| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-Finance | ₹8.2 L | L1 | Accepted-Finance L1 |
| 2 | L2₹8.7 L+₹45,675 (5.54%)Accepted-Finance | ₹8.7 L+₹45,675 (5.54%) | L2 | Accepted-Finance L2 |
| 3 | L3₹9.0 L+₹72,140 (8.75%)Accepted-Finance PLOT NO F158 PHASE 8B INDUSTRIAL AREA MOHALI MOHALI MOHALI PUNJAB 160071 | S A S NAGAR | PUNJAB | 160071 | ₹9.0 L+₹72,140 (8.75%) | L3 | Accepted-Finance L3 |
| Sl No | Description | Qty | Unit | AAYANSH ELECTRICAL SOLUTIONS L1 | HIGH TECH ENGINEERS L3 | RAKSHA POWER INFRATECH L2 |
|---|---|---|---|---|---|---|
| 1.00Repairing/replacement of damaged protection relays at 18 Nos. 33/11 KV substations under Electricity Distribution Division, Hapur, including thorough inspection, testing, calibration, wiring, and commissioning of relays, and carrying out repair and maintenance of 33 KV VCBs, CT/PT units, control panels, and associated equipment; the work shall include fault diagnosis, servicing, tightening, replacement of minor defective components, cleaning, oiling/greasing (wherever required), restoration of control wiring, testing and proper functioning of all protection and control systems, and all allied works required for satisfactory operation of the substation. The rate shall be inclusive of all labour, tools & plants (T&P), testing equipment, consumables, minor materials, handling, and all incidental charges necessary to complete the work in all respects as per departmental standards and directions of the Engineer-in-Charge. | ||||||
| 1.01Carriage/transportation of departmental materials from Electricity store center Hapur to work site under the jurisdiction of EDC-Hapur, 33/11 KV Substation Approx. distance upto 50 Km. including loading, unloading, stacking, and safe handling at all stages of transit; the work shall be carried out for all types of materials with due care to prevent damage and shall include all labour, vehicles, fuel, tools & plants (T&P), and all incidental charges required to complete the work in all respects. | ||||||
| 1.02 | 33 KV LINE ISOLATOR 800A | 2 | Nos. | 2,200 ₹4,400 Lowest | 5,000 ₹10,000 | 2,500 ₹5,000 |
| 1.03 | 33 KV CURRENT TRANSFORMER 400/200/1 OR 200/100/1 | 4 | Nos. | 2,200 ₹8,800 | 2,000 ₹8,000 Lowest | 5,000 ₹20,000 |
| 1.04 | 11 KV POTENTIAL TRANSFORMER | 2 | Nos. | 2,200 ₹4,400 | 2,000 ₹4,000 Lowest | 5,000 ₹10,000 |
| 1.05 | ACSR / DOG PANTHOR CONDUCTOR | 167 | Mtr. | 10 ₹1,670 Lowest | 60 ₹10,020 | 15 ₹2,505 |
| 1.06 | Eraction and fixing and making connection of 33 KV line isolator 33 KV (800 Amp.) (as per RESPO Norms) at diffrent 33/11 KV substation were include making alignment, all required nut bolt, clamps, Lug, connector, wire and strip etc all labour,T&P, safe & Porper oprations Provided by contractor in all respects. | 2 | Nos. | 12,000 ₹24,000 | 8,000 ₹16,000 Lowest | 25,000 ₹50,000 |
| 1.07 | Erection, Fixing and Replacement of defective 33 kV Current Transformer (CT) of ratio 400/200/1 including dismantling of the faulty CT, supply (if required), installation, alignment, connection, testing, commissioning, and making the system operational, complete in all respects with all necessary labour, tools & tackles, and safety measures as per standard specifications. | 4 | Nos. | 2,500 ₹10,000 Lowest | 5,000 ₹20,000 | 41,000 ₹1,64,000 |
| 1.08 | Providing, fixing and replacement of defective 33 kV panel O/C + E/F IDMT relay with suitable retrofitting arrangement of approved makes such as Ashida, Schneider, C&S or equivalent, conforming to PVVNL standards and RESPO norms, including dismantling of the existing relay, installation, wiring, testing, commissioning and making the system fully operational as per directions of the site in-charge, complete in all respects with supply of all required nuts, bolts, clamps, lugs, connectors etc., along with all labour, tools & plants (T&P) and safety measures. | 7 | Nos. | 34,000 ₹2,38,000 | 30,000 ₹2,10,000 | 20,000 ₹1,40,000 Lowest |
| 1.09 | Providing, fixing and replacement of defective 33 kV panel master relay with suitable retrofitting arrangement of approved makes such as Ashida, Schneider, C&S or equivalent, conforming to PVVNL standards, including dismantling of the existing relay, installation, wiring, testing, commissioning and making the system fully operational as per directions of the site in-charge, complete in all respects with supply of all required nuts, bolts, clamps, lugs, connectors etc., along with all labour, tools & plants (T&P) and safety measures. | 3 | Nos. | 10,000 ₹30,000 | 6,000 ₹18,000 | 5,500 ₹16,500 Lowest |
Tender Value
₹9.5 L
EMD Value
₹9,470
Closing Date
11 May 2026, 12:00 pmClosed
SUPERINTENDING ENGINEER
SUPERINTENDING ENGINEER EDC HAPUR
FOR WORK OF REPAIRING OF DAMAGED PROTECTION RELAYS AT 18 NOS. 33/11 KV SUBSTATIONS AND MAINTENANCE/REPAIR WORKS OF 33 KV VCB, CT/PT, CONTROL PANELS AND ASSOCIATED EQUIPMENT UNDER O and M HEAD 2026-27 WITHIN THE JURISDICTION OF EDD-Hapur
2026_PVVNL_1142159_1
05(W)/EDCH/2026-27
Open Tender
Electrical Works
Item Rate
HAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SUPERINTENDING ENGINEER, EDC, HAPUR
₹9,470
25 May 2026
25 Apr 2026
11 May 2026
25 Apr 2026
11 May 2026
25 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Repairing/replacement of damaged protection relays at 18 Nos. 33/11 KV substations under Electricity Distribution Division, Hapur, including thorough inspection, testing, calibration, wiring, and commissioning of relays, and carrying out repair and maintenance of 33 KV VCBs, CT/PT units, control panels, and associated equipment; the work shall include fault diagnosis, servicing, tightening, replacement of minor defective components, cleaning, oiling/greasing (wherever required), restoration of control wiring, testing and proper functioning of all protection and control systems, and all allied works required for satisfactory operation of the substation. The rate shall be inclusive of all labour, tools & plants (T&P), testing equipment, consumables, minor materials, handling, and all incidental charges necessary to complete the work in all respects as per departmental standards and directions of the Engineer-in-Charge. | |||||
| 1.01 | Carriage/transportation of departmental materials from Electricity store center Hapur to work site under the jurisdiction of EDC-Hapur, 33/11 KV Substation Approx. distance upto 50 Km. including loading, unloading, stacking, and safe handling at all stages of transit; the work shall be carried out for all types of materials with due care to prevent damage and shall include all labour, vehicles, fuel, tools & plants (T&P), and all incidental charges required to complete the work in all respects. | - | - | - | - |
| 1.02 | 33 KV LINE ISOLATOR 800A | 2 | Nos. | - | - |
| 1.03 | 33 KV CURRENT TRANSFORMER 400/200/1 OR 200/100/1 | 4 | Nos. | - | - |
| 1.04 | 11 KV POTENTIAL TRANSFORMER | 2 | Nos. | - | - |
| 1.05 | ACSR / DOG PANTHOR CONDUCTOR | 167 | Mtr. | - | - |
| 1.06 | Eraction and fixing and making connection of 33 KV line isolator 33 KV (800 Amp.) (as per RESPO Norms) at diffrent 33/11 KV substation were include making alignment, all required nut bolt, clamps, Lug, connector, wire and strip etc all labour,T&P, safe & Porper oprations Provided by contractor in all respects. | 2 | Nos. | - | - |
| 1.07 | Erection, Fixing and Replacement of defective 33 kV Current Transformer (CT) of ratio 400/200/1 including dismantling of the faulty CT, supply (if required), installation, alignment, connection, testing, commissioning, and making the system operational, complete in all respects with all necessary labour, tools & tackles, and safety measures as per standard specifications. | 4 | Nos. | - | - |
| 1.08 | Providing, fixing and replacement of defective 33 kV panel O/C + E/F IDMT relay with suitable retrofitting arrangement of approved makes such as Ashida, Schneider, C&S or equivalent, conforming to PVVNL standards and RESPO norms, including dismantling of the existing relay, installation, wiring, testing, commissioning and making the system fully operational as per directions of the site in-charge, complete in all respects with supply of all required nuts, bolts, clamps, lugs, connectors etc., along with all labour, tools & plants (T&P) and safety measures. | 7 | Nos. | - | - |
| 1.09 | Providing, fixing and replacement of defective 33 kV panel master relay with suitable retrofitting arrangement of approved makes such as Ashida, Schneider, C&S or equivalent, conforming to PVVNL standards, including dismantling of the existing relay, installation, wiring, testing, commissioning and making the system fully operational as per directions of the site in-charge, complete in all respects with supply of all required nuts, bolts, clamps, lugs, connectors etc., along with all labour, tools & plants (T&P) and safety measures. | 3 | Nos. | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
Standbidnew05.pdf
Tender Documents • 0.69 MB
BOQ_2133264.xls
BOQ • 0.27 MB
TNo05DateExtend11052026.pdf
PDF • 0.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .