| 1 | 1₹27.0 LAccepted-AOC NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | 1 | Accepted-AOC Acceptance Of Tender | |
| 2 | 2₹28.3 L+₹48,254 (1.74%)Rejected-Finance 41 SAKOORPUR ROAD NEAR PRIMARY SCHOOL NEW JANKIPURAM NEELMATHA LUCKNOW CANTONMENT PO DILKUSHA LUCKNOW UP PIN 226002 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226002 | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹29.4 L+₹1.6 L (5.83%)Rejected-Finance | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹29.5 L+₹1.7 L (6.09%)Rejected-Finance | 4 | Rejected-Finance Not L1 | |
| 5 | 5₹30.9 L+₹3.1 L (11.2%)Rejected-Finance | 5 | Rejected-Finance Not L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Sept 2024, 6:00 pmClosed
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
REPAIR / REPLACEMENT AND MAINT OF DG SETS OF VARIOUS CAPACITIES WITH AMF PANEL AND LT PANEL OF VARIOUS CAPACITIES INCL AND OTHER MISC WORKS AT DIFFERENT PUMP HOUSES IN THE AREA OF AGE E/M EXT (WS) UNDER GE E/M LUCKNOW
2024_MES_668312_1
CWE/LKO/EM/T-47 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE E/M LUCKNOW
₹80,000
Yes
21 Nov 2024
30 Aug 2024
7 Oct 2024
30 Aug 2024
30 Sept 2024
13 Sept 2024
30 Aug 2024 - 13 Sept 2024
Amount
M&L for servicing / routine maintenance of DG Set from authorised rep or service engineer from the manufacturer of DG set of 30 KVA to 50 KVA capacity by entire cleaning of DG set, checking battery voltage, checking any Leakage, checking oil level, checking coolant level, checking V-Belt condition, cleaning of Air Filter, cleaning of radiator with appropriate chemical, checking of all electrical terminal & thimbles, checking pollution level complete all as specified & directed by Engineer-In-Charge, including replacement of following spare parts: - (a) Fuel filter (primary & secondary) (b) Oil filter (d) Bypass filter (e) Super bypass filter. Note: - Any other spare parts, if found unserviceable will be measured & paid separately as supply only. Replacement of engine oil & coolant if required to be replaced will be measured & paid separately as per direction of Engineer in Charge.
Supply only following spare parts of DG set of 30 KVA to 50 KVA capacity complete all as specified & directed. Note: - At site DG set of make Kirloskar / Cummins installed, make of spare parts if required to be replaced shall be as recommended by OEM and approved by GE
Air cleaner
Hose pipe set
Fan belt
Banjo bolt
Screen filter
Fuel injector pipe
Injector nozzles
Injector plunger and plunger spring
Tappet bush with packing
Valve guide and spring
M&L for servicing / routine maintenance of DG set of 63 KVA to 82.50 KVA capacity by entire cleaning of DG set, checking battery voltage, checking any Leakage, checking oil level, checking coolant level, checking V-Belt condition, cleaning of Air Filter, cleaning of radiator with appropriate chemical, checking of all electrical terminal & thimbles, checking pollution level complete all as specified & directed by Engineer-In-Charge, including replacement of following spare parts: - (a) Fuel filter (primary & secondary) (b) Oil filter (d) Bypass filter (e) Super bypass filter Note: - Any other spear parts, if found unserviceable will be measured & paid separately as supply only. Replacement of engine oil & coolant will be measured & paid separately
Supply only following spare parts of DG set of 63 KVA to 82.50 KVA capacity complete all as specified & directed. Note: - At site DG set of make Kirloskar / Cummins installed, make of spare parts if required to be replaced shall be as recommended by OEM and approved by GE
Air cleaner
Hose pipe set
Fan belt
Banjo bolt
Screen filter
Fuel injector pipe
Injector nozzles
Injector plunger and plunger spring
Tappet bush with packing
Valve guide and spring
M&L for taking out Fuel Injection Pump from DG set of 30 KVA to 50 KVA capacity, transporting to service centre / contractor workshop and over hauling / calibration including replacement of wornout parts such as screen filter, delivery valves, plunger, O-ring, spring rotor assemby, injector element, refixing in same position and testing complete all as specified and directed .
M&L for taking out Fuel Injection Pump from DG set of 63 KVA to 82.50 KVA capacity, transporting to service centre / contractor workshop and over hauling / calibration including replacement of wornout parts such as screen filter, delivery valves, plunger, O-ring, spring rotor assemby, injector element, refixing in same position and testing complete all as specified and directed .
S&F in replacement alternator (Dynamo) charger suitable for 12 Volt Battery of required make with all accessories i.e. fabrication of mounting brackets nut bolt etc suitable for DG set of capacity 30 KVA to 82.5 KVA including testing complete all as specified and directed.
Taking out of turbo charger from DG Set transportation to work shop for repairing and replacement of turbo charger kit & refixing to DG Set and testing complete all as directed by Engineer-in-charge for following capacity
(a) 30 KVA TO 50 KVA
(b) Above 50 KVA upto 82.5 KVA
M&L for dismantling and transporting to contractor's work shop of alternator by opening of nut bolts of base plate and coupling opening of front and rear cover removing of fan and removing of armature, rewinding of alternator by super enameled insulated copper wire as per existing gauge, insulating materials, varnishing, drying in hot oven up to desired temperature assembling and testing on connected load complete all as specified and directed by Engineer in charge of Cap 30 KVA to 82.5 KVA. Note : (Cost of transportation is deemed to be included in quoted rates)
(a) 30 KVA TO 50 KVA
(b) Above 50 KVA upto 82.5 KVA
NOTE FOR ITEM NO 1 to 33 :- (i) The name of service engineer/authorised rep of copany visiting the DG set shall be intimated by contractor in advance alogwith sate of servicing. (ii) The 'C' Check maint spares parts and engine oil etc shall be measured and paid separately in relavent items of schedule and any other check as per menufacturer's instructions & minor repair as directed by Engineer-in-charge shall deemed to be included in quoted rate of Schedule.
S&F lead acid battery 12 volt , 100 Ah, 25 plate with initial charging, fixed in position and connecting with terminal including taking down old battery and deposit in the storeyard of Engineer-in-Charge complete all as specified and directed. Note:- Guarantee Card, Literature and Users instructions shall be handed over to Engineer in Charge.
S&F lead acid battery 12 volt , 150 Ah, 25 plate with initial charging, fixed in position and connecting with terminal including taking down old battery and deposit in the storeyard of Engineer-in-Charge complete all as specified and directed . Note:- Guarantee Card, Literature and Users instructions shall be handed over to Engineer in Charge.
M&L for draining out old used oil from engine sump cleaning of sum and supply and filling new lubricating oil SAE grade ( 20 W 40) multiviscosity complete all as specified and directed .
M&L for top up for coolant / replacement of coolant by new coolant suitable for ambient temp from 15 to 40 degree centigrade complete all as specified and directed.
M&L for pouring distilled water superior grade in lead acid battery all as approved complete all as specified and directed .
M&L for taking out of burnt AVR system of DG set of capacity 30 to 82.5 KVA by opening connection chamber of alternator dismantling all existing electric / electronic connection replacement of AVR set reconnection checking of all circuit, testing the same up to the satisfaction of Engr-in-charge.
M&L for taking down unserviceable self starter 12 volt from DG set transproting to contractor workshop dismantling pinion etc rewiring of armature and field coil by suitable size of insulated copper wire, to achieve its original performance varnsishing replacement of pinion, pinion spring , carbo brush etc re- assmebling the same , testing and refixed to DG set and testing complete all as specfied and directed by EIC
M&L for replacement of solenoid switch of required make for auto on / off manual mode in the engine operation inclduing wiring complete all as specifed and directed by EIC .
S&F water pump assembly of required make for the DG set of capacity 30 to 82.5 KVA including dismentling of old water pump assembly complete all as specified & directed.
S&F in repair battery terminal heavy duty made out of brass suitable for 12 votls lead acid battery all as specified and directed by EIC
Material & labour for preparation of old painted surfaces by removing of dust and dirt by caustic soda or any other means, painting of DG set CAP 30 KVA to 82.5KVA of various capacity complete Canopy as per colour code by spray painting applied two coat of synthetic enamel paint over existing painted surface and marking of SM/MES No on the sets as per approved colour complete all as specified and directed directed by Engineer in Charge.
Daily Maintenance of AMF Panels of any make and model of D.G.Sets at various locations in Lucknow Cantt area by depolying one trademan including cleaning overhauling and repairs to defective AMF Panels after renewal of defective spares / components of any approved make as per existing or its equivalent complete all as specified & directed. [Note :(i) Each AMF Panel shall be cleaned /maintained under supervision of EIC (ii) Fixing of defective spares / Components are deemed to be included in the unit rate but cost of spares / components will be paid against items will be paid separately as listed here-in-after (iii) Daily maintenance register shall be maintained and shall be signed by representative of contractor and the Engineer in-Charge after doing necessary maintenance)
M&L for replecement of horness cable control wiring and testing complete all as specified and directed by Engineer in Charge
S&F on load change over switch cap 100 Amps 4 pole 415 Volts by addition/alteration in existing wall complete all as specified and directed by Engineer-in-Charge.
S&F on load change over switch cap 160 Amps 4 pole 415 Volts by addition/alteration in existing wall complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repairs electronic control timer type ET-100 of suitable capacity as required at site.
Supply & fix in repairs engine starter relay of suitable capacity as required at site.
Supply & fix in repairs under voltage relay
Supply & fix in repair four Pole Power Contactor -Type MCX-22, 100 Amps, 415V, 50 Hz Make-L&T
Supply & fix in repair three Pole Power Contactor -Type, MNX-95, upto 120 Amps, 415V, 50 Hz Make-L&T
Supply & fix in repair three Pole Power Contactor -Type, MNX-110, 120 Amps, 415V, 50 Hz Make-L&T
Supply & fix in repair three Pole Power Contactor -Type MNX-140, 160 Amps, 415V, 50 Hz, Make-L&T
Supply & fix in repair four/three Pole Power Contactor -Type ML-06 100 Amps, 415V, 50 Hz Make-L&T
Supply & fix in repair Single Phase Preventor Relay + Timer 415 Volt
Supply & fix outdoor type fountain light waterproof and RGB colour with 6 bulb, 18 watt LED, 12 volt, IP68 with fitting accessories all as specified and directed by Engr-in-Charge
S&F in repair 35 watt LED street light fitting 230 V AC, system lumen efficiency not less than 110 lumen / watt, outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-charge .
Repair/maint of LT Panel 3 phase AC 415V, 50 Hz of any make including Taking out old /UNSV MCCBs & MCBs /incoming and outgoing laminated copper busbar , DMC/epoxy insulators of any size ,Volt meter, Amp. meter,phase indicator LED lamp,Change over switch of any capacity ,burnt out copper winding ,current coil ,potential coil and keeping aside for safe custody for re-use, opening the L.T. Panel, removing gasket, dismantling and taking out old parts carefully, disconnecting all conections, & re-assembling all serviceable parts to original position including cleaning , removing sludge, dirt, dust, cleaning of parts including removal of old paint with 02 coat synthetic enamel paint after 01 coat iron red oxide paint along with replacement of nuts, bolts, thimbles, gasket etc as per site requirement including complete testing as per site requirement. , complete all as specified and directed by Engineer-in- Charge. Note : All spare parts and rewiring work will be measured and paid seperately under respective item of Sch 'A'.
S & F in repairs MCCB 160 Amps, 415 volts AC 50Hz, 4 pole, breaking capacity 36 kA ajustable thermal setting, Ics=100%Icu@ with suitable size of sheet metal enclosure complete all as specified.
S & F in repairs MCCB 200 Amps, 415 volts AC 50Hz, 4 pole, breaking capacity 36 kA ajustable thermal setting, Ics=100%Icu@ with suitable size of sheet metal enclosure complete all as specified.
S & F in repairs MCCB 100 Amps, 415 volts AC 50Hz, 3 pole, breaking capacity 16 kA ajustable thermal setting, Ics=100%Icu@ with suitable size of sheet metal enclosure complete all as specified.
Supply & fix in repair MCB TPN capacity 32 Amps, 415V, 50 c/s 16 KA, complete all as specified and directed by Engineer-in- Charge.
Supply & fix in repair MCB SPN capacity 32 amp, 'C' series , complete all as specified and directed by Engineer-in- Charge.
S & F in repairs MCB SP 6 to 40 Amps, 240 Volts of 'B' series to be housed in DBs and suitable size cable lugs to be fixed with MCBs as in replacment, complete all as specified and directed by Engineer-in- Charge.
Supply & fix in repair Set of indicating lamp LED type, complete all as specified and directed by Engineer-in- Charge.
Supply only Relay -4 PDT, 240V AC, 3A complete all as specified and directed.
Supply only Relay - 4 PDT, 24V DC, 3 Amp complete all as specified and directed.
Supply only push button with LED indicator with NO & NC contact 240 V AC, color : Red / Yellow / Green complete all as specified and directed.
Supply only of SMPS input volt 230V AC, Output volt 24 V DC and output current 3 Amp complete all as specified and directed.
Supply only of Limit Switch for Actuator Suitable for 80 mm /100mm/ 150mm /200mm dia size with 1 NO & 1 NC, 2 Amp complete all as specified and directed.
Supply only Handwheel for 80mm/100mm/150mm/200mm Actuators complete all as specified and directed.
Supply only Magnetic Float level sensor complete all as specified and directed.
Supply only Water Level Controller Relay Card (05 levels), having input volt 12 V DC & output 5V DC, 0.25 Amp rating complete all as specified and directed.
S&F in repair LED aviation obstruction Light fitting, double dome type, 2 x 5 Watt 230 Volts 50 Hz, yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories fixed over O/H Tank at height 21 Mtrs to 26 mtrs.
S&F in repair MCB DB single pole with neutral sheet metal enclosure, 240V,of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete without MCB, suitable for 02 way complete all as specified and directed by Engr-in-charge.
Supply and fixing of star delta starter fully automatic oil cooled with auto transformer and first filling of transformer oil complete with suitable size cable for connection between starter to auto transformer suitable for 20 to 30 HP, 3 Phase, 415 V electric motor including necessary connection and fixed on stand made out of angle iron 40 X 40 X 4 mm size including dismantling and taking out old star delta starter , complete all as specified and directed by Engineer-in-Charge.
S&F PVC insulated & sheathed , heavy duty electric cable on RCC Piller /Dome of over head tank at height of 26 meter approximatelly from normal ground level including fixing arrangement with Copper conductor, multi stranded 1100 volts grade flat 2 core 04 Sqmm and taking out of existing unserviceable cable complete all as specified and directed by Engr-in-charge.
Suppling, laying, fixing and testing only LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core laid in trenches/ under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing complete and taking out unserviceable cable, complete all as specified and directed by Engineer-in- Charge. Note : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per Sl No here-in-above but 35 Sqmm 3.5 core.
All as per Sl No here-in-above but 50 Sqmm 3.5 core.
Supply, installation, testing, commissioning & electrically connected feeder pillar outdoor type, single door compartmentized with locking arrangement canopy at top weather proof, vermin/dust proof of suitable size cubical type factory made of CRCA MS sheet 3.15 mm thick machine pressed of size 60x60x40 cm & angle iron frame 40x40x6 mm for legs and including grouted in PCC 1:2:4 type B1 (20 mm graded stone aggregate) suitable 440 volts AC 3 phase 4 wire bus bar 4 pole made out of suitable size copper strip capacity 200 Amps fully mounted on procelain insulator enclosed chamber with open able shutter both sides comprising with including taking out old Feeder pillar , complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete for electrical equipments with galvanized steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to earth lead of GI strip of size 32x6mm by means of nuts, bolts, check nuts & washers made of galvanized iron or steel and connected to main switch board or main control board as directed charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soilcomplete all other accessories as shown on electrical plate No 3 of MES SSR Part I including 40mm bore light grade GI pipe 1.8 mtr length with top end covered with plug or cap for watering and 30x30x30cm size PCC 1:3:6 block around watering pipe, excluding 20mm dia watering pipe, PCC, watering pit, funnel, pit cover complete all as specified and directed by Engr-in-charge.
M&L for earthing complete for electrical equipments with galvanized steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00mm by means of nuts, bolts, check nuts & washers made of galvanized iron or steel and connected to main switch board or main control board as directed charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soilcomplete all other accessories as shown on electrical plate No 3 of MES SSR Part I including 40mm bore light grade GI pipe 1.8 mtr length with top end covered with plug or cap for watering and 30x30x30cm size PCC 1:3:6 block around watering pipe, excluding 20mm dia watering pipe, PCC, watering pit, funnel, pit cover complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement six core, 1.5 sqmm nominal cross sectional area, multistranded armoured copper conductor cables, 1100 volts grade heavy duty cable PVC insulated and PVC sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified and directed.
Supply & fixing in replacement five pair, 0.5 sqmm nominal cross sectional area mulistranded copper conductor cables, PVC insulated and armoured PVC sheathed, laid in trenches/ laid under floor or fixed maked with walls / on poles/in ducts/in GI pipes etc complete all as specified and directed.
Supply, Installation, Testing and commissioning of motor actuated butterfly valve in replacement with the following specifications including all accessories mentioned as under (a) Valve size 250mm dia (b) Designed line pressure 4 kg/Sqcm (c) Operating Angle : 90 degrees (d) Disc material CI with nylon coating (e) Limit switches : 02 Nos for open and close (f) Mounting : Splash proof-Direct on valve (g) Input Supply : 230V, AC, 50 HZ (h) In built wireless modem compatibility for remote communication (j) Valve position indication with an output of 4-20m A (k) The actuator should be capable of accepting 4-20m A of input of regulating purposes (l) Mannual Operation : Hand Wheel
Supply, Installation, Testing and commissioning of motor actuated butterfly valve replacement with the following specifications including all accessories job mentioned as under (a) Valve size 150mm dia (b) Designed line pressure 4 kg/Sqcm (c) Operating Angle : 90 degrees (d) Disc material CI with nylon coating (e) Limit switches : 02 Nos for open and close (f) Mounting : Splash proof-Direct on valve (g) Input Supply : 230V, AC, 50 HZ (h) In built wireless modem compatibility for remote communication (j) Valve position indication with an output of 4-20m A (k) The actuator should be capable of accepting 4-20m A of input of regulating purposes (l) Mannual Operation : Hand Wheel
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 core nominal cross section in service connections
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide and geting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engr-in-charge.
Removing excavated material not exc 50 m and depositing where directed at a level not exc .5m above the starting point complete all as specified and directed by Engr-in-charge.
Supply and spread fine dry sand locally available for cable cushioning complete all as specified and directed by Engr-in-charge.
M&L for laying sub class 'B' brick in trenches as cable protection covers across the length of the cable complete all as specified and directed by Engr-in-charge.
M/S BHAGIRATHI ENTERPRISES (BID ID -3101449)
OM NAMAH SHIVAY ENTERPRISES (BID ID -3102562)
M/S NATIONAL ELECTRIC WORKS (BID ID -3102182)
MTR GROUP & COMPANY (BID ID -3102093)
NEXT POWER ENTERPRISES (BID ID -3101292)
Shree Kanth Technologies (BID ID -3102451)
Magneoflux (BID ID -3097252)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .