Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹29.0 L+₹48,075 (1.69%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹29.8 L+₹1.3 L (4.65%)Rejected-Finance TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹30.3 L+₹1.8 L (6.44%)Rejected-Finance BASEMENT PLOT NO 17 4657 21 ANSARI ROAD CENTRAL DELHI NEW DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹32.0 L+₹3.5 L (12.3%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹50.0 L
EMD Value
₹99,940
Closing Date
6 Feb 2020, 6:00 pmClosed
GE E/M BASE HOSP DELHI CANTT
GE E/M BASE HOSP DELHI CANTT
COMPREHENSIVE MAINTENANCE AND OUTSOURCING OF INTERNAL ELECTRIFICATION WITH ALLIED WORKS AT CABINET SECTT UNDER GE E/M BASE HOSPITAL DELHI CANTT-10
2020_MES_311873_1
GE/BH-53/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE E/M BASE HOSP DELHI CANTT
Meeting enlistment criteria of MES with regard to having satisfactory completed requisite value works annual turnover, working capital, fixed assets. No recovery outstanding in any govt dept security clearance etc.
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSP DELHI CANTT
₹99,940
Yes
6 Mar 2020
4 Jan 2020
8 Feb 2020
4 Jan 2020
6 Feb 2020
18 Jan 2020
Amount
Outsourcing services of internal electrical supply, complaint of day to day maintenance of existing electrical point wiring, electrical fitting, light short circuit earth leakage, no light from switch rooms DBs in corridoors etc repairs to all other electrical fittings/fixures at site and make the electric supply functional in general shift from 0930 hrs to 1730 hrs comprising by deploying minimum three electrician and three helper including note down the complaint in complaint register,distribution to the tradesman,collection of maintenance store from store yard of electric section etc complete all as specified and directed .
Note : (a) All the T&P items like eight feet height aluminium folding with self supported ladder 3 Nos,drill machine with bits of any size three Nos will be provided by the contractor at no extra cost o the department at the time of commencement of work other wise a penalty of Rs 500/day shall be recovered from the contractor dues.Tool Bags required for attending the complaint shall also be provided by contractor to the tradesmen with dress code,name of the indls and firm etc.
(b) All the stationery i.e complaint register, job card dockets and other connected register related to the work shall be arranged and to be maintain by the contractor.
(c) Stores reqd for day to day maintenance for above repairs shall be issued by the department on complaint basis at store located within complex.
(d) All the retrieved material shall be the property of Contractor with Sch of credit as shown on credit schedule..
(e) Contractors are advised to visit the site before quoting rates.
(f) Contractor shall be panelised @ Rs. 200/- per complaint/ day, if he fails to attend and rectify the complaint within 8 hours of lodging the complaint either personally or telephonically. In this regard the decision of the Engr-in-Charge shall be final & binding.
(g) Contractor shall provide the full manpower on Sunday/Saturday/Holiday on direction of Eng-in-Charge by verbally/telephonically otherwise recovery RS- 400/person/day shall be recovered from the contractor dues.
(h) The employed electrician should be suitably qualified in concerned trade or shall have minimum 05 years experience in internal electrification services.
(j) Work shall be carried out as per modern engineering practice including day to day maintenance record register, duty roster, attendance register etc complete alongwith general tool safety measures on conveyanee/ transportation uniform etc.
(k) Contractor will submit the nominal roll and qualification of electricians and helper within 15 days of acceptance.After that period a sum of Rs 500/day shall be recovered from the contractor dues.
(l) all workers shall wear proper uniform ,failing whitch recovery of 100 /person/day shall be recovered from the contractor.
(m) Any stores required for rectification of electric complaints other than item mentioned in CA as provided by the department shall also required to be fixed by the persons employed under subject CA without any extra cost to the department..
(n) In case any tradesmen found absent during the period mentioned above (i.e 0930 hrs to 1730 hrs) a penalty of Rs 500/.person/day shall be recovered from the contractor dues.
(o)All consumable items like cotton waste,PVC insulation tape,thimbles,nut bolts,screws are deemed to be included in quoted rate.
(p)The material under this contract which is as Supply only be consumed under this item described here above.
Supply only in replacement of Metal clad plug top 20 Amp 2P+E, 240 volts Cat No-650008 Make:- Legrand/Hager
Supply only in replacement of Metal clad Socket 20 Amp 2P+E, 240 volts Cat No-650009 Make:- Legrand/Hager
Supply only in replacement of Metal clad plug top 10 Amp 2 pin, 240 volts Make:- Legrand/Hager
Supply only in replacement of Metal clad Socket 10 Amp 2 pin, 240 volts Make:- Legrand/Hager
Supply & Fixing in replacement of Constant Current LED driver for downlight 18 W ,Model No : H18w-L2 ,IS 15885 (part 2/sec 13 suitable for downlight 18 W Make-Philips /Havells/CG
Supply & Fixing in replacement of Constant Current LED driver for Recess/Surface mounted 36 W ,Model No : LD27V1100PA (28 mm) suitable for 2X2 ft 36 W Make-Philips /Havells/CG
Supply only in replacement of switch socket combination 5 in 1, 5/15 Amps flush type as per existing model and size complete all as specified and directed . Make- Anchor/Legrand/Crab tree
Supply only in replacement of switch socket combination 2 in 1 3 pin 5 Amps flush type as per existing model and size complete all as specified and directed . Make- Anchor/Legrand
Supply only in replacement of single core copper conductor PVC insulated unsheathed FRLS 1100 Volt grade flexible 1.5 Sqmm size,multistranded unsheathed complete all as specified and as directed. Make - Havells/ Finolex/ Polycab
All as per ser item No.10 here-in- before but 2.5 Sqmm.
All as per ser item No.10 here-in- before but 4 Sqmm.
All as per ser item No.10 here-in- before but 6 Sqmm.
All as per ser item No.10 here-in- before but 10 Sqmm.
All as per ser item No.10 here-in- before but 25 Sqmm.
Supply only in replacement of Twin core copper conductor PVC insulated unsheathed FRLS 1100 Volt grade flexible 2x0.75 Sqmm size,multistranded unsheathed complete all as specified and as directed. Make - Havells/ Finolex/ Polycab
All as per ser item No.16 here-in- before but 2x1.5 Sqmm.
Supply only in replacement of 16 Amp & 6 Amp,combined unit box with 2 fixing holes complete all as specified and as directed. Make - Anchor/Legrand/Cona
Supply only in replacement of 6 Amp, 2-in-1 Switch Socket Combined with box complete all as specified and as directed. Make - Anchor/Legrand/Cona.
Supply only in replacement of Switch Piano flush type, single pole, one way 5 Amp complete all as specified Make - Anchor/Legrand/Cona.
Supply only in replacement of switch piano , flush type , single pole , one way15 amps complete all as specified.Make - Anchor/Legrand/Cona.
Supply only in replacement of socket out let 2-in-1 pin 5 Amps complete all as specified and as directed.Make - Anchor/Legrand/Cona.
Supply only in replacement of socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified.Make - Anchor/Legrand/Cona.
Supply only in replacement of PVC Non metallic conduit of external dia 20 mm including of all tees, bends elbow, reducers bell mouth tube end and fixing accessories such as coupler, lock nuts, saddles, pipe hooks etc but exclusive of junction boxes complete all as specified and directed Make : AKG/MK
All as per Srl item No- 24 here-in-before but 25 mm dia.
All as per Srl item No- 24 here-in-before but 32 mm dia.
Supply only in replacement of PVC casing capping of size 20 mm including of all tees, bends elbow reducers bell mouth tube end and fixing accessories complete all as specified and directed. Make : AKG/MK
All as per Srl item No- 27 here-in-before but 25 mm dia.
Supply only in replacement of MCB SP 25 Amps, 240 Volts, 10 kA, 'C'Curve.Make : Legrand/L&T/Schneider
Supply only in replacement of MCB SP 32 Amps, 240 Volts, 10 kA, 'C'Curve.Make : Legrand/L&T/Schneider
Supply only in replacement of MCB SP 40 Amps, 240 Volts, 10 kA, 'C'Curve.Make : Legrand/L&T/Schneider
Supply only in replacement of MCB SPN 40 Amps, 240 Volts, 16 kA, 'C'Curve. Make : Legrand/L&T/Schneider
Supply only in replacement of MCB SPN 63 Amps, 240 Volts, 16 kA, 'C'Curve. Make : Legrand/L&T/Schneider
Supply only in replacement of MCB TPN 40 Amps 16 KA complete all as specified and directed.Make : Legrand/L&T/Schneider
Supply only MCB TP 40 Amps 16 KA complete all as specified and directed.Make : Legrand/L&T/Schneider
Supply only in replacement of MCB TPN 63 Amps 16 KA complete all as specified and directed.Make : Legrand/L&T/Schneider
Supply only in replacement of MCB TP 63 Amps 16 KA all as directed at site.Make : Legrand/L&T/Schneider
Supply only in replacement of MCB TP 100 Amps 10 KA complete all as specified and directed. Make : Legrand/L&T/Schneider
Supply only in replacement of MCB FP 100 Amps 10 KA complete all as specified and directed.Make : Legrand/L&T/Schneider
Supply only in replacement of DPX3 160 Thermal magnetic MCCB TP 125 Amps 36KA complete all as specified and directed. Make- Legrand cat No-420086/L&T/Schneider
Supply only in replacement of DPX3 160 Thermal magnetic MCCB TP 160 Amps 36 KA all as directed at site. Make- Legrand Cat No-420087/L&T/Schneider
Supply only in replacement of DPX3 250 Thermal magnetic MCCB TP 250 Amps 36 KA all as directed at site. Make- Legrand Cat No-420239/L&T/Schneider
Supply only in replacement of DPX3 630 Thermal magnetic release MCCB 4 Pole 400 Amps 50KA complete all as specified and directed. Make- Legrand Cat No-422021/L&T/Schneider
Supply only in replacement of DPX3 630 Thermal magnetic release MCCB 4 Pole 630 Amps 50KA complete all as specified and directed. Make- Legrand Cat No-422023/L&T/Schneider
Supply only in replacement of Red/ Green 0.5 watt LED light 220/240 Volt complete all as specified and directed.Make - Philips/Havells
Supply only in replacement of insulation Tape Red/Yellow/Blue/Green/ Black 20mm wide and 25mtr length complete IS 7809 complete all as specified and directed.Make : Anchor/kalinga
Supply & Fixing in replacement of sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20P+E Amps. Make- Havells/Legrand/L&T
Supply only in replacement of electronic fan regulator stepped type complete all as directed at site. Note : The rate for fixing charges and taking down and making good to disturbed surfaces (if any) in all respect etc shall be deemedincluded in srl Item No 01 of SCH 'A' SEC- I
Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) complete with all fittings such as switches, ceiling roses, pendants, regulators, Sockets etc removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
M&L point wiring with insulated unsheathed Cable 1.5 Sqmm multistranded FRLS copper conductor 1100 volt grade cable intoPVC conduit pipe with sunken terminal MS boxes laminated sheet cover 3mm thick and incl provision of earth wire PVC insulated unsheathed 1.5 Sqmm stranded FRLS copper conductor single core cable connected to common earth dolly along wall/roof including making good disturbed surface to match with existing finish with plaster for one light /fan controlled by one way switch 6amp ISI marked. (make of Conductor Finolex/Havells/Polycab)
All as per ser item No- 50 here-in-before but one 3pin socket out let 5 Amps on the same board
All as per ser item No- 50 here-in-before but one 3pin socket out let 5 Amps on the Independent board
All as per Srl items No-50 here-in-before but point wiring with 2.5 Sqmm for 15 Amp socket out let with 1.5sqmm earth continuity.
S & F in replacement of modular Switch Piano flush type, single Module 6 Amp complete all as specified (make :- Anchor/Legrand /Crabtree)
S&F in replacement of Modular switch piano , flush type , single pole 16 amps complete all as specified. (Anchor/Legrand/Crabtree).
S&F in replacement of modular socket outlet 2-in-1, 3 pin ,6&16 Amp , flush type complete all as specified. ( Anchor/crabtree/Legrand.
S&F in replacement of modular socket outlet 2-in-1, 3 pin ,6 Amp , flush type complete all as specified. ( Anchor/crabtree/Legrand.
S&F in replacement of modular step type fan regulator complete all as specified.(Make:-Anchor/Legrand).
Taking down carefully copper/aluminium Sub main wiring of size 4/6 Sqmm from surface/concealed /existing conduit of any height removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
All as per Srl item No-59 here-in-before but 10 Sq,mm
M&L Sub main wiring complete with 2x4 sqmm , single core , multi stranded copper conductor FRLS PVC insulated and sheathed cable 1100 Volts grade , drawn including PVC concealed/surface conduit along walls roofs etc including 2.5 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly . Make :- Havells/Finolex/Polycab.
All as per Srl item No-61 here-in-before but 2X 6Sqmm and 1X 4 Sq,mm for Earth wire
All as per Srl item No-61 here-in-before but 2X10 Sqmm and 1X 6 Sq,mm for Earth wire
Taking down old /Unserviceable distribution board by disconnection of electric connection carefully SPN DBs, Main Switch making good to disturbed surface complete all as specified and as directed.
Taking down Old Unserviceabl MCB DBs / Main Switches making good to distrubed surface complete all as specified and as directed.
Supply and fixing DB VTPN 8 way IP 43 IK-09 with metal door suitable for Provision of MCCB DPX 160, 4P 36 KA 160 Amp,housing MCB's complete all as specified and as directed. Make -Legrand Cat Part No -507747/Simens.
Supply and fixing MCB DB SPN 4 way IP 43-IK-09 with metal door suitable for housing of MCBs complete all as specified and as directed. Make -Legrand Cat Part No -507610/Simens.
Supply and fixing MCB DB SPN 8 way IP 43-IK-09 with metal door suitabl for housing of MCBs complete all as directed by Engineer-in- Charge. Make -Legrand Cat Part No -507611/Simens.
S & F in replacement of energy efficient LED Round shape surface mounted downlight fitting 18 Watt,230 Volt of 6000 K couler temp ,decorative ultra slim linear LED lighting fixture with extruded Al. heat sink, environmental friendly, energy efficient, wall mounted batten integrated electronic driver complete all as specified and directed.(Havells Cat No ENDURANEOSURFACEDLS18WLED857S or equivalent in /Wipro/philips)
S&F in replacement LED Recess mounted 2x2 ft luminaire fitting LED 34/36 Watt cast aluminium housing, toughened glass,silicon gaskect, high power LED with lens for uniform istribution pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including clamps and nut bolts for fixing complete all as specified and directed .(Make - havells Cat No:- PLUTONEO2X2PLR34WLED857S or equivalent in philips/Wipro)
S&F in replacement of LED Surface mounted 2x2 ft luminaire fitting LED 34/36 Watt cast aluminium housing, toughened glass,silicon gaskect, high power LED with lens for uniform istribution pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including clamps and nut bolts for fixing complete all as specified and directed.(Make - havells Cat No:- PLUTOSURFACE2X2PLS34WLED857S or equivalent in philips/wipro)
S&F in replacement of LED surface mounted 4x1 ft luminaire fitting LED 36/40 Watt cast aluminium housing, toughened glass,silicon gaskect, high power LED with lens for uniform istribution pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including clamps and nut bolts for fixing complete all as specified and directed.(Make - Havells Cat No:- PLUTONEO4X1S36WLED857S or equivalent in philips/wipro)
S&F in replacement of LED surface mounted Regal batten for LED tube fitting 4 ft suitable for 1x20w tube rod for T5/T8 lamps pre-wired and electric connection with both sides bipin holders including clamps and nut bolts for fixing complete all as specified and directed.(Make - Havells Cat No:- REGALBATTEN8UPTO1X22WSSBSWH or equivalent in philips/CG)
S&F in replacement of Photon ultra LED tubelight Single side connection 20W suitable for 1x20w T5/T8 fittings and pre-wired electric connection fixing complete all as specified and directed.(Make - Havells Cat No:- phoyonultra1213t8sstl20wled865spc or equivalent in philips/CG)
S & F in replacement of PVC box suitable for fixing of modular Switches/sockets of 3 modules complete all as specified and directed.
S & F in replacement of PVC box suitable for fixing of modular Switches/sockets of 6 modules complete all as specified and directed.
S & F in replacement of PVC box suitable for fixing of modular Switches/sockets of 8 modules (2 row x 4 modules) complete all as specified and directed.
S & F in replacement of modular white plate and cover suitable for fixing of modular Switches/sockets of 3 modules complete all as specified and directed. Make: Anchor/ Legrand
S & F in replacement of modular white plate and cover suitable for fixing of modular Switches/sockets of 6 modules complete all as specified and directed.Make: Anchor/ Legrand
S & F in replacement of modular white plate and cover suitable for fixing of modular Switches/sockets of 8 modules (2 row x 4 modules) complete all as specified and directed.Make: Anchor/ Legrand
(i) The estimated cost of the work in respect of BOQ Sr iterm No 01(as based on minimum wages rates issued vide central/state) is Rs 14,79,20.00 . If the quoted amount is found less than the estimated cost of Sr item No 01 of BOQ and tender of lowest bidder is considered for acceptance, then the lowest bidder will have to deposit FDR in favour of Accepting officer for the difference in estimated cost and Accepted amount in respect of BOQ Sr item No 1 within 30 days from date of acceptance. In case the said FDR is not submitted within 30 days the amount in question shall be recovered from contractor’s first RAR/Final bill whichever is earlier. However the FDR/recovered amount shall be released to the contractor after satisfactory completion of work. Attention is further invited added that when the amount of said recovery mentioned herein above is less than the amount of performance security as indicated under Clasue 02 on page 04 of CA and Clause 12 on page 11 of CA, no FDR is required to be submitted for quoting less rate against BOQ Srl Item No 01. However if the amount of performance security is less than the FDR to be submitted for less quoting rate, the difference of performance security amount and FDR amount(for less quoting rates) shall be deposited by the lowest bidder (whose tender is accepted) in the form of FDR for difference amount over and above performance security within 30 days from the date of Acceptance.
M/S ANIL KUMAR
GLIBS CONSTRUCTION
VINAY ENTERPRISES
SETHI ENTERPRISES
SANJEEV ENTERPRISES
ASHUTOSH BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .