| 1 | L1₹39.4 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.0 L+₹2.8 L (7.05%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹47.1 L+₹7.0 L (17.3%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹60.1 L+₹20.0 L (49.8%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹64.3 L+₹24.2 L (60.2%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
22 Feb 2023, 6:00 pmClosed
GE (UTILITY) UDHAMPUR
GE (UTILITY) UDHAMPUR, PO-GARHI, PIN-182121
Repair/Maint to earthing system, feeder pillar boxes, LT UG cables and connected accessories at various location of AGE Electric under GE (Utilities) Udhampur.
2023_MES_577179_1
GE/U-70/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (UTILITY) UDHAMPUR
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (UTILITY) UDHAMPUR
₹90,000
Yes
28 Mar 2023
25 Jan 2023
24 Feb 2023
25 Jan 2023
22 Feb 2023
8 Feb 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundations of poles/stays etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge.
Supply,Laying and fixing in replacement of along the poles or passing through pipes or laid under floor of through walls etc jointing and testing LT Cross Linked Polythene Insulated(XLPE insulated) galvanized steel strip armoured electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor and overall served with an outer sheath of PVC, of cross sectional area including suitable cable lux and taking down as under:- Note : Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately.
25 sqmm 4 core.
150 sqmm 3.5 core.
240 sqmm 3.5 core.
Supply, Laying and fixing in replacement of along the poles or passing through pipes or laid under floor of through walls etc jointing and testing LT Cross Linked Polythene Insulated(XLPE insulated) galvanized steel strip armoured electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor and overall served with an outer sheath of PVC, of cross sectional area including taking down as under:- Note : Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately.
185 sqmm single core.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15 mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) ON Load Change over switch 400 amp fixed type manual jod 4 pole, 50Hz ,415 V with rupturing capacity 35/36 KA-01 No. Make :- L&T, Legrand, Schneider, Havells, ABB,C&S. (b) Bus bar electrolytic grade copper 600 Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set.
Outgoing:- (a) MCCB 400 amps, 4 pole, 35/36 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 01 Nos. Make :- L&T, Legrand, Schneider, Havells, ABB,C&S. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using suiotable gun metal /SS glands.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15 mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) MCCB 400 amp fixed type manual jod 4 pole, 50Hz ,415 V with rupturing capacity 35/36 KA-01 No, Make :- L&T, Legrand, Schneider, Havells, ABB,C&S. (b) Bus bar electrolytic grade Aluminium 600 Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set.
Outgoing:- (a) MCCB 200 amps, 4 pole, 35/36 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 02 Nos. Make :- L&T, Legrand, Schneider, Havells, ABB,C&S. (b) MCCB 100 amps, 4 pole, 25/26 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 02 Nos. Make :- L&T, Legrand, Schneider, Havells, ABB,C&S. Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using suiotable gun metal /SS glands.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15 mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) MCCB 300/320 amp fixed type manual jod 4 pole, 50Hz ,415 V with rupturing capacity 35/36 KA-01 No, Make :- L&T, Legrand, Schneider, Havells, ABB,C&S. (b) Bus bar electrolytic grade Aluminium 600 Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set.
Outgoing:- (a) MCCB 160 amps, 4 pole, 35/36 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 02 Nos. Make :- L&T, Legrand, Schneider, Havells, ABB,C&S (b) MCCB 100 amps, 4 pole, 25/26 KA , with adjustable thermal over load release 50 Hz, 415 volts grade - 02 Nos. Make :- L&T, Legrand, Schneider, Havells, ABB,C&S. Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using suiotable gun metal /SS glands.
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15 mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming:- (a) On load change over switches 4 pole of capacity 200 Amps -01 Nos. Outgoing:- (a) Copper bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 300 amps for phases and neutral - 01 set. Note:- Provision has to be made during fabrication for utilisation of change over supply both ends which ever required.
Supply & fix LT panel out door (Kiosk type) type, weather & vermin proof MS sheet housing 3.15 mm thick, powder coated over a coat of primer, double door, front & rear openable type, mounted on 40x40x6 mm angle iron frame, floor mounted type with one MCCB, 4 pole, 100 Amp, 25 KA 415 volts as incomer, copper bus bar 200 Amp of length not less than 60 cm, 4 pole duly drilled with holes for cable connections, after due approval of panel drawing including PCC pedestals of suitable size, Including taking down complete all as specified and directed by Engr-in-Charge.
S&F AMP Contactor GMC-400 4 polos current /corriente continua 100-200 v 50/60 HZ complete all as required at site, including taking down complete all as specified and directed by Engr-in-Charge.
S&F new MCCB 400 amp, -50 kA with adjustable thermal and fixed magnetic setting suitable frame size, 4 Pole,Ics=100%Icu- 415 V, 50 Hz, 3 phase including extension terminals (Spadels) and connecting using suitable fasteners, modification/fabrication if any complete all as required at site, including taking down complete all as specified and directed by Engr-in-Charge.
All as per serial item No 12.00 here-in-before but of capacity 315/320 amp, -35/36 kA.
All as per serial item No 12.00 here-in-before but of capacity 160amp, -35/36 kA.
All as per serial item No 12.00 here-in-before but of capacity 100mp, -25/26 kA.
M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25 x 4 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- All the joints shall be made with welding to get proper conductivity.Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost complete all as specified and directed by Engr-in-Charge.
M&L for Boring / Road cutting for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified by Engr-in-Charge.
S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge.
S&F double walled corrugated (DWC) pipe of size 50 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as complete all as specified and directed by Engr-in-Charge.
Material and labour in replacement of PVC insulated multi stranded aluminum conductor PVC cable sheathed10 Sqmm twin core and making connections of street light fittings with overhead lines/UG Cable complete all as specified and directed. Make: Plaza/ Paragon/ Kalinga.
FANGALIA TRADERS
MOHAN LAL AND SONS
PREM NATH KHAJURIA AND SONS
PROACH ASSOCIATES BUILDERS & ENGINEERS
K S BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .