Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.8 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹49.4 L+₹56,991 (1.17%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹49.5 L+₹66,359 (1.36%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹49.5 L+₹66,680 (1.37%)Rejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹50.7 L+₹1.9 L (3.92%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
3 Aug 2020, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR MAINT TO INTERNAL ELECTRIFICATION FITTINGS FIXTURE AND ALLIED WKS INCLUDING DAY TO DAY MAINTENANCE PERTAINING TO MISC E M WORKS IN OTM ACCN AND TECHNICAL AREA AT AF STN SULUR
2020_MES_360983_1
8333/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹99,000
Yes
14 Aug 2020
14 Jul 2020
4 Aug 2020
14 Jul 2020
3 Aug 2020
28 Jul 2020
14 Jul 2020 - 27 Jul 2020
Amount
SCHEDULE A BOQ
Repair, maintenance and making the continuity of supply after rectifying the defects of the electrical items such as light point, fan point, call bell, point, socket point 5A/15A, switches, sockets, regulator, lamp holder, brackets, bell, buzzer, push button, batten, ceiling rose, pandent, any type of MCB's, DB's any type of light fixtures, any type of lamp, ceiling fan, exhuast fan, geyser, capacitor, replacement of fuse wires and all elcectrical accessories in day to day/door to door maintenace including S&F of small pieces of elctrical cable of size upto 10 sqmm single core and length not exceeding 0.50m complete all as specified and as directed. Note : Any major items required to be repaired will be measured under relevant items.
Note:- following shall be part of job under this item :-
(a) The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced before commencement of work.
(b) All bldg light complaints including service connection, submain & internal electric for OTM accn and entire Tech area of AF Stn sulur shall be attended.
(c) Record of complaints/complaint slip showing qtr No, bldgs No, nature of job supported with users signature shall be prepared as per format directed by Engr-in-charge & will be deposited to concerned JE E/M within 24 hrs.
(d) Necessary complaints slip/complaints register & other stationary required shall be contractor responsibility.
(e) All sort of petty T&P items such as PVC insulation table, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
(f) Defective items if any, required to be replaced shall be measured and paid as supply only separately, however labour component shall be part of this item.
(g) Pointwiring, sub main wiring, DB's, earthing & conduit etc specifically mentioned as M&L, S&F shall be measured and paid seperately.
(h) The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
(j) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(k) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(l) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only for Ceiling rose 3 plates flush type 6 Amps,250 volts AC ISI marked,
Supply only lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
Supply only PVC gang box 1 way 05 amp . Make. Cona/SSK/Anchor
Supply only switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
All as per item No 18 here-in-before but 15 Amp Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Supply only PVC rectangular/square block 75mmx75mmx35mm
Supply only electronic fan regulator 230 volts, step type socket type, hum free 100/240 watt. Make : Havells / Schnieder/ crabtree
Supply only Electronic ballast for 2 x 36/40 W flourecent tube light fittngs, 230V, Make : Sumo Slim EBE 236 TLD 240 of Philips or equivalent of Bajaj/CG
Supply only elctric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/ cona/ Plaza
Supply only shuttered socket outlet 3 pin 5 amps, flush type
Supply only shuttered socket outlet 2 in 1, 5 pin, 5 and15 amps
Supply only switch socket combination out let 3 pin 5 amps, flush type.
Supply only switch socket combination out let 5 in 1, 5 pin 5 and 15 amps, flush type.
Supply only modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular Socket, 16A - 3/5 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only moduler white cover plate with frame,3 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only moduler white cover plate with frame,4 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only moduler white cover plate with frame,6 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular switch 1 way 32 amp.2 module Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only Electronic ballast for 36/40 W flourecent tube light fittngs, 230V, Make : Sumo Slim EBE(Slim) 136 TLD 240 of Philips or equivalent of Bajaj/Crompton Greaves (CG)
Supply only starter for 40W flourecent tube light fittngs 1x40 /2x40 watts 230V. Make : Philips/ Bajaj/ CG
Supply only 7 watt LED lamp complete all as specified and directed. Make : Philips/ Bajaj/ Crompton Greaves
Supply only 2.5 mfd condensor for ceiling fan complete all as specified and directed. Make : Epcos/ Asian/ Tyton
Supply only electric buzzer, AC 230 volt, single pole complete all as specified and directed. Make : Anchor/ cona/ Plaza
Supply only 4' 20W/ 18W LED tube rod suitable for existing fitting. Make : Philips, Bajaj, Havells
Supply only insulation tape 25 mm width 10m long
Supply only of energy saving lamps 2W/3W/5W SUODI LIGHTING day light spiral type. Make : Philips/ Crompton Greaves/ Bajaj
Supply only bell push Make : Anchor/ Cona/ Havells
Supply only PVC gang box 2 way 05 amp . Make. Cona/SSK/Anchor
Supply only metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls. Make : Cat Pt No 607841 of Legrand or equivalent of Schnieder (Multi -9) or Siemens/L&T (Hegar).
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 sqmm 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza
Supply only plug top 3 pin 5 amps AC 230 volts complete all as specified and directed. Make : Havells/ Cona/ Plaza
Supply only bakelite sheet not less than 3 mm thick of size 100 x 100 mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
Supply only TPN, MCB 20 to 32 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Siemens/ Schneider/ L&T.
Supply only single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified (Make/Model : Lexic MCB of MDS Legrand Cat No :408587 to 408595 / Siemens/ Schnieder.
Supply only electronic fan regulator modular typre 230 volts, step type socket type, hum free 100/240 watt Make : Havells / Schnieder/ Crabtree.
Supply only switch socket combination outlet 5 in 1/ 5 pin 5 and 15 amps flush type with box
Supply only Electronic ballast for 1x18 W flourecent tube light fittngs, 230V, Make : Philips or equivalent of Bajaj/CG
Supply only Electronic ballast for 2 x 18 W flourecent tube light fittngs, 230V, Make : Philips or equivalent of Bajaj/CG
Supply only PVC gang box 2 way 15 amp . Make. Cona/SSK/Anchor
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 4 sqmm of 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.
Supply only plug top 3 pin 15 amps AC 230 volts complete all as specified and directed. Make : Havells/ Cona/ Plaza
Supply only bakelite sheet not less than 3 mm thick of size 175 x 100mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
Supply only bakelite sheet not less than 3 mm thick of size 200 x 200mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
Supply only rigid, non-matalic, PVC conduit pipe, ISI marked, 25 mm bore, including bends, saddles, accessories complete all as specified and as directed. Make : Prince/ Supreme/ Diplast
Supply only PVC batten of 15 mm (width) complete all as specified and directed. Make : Avon Plast/ Supreme/ Presto Plast
Supply only copper thimble pin type suitable to fix in MCB with sub circuit wires complete all as specified and directed.
Supply only LED bulb (Green colour) 15Watt B22 holder based Make : Philips, Bajaj or CG
Supply only 10 watt LED lamp complete all as specified and directed. Make : Philips/ Bajaj/ CG
Supply only 4 mfd condensor for ceiling fan complete all as specified and directed. Make : Epcos/ Asian/ Tyton
Supply only cordless bell musical type, AC 230 volt single pole, complete all as scpecifed and directed. Make : Anchor/ cona/ Plaza
Supply only switch socket combination outlet 3 in 1/ 3 pin 3 and 5 amps flush type with box
Supply only bakelite sheet not less than 3 mm thick of size 200 x 250mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
Supply only bakelite sheet not less than 3 mm thick of size 250 x 300mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
Supply only TPN, MCB 40 to 63 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Siemens/ ABB/ Legrand.
Supply only PVC batten of 20 mm (width) complete all as specified and directed. Make : Siemens/ ABB/ Legrand.
Supply only PVC batten of 25 mm (width) complete all as specified and directed. Make : Siemens/ ABB/ Legrand.
Supply only rigid, non-matalic, PVC conduit pipe, ISI marked, 32 mm bore, including bends, saddles, accessories complete all as specified and as directed. Make : Siemens/ ABB/ Legrand.
Supply only MS machine screw 25mm long of dia not less than 5 mm complete all as specified and directed
Supply only MS machine screw 50mm long of dia not less than 5 mm complete all as specified and directed
Supply only LED bulb (Red colour)15Watt B22 holder based Make : Philips, Bajaj or CG
Supply only Double pole MCB 40 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Siemens/ ABB/ Legrand.
Supply only of 4 pin 9 watt CFL. Make: Crompton Greaves/ Havells/ Osram
Supply only of 4 pin 36 watt CFL. Make: Crompton Greaves/ Havells/ Osram
Supply only electronic fan regulator 230 volts, step type, switch type, hurm free 100/ 240 watt Make : Anchor/ Cona/ Havells
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 1.5 sqmm of 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.
Taking down carefully medium bay lights at hangers for repairs, replacement of defective spare parts such as ballast, lamp holders, lamp, capacitor, ignitor etc of capacity 150/250/400 watts HPSV/HPMV/MH including cleaning internally and externally fixing back the fitting in same position after repair and test. (Note :- New spare parts shall be measured and paid separately)
Note:- following shall be part of job under this item :-
(a) The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced before commencement of work.
(b) All bldg light complaints including service connection, submain & internal electric for OTM accn and entire Tech area of AF Stn sulur shall be attended.
(c) Record of complaints/complaint slip showing qtr No, bldgs No, nature of job supported with users signature shall be prepared as per format directed by Engr-in-charge & will be deposited to concerned JE E/M within 24 hrs, failing which a sum of Rs. 50.00 per day will be recovered from the contractor.
(d) Necessary complaints slip/complaints register & other stationary required shall be contractor responsibility.
(e) All sort of petty T&P items such as PVC insulation table, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
(f) Defective items if any, required to be replaced shall be measured and paid as supply only separately, however labour component shall be part of this item.
(g) Pointwiring, sub main wiring, DB's, earthing & conduit etc specifically mentioned as M&L, S&F shall be measured and paid seperately.
(h) The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
(j) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(k) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(l) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only electronic LED driver 36W suitable for 2' x 2' ceiling light indoor fitting of make Philips/ Luker/ Wipro/ Bajaj as directed by Engineer-in-Charge.
Supply only ignitor suitable for HPSV/ HPMV/ MH fitting of wattage 150/ 250/ 400 watts. Make : Bajaj/ CG/ Philips.
Supply only 33 mfd capacitor suitable for HPMV/ HPSV/ MH light fitting.
Supply only high wattage metal halide lamp in elliptical / tubular shape of 400 watts. Make : Philips / Bajaj/ Wipro
Supply only Mercury / Metal Halide lamp ballast with copper winding polyster filling and voltage taping at 220/240V for 400 W HPMV fittings Cat Part No BHL 400 X 261 of Philips or Bajaj/ Crompton Greaves
Supply only 20 mfd capacitor suitable for HPMV/ HPSV/ MH light fitting.
Supply only Mercury / Metal Halide lamp ballast with copper winding polyster filling and voltage taping at 220/240V for 250 W HPMV fittings Cat Part No BHL 250 X 261 of Philips or equivalent in Bajaj/ Crompton Greaves
Supply only high wattage metal halide lamp in elliptical / tubular shape of 250 watts. Make : Philips /Bajaj/ Wipro
S&F LED Highbay Light, 200 Watts with housing –IP65 and IK07, circular high pressure die cast aluminum housing and manufacture logo embossed on the housing and High transmittance tempered glass cover, Optics-Lens with lens plate having NB & WB Optics, system efficacy->115 lumens/watt, Xitanium driver – IP66 complying to IEC- 61347 – 2- 13 Certification like CE, ENEC, ROHS, with rated life of 50000Hrs for driver at TC-80 deg C along with all safety features –Thermal protection, voltage range is 90 - 295 Volt,surge protection 4 KV, protection against input over voltage<320 VAC for 48 Hrs, Driver failure rate<0.2% per 1 Khr @ TC 70-80 Deg C, driver efficiency -93% at Max Load, internal wiring –Teflon, SDCM<5, CCT-5700, CRI>80, THD<20 at Max load , Third harmonics <20%, PF>.95 fixed complete all as directed at site.(Make: Philips Cat Part No 415P LED145S CW NB FG PSU GR S2 or eqvt Bajaj/ Wipro Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
S&F integrated LED bulk head luminarie fittings in engineering plastic housing with clear prismatic /opal diffuser /pressure aluminium die cast housing in white powder coating minimum IP-65 protection, system wattage not more than 10 watt (lumen output not less than 800 lumen) power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm. Make : Philips Cat part NO.WT202WLED6S NW PSU S2 PC or equivalent in Wipro/ Bajaj. Notes:- 1. The Contractor shall submit test report from manufacturer of LED fittings giving detail of each parameter /specifications of led luminaire mentioned in the BOQ item. 2. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 3. The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
M&L for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 107 here in before but for one 3 pin socket out 5 amp on the same board
All as per item No. 107 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 107 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing Caping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
One light point/fan/bell point controlled by one switch
All as per item No. 112 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 112 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 112 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F in replacement factory made powder coated distribution board SP & N 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens or equivalent of Schnieder & Legrand
S&F in replacement factory made powder coated distribution board TPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens or equivalent of Schnieder & Legrand
S&F in replacement on distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified. Make : Siemens/ L&T/ ABB
S&F metal clad switch socket triple pole and earth encolsure with three pin and earth plug with socket complete with on triple pole 32 Amps, 415 Volts MCB.Make :- Legrand /Siemens/ Schnieder.
Supply and Fixing in replacement indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED T8 batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 4feet (appx) size, high efficiency electronic driver, system wattage 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 3KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and directed. Make : Philips CAt part NO.85395000 /Wipro cat part No. LL13-181-650 for rod and WIO921208 or equivalent in Bajaj
Notes :- (a) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved. (b) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (c) The contractor shall submit warranty certificate from manufacturer for minimum 02 year.
S&F LED retrofit lamp 5W, warm white, (lumen output not less than 1350 lumens) with B-22 holder base with thermal conductive engineering plastic white colour housing and aluminium heat sink with specially designed fins clear /cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation all as specefied and directed. Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2. The contractor shall submit warranty certificate from manufacturer for minimum 2 years Make : Wipro cat part No. LL20-111-XXX-65NE3 or equivalent of Philips/ Bajaj
S&F LED retrofit lamp 20W, warm white, (lumen output not less than 1350 lumens) with B-22 holder base with thermal conductive engineering plastic white colour housing and aluminium heat sink with specially designed fins clear /cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation all as specefied and directed. Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2. The contractor shall submit warranty certificate from manufacturer for minimum 2 years Make : Wipro cat part No. LL20-111-XXX-65NE3 or equivalent of Philips/ Bajaj
S & F in 18 watt recess mounted sleek square downlighter enviornment friendly, new generation, energy saving with high power LED as light sources & clear glass inlcuding accessories all as specified and directed by Engr-in-Charge. Make /Model : Philips cat part No.DN 295B LED16S-6500 PSU WH/Wipro/ Bajaj. Note : 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Supply and fixing out door type wall light 1x3 W LED fitting including necessary wiring arrangement complete all as specified and directed. Make LUKER. Cat part No. LODARCS-3D/ Wipro/ Philips
Supply and fixing out door type wall light 2x3 W LED fitting including necessary wiring arrangement complete all as specified and directed. Make LUKER. Cat part No. LODARCD-6D/ Wipro/ Philips
M&L for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through Steel conduit with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lups) only.
One light point/fan/bell point controlled by one switch
One switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No-130 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC Conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F in replacement of convetional type boolard fitting with LED bollard light fittings suitable for 1x9 watt LED bollard in rectangular shaped vicotria design with opal acrylic diffuser and IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed. Make /cat part No. CG cat no.LBLSN-10-CDL /Bajaj Cat Part No. BGBOS 600 9W LED /philips.
S&F in replacement factory made powder coated distribution board TPN, 4 way single door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens or equivalent of Schnieder & ABB
M&L for wiring for circuit complete submain wiring with 2 X1.5 sqmm single core PVC insulated, unsheathed FRLS 100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl 1.5 sqmm single core wire PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing sub main wiring of any size and all as specified. Note :- Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Integrated solar street light of less than 18W with 3000 lumen and system lumen efficiency of more than 170 lumen per watt. The luminaire shall use highly efficient microcontroller based integrated MPPT charge controller, both charger and driver to be on same board with more than 90% efficiency of both charger and driver. High grade aluminium die-cast housing to ensure good heat dissipation. The luminaire shall have flexi mount of 0 to 15 degree to adapt to certain geography diversity. The luminaire shall be with smart self-diagnosis feature with LED indicators alongwith battery charging and deep discharging out off indications. The system shall use long time maintenance free lithium Ferro Phosphate (Li Fe PO 4) battery with BIS certification. Battery capacity of minimum 170 wh for autonomy of 24 hrs with fully charged battery. The luminaire shall be with hybrid feature (integrated/ seperated) ON-OFF switch, Outer mounting diameter of 48-60 mm. Operating temp range for light engine is 0 to +35 Dep C. operating humidity shall be upto 95%. System lumen output should be atleast 12V DC, 2000 lm. Solar panel module capacity of 12V, 35W Peak Mono-crystalline. Solar cell efficiency with min 12%. LED burning hrs to be 50,000 hrs at L70. Rating of IP 65 and IK 08 to comply with UV stabilized poly carbonate front cover. Colour temp of 5700K and CRI > 70 including taking down existing one all as directed. Make : Philips Cat No BRP 710 LED 30 CW MR HY FDIM 50 Solar or equivalent in Wipro/ Bajaj. Note :- The unit rate is deemed to included for 6 mtr long MS/GI pipe of 50MM bore medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engr-in-Charge
Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report including BIS certification. (b) The contractor shall submit warranty certificate from manufacturer for minimum 5 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall also submit safety and performance standard compliance of IEC 60598-2-3 for road and street lights, IEC 62109-1 for power converters used in Solar Panel, EN 50530 for MPPT performance evaluation, IEC 61607 for EMC immunity, CISPR 15 for Radio disturbance characteristics, IEC 62133, IEC 61960 and UL 1642 for safety of lithium Ferro Phosphate battery and IEC 61730-1, 2 & IEC 61215 for safety of solar panel module. (e) The rates quoted deemed to be included 6 mtr long MS/ GI pipe of 50mm bore medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engineer-in-Charge.
S&F in replacement on distribution board MCCB four pole, 125 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified. Make : Siemens/ L&T/ ABB
S&F in replacement factory made powder coated distribution board VTPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens or equivalent of Schnieder & ABB
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep in depth in hard/ dense soil and getting out
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point. Note :- In case insufficient qty for filling as sand cushion to cable not obtained from execution and if extra sand is reqd the same shall be brought from out side MD land without extra cost from the department.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
Supply and lay fly ash cable protection cover of size 23x11.5 x7.5cm including taking down existing bricks of any size.
Supply & Laying XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Supply & Laying XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 sq mm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Cutting existing road/PCC/Drain for laying of DI/GI or any typeof pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.
Note :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type C1 as in any type of road
Supply only GI pipe 50 mm bore medium grade for cable protection complete all as specified and as dierced by Engr-in-Charge. Make : Tata, Jindal, Surya Prakash Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately.
Electronic energy meter 3 Phase 30 to 60Amps range capacity. Make : BENTEC / L&T/ABB Note :- Old unserviceable meter deposit to E/M store yard.
S&F LED retrofit lamp 15W, warm white, (lumen output not less than 1350 lumens) with B-22 holder base with thermal conductive engineering plastic white colour housing and aluminium heat sink with specially designed fins clear /cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation all as specefied and directed. Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2. The contractor shall submit warranty certificate from manufacturer for minimum 2 years Make : Wipro cat part No. LL20-111-XXX-65NE3 or equivalent of Philips/ Bajaj
All as per item No 159 above but LED retrofit lamp 12W
S&F recess mounting powder coated luminaire white CRCA full glow LED ceiling lights indoor 2'x2' not less than 36watt, colour temperature white complete all as specified and directed. Make : Philips Cat No RC365BLED33-6500 PSU OD WH or Wipro/ Bajaj Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
S&F small thread LED candle bulb 05 watt, warm white E-14, 2700K as per sample complete all as specified and directed. Make : Philips/ Wipro/ Bajaj Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
S&F wall lamp with LED 12 W wall lamp indoor type including accessories all as specified and directed by Engr-in-Charge. Make /Model : LUKER cat part No. LWL105/ Philips/ Wipro
S&F wall light fitting with surface & wall mounted LED light suitable fittings star's sleek, polished lamps are fully rotatable to any angle instanly add striking accents to your room with its bright focused light. Make,Philips Cat No.56240/31/86 or equivalent in CG and Wipro.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC existing steel conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 4 runs of 4 sqmm cable along with two run of 4 sqmm cable for earth conductor shall be measured as one length including taking down UNSV old wiring. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F in replacement factory made powder coated distribution board SP & N 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens or equivalent of Schnieder & ABB
S&F in replacement on distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified. Make : Siemens/ L&T/ ABB
Supply and fixing road lighting luminaire of watt 20 watt LED 2000 lumens street light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and taking down UNSV street light fittings all as specified and directed, Make : Philips Cat No BRP022 LED 20 CW MR S1 PSU GR or equivalent in Wipro/Syska. Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Supply and Fixing of 4 feet surface mounted battern type luminaire with a power consumption not more than 16 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 120 lm/W with an operanting voltage range from 140V-270V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than. The luminaire shall have a CCT of 6500 K, CRI>80, power factor>0.95, SDCM<5, THD<10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC complaint and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability (The driver can be replaced at site level). The luminaire shall not weight more than 7 Kg and the luminaire and driver shall be BIS approved with "R" number mentioned. Make : BN308 LED20S 6500 L120 PSU WH or equivalent in LT or schreder.
Note for item No 170 :- (a) LED Chip make shall be Nichia, Osram, Cree, Lumilid. (b) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
M&L for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC casing caping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lups) only.
One light point/fan/bell point controlled by one switch
All as per item No. 172 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 172 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 172 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC Conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Supreme/ Diplast/ Avon Plast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lups) only.
One light point/fan/bell point controlled by one switch
All as per item No. 177 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 177 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 177 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and Fix switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Supply and Fix switch piano flush type 15 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Supply and Fix shuttered socket outlet 3 pin 5 amps, flush type
Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and15 amps
Supply and Fix modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
S& F replacement of convetional type post top fitting with LED Post tops lamp fitting 1x45 W LED made die cast aluminium with innovative glare free indirect lighting ditribution & IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed.Make/cat part No. CG cat no. LPTO-40/CDL/Bajaj Cat Part No. BRIL 45 W LED NW /philips.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 4 runs of 6 sqmm cable along with two run of 6 sqmm cable for earth conductor shall be measured as one length including taking down UNSV old wiring. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Supply & Laying XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 35 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Supply & Laying XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 50 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Supply and fixing power contactor 40 amp for lighting control including taking down old u/s contactor swiches complete all as directed.make:- legrand cat part No.412544 or Schnieder/ Siemens
Supply and fixing road lighting luminaire of 36 watt LED street light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and taking down UNSV street light fittings all as specified and directed, Make : Philips Cat No BRP 409 LED CW 036 MR FG S1 PSU GR/Wipro/Syska . Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Supply only big thread LED candle bulb 05 watt, warm white E-27, 2700K as per sample complete all as specified and directed. Make : Philips/ Wipro/ Bajaj Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Electronic energy meter single Phase 5 to 30Amps range capacity. Make : BENTEC / L&T/ABB Note :- Old unserviceable meter deposit to E/M store yard.
Supply & Laying XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 6 sq mm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC existing steel conduit and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F LED retrofit lamp 9W, warm white, (lumen output not less than 1350 lumens) with B-22 holder base with thermal conductive engineering plastic white colour housing and aluminium heat sink with specially designed fins clear /cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation all as specefied and directed. Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2. The contractor shall submit warranty certificate from manufacturer for minimum 2 years Make : Wipro cat part No. LL20-111-XXX-65NE3 or equivalent of Philips/ Bajaj
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt Magnesium Sulphate (1 : 1: 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Note :- (a) All Joints should be joined by Exothermic Welding or Brazing. (b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. (c) Earth resistance tester will be provided by the contractor. It should be caliberated from authorised company/ lab. (d) After testing if desired earth vesistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
eurekaenterprises
NAVEEN ENTERPRISES
LAKSHMI ELECTRICAL ENTERPRISES
pk janardhanan
KSR AND COMPANY
Neptune Engineers and Builders
Lucky Enterprises
D.R ASSOCIATES
p.chinnasamy
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .