| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-Finance N A | NA | NA | 121004 | ₹3.3 L | L1 | Accepted-Finance ok |
| 2 | L2₹3.3 LAccepted-Finance HOUSE NO Z 1 85 WELCOME SEELAMPUR NORTH EAST DELHI 110053 | NORTH EAST | DELHI | 110053 | ₹3.3 L | L2 | Accepted-Finance ok |
| 3 | L3₹3.6 LAccepted-Finance 11 C GROUND FLOOR DYADER ENCLAVE VIKAS NAGAR ITTAM NAGAR WEST DELHI 110059 | WEST | DELHI | 110059 | ₹3.6 L | L3 | Accepted-Finance ok |
Tender Value
₹6.0 L
EMD Value
₹11,987
Closing Date
16 Feb 2026, 3:00 pmClosed
Assistant Engineer ( E )
Assistant Engineer ( E ) NWESD-II, PWD, Pitampura Police Lines, Delhi
Miscellaneous electrical works i.e.SITC of Domestic Pumps fans fittings security lights DBs and Associated Accessories,AMC of Audio system of Lalit kala,open kala manch etc.at Lakshmi Bai College,Ashok Vihar Delhi. (SH Servicing of Ceiling Fans)
2026_PWD_286589_1
174/EE(E)/AE(E)-II/NWED/PWD/ 2025-26
Open Tender
Electrical Works
30 days
Laxmi bai college, Ashok vihar
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹11,987
Yes
18 Feb 2026
10 Feb 2026
16 Feb 2026
10 Feb 2026
16 Feb 2026
10 Feb 2026
Servicing, oiling, greasing and checking the nut & bolt, cotter pin, insulator, screw wiring, connection etc of installed ceiling fans/ Wall Fan/ Exhaust fan and replace the faulty items if required as mentioned above tightening the blades including cleaning complete etc. as required.
Replacement of following parts of 1200/1400 MM ceiling fan i/c rebate of old parts i/c testing as required: a) Ball Bearing 6201
b) Ball bearing 6202
Supplying and fixing of 2.5 MFD Capacitor on existing fan including connections etc. required.
Dismantling, rewinding & reinstallation of 1200/ 1400 mm ceiling fan with suitable size copper wire including varnishing, baking, nomex paper/ gasket set, lubricant oil, greasing, wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. along with cartage from site to workshop & back incl. credit of old burnt out dismantled copper wire etc. as required at site.
Dismantling, rewinding & reinstallation of 300 mm exhaust fan with suitable size copper wire including varnishing, baking, nomex paper/ gasket set, lubricant oil, greasing, wiring from point to fan (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. along with cartage from site to workshop & back incl. credit of old burnt out dismantled copper wire etc. as required at site.
S/I/T/C of 1200 mm sweep BEE star rating energy efficient ISI marked ceiling fan capacitor type with double ball bearing suitable for operation of single phase AC supply with power Consumption of Max. 50W capable to deliver 220 CFM (min.), speed of 350 rpm (min.) i/c wiring the down rod of standard length (upto 30 cm) with 1.5 Sqmm FR PVC insulated copper conductor single core cable etc as reqd
SITC of wall fan 400 mm sweep oscillating type having plastic blade complete with all accessories such as front jaali i/c connection etc. as reqd. (including dismantling the old fitting if any)
Supplying & fixing of 300 mm sweep 1400 RPM 230 Volt 1-ph 50 Hz AC heavy duty Exhaust fan in the existing opening including making good the damage, connection, testing and commissioning etc. as reqd.
Supplying and fixing double sided LED Light Signage on Ceiling/wall mounted (with alphabets, arrow sign & logo of Exit/FireHydrant) etching on min. 6mm + 6mm transparent acrylic sheet of 350 mm x 170 mm (normal size) with extra super bright LED's in glass epoxy PCB strip concealed in top mounted suitable size 20 SWG M.S. Box duly powder coated & equiped with necessary circuit to step down from 230 V AC to 6V/12V DC with batteries for alteast 10 hrs. back-up & built in battery charger including testing &commissioning etc. as reqd. at site.
Supplying & Fixing of Fire retardant / Extinguishing Elect. insulated met flooring sheet of 2.0 mm thick + 10% according to IS: 15652, 2006 meeting requirements of IS: 3043, IS: 5216 (Part 1, 2& 3), IS: 8437 and IEC 479 Pub-1, Tested for breakdown strength, tensile/ elongation, ageing, properties, Insulations resistance, effects of acid, alkaline, diesel & transformer oil, leakage current test, having min. width of 1000 mm + 20 mm. All allied material such as pu-resin, chemi bound (Hardener), spl. PVC adhesive, liquid primer Annexure "A" Clause C of IS: 15652 and suitable for Class-A upto 3.3 KV without HT Movement
Refilling of ABC type fire extinguishers following capcity carrying to workshop and after refilling reinstallation at same site as per site required. a) 50 Kg
Supplying & fixing of Co2 type fire extinguishers capacity 4.5 Kg wall mounting bracket handle horn pipe complete as per IS 2878 etc. as per site reqd.
Supplying & fixing of ABC type fire extinguishers capacity 6 Kg completed with first filling as per IS 15683 Storage Pressure horn pipe discharge Tube etc. reqd. at sitesize nut bolts or rivets after dismantling of existing rusted/ worn out sheet etc. complete as required.
Less credit for following dismantle materials received from the work: a) Assorted Ceiling Fan/ Wall Fan/ Exhaust Fan
b) Dismantled Ball bearing/Capicitor
c)Assorted Fire Extinguher Of ABC/Co2 Type
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.29 MB
BOQ_379415.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid