instructions. (e) Apply Glass Fabric Sheet of Sika Fab 1 / FOSROC/ Dr Fixit/ STP whilst the first coat is wet. (f) Once touch dry, apply second coat of Acrylic modified Cementitious coating of Sika Top Seal - 107/Brush Bond FOSROC/ Dr Fixit/ STP/CICO of viscosity as per manufacturer's instructions on the entire area. (g) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direction right angle to the previous coat. (h) The waterproofing coating should be taken to a height minimum 300 mm above the finished floor level on the vertical surface. (j) It is essential to cure Acrylic modified Cementitious coating immediately after application (minimum 6-8 Hrs drying) for a minimum of 3 to 5 days to ensure full cement hydration and to minimize cracking. (k) A protection plaster (12-15mm thick) in CM 1:3 admixed with appropriate Integral water proofing compound has to be applied on the walls. Admixture: Sika Plastocrete Plus / FOSROC / Dr Fixit / STP / CICO confirming to IS 2645. Providing and applying a protection screed of 50mm thick 1:4, cement sand mortar admixed with Sika Plastocrete over the applied water proofing coating on horizontal surfaces. Admixture: Sika Plastocrete Plus / FOSROC / Dr Fixit / STP / CICO confirming to IS 2645. (l) All the corners and joints should be pretreated with an elastic waterproofing sealing tape with a Woven bonding mesh on each surface and an elastic expansions zone in the centre of Make Sika Seal Tape S/FOSROC/Dr Fixit/STP. (m) The membrane has to be protected in accordance with the manufacturer's recommendations until placement of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accordance with manufacturer's recommendations. (n) Waterproofing treatment has to be carried out through applicators authorised by the respective manufacturers and approved by GE.
M&L for 25 mm thick cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) to receive the top layer of tiles complete all as specified.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off premises complete all as specified and as directed by the Engineer-in-Charge.
M&L for non skid ceramic, coloured, joint free, tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match with colour of the tiles over and including screed bed of 15mm thick cement mortar (1:6) complete all as specified and as directed.
M & L for vitrified ceramic tiles matt finished light shade 10 mm thick (Square/rectangular) polished m area of each tiles not exceeding 0.36 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm th screed bed in CM 1:6 complete all as specified and as directed.
S&F glazed ceramic tiles 350mmx250mm/7mm/450x350x7mm thick as ion vertical surfaces viz dados, skirtings etcset and jointed in neat cement slurry and pointed in white cement mixed with pigment to match colour of tiles over and including screed bed 10mm thick cement mortar (1:4) complete all as specified and as directed
Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water built in cement mortar., complete all as specified and as directed by the Engineer-in-Charge
Material and labour for rendering 15 mm thick cement plaster in cement mortar 1:6 on brick work or concrete surfaces finished fair and even without using extra cement complete all as specified and as directed.
M&L for preparing surfaces new plastered surfaces of walls by applying two coats of oil bound distemper over a coat of wall care putty on plastered surface preparatory to distempering complete all as specified.
M&L Plastering 5mm thick in cement mortar (1:3) finished even and smooth without using extra cement as on ceiling complete all as specified
M & L for preparation of new surface of ceiling and applying three coats of white wash complete all as specified and as directed by Engr-in-Charge.
M&L for 15 mm thick cement mortar 1:4 on brick or concrete surface finished even and smooth without using extra cement all as specified. (Working Ht may vary from 10 mtrs to 20 mtrs)
M&L for preparing new plastered or unplastered wall surfaces and applied two coat of Exterior emulsion to Match the colour of the adjoining surface over one priming coat all as specified and directed by Engr-in-charge. (Working Ht may vary from 10 mtrs to 20 mtrs)
M&L for preparing old plastered or unplastered wall surfaces and applied two coat of Exterior emulsion to Match the colour of the adjoining surface over one priming coat all as specified and directed by Engr-in-charge. (Working Ht may vary from 10 mtrs to 20 mtrs)
Taking down Chowkat or frames not exceeding 1.5 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed by EIC.
Taking down Chowkat or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed by EIC.
S&F solid PVC door frame of size 50x47 mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube complete all as specified in Section 8 of SSR Part –II 2010.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing given in Section 8 of SSR Part –II 2020.
S&F 150 mm long aluminium, anodized, barrel tower bolts of extruded section and ISI marked complete all as specified.
S&F aluminum extruded alloy type anodized handles 150 mm long. complete all as specified.
S&F 100 mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised complete all as specified.
S&F pressed steel door frame with two rebates including necessary fixing lugs, hinges, lock stricking plate of size 125 x60mm complete all as specified.
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M&L French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all as specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue with cover plate length 140 mm , anodised, with hard drawn steel spring, fixed in floor all as specified and directed.
S&F in repairs Aluminium die cast Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed.
S&F powder coated aluminium frame for doors,windows, partitions ,ventilators with one or more rebates including joining cleat for fixing etc complete all as specified.
S&F powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S&F sheet glass 4.8 mm thick ordinary quality to be fixed in Al frame work in square exc 0.5 sqm in each pane
Taking up or down 15 mm bore steel tubing and connection including cleaning serviceable steel tubing and fittings for refixing and removing unserviceable from site including cutting chases in wall/floor and making good the surfaces complete all as specified.
Taking up or down 20 mm bore steel tubing and connection including cleaning serviceable steel tubing and fittings for refixing and removing unserviceable from site including cutting chases in wall/floor and making good the surfaces complete all as specified.
S&F 15mm bore galvanized steel water tubing, medium grade with all fittings fixed to wall, ceiling or laid in floors including cutting chases in any surface complete all as specified.
S&F 20mm bore galvanized steel water tubing, medium grade with all fittings fixed to wall, ceiling or laid in floors including cutting chases in any surface complete all as specified.
Dismantling of water tanks (PVC/RCC of any description) exc 250 ltr and n.exc 500ltr capacity and removing from site complete all as specified and as directed
Dismantling of water tanks (PVC/RCC of any description) exc 500 ltr and n.exc 1000 ltr capacity and removing from site complete all as specified and as directed
S&F 500 ltr capacity rotational moulded polythene water storage tank (cylindrical vertical with closed top) ISI marked (Name of firm embossed or engraved on the body of tank) confirming to IS-12701 double layered including dismantling of existing tank hoisted and fixed in position complete all as specified and as directed
S&F 1000 ltr capacity rotational moulded polythene tanks (cylindrical vertical with closed top) ISI marked (Name of firm embossed or engraved on the body of tank) confirming to IS-12701 double layered including dismantling of existing tank hoisted and fixed in position complete all as specified and as directed
S&F 300 ltr capacity rotational moulded polythene water storage tank (cylindrical vertical with closed top) ISI marked (Name of firm embossed or engraved on the body of tank) confirming to IS-12701 double layered including dismantling of existing tank hoisted and fixed in position complete all as specified and as directed
S&F 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minium weight 210 gms ), complete all as specified and directed
S & F in repair 20 mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S & F in repair 15 mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S&F in replacement 15 mm bore chromium plated bib tap fancy type cast copper alloy with crutch or butterfly handle screwed down screwed complete all as specified.
S&F in repair 15 mm bore stop valve (or angle valve) fancy type chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends complete all as specified and directed.
S&F in repair pillar taps, fancy type cast copper alloy with capstan heads chrominm plated fancy type, screwed down high pressure with or without lettered Hot or Cold with long screwed shank and fly nuts, srewed for iron pipe and fixed 15mm bore.
S&F vitreous china wash down water closet pan (pedestal pattern), white, including plastic seat cover closed pattern including bolts, flush pipe of polyethylene of low or high density PVC 32mm dia anti-syphonage pipe and suitable traps etc and connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe etc complete all as specified and as directed.
S & F in repair vitreous China urinals,half stall type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; including , water spreader, flush pipe, waste pipe , grating and Union for discharge pipe including all connected accessories.
S & F in repair vitreous China Sensor urinals (including all accessories,half stall type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; including , water spreader, flush pipe, waste pipe , grating and Union for discharge pipe including all connected accessories.
S&F in repair vitreous china wash hand basin, white, flat back size 550mmx400mm including cast iron or mild steel brackets including cutting for and pinning in brackets complete all as specified and as directed.
S&F in repair 10 litres capacity PVC valve less symphonic action type, flushing cistern, low level, white with inlet, ball valve, PVC flush pipe, float and handle including brackets complete all as specified.
S&F Rimless single piece WC with accessories and cistern fittings size 360x725x735 mm S trap 300 mm (inlcuding UF Soft close seat cover, tornado flushing, hinges all as specified and directed.
S&F angular Stop Cock with wall Flanges all as specified and directed.
S&F bib Cock with wall Flanges all as specified and directed.
S&F Glass shelf of length 600mm, width 100 mm and thickness not less than 5mm including CP railing and Rawl plugs and screws for fixing complete all as specified and directed.
S&F in repair brass chromium plated tolet paper holder complete all as specified and directed.
S&F in repair brass chromium plated Soap Dish Holder complete all as specified and directed.
S&F in repair brass chromium plated towel rail fixed with chromium plated brass screws wooden/plastic gutties complete all as specified and directed.
S&F in replacement PVC connection 15mm dia and 45cm long with two Nos of brass check nuts and washers complete all as specified and directed.
S&F Central Hole Basin Mixer with Regular Spout with Popup Waste System with 450 mm Long Braided Holes all as specified and directed.
S&F brass chromium plated health faucet for pedestal pattern water closet including PVC flexible pipe along with complete necessary fittings complete all as specified and as directed.
S&F in replacement 32mm dia PVC waste pipe for WHB complete all as specified and as directed.
S&F in repair chromium plated grating 125mm dia circular, fixing with cement mortar 1:3 on Nahani or floor trap complete all as specified and directed.
S&F Vitreous china wash hand basin (Oval shape) under counter type bowl type including waste coupling and pipe all as specifed and directed.
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-1 using 20 mm graded aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies , canopies , deck slabs and in shelves and the like complete all as specified and directed.
Mild steel high yield strength TMT bars 10 mm dia and over cut to length bent to shape require including, cranking, hooking ends, bending and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed
Form work to soffits of suspended slabs such as roof slabs, floor slabs, shelves landing and similar work not exceeding 200 mm thick (horzontal or sloping) and to edges of concrete complete all as specified and directed
M&L for 25 mm thick (Lakha Red) granite machine cut as in wash basin counters bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over bedding layer or screed 15 mm thick in cement mortar 1:4 including cutting , grinding, rounding edges, rubbing and polishing complete all as complete all as specified and directed by Engr-in-Charge.
Dismantling of 100/75mm dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required all as specified and as directed by Engr-in-Charge
S&F for 110 mm PVC (SWR) Rain water pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends in any radius complete all as specified and directed.
S&F 110 mm junction single (single tee) equal or unequal complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipe of pressure rating 4 kg/cm2 single socketed in any length with rubber ring joints with adhesive fixed in repair to wall/laid in trenches complete all as specified and directed
S&F 75 mm bore PVC (SWR) bends in any radius complete all as specified and directed
S&F 75 mm dia PVC (SWR) single junction single (single (Tee) equal or unequal dia of pipe complete all as specified and directed.
S&F 75 mm dia PVC (SWR) floor trap with grating including jointing to waste pipe fixed in solvent cment incl taking down damaged floor trap in any position complete all as specified and directed.
Demolition of brick work built in cement mortar incl all quions, arches pillars etc but excluding precast concrete articles all as specified.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan to any radius with old size brick thick walls built in cement mortar 1:6 all as specified.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan to any radius with old size brick thick walls built in cement mortar 1:4 all as specified.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth for sewage line, manhole etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
Description same as per item above, but exceeding 1.5 M and not exceeding 3.0M in depth and getting out in any type of soil complete all as specified and as directed.
M & L PCC 1:3:6 type C-2 using 40 mm stone aggregate as in foundation filling and mass concrete as in man holes septic tank soak well and drain complete all as specified and as directed.
Supplying, laying, jointing and testing 100 mm dia salt glazed stone ware drain pipe grade ‘A’ laid in trenches and jointed in cement mortar 1:1 complete all as specified and as directed.
Supplying, laying, jointing and testing 150 mm dia salt glazed stone ware drain pipe grade ‘A’ laid in trenches and jointed in cement mortar 1:1 complete all as specified and as directed.
M & L 100 mm internal dia of pipe cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate.
M & L 150 mm internal dia of pipe cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate.
M&L precast Cement Concrete 1:2:4 type B1 (using 20mm graded stone agg) as in cover slabs for man holes/Septic tank/Soakage well etc set in cement mortar 1:6 including necessary form work complete all as specified and directed
Surface dressing not exceeding 15cm deep in soft/loose soil. complete all as specified and directed by the Engineer-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for preparation of newly plastered/unplastered surface of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M & L for preparation of new surface of walls and applying three coats of white wash complete all as specified and as directed by Engr-in-Charge.
Mild steel high yield strength TMT bars 6mm to 8mm dia and over cut to length bent to shape require including, cranking, hooking ends, bending and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed
M&L for 40mm thick damp proof course to horizontal or vertical surfaces including applying evenly a coat of hot blown bitumen at the rate of 1.5Kg per sqm and blinding with clean dry sand @ 0.05 cu. m. per sqm and laying a layer of polythene film,50 micron thick,laid on a coat of bitumen primer,@0.30 to 0.50 kg per sq. m. necessary formwork in cement mortar 1:2:4 complete all as specified and directed
Material and labour for cement concrete type D-2, 1:4:8 (40mm graded aggregate) 75mm thick as in sub base of flooring complete all as specified and directed.
Supply and fixing squatting pan WC Orrisa pattern size 580mm x 440mm white with integral foot rest with P or S trap including provn. of lime concrete bedding including breaking up existing damaged WC seat and connecting flush pipe etc and making good to floor complete all as specified and directed.
Material and labour for chequered cement concrete tiles 30 cm x 30 cm x 20 to 25 mm thick set with gray cement and pigments jointed and pointed in neat coloured cement slurry in floors over and incl 15mm thick cement screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for 75mm cement concrete type C-2, 1:3:6 (40mm graded aggregate) all as specified and directed
M&L sand cushioning to under concrete interlocking paver block including watering & consolidation complete all as specified and directed
80mm thick machine pressed precast concrete interlocking paver block and shape and size confirming to IS 15658-2006 of M-40 Grade with grade cement and pigment complete all as specified and directed.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) fitting and fixtures such as switches, socket call bell lamp holder, regulator, sketch fittings etc and, making good disturbed surface of wall, ceiling floor etc complete all as specified and directed.
Taking down old unserviceable sub main wiring of any type and size and making good of disturbed surface of walls/ceilings, complete all as specified and directed.
Taking down main switch/DB complete all as specified and directed.
M & L for concealed point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including PVC conduit ,medium grade with accessories like bends, tees, junction boxes etc fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS type , copper multistranded cable as earth wire including pressed steel sunken boxes for mounting of MODULAR TYPE switch/sockets and regulator and including modular type cover plate white colour all as specified and directed for: (a) One light / fan / call bell point controlled by one, one way switch.
One 3 pin socket out let 5 Amps on same board with other switches.
One 3 pin socket out let 5 Amps on Independent board with other switches.
All as per Ser item No. 117.00 above but with 2.5 sqmm multistranded copper multistranded conductor FRLS cable with 2.5 sqmm earth wire for one 6 pin socket outlet 15 amps on independent board
S & F switch MODULAR 6 Amps, SP, one way, 230 Volts, AC
S & F switch MODULAR 16 Amps, SP, one way, 230 Volts, AC
S & F socket out let multipurpose MODULAR 5 pin 6 Amps, flush type, 230 Volts
S & F socket out let multipurpose MODULAR 5 pin 6/16 Amps, flush type, 230 Volts
M & L ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified.
M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings incl 01x 09 Watt LED bulb complete all as specified and directed.
M & L for sub main wiring with two single core PVC insulated and unsheathed cable 6 sqmm with multi stranded copper conductor , FRLS type cable drawn through and including PVC concealed conduit of not less than 25mm in size complete with all accessories alongwith provn of 6 sqmm PVC insulated and unsheathed ,multi stranded copper conductor , FRLS type cable as earth wire.(Three runs of cable and one run of conduit shall be measured as one length)
Supply, installation & commissioning sheet metal enclosure SPN 8 way double door for mounting DP/SP/TP/MCBs as incoming / outgoing. The DB shall be of IP 43 - IK 09 with metal door complete all as specified and directed at site.
S&F amp rating 240V, 10KA 'C' curve minature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissiong SPN 40 to 63 Amp
S/F MCB SP 6-32 Amps 240 volts
S&F LED tube light fitting 20W (Double side) including LED lamp 20W with 2100 lumen output with internal surge protection device of 4KV with voltage band of 140-280V CRI-6500K (White light) fixtures box type and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.50Sqmm 3 core complete all as specified and directed.
S&F LED tube light fitting 10W slim type with internal surge protection device of 4KV with voltage band of 140-280V CRI-6500K (White light) fixtures box type and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.50Sqmm 3 core complete all as specified and directed.
Supply and Fix recess/ceiling mounting LED light 1x36 Watt cool white ligh of 6500k complete all as specified and directed.
Taking down existing exhaust fan any capacity / type and carry out repair work complete and refixing on the same location all as specified and directed.
BHARAT ENTERPRISES
NATIONAL BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .