| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC | ₹29.3 L Quoted ₹29.9 L | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹30.0 L+₹11,028.90 (0.37%)Rejected-Finance NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | ₹30.0 L+₹11,028.90 (0.37%) | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹30.6 L+₹63,859.40 (2.13%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹30.6 L+₹63,859.40 (2.13%) | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 4 | L4₹31.7 L+₹1.7 L (5.76%)Rejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹31.7 L+₹1.7 L (5.76%) | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 5 | L5₹32.9 L+₹3.0 L (10.0%)Rejected-Finance | ₹32.9 L+₹3.0 L (10.0%) | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
6 Jul 2023, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
8782REPAIR MAINT TO LT DISTRIBUTION SYSTEM LT PANELS FEEDER PILLAR BOX AND ASSC ITEMS AT TECH AREA OF EAST AREA OF AFS JALAHALLI UNDER GE M AF JALAHALLI BANGALORE
2023_MES_601729_1
8782/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT JALAHALLI PUBLIC FUND ACCOUNT
₹72,000
18 Aug 2023
7 Jun 2023
8 Jul 2023
7 Jun 2023
6 Jul 2023
23 Jun 2023
7 Jun 2023 - 14 Jun 2023
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level complete all as specified and directed by Engr-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed by Engr-in-charge.
Removing surplus exacavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed by Engr-in-charge.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness only will be considered for payment.
Material and labour for well burnt as class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as specified and directed by Engr-in-charge.
Supply & Erecting in replacement of Mild steel tubular swaged poles of 9.0 meter long 410, SP-31 complete with cast iron base plate, bracket, final taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of red oxide primer and painting with black up to 1.5 meter from top of PCC coping white colour paint as in strips of equal width including marking pole numbers with one coat of synthetic enamel paint complete all as specified and as directed.
Dismantling of U/S steel tubular swaged poles of 9 mtrs height including setting aside and transporting to stores as directed.(Excavation and earth will be measured and paid separately).
Supply and fixing galvanized tubes light grade with fixing wall/floor with clamp, nut bolt, washers/ saddling for cable protection pipe of 80 mm bore including taking down existing GI pipe.
Supply and fixing galvanized tube light grade with fixing wall/floor with clamp, nut bolt, washers/ saddling for cable protection pipe of 50 mm bore including taking down existing GI pipe.
Supply and fixing galvanized tube light grade with fixing wall/floor with clamp, nut bolt, washers/ saddlings for cable protection pipe of 40 mm bore including taking down existing GI pipe.
Material and Labour for cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts,washersetc. Including welding /bending in cold or hot , drilling holes for bolts , in any shape or size as indicated as directed .
Dismantling the rusted out cross arms , bracings ,s supports and back plates from the pole all as specified.
Material and Labour for Pin type porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 100 mm height 65mm dia for 1100 volts grade all as specified .
Material and Labour for shackle type insulators porcelain vitreous white brown of green including GI mild straps 31x3mm 75mm height, 90mm dia at working pressure 1100 volts as as directed .
Dismantling of US LT insulators of any type.
Material and labour for stay assembly comple with accessories as shown in electrical plate No. 1 with 16 mm dia rod and loop type insulator stay clamps ettc as specified and directed (Excavation and concrete will be measured and paid separately.)
Material and Labour for loop type porcelain vitreous white brown or green insulator with overall dimensions 65mmx 90 mm clearance of hole 16 mm including taking down old US insulators .
Material and Labour for fixing GI stay strand of size 7/3.15 mm
Dismantling the US stay assembly complete including stay strand.
Material and Labour for plain cement concrete type D2 1:4:8 using 40mm graded stone aggregate for foundation of poles etc, all as specified
Material and Labour for plain cement concrete type C2 1:3:6 using 40mm graded stone aggregate for foundation of stay etc all as specified and as directed.
Material and Labour for plain cement concrete type C1 1:3:6 using 20mm graded stone aggregate for coping for poles including necessary form work to exposed surfaces finished smooth and even all as specified.
Taking down old out lived / fully oxidised ACSR conductor 4 wire / 2wire from existing LT poles after disconnecting necessary jumpers insulators etc all as directed and offering credit.
Material and Labour for ACSR conductor of any size for LT over head lines and jumpers .
Material and labour for GI wire 4mm dia fixed to LT pole all as directed for earth continuity .
Taking down the old US fully rusted out GI wire from the pole.
Material and Labour for ACB 3 phase 415 Volts 4 pole with Thermal Magnetic Release (Manual Fixed Type) of Capacity 630 Amps including necessary modification to accommodate the ACB wherever required and taking down existing old ACB.
Material and Labour for MCCB 3 phase 415 Volts 4 pole with neutral link 63 Amps 16 KA including necessary modification to accommodate the MCCB wherever required .
AlI as per item No. 28 herein before but of rating 100 Amps of 16 KA
AlI as per item No. 28 herein before but of rating 125 Amps of 16 KA
AlI as per item No. 28 herein before but of rating 160 Amps of 25 KA
AlI as per item No. 28 herein before but of rating 200 Amps of 25 KA
AlI as per item No. 28 herein before but of rating 250 Amps of 25KA
AlI as per item No. 28 herein before but of rating 315 Amps of 36 KA
AlI as per item No. 28 herein before but of rating 400 Amps of 36 KA
AlI as per item No. 28 herein before but of rating 630 Amps of 50 KA
Material and Labour for MCCB 3 phase 415 Volts 3 pole with neutral link 63 Amps 16 KA including necessary modification to accommodate the MCCB wherever required .
AlI as per item No. 37 herein before but of rating 100 Amps of 16 KA
AlI as per item No. 37 herein before but of rating 125 Amps of 16 KA
AlI as per item No. 37 herein before but of rating 160 Amps of 25 KA
AlI as per item No. 37 herein before but of rating 200 Amps of 25 KA
AlI as per item No. 37 herein before but of rating 250 Amps of 25KA
AlI as per item No. 37 herein before but of rating 315 Amps of 36 KA
Material and labour for 3 ½ core 240 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed
AlI as per item No. 44 herein before but 3 ½ core 185 Sqmm
AlI as per item No. 44 herein before but 3 ½ core 150 Sqmm
AlI as per item No. 44 herein before but 3 ½ core 120 Sqmm
AlI as per item No. 44 herein before but 3 ½ core 95 sqmm
AlI as per item No. 44 herein before but 3 ½ core 70 sqmm
AlI as per item No. 44 herein before but 3 ½ core 50 Sqmm
AlI as per item No. 44 herein before but 3 ½ core 35 Sqmm
AlI as per item No. 44 herein before but 3 ½ core 25 Sqmm
AlI as per item No. 44 herein before but 4 core 16 Sqmm
AlI as per item No. 44 herein before but 2 core 16 sqmm
AlI as per item No. 44 herein before but 2 core 10 sqmm
AlI as per item No. 44 herein before but 2 core 6 sqmm
Material and Labour for restringing of LT lines with permissible sag including properly binding with insulators by providing new ACSR conductors of existing size for the 4 wire only (3 Phase and neutral) Note:- 4 wire will be measured as one length.
Material and Labour for restringing of LT lines with permissible sag including properly binding with insulators by providing new ACSR conductors of existing size for the 2 wire only (single Phase and neutral) Note:- 2wire will be measured as one length.
Material and Labour for two coats of synthetic enamel painting of old LT PCC / RCC/ PSC poles at the bottom from ground level towards upwards up to 2 m height with black and yellow strips each 15 cm width on the poles Including marking of pole numbers using white synthetic enamel paint over black colour base .
Material and Labour for painting of old LT steel tubular pole 9m long after preparation of surface including cross arms ,bracings, supports & clamps for stay/security light fittings etc, with one coat of aluminum paint all as directed and specified .
Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanised earth strip of size 25X4 mm (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, checknuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs complete all as speified and directed by Engr-in-charge.
Supply and fix PVC spacers 2 way for LT OH line 1100 volts grade with necessary screws nuts bolts etc complete all as directed to prevent the lines touching each other on heavy wind as as a preventive arrangement to the existing system.
Supply and fix PVC spacers 4 way for LT OH line 1100 volts grade with necessary screws nuts bolts etc complete all as directed to prevent the lines touching each other on heavy wind as as a preventive arrangement to the existing system.
Taking out the existing spacers from the LT OH line carefully by removing the screws for carrying out the restringing work carefully by means of suitable ladders all as directed for PVC spacers 2 way and 4 way.
Dismantling the LT UG cable of size 10 to 35 sqmm 3.5core 4 wire from existing Main switch and cutting out the burnt out portion and reconnecting to the switch after removing and readjusting the cable including necessary earth work and excavation asper site requirement including new cable lugs fixing all as directed and specified .
All as per item No.65 here in before but cable of size 3 1/2 core 50 sqmm to 95 sqmm
All as per item No.65 here in before but cable of size 3 1/2 core 120 sqmm to 240 sqmm
All as per item No.65 here in before but cable of size 3 1/2 core 300 sqmm / 400 sqmm
Supply & Fix Aluminum lugs suitable for UG cable of size 3 1/2 / 4 core 16 to 35 sqmm including respective size of lugs for the neutral cable.
All as per item No.69 here in before but UG cable of size 3 1/2 core 50 sqmm to 95 sqmm
All as per item No. 69 here in before but UG cable of size 3 1/2 core 120 sqmm to 240 sqmm
All as per item No. 69 here in before but UG cable of size 3 1/2 core 300 sqmm to 400 sqmm
Material and labour for cutting tree branches below, top and around the LT OH line and clearing not less than two mtrs around the line and keeping the line clearance through out the contract period by trimming the branches repeatedly as many as times required depending on site requirement complete all as specified and directed by Engr-In-Charge.
Material and Labour for making straight through joint with suitable jointing kit consisting water proof adhesives for UG cable of size 3 1/2 / 4 core 25 to 35 sqmm.
All as per item No.74 here in before but for UG cable of size 3 1/2 core 50 sqmm to 95 sqmm
All as per item No.74 but for UG cable of size 3 1/2 core 120 sqmm to 150 sqmm
All as per item No.74 but for UG cable of size 3 1/2 core 185 sqmm to 300 sqmm
Servicing the LT voltage stabilizer including dehydration of transformer oil including replacement of warn out of LT bushes including testing and commissioning all as specified and directed by Engr-In-Charge.
Supply and topping up or replacement of Voltage stabilizer oil with di-electric strength not less than 50 KVA of the voltage stabilizer etc at various locations complete all as specified and as directed. Make: Power oil/ Transol/ Sabitha Chemicals
Surface dressing in hard / dense soil not exceeding 15 cm deep and clearing all the inside area in the sub station yards after removing grass all as specified directed at site. Note:- (ii) The rate also deemed to be included for labour (iii) All the sub station yards shall be kept clean through out the contract period by removing the grass/weeds as many as times required depending on the growth of the grass.
Material and Labour for Servicing to LT panels/Feeder pillar boxes/APFC Panels comprising MCCBs/switch disconnector fuses/change over switches metering eqpt etc. as incoming/outgoing controls including cleaning, checking the serviceability of individual items, identification of the defective parts replacing the worn-out fasteners, insulators, rubber door beadings, gaskets etc. complete all as specified and directed. Note :- Unserviceable parts replaced shall be measured & paid separately under relevant item
Material and Labour for cable roue indicator made out of CI plate 100 dia,6mm thick and fixed over angle iron of size 30X60X6 mm,120cm in length duly painted with alumiuium paint with aluminium paint suitable for LT cable all as specifed and including embeded in PCC (1:3:6) type C1 of size 30X30X20cm in ground complete all as specified and directed.
Material and labour for painting with one coat of synthetic enamel paint on steel surface including preparation of old surface complete as specified and directed by Engineer- in- charge.
ARUNOTHAYA TRADERS
M/S SRI BALAJI ENTERPRISES
NAVREET CONSTRUCTION
RAMESH BABU CO
Shanthi Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .