Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC C O GUPTA EMPORIUM AR BAZAR HAPPY VALLEY SHILLONG 793 004 | EAST KHASI HILLS | MEGHALAYA | 793004 | ₹3.6 Cr Quoted ₹3.7 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹4.2 Cr+₹53.2 L (14.5%)Rejected-Finance | ₹4.2 Cr+₹53.2 L (14.5%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹4.2 Cr+₹55.3 L (15.1%)Rejected-Finance CITY TOWER BUILDING ROOM NO 306 CIRCULAR ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | ₹4.2 Cr+₹55.3 L (15.1%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹4.8 Cr+₹1.2 Cr (32.0%)Rejected-Finance H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | ₹4.8 Cr+₹1.2 Cr (32.0%) | L4 | Rejected-Finance Not being lowest |
Tender Value
₹4.5 Cr
EMD Value
₹5.2 L
Closing Date
25 Aug 2022, 6:00 pmClosed
hief Engineer Shillong Zone
HQ Chief Engineer Shillong Zone Spread Eagle Falls Shillong 793001
ADDN/ALTN AND SPECIAL REPAIRS TO MD ACCN UNDER GE GUWAHATI
2022_MES_539538_1
CESZ/GUA/ OF 2022-23
Open Tender
Civil Works
Item Rate
365 days
As Per Tender document
As per NIT
2 documents required · 2 mandatory
₹2,000
Yes
GE Guwahati
₹5.2 L
Yes
19 Oct 2022
20 Jul 2022
27 Aug 2022
20 Jul 2022
25 Aug 2022
13 Aug 2022
21 Jul 2022 - 28 Jul 2022
Amount
Taking down the chowkhat or frames n exc 1.5 sqm (without taking off shutters from the frame) each complete all as specified and as directed.
Taking down the chowkhat or frames exc 1.5 sqm but n exc 4 sqm (without taking off shutters from the frame) each complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement mortar (one side only measured in cases where both sides are plastered) complete all as specified and as directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid and pointed in any mortar complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Dismantling of existing roof treatment including layer of bitumen felt, concrete padding and benching including hacking for key, scrubbing down with water complete to receive new roof treatment including rubbish off the premises (any thickness) and removing to distance 0.25 km to 0.5 km. complete all as specified and directed
Dismantling of ceiling boards (Fibre/Pulp/Plywood) of any thickness including cover fillets complete all as specified and directed
Dismantling of plain or corrugated sheets in roofing of any gauge and any thickness including Nainital or similar pattern roof covering complete all as specified and as directed.
M&L complete removal of existing treatment on wall/roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to ,make surface clean, free from dust, loose paint etc by skilled labour complete all as specified and directed
Surface excavation in soft/loose soil n exc 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed.
Excavation in trenches in soft/loose soil n exc 1.5 metre wide and not exc 1.5 metre deep and getting out including forming bottom surface for laying HT cable, foundations etc Complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading levelling watering and well ramming in layer not exceeding 25 cm thick complete all as specified and directed by Engr-in-charge.
Supply and laying dry sand cushioning for UG cable protection in trenches with fine river sand 9 cm before laying cable and 9 cm thick cover after laying the cable complete all as specified and directed by Engr-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cum in soft/loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed
Removing excavated soil not exceeding 50 m distance and depositing where directed at a level n exc 1.5 metre above the starting point complete all as specified and directed .
M&L hardcore of broken stones of gauge exc 63 mm but n exc 100mm, deposited, spread and levelled in layers n exc 15 cm thick watered and rolled/ rammed to a true surface complete all as specified and directed
M& L Cement concrete 1:4:8 Type D 2 (using 40 mm graded stone aggregate), in foundations, filling and mass concrete complete all as specified and directed
M& L Cement concrete 1:2:4 Type B 2 (using 40 mm graded stone aggregate) ,as in surface channel and drain complete all as specified and directed
Extra for forming fair finished drain or channel 30CM inner girth in cement concrete using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and directed
Add or deduct for each 25 mm girth or part thereof over or under 30cm in Item No 21 above
M &L Brickwork with subclass 'B' old size bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified and directed
M&L Brickwork with subclass 'B' bricks, old size brick straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed
M&L for brick protection cover to underground cable with sub-class ‘B’ old size over burnt bricks laid dry and flat across the axis of cable, abutting each other with gaps between adjacent bricks not exceeding 10mm complete all as specified & directed.
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15 mm thick screed bed in 1:6 CM complete all as specified and directed.
S & F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part- I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supply & fixing in the frame at site as per specification & drawing.
M & L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supply & fixing in opening as per specification
S&F 150mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed
S&F 100mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed
S&F butt hinges of 100 mm size, medium weight, cold rolled mild steel and fixed, complete all as specified and directed
S&F 100 mm Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, typeB-11 complete all as specified and directed
S & F butt hinges, extruded aluminium alloy of size 100mm complete all as specified and directed
S&F in repair brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified .
S&F 150 mm aluminum handle cast type anodized, complete all as specified.
S&F 100 mm aluminum handle cast type anodized, complete all as specified.
S&F framed work such as grills gratings, etc., with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed baluster; walk ways; railings; framed work or water tanks and similar work conforming to Fe 290 gde E 165 complete all as specified and directed
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240 complete all as specified and directed
S&F, powder coated (minimum 15 micron thickness), Aluminium Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.including handle,tower bolt, door stoper, grill etc complete all as specified and directed
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed
M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed
M & L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified fixing 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed
M&L150 mm thick cement concrete type B-2,1:2:4 (40mm graded aggregate) as in path complete all as specified and directed
M&L for 75 mm 1:3:6 type C2 ( using 40 mm graded stone aggregate) as plinth protection/ paving finish even and smooth without using extra cement complete all as specified and directed.
M&L75 mm thick cement concrete type D-2,1:4:8 (40mm graded aggregate) as in path complete all as specified and directed
M&L 25 mm thick PCC B-0, 1:2:4 (12.5 mm graded aggregate) as in PCC underlayer complete all as specified and directed.
M&L 40 mm thick cement concrete type B-0,1:2:4 (12.5mm graded aggregate) as in padding complete all as specified and directed
M&L white Glazed ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed.
M & L Non - skid Ceramic tiles 7 to 8 mm thick, white coloured, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed.
M & L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, light shade, area of each tiles not exc. 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed.
M & L Non - skid Ceramic tiles 7 to 8 mm thick white coloured area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed.
M&L for pre polished Chequered cement concrete coloured tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigment in floors and jointed with grey cement slurry mixed with pigment to match over 20 mm thick screed bed or bedding of cement mortar (1 : 6) complete all as specified and directed
M&L for rendering 15 mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surface of walls finished even and fair complete all as specified and directed
M&L for rendering 15 mm thick in cement mortar 1:6 on other than fair faces of brick work or concrete surface of walls finished even and fair complete all as specified and directed
M & L for rendering 5mm thick in cement mortor (1:3) on ceiling finish even and smooth w/o using extra cement complete all as specified and directed
M&L for Screed bed or bedding layer CM (1:4) of mortor 15mm thick for laying floor finish complete all as specified and as directed.
M & L Screed bed or bedding layer of cement mortar(1:6) 20 mm thick for laying floor finishes complete all as specified and directed
M&L preparation of new surface of wall and apply two coat of oil bound distemper over one coat of primer over 1.5 mm thick wall care putty complete all as specified and directed
M&L complete removal of existing treatment on ceiling and applying two coat of oil bound distemper over one coat of primer over 1.5 mm thick wall care putty complete all as specified and directed
S&F 4 mm thick Sheet glass, ordinary quality, and glazing in square n exc 0.5 sq. m in each pane complete all as specified & as directed.
M&L for preparation of new wooden surfaces of any description, over 10cm in width or girth, not otherwise described, and applying two coats of synthetic enamel paint (1st quality) over a priming coat of pink primer complete all as specified and directed
M&L preparing new steel surface of any description not otherwise described for over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F concealed sliding window lock latch complete all as specified and as directed
M& L Prefabricated full body granite light beige stone, granite stone, size : 20 x120cm , Step and Riser tiles with double bullnosing for edge protection and self embossed treadlines for skid resistance for staircases having abrassion resistance PEI-4 & above & surface hardness MOH-6 & above, breaking strength of >5000N, skid resistance >R9 as per DIN51130, Flexural Strength of >38N/mm2 minimum stain resistance of Class 3 (ISO-10545-14) and Class 1 (BIS 13630-8) confirming to IS 15622:2017 and acid resistance as per IS 4457:2007, complete all as specified and as directed.
S&F 50 mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid in trenches, road crossing, drain crossing, under floor or fixed to iron structures/poles complete all as specified and directed.
M&L for 15mm bore GI Pipe medium grade with all fitings and fixed to wall and ceiling or laid in floor including taking down of old fitting complete all as specified and directed
M&L for 20 mm Tubes, 'Medium grade', galvanised, with all fitting; and fixed complete to wall and ceiling or laid in floors including taking down of old fitting complete all as specified and directed
S&F in repair 15 mm Bib taps, cast copper alloy fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
Supply and fixing of 3- layer PP-R ( Polypropylene random copolymer) concealed pipes 20mm outer dia,SDR 7.4 (PN-16) pipe UV stabilized and antimicrobial fusion welded having thermal stability for hot anf cold water supply all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings/trenches or in floors etc. complete all as specified and directed.
Supply and fix PPR Gate Valves (Brass Insert) of 20 mm bore complete all as specified and directed.
Supply and fix in repair rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR- Part-I 500 Litres capacity complete all as specified and directed
S&F in repair 15 mm Stop valves(Concealed type), cast copper alloy,fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed
S&F PVC (SWR) 75mm bore Pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed
S&F PVC (SWR) 110mm bore Pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed
S & F 75mm bore PVC (SWR) bends complete all as specified and directed
S & F 110mm bore PVC (SWR) bends complete all as specified and directed
S&F in repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed
S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed
S&F Vitreous China wash down water closet pan (pedestal pattern), white including PVC valveless, syphonic action type, flushing cistern, 10 Ltr capacity low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed
S&F vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including PVC valveless, syphonic action type, flushing cistern, 10 Ltr capacity low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed
M&L for one coat of acrylic water based exterior grade primer @0.9 ltr (undiluted)/10 Sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed.
M&L for waterproof cement based putty @ 1 Kg(undiluted) per Sqm of average thickness 1 mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:- Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI Step 3) Allow 6-8 hrs time to dry the putty surface.
M&L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI, Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed.
Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm using automatic airless spray machine over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
M&L for applying two coats of Acrylic distemper including a coat of primer using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. Note For Item No 90 to 94: - (a) Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. (b) The contractor shall submit the MoU letter from paint manufacturer and also with their authorized applicator as specified in tender within 15 days of commencement of work. (c) The work pertaining to periodical services shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer. (d) Cost of scaffolding upto 10m height of building shall be included in quoted rate. (e) Contractor shall submit approved generated warranty card from paint manufacturer at the time of submission of RAR & final bill. (f) Authorised applicator of paint manufacturer shall have valid authorization letter from the manufacturer (minimum regional HQ ) issued not earlier than 30 days from start date of said finishing work. The authorisation letter needs to also be valid for the complete period of execution.
M& L for bituminous primer @ 0.30 Kg/Sqm over the cement plaster including preparation of surfaces as per manufacturers instruction complete all as specified and as directed by the Engr-in-Charge.
S&F in repair 15 mm angular stop cock with wall flange complete all as specified and as directed by the Engr-in-Charge.
S&F in repair 15 mm two way Bib cock with flange complete all as specified and as directed by the Engr-in-Charge.
S&F hand shower (health faucet)(ABS Body) with 8mm dia, 1.2 meter long flexible tube & wall hook complete all as specified and as directed by the Engr-in-Charge.
S&F in repair reflection looking mirror of size 600x450mm fixed to wall with chromium plated brass screws and cup washers complete all as specified and as directed by the Engr-in-Charge.
Supply and fix 0.63mm thick 24"x31"x10" Stainless steel kitchen plate rack fixed with chromium plated brass screws and cup washers complete all as specified and as sdirected.
Taking down carefully aluminum/ copper point wiring (light, fan, socket or power) complete (excluding sunken box) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good to disturbed surfaces of walls, floors, ceilings etc. complete all as specified and as directed.
Taking down carefully unservicieble main switch and DB's including MCBs of any size, type and capacity . complete all as specified and as directed.
M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC Concealed conduit, medium grade minimum dia of 20 mm, ISI marked and conduit accessories fixed on recesses of wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.2 mm MS sheet, 3mm thick Modular top cover for mounting of modular fittings, switches, sockets outlets, regulators etc complete including provisining of 1.5 sqmm PVC insulated unsheathed FRLSH cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for One light/ceiling /exhaust fan/bell buzzer point controlled by one, one way switch complete all as specified and directed
M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC Concealed conduit, medium grade minimum dia of 20 mm, ISI marked and conduit accessories fixed on recesses of wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.2 mm MS sheet, 3mm thick Modular top cover for mounting of modular fittings, switches, sockets outlets, regulators etc complete including provisining of 1.5 sqmm PVC insulated unsheathed FRLSH cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for One light point controlled by two 2way switches complete all as specified and directed
M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC Concealed conduit, medium grade minimum dia of 20 mm, ISI marked and conduit accessories fixed on recesses of wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.2 mm MS sheet, 3mm thick Modular top cover for mounting of modular fittings, switches, sockets outlets, regulators etc complete including provisining of 1.5 sqmm PVC insulated unsheathed FRLSH cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for One bell/buzzer point controlled by one push button on the same board complete all as specified and directed
M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC Concealed conduit, medium grade minimum dia of 20 mm, ISI marked and conduit accessories fixed on recesses of wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.2 mm MS sheet, 3mm thick Modular top cover for mounting of modular fittings, switches, sockets outlets, regulators etc complete including provisining of 1.5 sqmm PVC insulated unsheathed FRLSH cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed
M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC Concealed conduit, medium grade minimum dia of 20 mm, ISI marked and conduit accessories fixed on recesses of wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.2 mm MS sheet, 3mm thick Modular top cover for mounting of modular fittings, switches, sockets outlets, regulators etc complete including provisining of 1.5 sqmm PVC insulated unsheathed FRLSH cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for One 3 pin 5 Amps socket outlet on independent board complete all as specified and directed
M&L for concealed point wiring complete with 4.0 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC Concealed conduit, medium grade minimum dia of 20 mm, ISI marked and conduit accessories fixed on recesses of wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.2 mm MS sheet, 3mm thick Modular top cover for mounting of modular fittings, switches, sockets outlets, regulators etc complete including provisining of 4.0 sqmm PVC insulated unsheathed FRLSH cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed
M&L for Concealed sub main wiring using two single core 10 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLSH) ISI marked drawing in and including 20mm dia rigid non metalic PVC conduit/casing capping & accessories like bends, tee, etc fixed on recess of wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of conduit with accessories shall be measured as one length
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix 10W LED Bulkhead light,pressure die cast housing LED bulkhead with IP65 Protection and IK09 Impact resistance suitable for surface/wall mounted,complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F 9 W LED Decorative, wall mounting, brushed nickel finish fixture with Oval Glass diffuser suitable with 9 W LED lamp B22 base suitable for mounting on wall/surface , including necessary connection complete all as specified and directed.
S&F Call bell, Ding Dong AC 230 volts,single pole complete all as specified and directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F Modular switch one way 5/6 Amp,1 module, 240 Volts complete all as specified and directed.
S&F Modular switch two way 5/6 Amp,1 module, 240 Volts complete all as specified and directed.
S&F Modular Bell push 6 Amp,1 module, 240 Volts complete all as specified and directed.
S&F Modular socket 2/3 pin, 6 Amps,2 module 240 Volts complete all as specified and directed.
S&F Switch socket Combination 16A, 6 pin, 3 module 240 volts complete all as specified and directed.
S&F ceiling rose surface bakelite two to three terminal 65 x 50 mm three terminal 250/230 volts ISI marked complete all as specified and directed.
Supply and fixing fan step regulator,120W ,2 Module A/C 240 Volts complete all as specified and directed.
S&F Factory made board distribution in sheet steel enclosure double door glazed with 200 Amps rated bus bar, SPN, 8 ways, 415 Volts suitable for housing MCBs complete all as specified and as directed.
S&F in repair MCB, SPN, 240 volts, C Curve, 63 Amps 10 KA complete all as specified and as directed.
S&F MCB, SP, 240 volts, 20-32 Amps 10 KA, C Curve, complete all as specified and as directed.
M&L earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground earth pit not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note:- Rate quoted by tenderers shall be deemed to include for following provisions- (i) Excavation & earth work in any type of soil including removing of surplus material upto 50 m. (ii)PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles. (iii) Main earthing lead from earth electrode to test point upto 7.5 mtr. (iv) Funnel with watering pipe GI pipe 20mm bore medium grade & copper lugs, charcoal & salt as required. (v). GI protection pipe of size 15 mm bore light grade 7.5m complete all as specified and as directed.
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and as directed.
Supply and fix ceiling fans, with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
M&L for 32 mm bore light grade GI pipe fixed as bracket, on wall any type, not less than 1.5 m long and bent to shape as required with sutiable clamp made out of 25x4mm Flat iron duly fixed 12mm dia nuts, bolts, washers etc. complete all as specified and directed by Engineer-in-Charge.
S&F sheet steel enclosure distribution box of size (1500mm x 1000mm ) 3.15 mm thick to accommodate 08 nos Digital Energy meter and 200 Amps rated bus bar enclosed with double door, including one 100 Amps MCCB,4 pole, breaking capacity 36KA as a incomer and Earthing terminal.Distribution box shall be fixed in wall including wall cutting,sinking of box and making good of surface complete all as specified and as directed.
S&F White cover plate with frame,1 module complete all as specified and as directed.
S&F White cover plate with frame,3 module complete all as specified and as directed.
S&F White cover plate with frame,6 module complete all as specified and as directed.
S&F modular metal flush box 1 module complete all as specified and as directed.
S&F modular metal flush box 3 module complete all as specified and as directed.
S&F modular metal flush box 6 module complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.0 sq mm 4 core
N.V.ENGINEERING
M/S ALLIED CONSTRUCTION
M/S. SUBHAS CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .