| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L3₹1.3 L+₹38,250 (29.9%)Accepted-AOC NEAR HANUMAN MANDIR WARD NO 14 BAWANI KHERA BHIWANI 127032 | BHIWANI | HARYANA | 127032 | ₹1.3 L+₹38,250 (29.9%) Quoted ₹1.7 L | L3 | Accepted-AOC Being agreed to execute the work on L1 rates |
| 2 | L1₹1.3 LRejected-AOC | ₹1.3 L | L1 | Rejected-AOC Denied to execute the agreement |
| 3 | L2₹1.6 L+₹27,053 (21.1%)Rejected-AOC | ₹1.6 L+₹27,053 (21.1%) | L2 | Rejected-AOC Denied to execute the work on L1 rates |
| 4 | L4₹1.7 L+₹39,889 (31.1%)Rejected-AOC | ₹1.7 L+₹39,889 (31.1%) | L4 | Rejected-AOC Being L4 |
| 5 | L5₹1.8 L+₹56,625 (44.2%)Rejected-AOC | ₹1.8 L+₹56,625 (44.2%) | L5 | Rejected-AOC Being L5 |
Tender Value
₹1.4 L
EMD Value
₹2,800
Closing Date
15 Mar 2022, 2:00 pmClosed
Executive Engineer W/S Div. No. 2
REWARI
Est. for repairing and fixing M.S Gate on JC-3 Pump house of Sub Division No. 5, Rewari.
2022_HRY_210341_5
923-40/29-A Dated 02/03/2022
Open Tender
Civil Works
Item-rate/Agreement basic
30 days
REWARI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹2,800
Yes
19 Mar 2024
4 Mar 2022
16 Mar 2022
4 Mar 2022
15 Mar 2022
4 Mar 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5m, as directed by Engineer-in-charge(all kind of soil).As per HSR item no.4.12.1
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level.1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) As per HSR Item no.6.1.6
Steel reinforcement for R.C.C. work, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level.(Mild steel and Medium Tensile steel bars).As per HSR Item no.6.34.1
Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement,1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) as per HSR Item no 6.15.1
Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand(As per HSR Item no.7.21.1)
Half brick masonry with common burnt clay non-modular bricks of class designation 7.5 in foundations and plinth in.cement mortar 1:4 (1 cement : 4 coarse sand).As per HSR Item no.7.27.2
CEMENT PLASTER (IN FINE SAND),12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand).As per HSR Item no.11.5.3
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).As Per HSR Item no.13.1.1
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications:Painting steel work with deluxe multi surface paint to give an even shade. Two or more coat applied @ 0.90 litre/10 sqm over an under coat of primer applied @ 0.80 litre/10 sqm of approved brand and manufacture.As per HSR Item No.11.97.3
Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade.As per HSR Item no.11.63
Light on gate 3 metres long 50 mm dia pole duly embedded 0.6 m below ground level AS per HSR item no 24.4.3
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required.1 run of Size 2.50 Sqmm(1.1.80mm).As per item no.23.5.6.2
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect.(5 amp 1 way switch ).as per HSR item no. 23.8.11.1
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect(5 amp Socket).as per HSR item no. 23.8.11.4
Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet(180 mm X 100 mm X 60 mm deep M.S. Box). As per HSR Item no.23.8.3.3
Havells LED flood light 30w, Rate approved vide Executive Engineer W/S Division No. 2,Rewari Letter no.5091-92/9A Dated 23/10/2020.LPA copy Attached
DRDYL Engineers Private Limited
THE BAWANI KHERA KHATU SHYAM CO-OP L&C SOCIETY LTD
The Bawani Khera Radha Swami Coop L and C Society Ltd
Sonu Yadav
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .