Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 CrAccepted-AOC | ₹5.8 Cr Quoted ₹5.9 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹6.2 Cr+₹34.8 L (5.91%)Rejected-Finance 519 1A UPPER GROUND FLOOR MAIN ROAD VISHWAS NAGAR SHAHDARA DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | ₹6.2 Cr+₹34.8 L (5.91%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹6.9 Cr+₹96.8 L (16.4%)Rejected-Finance | ₹6.9 Cr+₹96.8 L (16.4%) | L3 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹14.6 L
Closing Date
26 Oct 2023, 11:00 amClosed
Parveen Kumar
Division - Sewerage
Rehabilitation of existing deteriorated/damaged Master Sewer line with (Cured-In-Place Pipe) CIPP Technology for size 450mm, 600mm, 700mm and 800mm i/d
2023_HRY_314934_1
202307C76A0D 9F1A 4A5D BC04 A4F8032115FC717001
Open Tender
Civil Works
Works
180 days
Gurugram
2 documents required · 2 mandatory
₹1,000
₹14.6 L
Yes
15 Feb 2024
25 Sept 2023
26 Oct 2023
25 Sept 2023
26 Oct 2023
25 Sept 2023
Amount
Providing CCTV survey by Pan Tilt Camera with zooming and rotating 360 degree of pipe line after desilting and proper cleaning of existing sewer line for inspection and designing the thickness of required CIPP lining according to the deteriorated condition of pipe line and submit the soft / hard copy of the result showing the location and date of survey complete in all respect to the entire satisfaction of Engineer -In -Charge.
Providing CCTV survey by Pan Tilt Camera with zooming and rotating 360 degree of pipe line after CIPP lining process for inspection of the linining complete in all respect and submit the soft / hard copy of the result showing the location and date of survey complete in all respect to the entire satisfaction of Engineer -In -Charge.
Desilting of existing sewer lines with mechanical device i.e. super sucker machine of 270 HP to 400 HP engine driven and installing the plugging in manholes for temporary diversion and taking out rubbish debris, silt etc. All internal debris be removed from the existing sewer line and cleaned with high velocity jet cleaners of 200 PSI pressure according to NASSCO recommended specifications and disposal of the malba/ debris at site as directed by the Engineering -In - Charge. Traffic control arrangements and proper lighting at night, barricading, display of sign boards, Removal of all hindrances/ obstructions unforeseen items all to the satisfaction of Engineer - In - Charge of the work. 450mm i/d pipe line (60% silted)
Desilting of existing sewer lines with mechanical device i.e. super sucker machine of 270 HP to 400 HP engine driven and installing the plugging in manholes for temporary diversion and taking out rubbish debris, silt etc. All internal debris be removed from the existing sewer line and cleaned with high velocity jet cleaners of 200 PSI pressure according to NASSCO recommended specifications and disposal of the malba/ debris at site as directed by the Engineering -In - Charge. Traffic control arrangements and proper lighting at night, barricading, display of sign boards, Removal of all hindrances/ obstructions unforeseen items all to the satisfaction of Engineer - In - Charge of the work. 600mm i/d pipe line (60% silted)
Desilting of existing sewer lines with mechanical device i.e. super sucker machine of 270 HP to 400 HP engine driven and installing the plugging in manholes for temporary diversion and taking out rubbish debris, silt etc. All internal debris be removed from the existing sewer line and cleaned with high velocity jet cleaners of 200 PSI pressure according to NASSCO recommended specifications and disposal of the malba/ debris at site as directed by the Engineering -In - Charge. Traffic control arrangements and proper lighting at night, barricading, display of sign boards, Removal of all hindrances/ obstructions unforeseen items all to the satisfaction of Engineer - In - Charge of the work. 700mm - 800mm i/d pipe line (60% silted)
Providing and installing of Cured -in - Placed - Pipe liner (CIPP Liner) existing sewer pipe line and the design vetted from IIT Delhi / NIIT Kurukshetra / WRC London based on the report of CCTV regarding the deteriorated condition of existing sewer line. The temporary diversion should be provided through the required submersible pumps and Gen set etc. with including the laying rising main from upstream side of working length for smooth flow/bye pass of sewerage system to avoid the flooding in adjoining area. The CIPP liner should be made with Felt (Tube) of make Insituform/Applied Felt/Roders of required size and Resin of make Scottbadder /AOC / Raycold and other specified chemical and material including the machinery and equipments such as Leaflet Hose, Conveyor System, Diesel Operated Water Boiler with injection and suction pumps, Inversion Tower, Hydra, JCB, Support Vehicle, Gen Set of 62 KVA, Air Compressor, Vacuum Machine, Pneumatic Mechanical Mixer with ice buckets, Water Tanker, THF and PU Sheet, Submersible pump, and other safety equipments required at site and skilled / fully trained labour / staff as required for the process of CIPP lining. The CIPP lining should be in proper gradient / slope and including the testing of line after CIPP lining complete in all respect to the entire satisfaction of Engineer -In - Charge.450mm i/d pipe line (minimum thickness 10mm or as per design whichever is on higher side vetted from IIT Delhi /NIIT Kurukshetra / WRC London)
Providing and installing of Cured -in - Placed - Pipe liner (CIPP Liner) existing sewer pipe line and the design vetted from IIT Delhi / NIIT Kurukshetra / WRC London based on the report of CCTV regarding the deteriorated condition of existing sewer line. The temporary diversion should be provided through the required submersible pumps and Gen set etc. with including the laying rising main from upstream side of working length for smooth flow/bye pass of sewerage system to avoid the flooding in adjoining area. The CIPP liner should be made with Felt (Tube) of make Insituform/Applied Felt/Roders of required size and Resin of make Scottbadder /AOC / Raycold and other specified chemical and material including the machinery and equipments such as Leaflet Hose, Conveyor System, Diesel Operated Water Boiler with injection and suction pumps, Inversion Tower, Hydra, JCB, Support Vehicle, Gen Set of 62 KVA, Air Compressor, Vacuum Machine, Pneumatic Mechanical Mixer with ice buckets, Water Tanker, THF and PU Sheet, Submersible pump, and other safety equipments required at site and skilled / fully trained labour / staff as required for the process of CIPP lining. The CIPP lining should be in proper gradient / slope and including the testing of line after CIPP lining complete in all respect to the entire satisfaction of Engineer -In - Charge.600mm i/d pipe line (minimum thickness 15mm or as per design whichever is on higher side vetted from IIT Delhi /NIIT Kurukshetra / WRC London)
Providing and installing of Cured -in - Placed - Pipe liner (CIPP Liner) existing sewer pipe line and the design vetted from IIT Delhi / NIIT Kurukshetra / WRC London based on the report of CCTV regarding the deteriorated condition of existing sewer line. The temporary diversion should be provided through the required submersible pumps and Gen set etc. with including the laying rising main from upstream side of working length for smooth flow/bye pass of sewerage system to avoid the flooding in adjoining area. The CIPP liner should be made with Felt (Tube) of make Insituform/Applied Felt/Roders of required size and Resin of make Scottbadder /AOC / Raycold and other specified chemical and material including the machinery and equipments such as Leaflet Hose, Conveyor System, Diesel Operated Water Boiler with injection and suction pumps, Inversion Tower, Hydra, JCB, Support Vehicle, Gen Set of 62 KVA, Air Compressor, Vacuum Machine, Pneumatic Mechanical Mixer with ice buckets, Water Tanker, THF and PU Sheet, Submersible pump, and other safety equipments required at site and skilled / fully trained labour / staff as required for the process of CIPP lining. The CIPP lining should be in proper gradient / slope and including the testing of line after CIPP lining complete in all respect to the entire satisfaction of Engineer -In - Charge. 700mm i/d pipe line (minimum thickness 16mm or as per design whichever is on higher side vetted from IIT Delhi /NIIT Kurukshetra / WRC London)
Bidder Name
Amount
Onsite India Private Limited (GSTN-07AAACO9518J1Z6) BID ID -960640
Insituform Pipeline Rehabilitation Pvt Ltd(GSTN-NA)--961031
suryacon engineers(GSTN-NA)--961029
suryacon engineers
Insituform Pipeline Rehabilitation Pvt Ltd
suryacon engineers
Insituform Pipeline Rehabilitation Pvt Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .