Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC AT KARGALI BAZAR BERMO DIST BOKARO JHARKHAND PIN 829104 | BERMO | BOKARO | JHARKHAND | 829104 | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | Rejected-Technical 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | - | Rejected-Technical L1 bidder is techno commercially qualified. | |
| 3 | Rejected-Technical ALU BANKER COLONY PO DHORI BERMO DIST BOKARO JHARKHAND | BERMO | BOKARO | JHARKHAND | 825102 | - | Rejected-Technical Bid not be opened as per NIT terms |
Tender Value
₹15.7 L
EMD Value
₹19,700
Closing Date
2 Sept 2024, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer (EnM)
Office of the General Manager, Dhori Area
Day to day erection and dismantling of 220 V OH line at 06 no. departmental patch for providing lighting power for proper lighting for operation of shovel for a period of 270 days wrt AADOCM, Dhori Area
2024_CCL_315393_3
GM(D)/SO(EnM)/DA/2024-25/27
Open Tender
Electrical and Maintenance Works
Item Wise
270 days
AADOCM, Dhori Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹19,700
23 Sept 2024
19 Aug 2024
3 Sept 2024
20 Aug 2024
2 Sept 2024
20 Aug 2024
20 Aug 2024 - 24 Aug 2024
Amount
Dismantling of pole/street light standard/strut embedded in cement concrete foundation etc. as required.
Dismantling of overhead lines comprising of copper/aluminium overhead conductor, G.I. wire cross arms, insulators etc. as required
Transporting of pole from transport/site to site
Erection of steel pole tubular or rail pole strut concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and re-filling and secured with holding clamps, bolts, nuts, etc. as required.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia x 1.8 metres long stay rod, anchor plate of size 45 cm x 45 cm x 7.5 mm, thimble, stay clamps, turn buckle (20 mm x 60 cm), 7/3.15 mm dia G.I. stay wire and strain wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 diameter and above including binding etc. as required
Supplying and erection of 100 mm x 80 mm pin insulator complete with G.I. spindle and nuts etc. as required 220V grade
Supplying and erection of galvanised ‘D’ iron clamps complete with shackle insulator (100 mm x 110 mm), G.I. bolts, nuts and washers, coach screw etc. as required 220V grade
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long with charcoal/ coke and salt as required. For Transformer
Providing and fixing 25 mm x 5 mm dia G.I. strip on surface or in recess for connections etc. as required.
Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with and finished paint as required.
Supplying of channel iron 75 mm x 40 mm x 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Erection of angle iron/channel iron cross arm on steel tubular etc. as required.
Fitting of light on top of the pole.
Dismantling of light from pole.
G.I. wire 8 SWG
Erection of cradle guard as required
Supplying and drawing following sizes FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/ PVC conduit as required. : 1x1.5 sq.mm (for light connection)
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size is in the existing masonry open duct as required. Upto 35 sq.mm. for lighting tower
Providing and fixing 200 Amp. Fuse disconnector switch unit.
Providing and fixing 100 Amp. Fuse disconnector switch unit.
Dismantling of 50/100 KVA transformer with all connection (HT/LT)
Installation of 50/100 KVA transformer with all connection (HT/LT) and testing
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanized iron/steel works. Two coats
Painting with aluminium paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Total impact of GST for the purpose of CTC
M/S UPENDRA ELECTRICAL
M/S KUMAR ENTERPRISES
techsummary_326853.pdf
PDF • 0.18 MB
finsummary_326853.pdf
PDF • 0.18 MB
WO27c.pdf
PDF • 1.44 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .