Grampanchayat Khandbara Ta. Navapur Dist. Nandur
Grampanchayat Khandbara Ta. Navapur Dist. Nandurar
Installing R.O of 750 LPH Grampanchyat Khandbara Ta. Navapur Dist. Nandurbar
2021_NANDU_674015_1
Tender.work.Khandbara
Open Tender
Consumables
Item Rate
90 days
Grampanchayat Khandbara Ta. Navapur Dist. Nandur
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
15 Apr 2021
7 Apr 2021
14 Apr 2021
7 Apr 2021
13 Apr 2021
7 Apr 2021
90 days
Amount
a)Raw water storage tank type/MOC Control Capacity Make Function – For storage of raw water 2/3 Layered PE tank White/Black color made from virgin material of Food Grate Quality , suitable for the purpose of providing / storage drinking / potable water Provision of Low Level and High Level Switch As given in Annexure-VI Sintex/Any Indian Make with ISI.
b)Inlet Pump Type Number Make Capacity Pressure and power Function – to feed water from storage tank to filter Horizontal , Centrifugal One No Grundfos/Ebra/DP/ITTLowerPump/CRI/Kriloskar As per plant requirement As per plant requirement
c) Micron Cartridge Filter Flow rate MOC NO. of cartridge housing Micron Rating Flow Velocity MOC of cartridge Make Function – fine filtration of water for removal of suspended solids up to 5 micron size prevent chocking/blockage on UF Membrane As per plant requirement FRP/Engineering grade plastic As per plant requirement 5 Micron 2.5 Mtr/Sec PP Osmotic/Ametak-USA/Gopani/Purtex/Hi-tech/Zephyr
d)Ultra Filtratation Membrane Flow rate Membrane Material Normalized Filtration pore size Material of housing Operation Mode Function – to remove Suspended Impurities and enhance the overall recovery of the system / overall life of RO Membranes As per plant requirement PVDF 0.075 micron PVC/ABS Dead- end or cross flow , Interval or continuous air scrubbing. The system shall be fully automatic so as to ensure hourly backwash for about 60 secs. or as per operational requirement of membrane provider / input water quality whichever is earlier Dow / Norrit / Hydranautics / Oltremare / Mann and Hummol / Hi-tek
d)Ultra Filtratation Membrane Flow rate Membrane Material Normalized Filtration pore size Material of housing Operation Mode Make Function – to remove Suspended Impurities and enhance the overall recovery of the system / overall life of RO Membranes As per plant requirement PVDF 0.075 micron PVC/ABS Dead- end or cross flow , Interval or continuous air scrubbing. The system shall be fully automatic so as to ensure hourly backwash for about 60 secs. or as per operational requirement of membrane provider / input water quality whichever is earlier Dow / Norrit / Hydranautics / Oltremare / Mann and Hummol / Hi-tek
e)Anti Scalant Dosing System pump make Quantity Type Capacity Quantity of tan Capacity of tank MOC of tank Make of tank Function – to inhibit scaling of hardness salt and silica on RO Membrane 1 set ASIA LMI/ Injecta / Sonder / Prominent / E-dose / injecta 1 No. Electronic Diaphram type 0-5 LPH 1 No. 100 ltr PE/FRP Indian
f)High Pressure pump Type MOC Quantity Make Capacity Pressure and power Function to develop required pressure for osmosis process on RO membrane Vertical centrifugal Multistage SS316 One No Groundfos/Ebora/TTlowara/CRI/Tonkaflo/Sumo As per plant requirement As per plant requirement
g) Pressure vessel Item MOC Diameter Length MakeFonction to house RO Membrane under pressure RO membrane consisting of membrane housing with RO membrane mounting on skid FRP As per plant requirement As per plant requirement Code line/ Maxima /phoenix/protect/Aqueous
h) Membrane Type Size Average flux MakeOperating temperature Function to remove dissolve salt from water by reverse Osmosis produce permit water less dissolve salt and reject having highly consented salt TFC ,Polyamide As per plant requirement <18 GFD .DOW Filmtec USA/Hydranautics/toary Japan/GE/Hi tech/Oltremare Ambient temperature
i)PH Correction system Pump Make Quantity Type Capacity Quantity Capacity of tank MOC tank Function to enhance PH of RO permeate from 5.5-6 to 7-7.5 as per WHO Guideline 1set ASIA LMI / Sonder/Prominent/E Dose 1 No. Electronic Diaphragm type 0-5 LPH 1 No. 100 ltrs. PE/FRP
j) Ultra Violate system Capacity Make Function - to disinfect water ,will kill bacteria and microorganisms As per plant requirement Alfa/Phillips/ACE Hygiene
k) Cleaning in Place (CIP system ) Quantity of tank Capacity of tank MOC of tank Make of tank Micron Cartridge Filter Flow rate MOC No of cartridge Housing Micron Rating Flow velocity MOC of cartridgeFunction – use for chemical cleaning of RO Membranes over a period of time 1 No. As per plant requirement FRP/MSRL/PE Indian As per plant requirement FRP/Engineering Grade Plastic As per plant requirement 5 micron 2.5 min/sec PP
l) RO Storage tank type MOC Make Control Capacity Function – For storage of product Water from RO plant ( the height of storage tank should be kept in such a way that there is no dead storage ) Tow/ three Layered PE tank white/Black in color made from Virgin material of Food Grade Quality , suitable for the purpose of providing / storage of drinking / potable water. Syntex Any Indian Make with ISI Position of law level and high level switch As given in Annexure-VI
Remote access and Monitoring system Function – based on GSM technology with SMS facility minimum 3 mobile nos. to get real time reporting of plant operations
Pressure Gauges Quantity Location Range Location Quantity Location Range Make Function to measure pressure 4 No Pump outlet ,Filter outlet ,High pressure pump discharge and RO rejected 0-70Kg/cm square Feed pump outlet / filter outlet 2 No. High pressure pump discharge and RO reject 0-20Kg/cm square Forbes Marshal / Waree /Hi-Guru / Ocean/. Beaumer SS MOC
Flow Indicator Quantity Location Type Max operating temp Measuring points Make Function – to measure flow rate at location 3 No. RO Feed , RO Product ,Reject Float type , panel mounted 40 degree centigrade RO Feed , RO Product , Reject Flow Max/Blue and White/FIP/Eureka/GF
High pressure switch and low pressure switch Quantity Location Make Function – for system safety. Stop the system for low suction pressure at high pressure pump and if required high pressure for RO membranes 2 No. Before and after high pressure pump Switzer/Orion/Indfos/Waree/Forbes/Marshall/Denfos
Auto flushing system with solenoid valve Quantity Function – to flush RO system with clean water at the time of stop to enhance life of RO Membranes 1 No.
Electrical control panel with volt Meter, Indicator. ON/OFF Switch Make Location Type Material of panel VoltageFunction – to control and operate system properly Local Skid**Mounted/SS-304 ** MS box pipe frame with primer and 3 coats of epoxy coating Now draw out type As per requirement 415V+/-10% Frequency 50Hz+/-5%,3-phase,4wire system with solidity grounded neutral
Digital Conductivity Meter / TDS Meter Quantity Location Indication Range Max. Temp Make Function – to measure quality power of RO product water 1 No. RO permeate line 4 digit , 1 line LED 0-200 us/cm 40 degree centigrade F Marshal / Hanna/ Olympus / Fivebro / HM
No.3 Disposal of waste water.
No.4 MSEB connection and internal pannel box and electrification
No.5 ATM machine with SMS
No.6 Internal piping of RO and Atm circulating system
No 7 – 2 Tonn Chiller
No.8 Operation and maintenance for period of 5 years
Dharti Constrction
SAI RAJ CONSTRUCTION
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .