| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.2 LAccepted-AOC CHESHIRE HOME ROAD SHAKTI KUNJ BARIATU RANCHI 834009 | RANCHI | JHARKHAND | 834009 | ₹24.2 L Quoted ₹24.5 L | 1 | Accepted-AOC ok |
| 2 | 2₹24.9 L+₹34,483 (1.41%)Rejected-Finance PURALLIA ROAD KANTATOLI RANCHI 834001 | RANCHI | JHARKHAND | 834001 | ₹24.9 L+₹34,483 (1.41%) | 2 | Rejected-Finance Quoted rate more than L1 |
| 3 | 3₹26.2 L+₹1.6 L (6.72%)Rejected-Finance B 1203 VRINDA RESIDENCY BARIATU ROAD RANCHI JHARKHAND 834009 | RANCHI | RANCHI | JHARKHAND | 834009 | ₹26.2 L+₹1.6 L (6.72%) | 3 | Rejected-Finance Quoted rate more than L1 |
| 4 | 4₹26.8 L+₹2.2 L (9.07%)Rejected-Finance KRISHNA NAGAR BOOTY RANCHI 835217 | RANCHI | JHARKHAND | 835217 | ₹26.8 L+₹2.2 L (9.07%) | 4 | Rejected-Finance Quoted rate more than L1 |
| 5 | 5₹27.3 L+₹2.7 L (11.1%)Rejected-Finance | ₹27.3 L+₹2.7 L (11.1%) | 5 | Rejected-Finance Quoted rate more than L1 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
25 Oct 2023, 6:00 pmClosed
GE Dipatoli
GARRISON ENGINEER MILITARY ENGINEER SERVICES DIPATOLI CANTT PO- HOTWAR RANCHI Pin- 834012
Repair/Maint to unserviceable Internal wiring, light fittings in Md and OTM buildings of Engr Regt, ASC Bn, EME Bn, Fd Hosp (423), IDSR, INF Div, Mahar Bn, Div Pro, Station HQ, CWE, GE area under GE Dipatoli and Repair and Maintenance of ceiling fans
2023_MES_620800_1
8000/1925/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
Dipatoli
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Dipatoli
₹70,000
Yes
22 Dec 2023
27 Sept 2023
27 Oct 2023
27 Sept 2023
25 Oct 2023
11 Oct 2023
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc, complete all as specified and directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and directed.
Taking down old/unserviceable TPN/SPN DBs MCB DBs of any capacity by disconnection of electric connection including MCCB, MCBs ,Isolators,etc and making good to disturbed surface complete all as specified and directed.
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade , drawn through PVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screw as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing of switch and scoket including cutting chases in wall making good to disturbed surface and matching with existing surfaces , complete all as specified and directed.
All as per Ser item No 4 here-in-before but one 3 Pin Socket out let 5 Amps on the same board , complete all as specified and directed.
All as per Ser item No 4 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board , complete all as specified and directed.
All as per Ser item No 4 here-in-before but one bell/buzzer point controlled by one push button on the independent board , complete all as specified and directed.
All as per Ser item No.4 here - in - before but one light point controlled by two 2 - way switches,with wire 1.5 Sqmm size , complete all as specified and directed.
All as per Ser item No 4 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly, complete all as specified and directed.
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade , drawn through PVC Casing caping 20/25 mm on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screw as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed.Note: The rate quoted is deemed to be included for Phenolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing of switch and scoket including cutting chases in wall making good to disturbed surface and matching with existing surfaces, complete all as specified and directed.
All as per Ser item No 10 here-in-before but one 3 Pin Socket out let 5 Amps on the same board , complete all as specified and directed.
All as per Ser item No 10 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board, complete all as specified and directed.
All as per Ser item No 10 here-in-before but one bell/buzzer point controlled by one push button on the independent board, complete all as specified and directed.
All as per Ser item No.10 here - in - before but one light point controlled by two 2 - way switches,with wire 1.5 Sqmm size, complete all as specified and directed.
All as per Ser item No 10 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly, complete all as specified and directed.
S&F Switch Piano type 2 way switch 5 amp 230 v complete all as specified and directed at Site, complete all as specified and directed.
Supply and fix Switch Piano type, single pole, one way 5 Amp complete all as specified & directed.
S&F Switch piano type , single pole , one way 15 Amps complete all as specified and directed.
S&F Socket out let 2-in-1 2/3 pin 5 Amps complete all as specified and directed.
S&F Socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified & directed.
S&F in replacement electric Bell, ding dong type AC 230 Volt single pole complete all as specified & directed .
S&F in replacement Bell push 5 Amps for electric Bell/Buzzer, AC 230 Volt single pole complete all as specified & directed.
S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed.
S&F electronic regulator step type 230 Volts single phase 120 watt complete all as specified and directed at site.
M&L for lamp holder , PVC /Polycarbonate type with back plate suitabl for batten fittings complete all as specified and directed at site.
Supply and Fix modular switch one way 6 Amp 240 volts one module complete all as specified and directed at site.
S&F Modular Sheet Cover of size up to 8"X10" comple all as specified and directed.
S&F Sheet Cover of size up to 8"X10" comple all as specified and directed.
Supply and Fix modular switch two way 6 Amp 240 volts one module complete all as specified and directed at site.
Supply and Fix modular bell push switch one way 5 Amp 240 volts one module complete all as specified and directed at site.
Supply and Fix modular switch one way 16 Amp 240 volts one module complete all as specified and directed at site.
Supply and Fix socket modular one way 6 amp 240 volts two module complete all as specified and directed at site.
Supply and Fix socket modular one way 16 amp 240 volts two module complete all as specified and directed at site.
Supply & Fix TV socket modular one module complete all as specified and directed at site.
Supply & Fix Telephone socket modular one module complete all as specified and directed at site.
Supply & Fix regulator modular step type one way 220 volt two module complete all as specified and directed at site.
Supply and fix in replacement of modular USB Charger complete all as specified and directed at site.
Supply and fix in replacement Blanking Plates for covering of MCB DB open space complete all as specified and directed at site.
Supply and fix in replacement switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type as per existing model and size complete all as specified and directed .
Supply and fix in replacement switch socket combination 2 in 1 3 pin 5 Amps flush type as per existing model and size complete all as specified and directed.
S&F in replacement of sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 Amps to 32 Amps complete all as specified and directed at site.
M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceiling etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
All as per ser item No-42 here-in-before but 2X2.5 Sqmm and 1X 2.5 Sqmm for Earth wire , complete all as specified and directed.
All as per ser item No-42 here-in-before but 2X4 Sqmm and 1X 4.0 Sqmm for Earth wire , complete all as specified and directed.
All as per ser item No-42 here-in-before but 2X 6 Sqmm and 1X 6.0 Sqmm for Earth wire , complete all as specified and directed.
M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor FR PVC insulated and unsheathed FRLSH cable 1100 Volts grade, drawn in with and including PVC casing / caping 20/25 mm dia as per site requirement along walls/ceiling etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire (Phase red colour, neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
All as per ser item No-46 here-in-before but 2X2.5 Sqmm and 1X 2.5 Sqmm for Earth wire , complete all as specified and directed.
All as per ser item No-46 here-in-before but 2X4 Sqmm and 1X 4.0 Sqmm for Earth wire , complete all as specified and directed.
All as per ser item No-46 here-in-before but 2X 6 Sqmm and 1X 6.0 Sqmm for Earth wire , complete all as specified and directed.
M&L fixing PVC Casing caping 20/25 mm on wall/ceiling ,including replacement of old u/s PVC cashing caping, for exesting old servicable point wiring for existing old servicable point wiring of 1.5mm,/2.5mm,/4mm & 6 sqmm , Existing wiring/Submain wiring drawn through new PVC Casing caping/conduit on wall/ceiling ,including replacement , complete all as specified and directed. (Note:- The rate quoted is deemed to be included for taking down of U/S PVC Casing caping/ conduit including cutting &fixing charges & making good to disturbed surface and matching with existing surfaces.)
Supply and fix MCB DB SPN 4 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site.
Supply and fix MCB DB SPN 12 way double door with metal door suitabl for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directedcomplete all as specified and directed at site.
Supply and fix MCB DB TPN 4 way with metal door suitable for Provision of incommer and out going MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
Supply and fix in replacement MCCB 100 Amp 415 volts 16kA 4 pole complete all as specified and directed at site.
Supply and fix in replacement MCCB 63 Amp 415 volts 16kA 4 pole complete all as specified and directed at site.
S&F in replacement of MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of MCB SP 63 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles , complete all as specified and directed.
S&F in replacement of MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles , complete all as specified and directed.
S&F in replacement of MCB DP 63 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of isolator DP 40 Amps 'C' Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of isolator DP 63 Amps 'C' Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of isolator TPN 40 Amps 'C' Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of isolator TPN 63 Amps 'C' Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of isolator TPN 100 Amps 'C' Series fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed.
S&F in replacement of LED tube light fitting 20 watt 230 Volt decorative ultra slim linear LED Lighting with polycarbonate housing & integrated electronic driver , including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed at site.
S&F in replacement of LED tube light fitting 18 watt 230 Volt decorative ultra slim linear LED Lighting with polycarbonate housing & integrated electronic driver , including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed at site.
S&F in replacement of Lienear & compact 9 wat LED mirror light with decorative grey end caps,polycarbonate body and ribbed opal diffuser including 2/3 core flexible copper wire with flexible pipe ceiling rose to light fittings complete all as specified and directed at site.
S&F in replacement of building LED security light fitting 35 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device. luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed at site.
Supply and fix MCCB DB TPN 4 way with metal door suitable for Provision of incommer as MCCB and out going MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed.
S&F in replacement of Ultra slim LED panel tube light fitting 36 watt 230 Volt made from extruded aluminium housing frame (recesss/pendant) 2' x2' Complete with all accessories internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed at site.
S&F in replacement PVC ventilating air fan single phase 250 mm sweep complete with louver shutter and including making of hole suitable size fan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed.
S&F in replacement of ventilating air fan single phase 300 mm sweep complete with louver shutter and including making of hole suitable size fan base after cutting of brick/stone wall /suitable size of water proof ply wood complete all as specified and directed.
Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductor cable all as directed.
Excavation in trenches in loose/soft soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete, all as specified.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Returning & filling in including spearing, leveling watering and well ramming in layers not exc 25cm thick , complete all as specified and directed.
Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed.Note : Punned down thickness shall be considered for measurement , complete all as specified and directed.
Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed.
M &L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr in Charge.Note :- i) Earthing test must be carried out in presence of Engr-in-Charge. ii) The earthing result not more than 2 Ohms or disered earth resistance value. iii) Megger required for testing will be be provided at site by the contractor. iv) Contractor shall submit earth resistance testing report before submission of bill.
M&L for repairs to geysers by disconnecting the electrical and water supply connctions, repairs to inner container by brazing and welding and checking for any leakages and carrying out leak proof test at 2.5 Kg/sqcm with and including two coats of painting with synthetisc enamel paint and fixing back the geyser and connecting electrical and water supply connections in same or different location complete all as specified and as directed.
Supply & Fix in replacement of Heating element ISI marked 1500 watts, 230 volts complete all as directed.
Supply & Fix in replacement of Heating element ISI marked 2000 watts, 230 volts complete all as directed.
Supply & Fix in replacement of Thermostat ISI marked, Temp range 45°C to 100° C, 230 volts complete all as directed.
Supply & fix in replacement lamp indicator for geyser ( Red / Green ) including bulb and connections complete all as specified and as directed.
Dismantling carefully Ceiling Fans/ Exhaust fans (any make) for cutting down and removing old copper winding wire and rewinding the same with new super enamelled copper wire of suitable size including providing insulation by varnishing, oiling & greasing etc. complete and reassembling the ceiling fan including testing in E/M Store Yard & replacement of PVC flexible wire of size 23/0.0076 twin core twisted copper cable complete all as specified and directed of following sizes .Note :- The super enameled copper winding wire to be provided for the above shall be of any make. (a) 12" /15” sweep exhaust fan
(b) 18” sweep Exhaust fan , complete all as specified and directed.
(c) 48" sweep ceiling fan , complete all as specified and directed.
(d) 56" sweep ceiling fan , complete all as specified and directed.
Taking out old unserviceable Gun metal bushes from the dismantled rotar shaft and supply and fix suitable new Gun metal bushes for Ceiling Fan (any make) of size 48”/56” sweep complete all as specified and directed.
Taking out old unserviceable oil capacitor and supply and fix new capacitor 440 Volts, 2.5 MFD to 3.0 MFD as required depending upon the model of ceiling fan (any make) of size 48”/56” sweep, including plastic holder for capacitor.
Taking out old unserviceable oil capacitor and supply and fix new capacitor 440Volts, 4.0MFD for exhaust fan (any make) of any size, including plastic holder for capacitor.
Scraping out of old paint from the body, blades, down rod etc of Ceiling Fan complete and filling in cavities with approved filler and M&L for spray painting with two coat of synthetic enameled paint first quality (Glossy/ White/ Pale gray) on the body, blades, down rod etc and writing MES No on the body of ceiling fan with black synthetic enameled paint complete all as specified & directed for the folloowing :- (a) Ceiling fan (any make) of size 48” sweep
(b) Ceiling fan (any make) of size 56” sweep, complete all as specified and directed.
Taking out unserviceable old ball bearing from the dismantled rotor shaft and supply and fix suitable size new ball bearing for following:-. Note :- The new ball nearing to be provided against Ser No.2 above shall be of Make – “SKF/NBC/TATA (a) Ceiling Fan ( any make) of size 48" sweep.
(b) 56" sweep ceiling fan , complete all as specified and directed.
(c) 12" /15” sweep exhaust fan , complete all as specified and directed.
(d) 18” sweep Exhaust fan , complete all as specified and directed.
Taking down/Lowering carefully Ceiling Fan/Exhaust Fans from site any type any make from any height in bldgs for carrying out repairs work as per items here-in-before and re-fixing in the same position after necessary testing complete all as directed by Engineer-in-Charge. Note :- Items of consumable store such as oil, grease, waste oil, wire brushes cotter pin/split pin and the like shall be contractor’s supply and quoted rates in schedule ‘A’ shall be deemed to include the cost of such items , complete all as specified and directed.
Taking out old unserviceable bolts/nuts with ‘U’ Clamps for hanging ceiling fan and S&F new bolts/nuts & ‘U’ clamps of required length and size for 48”/56” sweep ceiling fans (any make).Note:-Unit “EACH SET” means one bolt of required length & one nut with ‘U’ clamps , complete all as specified and directed.
S&F in replacement aluminium fabricated blades of approved quality for 1200mm-sweep ceiling fan , complete all as specified and directed..
S&F in replacement aluminium fabricated blades of approved quality for 1400mm-sweep ceiling fan , complete all as specified and directed..
Labour only for dismantling existing unserviceable down rod,& nut bolt cutting, drilling, fabrication and fixing of down rod suitable for hanging of ceiling fan of any make and size of GI Pipe 15mm dia light grade suitable for cable entry and fixing arrangement including nuts bolts on both ends as directed.
Supply only GI Pipe light grade 15mm dia for down rod all as specified and directed.
Supply and Fix in replacement of body nuts with spring washers for fixing the fan blades complete of required sizes, complete all as specified and directed.
Supply and Fix in replacement canopy PVC suitable for various type of ceiling fan as per sizes , complete all as specified and directed.
Raju Electrical and Refrigeration Works
arics infrastructure
M/S OMANIA ENTERPRISES
M/S SHAMBHU SHARAN SINGH
Excel Enterprises
M/s Animesh Kumar & Co.
M/S ROHIT CONSTUCTION
M/s Ray construction
M/S ABHAY KUMAR AND BROTHERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .