Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC | L1 | Accepted-AOC QUALIFIED | |
| 2 | L2₹25.9 L+₹1.9 L (8.06%)Rejected-Finance | L2 | Rejected-Finance TENDER IS HIGHEST RATE | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹24.5 L
EMD Value
₹49,080
Closing Date
25 Mar 2022, 5:00 pmClosed
PROJECT ENGINEER
1558 RISHI COTTAGE RATAN COLONY JABALPUR
EXTERNAL ELECTRIFICATION WORK FOR 112 QTR HIGH RISE CIVIL LINE JABALPUR
2022_MPPHC_190208_1
21/2021-22
Open Tender
Entertainment/Musical Instruments
Item Rate
90 days
JABALPUR
AS PER NIT
5 documents required · 5 mandatory
₹5,000
₹49,080
7 Jun 2022
12 Mar 2022
28 Mar 2022
12 Mar 2022
25 Mar 2022
12 Mar 2022
Amount
Supplying and erection single length support for 33KV/11KV line complete with aligning and keeping it in truly vertical position, including digging pit of required size in all type of soil/rocks, filling with 1:3:6 cement concrete of0.50 mtr. dia. around the pole up to ground level includingmuffing of 0.45 mtr. dia. from ground level to 0.45 mtr. high as per specifications with 20 cm. thick base foundation in1:4:8 cement concrete as required, refilling the pit withboulder and soil as required, including painting of pole withbitumen paint below GL and two coats of red oxide and two coats of aluminium paint or synthetic enamel paintas directed etc as per specification complete The depth of burying of pole shall be 1/6th of the length of pole.H beam 152x152mm or 150x150mm 37.1 Kg./M. weight H Beam 13 Mtr Long 152x152 or 150x150 mm 37.1 Kg/Mtr. Weight
STAY SET :Supplying and erection of GI/MS stay set complete with stay rod, anchor plate of size 300x300x5mm, thimble,stay rod, anchor plate of size 300x300x5mm, thimble,stay clamp, turn buckle, bow tightener etc. with stay wire, strain insulator, nut bolts as per specifications including excavation in all type of soil / rocks and foundation in cement concrete 1:3:6 of required size and other necessary materials complete as required as per specifications. GI Stay Rod 20mm dia 1.8 m long with 7/4mm stay wire for HT line
AAAC CONDUCTOR:-Supplying and drawing AAAC conductor of approved make with stringing making off complete with binding at existing insulator, jointing, jumpering, teeing off connecting etc. as required and clearing of obstacles (if any). (A) AAAC Conductor 55 sqmm aluminum or Equivalent (Rabbit) (0.05sqinch)
AAAC CONDUCTOR:-Supplying and drawing AAAC conductor of approved make with stringing making off complete with binding at existing insulator, jointing, jumpering, teeing off connecting etc. as required and clearing of obstacles (if any). (B) AAAC Conductor 100 sqmm aluminum or Equivalent (Dog) (0.10 sqinch)
Providing and fixing outdoor type pole mounting weather, dust and vermin proof LT distribution box made of 14 gauge MS sheet with clamping arrangements, lockable hinged door duly painted on all sides with red oxide after antirust and corrosion treatment, two coats of synthetic enamel paints of approved make and shade, consisting of following fittings: For 100 KVA Transformer(a) 200 Amps 35 KA breaking capacity TP MCCB with neutral link for incoming - 1No. (b) 4 strip aluminium bus bar 400Amps supported on epoxy insulators - 1 Set (c) 160/200 Amps, 415Volts DMC cutout with base for outgoing feeder with 160/200 amp HRC - 9 Nos. (d) GI earth terminals- 2 Nos.(e) 6 Lever Godrej Padlock with 3 keys - 1 No. (f) Light point with switch and lamp holder with lamp - 1 No. Distribution box complete as above (a to F) as per MPKVVCL norms & specifications complete.
Supplying and erection of steel tubular pole swaged type as per IS:2713 1980 Complete with baseplate and top Canopy (with G.I. pipe bracket as required), supports complete with digging and keeping it in truly vertical position i/c digging pit of required size filling with 1:3:6 cement concrete of 0.60 meter dia. of required length around the pole i/c muffing of 0.45meter from ground level as per specification with 20cm.thick base foundation providing and busying 15mm.dia.G.I.pipe from bottom to 1.5meter above ground level on pole, refilling the pit i/c. painting of pole with bitumen paint in bottom and one coat of red oxide and two coat of aluminum paints etc. complete as per specification. The depth of foundation shall be1/6th of the length of pole. (A) 410 SP-29 - 9 meter long.
Supplying and fixing of Angle/ channel/flat iron, V cross Arms reinforcement of RSJ jolt/ flat iron fittings for overhead lines and poles such as cross arms/ bracket/ clamps/ stiffness for poles etc. all required steel work including' cutting to size making proper shapes drilling scan welding etc. including nuts & bolts plan & spring wisher and other necessary material including one coat of red oxide and two coat of aluminum paint etc. as required. Chequre plate/ Tenstion plate atc.
Supplying and fixing Polymer type 11 K.V. pin insulator with G.I. pin of approved make on existing pole or bracket with necessary materials and hardware complete as required.
Supplying and fixing polymer type 11 K.V. disc (strain) insulator of approved make on existing pole or bracket with necessary materials and hardware complete as required.
Providing and fixing earthing arrangement for H.T./L.T. poles with G.I. wire of 115 turn of 50mm dia. connection with bracket/ cross arm/ pole with 4mm dia. G.I. lead through 20 mm dia. G.!. Protection pipe of length from bottom of pole to 2 meter above ground level, packing of charcoal powder and salt as per specification including excavation of pit in all type of soil / rock etc. complete.
DANGER CAUTION PLATES :Providing and fixing enamelled danger caution plate/board on existing electric poles or wherever required of size 250x200 mm, made of 1.6mm thick mild steel sheet and vitreous enamelled white, with latest, figures and the conventional skull and cross-bones in signal red colour (as per IS-5-1978 with latest amendment) on the front side.The rear side of the plate shall also be enamelled. The corner of the plate shall be rounded off with required material such as screws, wires clamps, nut bolts etc. complete 33 KV/11 KV
Supplying and fixing 12x16 gauge barbed wire antidumping device (900 mm and3.5kg wire on pole) around the existing H.T. pole and sub station poles for safety measures as per IE rules including all staples and all other necessary materials complete as per mpseb specification.
Supplying, installing, connecting, testing and commissioning of approved make distribution transformer 5 star rating of accepted standard specification oil filled, core type aluminum wound out door type 11/ 0.4: KV step down with drain and filler . Value with locking arrangement two ear thing terminals, lifting arrangements and first filling of oil, conventional unit, including installation on existing D.P. structure. (A) 200KVA 11 / 0.433 KV (Conventional) BIS LEVEL III 5 Star Rated.
Supplying, installing, connecting, testing and commissioning of approved make distribution transformer 5 star rating of accepted standard specification oil filled, core type aluminum wound out door type 11/ 0.4: KV step down with drain and filler . Value with locking arrangement two ear thing terminals, lifting arrangements and first filling of oil, conventional unit, including installation on existing D.P. structure. (B) 100KVA 11 / 0.433 KV (Conventional) BIS LEVEL III 5 Star Rated.
Supplying ,laying ,testing, and commissioning of P V C insulated PVC heavy duty power cable confirming to lS 15541964 with upto date ammnandentment,1100 volt grade cable Of approved make in trench ,G I pipe Air (laying on pole) trench, i/c cost of excavation in any type of soil/rock etc. including connection through lugs by cramping method glands etc as required as per specification. For 200 KVA Transformer ( a) 315 Amps 35 KA breaking capacity TP MCCB with neutral link for incoming - 1No. (b) 4 strip aluminium bus bar 400Amps supported on epoxy insulators - 1 Set (c) 160/200 Amps, 415Volts DMC cutout with base for outgoing feeder with 160/200 amp HRC - 9 Nos. (d) GI earth terminals- 2 Nos. (e) 6 Lever Godrej Padlock with 3 keys - 1 No. (f) Light point with switch and lamp holder with lamp - 1 No. Distribution box complete as above (a to F) as per MPKVVCL norms & specifications complete.
Commissioning of D P structure over existing support with panting in an approved manner consisting of following (A) D. C. cross arm with clamp, nuts & bolts (100 x 50 mm only ) - 1 set (B) 11 KV D. O. fuse unit, lightings arrangement and AB swich mounting channel with nuts and bolts (75 x 40 mm channel) of require - 1 set (C) 11 KV Polymer AB swich as required - 1 set (D) Transformer mounting cross arms / channels with clamps nuts and bolts (100 x 50 mm channel ) - 1 set (E) 11KV Polymer Do fuse unit ( set of 3 no.) - 1 set (F) Transformer clamping set (50x50x6 mm angle ) with nuts and bolts etc. complete - 1 set (G) Transformer belting set (50x50x6 mm angle) with nuts and bolts etc. complete - 1 set (H) 11 kv polymer lightning arrestor ( 9 kv gapless type ( 5 kA ) for DTR ) ( set of 3 No.) - 1 set (I) supplying , fixing, testing and connecting of complete earling set of 7 No. as per MPMKVVC.Ltd. circular No DS CO M/EZ/ WS/1516/DT 17-03-2008 and approved dwring for transformer sub - station including all materials GI Strips, GI wires, Charcoal power salt excavation of pits in all types of soils/rocks etc. as required complete .( 1 set of 7 Nos.) -1 set (J) Distribution panel mounting channel and clamp with nuts & bolts etc. (75 x 40 mm channel ) 1 – set (K) Supplying , fixing, testing and Commissioning of DTR Meter LT. 3 phase 4 wire 3X240 volts I 3 A. LTCT operated 3 phase 4 wire 3x63, 5 volts , LB = 5 amps lmax 10 amp trivector meter glass of accuracy 0.5s DLMS complaint category a meter along with GSM ( GPRS compactable ) modems with box i/c all accessories and formalities as per MPMKVVCL as required. or 3P 4w - 5A LTCT class 5s DLMS compliant type c. rs - 232. Port box MRI LTCT 100/5A i/c meter box with TTB etc as required. (L) SF & T and HT tape for covering LT bushing i/c windings and blower hitting complete minimum 30 meter or as required. D.P. Structure Complete as above (A to L)
Supplying ,laying ,testing, and commissioning of P V C insulated PVC heavy duty power cable confirming to lS 15541964 with upto date ammnandentment,1100 volt grade cable Of approved make in trench ,G I pipe Air (laying on pole) trench, i/c cost of excavation in any type of soil/rock etc. including connection through lugs by cramping method glands etc as required as per specification. (A) Supplying laying testing and commissioning.UnArmoured single core XLPE insulated aluminum conductor cable. (a) 70 sq mm.
(A) Supplying laying testing and commissioning.UnArmoured single core XLPE insulated aluminum conductor cable. (b) 150 sq mm.
(A) Supplying laying testing and commissioning.UnArmoured single core XLPE insulated aluminum conductor cable. (b) 300 sq mm.
(B) Armoured 4 core XLPE insulated aluminum conductor cable. (A) 4 CORE 16 sqmm. (For street light)
(B) Armoured 4 core XLPE insulated aluminum conductor cable. (B) 2 CORE 10 sqmm. (For street light)
Supplying and drawing guard wire/earth wire/bearer wire 18.62 sq mm (4.87mm. dia/6swg) G.I. including stringing, binding at existing insulators or brackets,jointing, jumpering, connecting & cradle etc. as required and clearing of obstacles (if any 6 SWG (4.87 mm dia) guard wir
Supplying and erection of guards for existing overhead lines as required as per specification: 42.11.1 Cradle type
Supply & fixing fencing of chain link mesh100 x 100 mm, 12 SWG GI wire for forD.P. structure electric substationswitchyard including single post of angle ironsize50x50x5mm,2.5 mt long should beprovided upto 2.00 mt. apart or as required.The panel frame with required angle iron/flat iron members/cross members includingmesh welded inframe panel shall beerected between the posts. The angle ironpost shall be erected incementconcrete M-15 (1:2:4)(20mmgradedmetal)foundation,includingexcavation of pit andrefilling the same. The fencing shall beprovided with one entrance gate includinglocking arrangement as required as perspecification. The height of fencing shallbe 2 mt. above ground level. Fencing shallbe painted with required shade. Fencing of chainlink mesh 100x100mm, 12 SWG Giwire
Supply and fixing street light with high powerLED of 3 to 6 Watt each on existing bracketassembled on single MCPCB and additionalunique peanut lens on each LED, system lumensoutput with efficacy>120 lm/Watt. luminiarehaving color temp upto 6500K & 50000 hrs.burning life with minimum @ L 70,Thecolourrendering index of LED light should be morethan 70. Luminiare comprises of driver, PF>0.95 & surge protection 10KV. Housing made ofpressure die cast aluminium with heat resistantflat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/cconnection wire, testing etc. to complete the job.90Watt, color temp 3000-6500k as required. ( BAJAJ ,PHILIPS , HAVELLS, CROMPTION )
Supply and laying rigid PVC single socketand, non-metallic pipe ISI marked (IS-4985-2000) 10 Kg/sq.cm class 5 for protection ofunderground cable/or for water pumpdelivery side, for water supply completewith necessary clamp coupler, band, tee,elbow etc. in an approved manner excludingcost of excavation etc. Rigid PVC singlesocket and, nonmetallicpipe (A) 50.00mm O.D
Supplying and erection of water tightterminal box made of PCGFS(polycarbonate),IP 66 /IP 67 (cable entrysystems LES) in accordance withIEC60670-22, resistant to weather influences(UV due to solar radiation,protectedagainst rainwater, temperature resistant,impact resistant, etc. insulation voltage1000 V a.c./d.c., wall thickness of thebottom part 2 / 2.7 mm of required sizesuitable for kit kat/MCB/switch including 2nos. pole clamp of M.S. flat iron size32x3mm, nut and bolts, excluding the costof the kit kat/MCB/Switch, 4 Pole epoxyconnector nut & bolt type, 30Amp,500Volt complete as per specification asmentioned below.(MCB SP 6Amp to 32Amp 10kA rating ,Suitable for 6sqmm-16sq mm cable) Water tightterminal box(Polycarbonate 205 x 255 x 112 mm)
Supplying & installing G.I. pipe forprotection of underground cable fixed onwall/support/in trench/fixed between tworigid existing support of wall/beam forerection of ceiling Fan/down rod for stiffpendent for lightluminaries/fan/protectivefoearthing,lighteningconductordownstrip/overhead service line/for submersiblecable or centrifugal pump for water supplywith necessary iron clamp coupler, bend,tee, elbow, nuts and bolts etc. complete inan approved manner as required to completeexcluding cost of excavation/dismantling &other finished masonry Item complete.(For 'B' class pipe ISI marked (IS-1161-68)) (A)G.I. Pipe ‘B’ class 40 mm dia.
Supplying & installing G.I. pipe forprotection of underground cable fixed onwall/support/in trench/fixed between tworigid existing support of wall/beam forerection of ceiling Fan/down rod for stiffpendent for lightluminaries/fan/protectivefoearthing,lighteningconductordownstrip/overhead service line/for submersiblecable or centrifugal pump for water supplywith necessary iron clamp coupler, bend,tee, elbow, nuts and bolts etc. complete inan approved manner as required to completeexcluding cost of excavation/dismantling &other finished masonry Item complete.(For 'B' class pipe ISI marked (IS-1161-68)) (B)G.I. Pipe ‘B’ class 32 mm dia.
Supplying and drawing single core PVCinsulated cable FRLS with copper multistrand conductor ISI marked in existing rigidPVC casing andcapping/conduit in surfaceor concealed as per specification. (A) 3 X 2.5 sq. mm. (3 WIRE )
(1) The contractor is responsible for approval of Transformer Sub Station, H.T./L.T. lines/testing of L.T.C.T. meter from competent authority of Electrical Inspector and energisation/ commissioning of sub-station H.T./L.T. lines and necessary shut down from MPPKVVCL. No extra payment will be done for this job. (2) Quantities/items may increase/decrease as per site conditions. (3) Ready to carryout maintenance work if failure of any equipment i.e. transformer, Line in colony 5%amount of total work done withheld for maintenance work within 5 year period from the date handing over.
Avinash Chopra
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .