Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹8.7 L+₹25,949 (3.09%)Rejected-Finance | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | L3₹8.9 L+₹50,379 (5.99%)Rejected-Finance | L3 | Rejected-Finance Quoted other than lowest rate | |
| 4 | L4₹9.2 L+₹76,279 (9.08%)Rejected-Finance | L4 | Rejected-Finance Quoted other than lowest rate | |
| 5 | L5₹10.3 L+₹1.9 L (22.9%)Rejected-Finance BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | L5 | Rejected-Finance Quoted other than lowest rate |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Jul 2022, 6:00 pmClosed
SH ASHOK KUMAR, EE, IDSE
GE NORTH BATHINDA BATHINDA MIL STN
REPAIR /REPLACEMENT AND IMPROVEMENT OF INTERNAL POINT WIRING, SUB MAIN WIRING, DBs FITTING AND FIXTURES IN SHIVAJI AND PEERU SINGH ENCLAVE UNDER GE NORTH BATHINDA AT BATHINDA MIL STN
2022_MES_532300_1
8937/NIT-35/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
GE NORTH BATHINDA
Class E category b (i)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹40,000
Yes
16 Aug 2022
20 Jun 2022
29 Jul 2022
20 Jun 2022
27 Jul 2022
4 Jul 2022
21 Jun 2022 - 27 Jun 2022
Amount
SCHEDULE 'A' E/M Works
Taking down carefully unserviceable copper/aluminium point wiring from existing conduit pipe (light, fan, socket or power point but not removed conduit pipes) complete including removal of unserviceable fitting such as switches,sockets, ceiling rose, light fittings etc. and removing the retrieved materials from site including making good the distrubed surfaces of wall, floors, ceiling etc. to match with the adjoining work complete all as specified and directed by Engineer-in-charge.
Material and labour for point wiring with multi stranded copper conductor FRLSH cable, 1100 Volts grade PVC insulated and unsheathed of size 1.5 sqmm single core in existing PVC concealed conduit and including new MS sunken box and 3mm thick bakelite laminated sheet top cover for one fan/exhaust fan /light controlled by one switch including provision of 1.5 sqmm PVC insulated unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth and connecting to earth dolly, complete all as specified and directed.complete all as specified and directed by Engineer-in-charge. Make of cable :- Havellls/Dcab/RR KABEL
All as per item No 2 here in before but for socket outlet 5 pin 5/6 Amp on same board, complete all as specified and directed by Engineer-in-charge.
All as per item No 2 here in before but for socket outlet 5 pin 5/6 Amp on independent board but not below the switch board, complete all as specified and directed by Engineer-in-charge.
All As per item No 2 in before but for one light point controlled by Two Two way switch, complete all as specified and directed by Engineer-in-charge.
All As per item No 2 in before but for bell/buzzer point, complete all as specified and directed by Engineer-in-charge.
All as per item No 2 here in before but for socket outlet 6 pin, 15/16 Amp multi purpose, 2 in 1 on independent board with 2.5 Sqmm cable & including 2.5 sqmm single core multi stranded FRLSH copper earth wire to common earth, complete all as specified and directed by Engineer-in-charge.
Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power point) complete including existing conduit pipes and removal of unserviceable fitting such as switches, sockets, ceiling rose, light fittings etc. and removing the retrieved materials from site including making good the distrubed surfaces of wall, floors, ceiling etc. to match with the adjoining work, complete all as specified and directed by Engineer-in-charge.
Material and labour for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in and including PVC concealed conduit not less than 20mm dia ( medium duty ISI marked) and conduit fittings with and including 3 mm thick bakelite laminated sheet top cover for one fan / light controlled by one switch including provision of 1.5 Sqmm PVC insulated & unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly, complete all as specified and directed by Engineer-in-charge. Make of cable :- Havellls/Dcab/RR KABEL
All as per item No 9 here in before but for socket outlet 5 pin 5/6 Amp on same board, complete all as specified and directed by Engineer-in-charge.
All as per item No 9 here in before but for socket outlet 5 pin 5/6 Amp on independent board but not below the switch board, complete all as specified and directed by Engineer-in-charge.
All As per item No 9 in before but for one light point controlled by Two Two way switch, complete all as specified and directed by Engineer-in-charge.
All As per item No 9 in before but for bell/buzzer point, complete all as specified and directed by Engineer-in-charge.
All as per item No 9 here in before but for one socket outlet 6 pin, 6/16 Amp multipurpose 2 in 1 on independent board with cable of 2.5 Sqmm, multi stranded copper conductor FRLSH cable including provision of 2.5 Sq mm PVC insulated stranded copper conductor FRLSH cable continuos as earth wire connected to earth dolly, conductor etc., complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch piano flush type, single pole, one way, 5/6 Amps ISI mark, complete all as specified and directed by Engineer-in-charge.
Supply and fixing Socket outlet multipurpose, 2 in 1, 5 pin, 5/6 Amps, flush type complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch piano flush type, single pole, one way, 15/16 Amps ISI mark complete all as specified and directed by Engineer-in-charge.
Supply and fixing Socket outlet multipurpose, 2 in 1, 5 pin, 15/16 Amps, flush type complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch piano flush type, single pole, two way, 5/6 Amps ISI mark, complete all as specified and directed by Engineer-in-charge.
Supply and fixing Bell push, flush type, 5 amp complete all as specified and directed by Engineer-in-charge.
Supply and fixing stepped type electronic fan regulator flush type on the existing bakelite laminated sheet etc. as reqd, complete all as specified and directed by Engineer-in-charge.
Supply and fixing Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body, complete all as specified and directed by Engineer-in-charge.
Supply and fixing Buzzer, Ding Dong AC. 230 volts,single pole, complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement Lamp holder of PVC/Polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb, complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement 18/20 watt Retro LED tube light fitting, wall/surface mounted, IP 20 protection, conforming to IS 16106/IS 16107, minimum 6000K batten decorative type 4 feet long polycarbonate body, white, in built LED driver, power factor>0.95 , Make – all as per Crompton Cat Part No. DMLN1LT8-16 (for batten) and Cat part No. LT8-20-865-2 (for tube light) including 18/20 watt tube rod or equivalent model of any make given in Appx 'B' connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement mirror light fitting of 07 watt, 6000K, linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete including 07 watt tube rod all as Model No LCL- 07- CDL of Crompton with 07 watt rod or equivalent model of approved make from list of make attached in tender documents including connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement Wall Mount Light fixture in cylindrical/doom profile made up of polycarbonate suitable for LED Lamp and including LED 7/9 Watt lamp (100 lumens per watt), complete fitting with lamp and all other fixing accessories including electric connection, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement energy efficient LED street light fitting of 25 Watt with PDC aluminium body and clear glass with lens for wide beam distribution, top maintainable type with IP 66 degree of protection, PF>0.95 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 5 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including 25 watt LED lamp with GI brackrt-01 No, MS clamp-02 Nos suitable for walls/ columns and making electrical connection with providing of 1.50 metre long twin core round copper conductor cable of suitable size and testing complete all as per SYSKA cat part No. SSK-SLF-CF-25W-WL or equivalent model of any make given in Appx 'B', Cat Part No. as approved by GE complete all as specified, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and as directed by Engineer-in-charge.
Material and labour for Sub main wiring complete with two single core 4 sqmm,1100 volts grade, PVC insulated, multi stranded copper conductor cable FRLSH with continuous copper earth conductor of 4 sqmm in existing PVC concealed conduit including taking down old unserviceable submain wiring, complete all as specified and directed by Engineer-in-charge. Make : Anchor/Havells/Dcab
Material and labour for Sub main wiring complete with two single core 6 sqmm,1100 volts grade, PVC insulated, multi -stranded copper conductor cable FRLSH with continuous copper earth conductor of 6 sqmm in existing PVC concealed conduit including taking down old unserviceable submain wiring, complete all as specified and directed by Engineer-in-charge. Make : Anchor/havells/Dcab.
Material and labour for Sub main wiring complete with two single core 4 sqmm,1100 volts grade, PVC insulated, multi stranded copper conductor cable FRLSH with continuous copper earth conductor of 4 sqmm in & including PVC conduit size 20mm including taking down old unserviceable submain wiring, complete all as specified and directed by Engineer-in-charge. Make : Anchor/havells/Dcab.
Material and labour for submain wiring complete with two single core 6 sqmm 1100 volts grade, PVC insulated multi stranded copper conductor cable FRLSH with continuous copper earth conductor of 6 Sqmm in & including PVC conduit size 20 mm including taking down old unserviceable submain wiring, complete all as specified and directed by Engineer-in-charge. Make : Anchor/havells/Dcab.
Supply and fixed sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB SPN 12 way 230 V AC with 200 Amp rated bus bar, Double Door,12 modules, dust and vermin proof suitable for incorporation of MCB's and isolators etc including taking down old unserviceable MCB DB's, complete all as specified and directed by Engineer-in-charge.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 8 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc. and including making good disturbed surfaces of walls as necessaty, complete all as specified and directed by Engineer-in-charge.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) TPN, 4 Way 433 V (8+12 modules), double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc. and including making good disturbed surfaces of walls as necessaty, complete all as specified and directed by Engineer-in-charge.
Supply and fixing (Concealed with wall) single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC/Gyeser supply including taking down old unserviceable enclosure, complete all as specified and directed by Engineer-in-charge.
Supply and fixed MCB SP suitable for 230 volts AC supply 6 to 40 Amps, SP rupturing capacity not less than 10KA, C Curve ISI Marked, 1 Module including taking down old unserviceable MCB SP, complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB SPN 40 Amps, 10 KA 'C' curve 230 V AC, 50 Hz including necessary attachment including taking down old unserviceable MCB SPN, complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB TPN 63 Amps 415 Volt AC, C curve, 4 module capacity not less than 10 KA including taking down old unserviceable MCB TPN, complete all as specified and directed by Engineer-in-charge.
Dismentling & Taking down carefully existing panel/meter board and electric/electronic meters, deposite the same meters safely to E/M store yard for refixing complete all as specified and as directed.
Repair /maint of u/s switch board /distribution board unscrewing from its existing position & checking all connection of board and taking down all unserviceable items of board like switch, socket, fan regulator and petty repairs (if required) and making serviceable the switch point complete all as specified and as directed by Engineer in charge. Note:- Hylum sheets, Switches, sockets and fan regulator shall be measured and paid seprately under appropriate item Sl No 43 to 53
Supply and fixing in replacement of 3mm thick bakelite sheet 4 inch x 4 inch including suitable machine screws including taking down old unserviceable sheet complete all as specified and as directed by Engineer-in-Charge. Make - Anchor/Hylem
Supply and fixing in replacement of 3mm thick bakelite sheet 7 inch x 4 inch including suitable machine screws including taking down old unserviceable sheet complete all as specified and as directed by Engineer-in-Charge. Make - Anchor/Hylem
Supply and fixing in replacement of 3mm thick bakelite sheet 8 inch x 10 inch including suitable machine screws including taking down old unserviceable sheet complete all as specified and as directed by Engineer-in-Charge. Make - Anchor/Hylem
Supply and fixing in replacement of 3mm thick bakelite sheet 10 inch x 12 inch including suitable machine screws including taking down old unserviceable sheet complete all as specified and as directed by Engineer-in-Charge. Make - Anchor/Hylem
Supply only switch piano flush type, 5/6Amps, 250 volts, single pole, one way fixed on existing sheet complete all as specified and as directed by Engineer-in-charge.
Supply only switch piano flush type, 15/16Amps, 250 volts, single pole, one way fixed on existing sheet complete all as specified and as directed by Engineer-in-charge.
Supply only two way switch piano flush type, 5/6Amps, 250 volts, single pole, one way fixed on existing sheet complete all as specified and as directed by Engineer-in-charge.
Supply only Socket outlet multipurpose. 2 in 1, 5 pin 5/6 Amp, 250 volts flush type fixed on existing sheet complete all as specified and as directed by Engineer-in-charge.
Supply only Socket outlet multipurpose. 2 in 1, 5 pin 15/16 Amp, 250 volts flush type fixed on existing sheet complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Bell push, flush type, 5 amp flush type fixed on existing sheet complete all as specified and as directed by Engineer-in-charge.
Supply and fixing stepped type electronic fan regulator flush type fixed on existing bakelite sheet, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Retro LED 20 watt tube only appx 4 ' long 6000k min 100 lumens per watt with inbuilt driver to be fixed in to existing batten in replacement of tube 34/40 watt including taking down of existing tube rod, complete all as specified and directed by Engineer-in-charge. Make : Crompton/Bajaj/Philips/Syska/ Havells.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in earthing pit including necessary form work, excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR (Part – I) including taking out/dismantling old unserviceable earthing system, complete all as specified and directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
Aman Enterprises
NASIB ENGINEERS AND CONSTRUCTION
SATTYAM BUILDERS
RS ENTERPRISES
M/s VISHAL ELECTRIC STORE
M/s Kataria Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .