| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹92.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹1.2 Cr+₹27.6 L (29.9%)Rejected-Finance 368 MAHESHPUR OPPOSITE GOVT PRIMARY SCHOOL SECTOR 21 PANCHKULA 134112 HR | PANCHKULA | PANCHKULA | HARYANA | 134112 | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
27 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE 138 WE
HQ 138 WE C/O 56 APO
PROVISION OF CENTRAL MEDICAL GAS SUP THROUGH MANIFOLD ROOM OF VARIOUS WARDS/ DEPARTMENTS OF GH UNDER GE 865 EWS AT LEH
2021_MES_445265_2
138WE/L-26/2021-22
Open Tender
Civil Works - Others
Item Rate
180 days
GE 865 EWS
AS PER TENDER DOUCEMENT
8 documents required · 8 mandatory
₹1,000
Yes
GE 865 EWS
₹1.8 L
Yes
16 Aug 2021
6 Jul 2021
29 Jul 2021
6 Jul 2021
27 Jul 2021
13 Jul 2021
60 days
Amount
Excavation over areas, not exceeding 1.5mtrs deep and getting out in hard/dense soil complete all as specified and as directed.
Removing excavated material (Soil) exc 50mtrs but not exc 100m and depositing where directed at a level not exc 1.5 mtrs above the starting point complete all as specified and as directed.
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out disintegrated rock complete all as specified and as directed.
Excavation in trenches for foundation etc not exc 1.5m wide and not exc 1.5m in depth in any type of soil complete all as specified and as directed.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Returning filling in including spreading leveling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed.
Material and Labour for PCC (1:4:8), type D-2 using 40mm graded crushed aggregate as mass concrete and filling of foundation complete all as specified and as directed.
Material and Labour for pre-cast cement concrete 1:3:6 (using 20mm graded crushed stone aggregate), type C-1 as in block masonry with solid blocks, exc. 10cm in width and setting in cement mortar 1:6 complete all as specified and as directed.
Material and Labour for mild steel TMT bars 10mm dia and over cut to length bent to shape as required, including crancking bending, spirally for hooping columns hooking ends and binding with and including mild steel wire not less than 0.9mm dia complete all as specified and as directed.
Material and Labour for mild steel TMT bars 6mm dia to 8mm dia cut to length bent to shape as required as in stirrups and spacers complete all as specified and as directed.
Material and Labour for form work to fair finished concrete surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar works, vertical or to batter complete all as specified and as directed.
Material and Labour for form work to rough finished concrete surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar works vertical or to batter complete all as specified and as directed.
Material and Labour for form work to rough finished concrete surfaces to sides and soffits of floor or roof beam, beam hunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhanging, etc, also splays between floors and beams, etc.complete all as specified and as directed.
Material and Labour form work for rough finished concrete surfaces to sides of square, rectangular or polygonal pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
Material and Labour for Form work to soffits of suspended slabs such as roof, floor slabs, landings etc n.exc 200mm thick (horizontal or sloping) complete all as specified and as directed.
Material and Labour for Form work to edges of concrete flats nexc 20 cm wide complete all as specified and as directed.
Material and Labour Cement concrete M-30 (using 20 mm graded crushed stone aggregates) as in foundations, including rafts, footings, foundations beams, plinth beams, bases for column etc, basement slabs, under reamed piles ad mass concrete complete all as specified and as directed.
Material and Labour Cement concrete M-30 (using 20 mm graded crushed stone aggregates) as in Beams, Cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
Material and Labour Cement concrete M-30 (using 20 mm graded crushed stone aggregates) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
Material and Labour for reinforced cement concrete M-30 (using 20 mm graded crushed stone aggregates) as in slab supported on walls beam, and columns in floors, roofs landings, balconies etc complete all as specified and as directed.
Material and Labour for Rendering 10 mm thick in cement mortar (1:6) on other than fair faces of brick/concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed.
Material and Labour for Rendering on external surfaces of brick / concrete surface 10mm thick in CM 1:6 (First Layer) and 5 mm thick in CM 1:4 (Final Layer) with approved WPC and finished the surface even and fair without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid separately.
Supply only WPC all as specified and directed.
Material and Labour for Rendering 5mm thick in cement mortar (1:4) on fair faces of brick/concrete surfaces of walls, finished even & fair without using extra cement complete all as specified and as directed.
Material and Labour for 100mm thick cement concrete 1:3:6 type C-2 as in floor, finished even and fair complete all as specified and as directed.
Material and Labour for 40mm thick cement concrete 1:2:4 type B-1 as in floor finished even and fair complete all as specified and as directed.
Material and Labour for screed bed or bedding layer of mortar 15 mm thick for laying floor tiles in CM 1:4 complete all as specified and as directed.
Material and Labour for 7mm thick non skid coloured ceramic tiles (area of each tile exc 0.11Sqm and n.exc 0.18 Sqm) etc set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments complete all as specified and as directed.
Material and Labour for hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to true surface complete all as specified and as directed.
Material and Labour for 75mm thick PCC, 1:3:6 type C-2 using 20mm graded crushed stone aggregates as in plinth protection finished even and smooth with out using extra cement complete all as specified and as directed.
Material and Labour for two coats cement base paint on newly plastered surfaces including preparation of surfaces complete all as specified and as directed.
Material and Labour for two coats of distemper oil emulsion on newly plastered surfaces of wall including preparation and chalk whiting on plaster surfaces complete all as specified and as directed.
Material and Labour for three coats of white wash on newly plastered surfaces of ceiling including preparation complete all as specified and as directed.
Supply and Fixing powder coated (min thickness of powder coating 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
Supply and Fixing power coated Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
Supply and Fixing power coated anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
Material and Labour for prelaminated particle board 18/19 mm thick, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to aluminium frame work complete all as specified and as directed.
Supply and Fixing 4 levers mild steel Mortice lock, vertical type, size 100mm complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of 6+6 Oxygen manifold with tail pipe and NRV complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of 2+2 Oxygen manifold with esab regulator emergency complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of semi automatic control panel for Oxygen complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of vacuum compressor system 02 Nos 5 HP IA with silencer, filter & motor electrical etc complete all as specified and as directed.
Supply, Installation, Testing and commissioning of auto cut switch for vacuum pump complete all as specified and as directed.
Material and Labour for 1000 ltrs M S tank for vacuum complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of 2 Nos Air Compressor- belt driven, oil free, tank mounted, single stage, capacity –5 HP, complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of drier 15 CFM, complete all as specified and as directed.
Material and Labour for fixing of 3 stage breathing Air filter for 45 to 60 CFM as per ISO 8573-1, complete all as specified and as directed.
Material and Labour for fixing fittings for Air compressor complete all as specified and as directed.
Material and Labour for fixing of copper tubing of size 15 mm OD, 0.9mm wall thickness including proper saddling, clamping and insertion of branches connections including all fittings for medical use, complete all as specified and as directed.
Material and Labour for fixing of copper tubing of size 22mm OD, 0.9mm wall thickness including proper saddling, clamping and insertion of branches connections including all fittings for medical use, complete all as specified and as directed.
Material and Labour for fixing of copper tubing of size 28mm OD, 0.9mm wall thickness including proper saddling, clamping and insertion of branches connections including all fittings for medical use, complete all as specified and as directed.
Material and Labour for fixing of copper tubing of size 12mm OD, 0.9mm wall thickness including proper saddling, clamping and insertion of branches connections including all fittings for medical use, complete all as specified and as directed.
Supply and fixing sigma type gas outlet for oxygen for medical, complete all as specified and as directed. Make : As approved by GE.
Supply and fixing sigma type gas outlet for vacuum for medical, complete all as specified and as directed. Make : As approved by GE.
Supply and fixing sigma type gas outlet for Nitrious for medical, complete all as specified and as directed. Make : As approved by GE.
Supply and fixing sigma type gas outlet Air for medical air, complete all as specified and as directed. Make : As approved by GE.
Material and Labour for fixing ¾’ Brass Ball valve with end fittings including all fittings for medical use, complete all as specified and as directed. Make : As approved by GE.
Material and Labour for fixing ½’ Brass Ball valve with end fittings including all fittings for medical use, complete all as specified and as directed.
Material and Labour for fixing 1” Brass Ball valve with end fittings including all fittings for medical use, complete all as specified and as directed.
Supply and fixing probe for Oxygen outlet, complete all as specified and as directed.
Supply and fixing probe for Vacuum outlet, complete all as specified and as directed.
Supply and fixing probe for Air outlet, complete all as specified and as directed.
Supply and fixing BPC flow meter (0-15 LPM) including humidifier bottle, complete all as specified and as directed. Make : As approved by GE.
Supply and fixing ward vacuum unit including regulator, gauge and 600ml polycarbonate jar for showing negative pressure complete all as specified and as directed. Make : As approved by GE.
Supply, Installation, Testing and Commissioning of high pressure tube for vacuum complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of vacuum trolley as approved by GE complete all as specified and as directed.
Material and Labour for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6.30mm thick buried directly in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connected to and including GI strip of size 32x6mm by means of steel bolts, nuts, check nuts and washers test points made of GI strip 40x8mm, 10 cm long, PCC 1:2:4 type B-1 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mess and light grade GI protection pipe 40mm bore upto 5m length for drawing in earth lead, salt, charcoal etc. including excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50m complete all as shown in electrical plate No 5 of MES schedule 2009 part-I and connected complete including testing on completion complete all as specified and as directed. (For pole earthing)
Material and Labour for earth continuity conductor for main earthing lead fixed to wall on batten or recess or chases or buried on ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc, as required of size 32x6 mm GI strip complete all as specified and as directed.
Material and Labour for Air Termination, single pointed copper rod 12 mm dia and 300 mm long complete all as specified and as directed.
Material and Labour for copper strip 20 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductor above ground complete all as specified and as directed.
Material and Labour for earthing with copper plate 60cmx60cmx3.15 mm thick electrode and 20mmx3mm copper strip as earthing lead thick buried directly in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to and including copper strip of size 25x4 mm by means of bolts, nuts, check nuts and washers, PCC 1:2:4 type B-1 in pit, medium grade GI watering pipe 20mm bore with funnel wire mess and light grade GI protection pipe 40mm bore for earth lead, salt, charcoal etc including excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50 mtr complete all as shown in electrical plate No 5 of MES schedule 2009 part-I and connected complete including testing on completion, complete all as specified and as directed.
Material and Labour for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hex, head screw complete all as specified and as directed.
Surface excavation n. exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and as directed.
Material and Labour 150mm thick (spread thickness) soling (or sub base) with broken boulders or quarried stone interstices filled surface formed and consolidated to required gradient and camber complete all as specified and as directed.
Material and Labour for cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) as in sub base of path, 75 mm thick complete all as specified and as directed.
Material and Labour for cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in coping including necessary form work weathering slightly rounded or chamfered angles complete all as specified and as directed.
Material and Labour for 80mm thick M-40 grade Machine pressed concrete interlocking paver block any shape and size conforming to IS-15658-2006 with gray cement and pigment complete all as specified and as directed.
Material and Labour for 40mm thick sand cushioning under paving block including watering and consolidation for interlocking tiles complete all as specified and as directed.
Supply, laying & Testing cable XLPE insulated, screened PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 95 sq mm 3.5 core complete all as specified and as directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation or for laying cables etc n.exc 10 sqm on plan and n.exc 1.5 mtr in depth and getting out in hard/dense soil complete all as specified and as directed.
Supply, spreading & gently punning fine dry clean river sand for cable cushioning complete all as specified and as directed.
Supply and laying Un-reinforced precast cover LV type 1 Flat size 250x150x40mm complete all as specified and as directed.
Material and Labour for concealed point wiring with copper conductor cable multistrand, single core 1.5 Sqmm size for one light point or bell point/ Exhaust fan point controlled by one switch including one run of 1.5 Sqmm multistrand PVC copper conductor cable for earth continuity in and including PVC conduit pipe of approved size and quality fixed on walls/ceiling including MS Sunken box of suitable size heavy duty type for mounting switches / sockets etc complete all as specified and as directed.
All as per item No 86 but for 5 Amps Switch Socket Combination in same Board with 1.5 Sqmm cable complete all as specified and as directed.
All as per item No 86 but for 5 Amps Switch Socket Combination in independent board with 1.5 Sqmm cable complete all as specified and as directed.
All as per item No 86 above but for concealed power point 3 pin switch socket 15 AMP with PVC copper conductor cable multistrand unsheathed 2.5Sqmm on independent board incl one run 1.5 Sqmm multistrand PVC copper conductor cable for earth continuity in and including PVC conduit pipe of suitable size fixed on wall incl MS sunken box of suitable size heavy duty type complete all as specified and as directed.
Supply and Fixing switch Modular type one way 6/10 AMP complete all as specified and as directed.
Supply and Fixing switch Modular type one way 16 AMP complete all as specified and as directed.
Supply and Fixing switch Modular socket 6/10 A-2/3 pin combined 2 Module complete all as specified and as directed.
Supply and Fixing switch Modular socket 6A/16 A-2/3 pin combined 2 Module complete all as specified and as directed.
Supply and Fixing white cover plate with frame (inner plate) 3 module complete all as specified and as directed.
Supply and Fixing white cover plate with frame (inner plate) 8 module complete all as specified and as directed.
Supply and Fixing white cover plate with frame (inner plate) 6 module complete all as specified and as directed.
Supply and Fixing white cover plate with frame (inner plate) 4 module complete all as specified and as directed.
Supply and Fixing Bulkhead designed Ellipse Neo Oval type available with premium quality diffuser for glarefree light and easy to install snapfit installer of capacity 6.5 W LED 6000K with complete connection complete all as specified and as directed. Make : Cat Part No of Bajaj LHEXCGP7PN5W006 or eqvt to Crompton/Havells/Phillips/Wipro
Supply and Fixing lamp holder insulated body with back plate suitable for batten fittings complete all as specified and as directed.
Supply and Fixing LED lamp 10 watt complete all as specified and as directed.
Supply and Fixing decorative durable LED batten fitting 20 Watt 6000K (E-lite LED pride Plus) 4 feet long with decorative and caps, powder coated CRCA decorative having driver connector block etc complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core all as required at site or as directed. Make : Cat Part No of Havells LHEXBLP7PN1W020 or eqvt of Bajaj/Crompton/Phillips/Wipro
Material and Labour for ceiling rose surface bakelite 65x50 mm two to three terminals complete all as specified and as directed.
Supply and Fixing sheet metal enclosure TPN for DBs 6 way 415 volts with blank plate Double Door complete all as specified and as directed.
Supply and Fixing sheet metal enclosure SPN for DBs with 200 AMPs bus bar of 08 way 240 volts with blank plate Double Door complete all as specified and as directed.
Supply and Fixing 3 phase plug and socket 4 pole (industrial type) of capacity 32A including MCB TPN 32 AMP and plug complete all as specified and as directed.
Supply and Fixing in MCB TPN 100 AMP 415 Volts complete all as specified and as directed.
Supply and Fixing in MCB TPN 32 AMP 415 Volts complete all as specified and as directed.
Supply and Fixing MCB Double Pole (DP) 63 AMP 240 Volts complete all as specified and as directed.
Supply and Fixing MCB single phase (SP) 6 to 32 AMPs 240 Volts C Curve complete all as specified and as directed.
Material and Labour for eathing complete with galvanized steel earth plate electrode of size 60cm x 60cmx 6.30mm buried directly in the ground to a depth not less than 2.25 mtr with top edge not less than 1.5 mtr below GL connected to and including GI earth wire 4mm dia and GI pipe 15mm dia light grade pipe for earthing protection to the extend of max 7.5 mtr connected to the plate by mean of GI nut, bolts, washers and further to test point by provn of Charcoal salt etc complete with all as per SSR Part-I electrical plate No - 05 PCC Chamber in PCC 1:3:6 type C-2 frame cover MS funnel GI watering pipe incluing earth work for excavation and removal of surplus soil complete all as specified and as directed.
Material and Labour for concealed sub main wiring drawn through suitable PVC conduit pipe with two runs of 4.0 Sqmm PVC insulated, unsheated single core, multistranded copper conductor 1100 V grade, including PVC insulated 4.0 Sqmm copper connecting multistranded cable for earth continuity conductor to earth dolly complete all as specified and as directed.
Supplying and laying cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 25 sqmm 3.5 core complete all as specified and as directed.
FIRE ENVO SAFETY ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .