| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 CrAccepted-AOC 2A IHDP BUSINESS PARK SECTOR 127 NOIDA UTTAR PRADESH 201304 | NOIDA | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201304 | ₹6.7 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹6.8 Cr+₹11.5 L (1.72%)Rejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹6.8 Cr+₹11.5 L (1.72%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹7.7 Cr+₹1.0 Cr (15.1%)Rejected-Finance | ₹7.7 Cr+₹1.0 Cr (15.1%) | L3 | Rejected-Finance Other than lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical As per selection performa attached |
| Sl No | Description | Qty | Unit | vijay builders L2 | Aggarwal Brothers and company L3 | ANEKTOS HYBRID BUILDINGS PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|
| 1.00Sch 'A' Part-I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only. | ||||||
| 1.01 | Construction of block of 08 Qtr for Single Nursing Officers double storey using reinforcement precast concrete technology complete without mumty (non accessible roof) all as shown on typical floor plan drawings and as specified. | 2 | Each Block | 2,29,00,000 ₹4,58,00,000 | 2,60,00,000 ₹5,20,00,000 | 2,10,00,000 ₹4,20,00,000 Lowest |
| 1.02 | Construction of block of 01 Qtr for single Nursing Officers with attached one car parking, 01 Car parking (Garage) using reinforcement precast concrete technology complete with (non accessible roof) all as shown on drawings and as specified. | 1 | Each Block | 43,00,000 ₹43,00,000 Lowest | 54,00,000 ₹54,00,000 | 58,00,000 ₹58,00,000 |
| 1.03 | Construction of block of Car Garage (for 09 No Cars) using reinforcement precast concrete technology complete all as shown on drawings and as specified. | 1 | Each Block | 40,00,000 ₹40,00,000 Lowest | 50,00,000 ₹50,00,000 | 47,00,000 ₹47,00,000 |
| 1.04 | Construction of block of Car Garage (for 07 No Cars) using reinforcement precast concrete technology complete all as shown on drawings and as specified. | 1 | Each Block | 36,00,000 ₹36,00,000 Lowest | 40,00,000 ₹40,00,000 | 46,00,000 ₹46,00,000 |
| 2.00 | Total Amount of Sch 'A' Part - II (Internal Water Supply Work) | 1 | Lump sum | 4,47,815.12 ₹4,47,815.12 | 3,50,000 ₹3,50,000 Lowest | 3,50,000 ₹3,50,000 Lowest |
| 3.00 | Total Amount of Sch 'A' Part - III (Internal Electric Supply Work) | 1 | Lump sum | 16,47,005.22 ₹16,47,005.22 Lowest | 18,00,000 ₹18,00,000 | 18,00,000 ₹18,00,000 |
| 4.00 | Total Amount of Sch 'A' Part - IV (Plumbing Work) | 1 | Lump sum | 2,07,149.79 ₹2,07,149.79 | 1,80,000 ₹1,80,000 | 1,60,000 ₹1,60,000 Lowest |
| 5.00 | Total Amount of Sch 'A' Part - V (Area Drainage Work) | 1 | Lump sum | 3,39,252.72 ₹3,39,252.72 | 3,00,000 ₹3,00,000 | 2,90,000 ₹2,90,000 Lowest |
| 6.00 | Total Amount of Sch 'A' Part - VI (Sewage Disposal Work) | 1 | Lump sum | 2,06,180.5 ₹2,06,180.5 | 1,80,000 ₹1,80,000 | 1,70,000 ₹1,70,000 Lowest |
Tender Value
₹7.2 Cr
EMD Value
₹6.8 L
Closing Date
5 Feb 2026, 6:00 pmClosed
Chief Engineer Udhampur Zone
HQ Chief Engineer Udhampur Zone, PIN 900386, C/O 56 APO
PROVN OF DEFFI SINGLE LIVING NURSING OFFRS ACCN UNDER GE (N) UDHAMPUR (USING RAPID CONSTRUCTION TECH WITH PRECAST REINFORCED CEMENT CONCRETE TECHNIQUE)
2025_MES_746480_1
88007-A/E8
Open Tender
Civil Works
Lump-sum
212 days
Udhampur
As per NIT
8 documents required · 8 mandatory
₹3,000
GE (N) Udhampur
₹6.8 L
Yes
HQ Chief Engineer Udhampur Zone
2 Jun 2026
29 Dec 2025
7 Feb 2026
29 Dec 2025
5 Feb 2026
31 Jan 2026
30 Dec 2025 - 12 Jan 2026
15 Jan 2026
Construction of block of 08 Qtr for Single Nursing Officers double storey using reinforcement precast concrete technology complete without mumty (non accessible roof) all as shown on typical floor plan drawings and as specified.
Construction of block of 01 Qtr for single Nursing Officers with attached one car parking, 01 Car parking (Garage) using reinforcement precast concrete technology complete with (non accessible roof) all as shown on drawings and as specified.
Construction of block of Car Garage (for 09 No Cars) using reinforcement precast concrete technology complete all as shown on drawings and as specified.
Construction of block of Car Garage (for 07 No Cars) using reinforcement precast concrete technology complete all as shown on drawings and as specified.
Total Amount of Sch 'A' Part - II (Internal Water Supply Work)
Total Amount of Sch 'A' Part - III (Internal Electric Supply Work)
Total Amount of Sch 'A' Part - IV (Plumbing Work)
Total Amount of Sch 'A' Part - V (Area Drainage Work)
Total Amount of Sch 'A' Part - VI (Sewage Disposal Work)
Total Amount of Sch 'A' Part - VII (Road, Path and Culvert Work)
Total Amount of Sch 'A' Part -VIII (External Water Supply Work)
Total Amount of Sch 'A' Part - IX (External Electric Supply Work)
Total Amount of Sch 'A' Part - X (Compound Wall and Gate Work)
Sch 'A' Part - XI (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Point wiring complete with 1.5 sqmm PVC insulated, FRLSH, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc; metal flush boxes suitable modules as directed with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick, including modular top cover plate as per numbers of switch modules for fixing of modular switches,sockets,fan regulators, red colour indicator, blank plates etc. as approved colours and including 1.5 Sqmm PVC insulated multistranded FRLSH unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:-
One light/fan/bell point controlled by one switch
One 3/5 pin socket outlet, 5 Amp independent board
One socket outlet 3 Pin, 5 Amps on the same board
One two way point controlled by one two way switch
All as per Srl item No. 12 here-in-before but for power point control by one switch with 2.5 Sqmm nominal area PVC insulated single core multi standard copper conductor including earth wire with cable of size 2.5 sqmm.
Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLSH, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 20mm dia , medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green colour, connected to common earth dolly including taking down existing sub main wiring, complete all as specified and as directed. Note:- Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only.
Sub main wiring with two run of single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 20mm dia or above required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmm as earth continuity conductor connected to commen earth and earth dolly complete all as specified and directed. Note: - Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only.
Sub main wiring with four run of single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including two run of single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 sqmm as earth continuity conductor connected to commen earth and earth dolly complete all as specified and directed. Note: - Four run of 6 sqmm single core copper conductor cable and two run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only.
Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed. Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.
Sheet metal, VTPN distribution board (DB) fitted with DPX3, 160 MCCB, 04 way, (DPX3 -160 +12), complete with metal door, 415 volts rating and IP 56 protection the DB shall be fixed flush to wall and including all internal connection, necessary reducer lugs all as directed by Engr-in-Charge.
Switch air break, gang operated, triple pole, mechanical operated from ground level mounted on 12 insulators, outdoor type suitable for vertical installation single break provided with locking arrangement for operating handle including seven levers "NAVTAL LOCK" consisting of mild steel channel, operating rod 25mm dia, 'medium grade' GI pipe; conforming to IS: 1018 for current rating 400 amps, 11000 volts grade, complete all as specified.
Supply, installation, testing and commissioning of step down, Transformer 11000/433 volts, 3 phase 50Hz, minimum 100 KVA, copper wound, outdoor type with off load tap changing arrangement of HT side to very secondary voltage upto ± 7.5% in step of ± 2.5% including suitable cable entry boxes both on HT and LT to receive 95 sqmm 3core XLPE cable on HT side complete in all respect with std. accessories and fitment confirming to IS-1180 Part-I of 2014 and level-3 as per IS-1180 latest ammendments Dyn-11 connection complete all as specified and directed. The salient features of transformer shall be as follows: a) Rating and diagram plates. b) Earthing terminals = 02 No. c) Lifting lugs. d) Thermometer pocket. e) Air release hole with plug. f) Winding /Oil temperature indicator. g) Conservation with oil level indicator. h) Castors with locking provision. j) Silica Gel breather complete Note:- Transformer must be as per Energy efficiency level-3 of IS:1180:2014 with amendment No.4.
Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32x6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engineer-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.
Construction of PCC platform for transformer of size 3m x 2.5m and 1.5m high from ground level with brick construction in walls and steps, PCC 1:5:10 type E-2 in foundation, brick work in CM 1:4, 10mm thick rendering in CM 1:4 to walls, 50mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate). In flooring 40mm thick PCC on steps, painting to fencing with two coats of synthetic enamel paint over a coat of red oxide primer complete duly surrounded with XPM fencing of length not less than 15 meter and width not less than 10 meter complete with 40mmx5mm angle iron & 12mm dia steel bars, fixed on PCC gate pillers complete including sliding bolt, locking arrangements hinges and all accessories,shown on drawing No CE/TD/1129/96 sheet No. 1/2 & 2/2 complete all as specified.
Construction of valve pit of size (60x60x60)cm (Internal dimensions) using PCC (1:4:8) type D-2, using 40mm graded crushed stone aggregate for foundation 10cm thick and 100mm off sets on all sides, 230mm thick brick masonary walls built in cement mortar (1:6), 15mm thick rendering all around the masonry work in cement (1:6), for internal and up to 15cm below GL for external surfaces of walls, 50mm thick PCC (1:2:4) type B-1 coping with 20mm graded crushed stone aggregate including necessary form work for grouting including 3.15mm thick, MS top sheet cover double door with locking arrangement welded to MS frame made out of (50x60x6)mm angle iron frame fixed with hold fasts in coping including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer as finishes coat including necessary excavation in any kind of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as specified and directed.
Cutting the existing MS/DI/CI branch line pipe line of 50mm dia, from header carefully by means of gas cutter, removing the rusted MS pipe lines, making provision for joining new MS/CI/DI pipes of same size by welding MS flanges of suitable size and making leake proof joint including all jointing materials like bolts,nuts and gaskets required at site complete all as specified and as directed.
Cutting of existing road for crossing of MS/DI/CI/GI pipes for laying of any size pipes including necessary excavation and earth work including repairing the same with pre mix bituminous carpet, complete all as specified and directed.
Supply, installation and comminssioning of water cooler, fully stainless steel, electric driven single phase having storage capacity 80 litres and nominal cooling capacity of 40 Litres per hour, fitted with hermetically sealed air compressor operating on refrigerant R-134a or 410a, conforming to IS-1391 Part-II) complete all as specified and directed.
Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type, wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 2 KVA, complete all as specified and directed.
Desert cooler electric driven (single phase) heavy duty motor, three speed having nominal air flow, air cooler, boasts energy efficiency and durability in its double ball bearing motor and alloy metal blade for long quiet operation. Its high technology cooling medium offers a natural breeze and the water level indicator for easy running ensures continuous use with castor wheels for easy mobility and inverter compability with following features:- i) Type-Desert ii) Cooling Media-Honeycomb iii) Number of Speeds -3. iv) Blower/Fan-Fan v) Water Tank Capacity - 150L vi) Speed Control - Low, Medium, High vii) Air Delivery -11000 cfm viii) Air Throw Distance-90 ft ix) Motor Speed - 1350 RPM x) Air Deflection - 2 Ways xi) Blower/Fan Material - Metal xii) Oscillating Function, Water Level Indicator
Trial bore of 300mm dia upto 200m depth below ground level in any kind of soil strata including hard stone/boulder including electric logging, MS cap, MS flat iron clamps, reducing socket etc., complete all as specified and directed.
12.50mm graded crushed stone aggregate, complete all as directed by Engr-in-Charge.
300mm thick, broken brick filling in floors or filter media laid in layers not exceeding 15cm thick spread, levelled and rammed including watering complete all as specified.
300mm thick, fine aggregate (Sand) for filter media complete all as specified.
Perforated UPVC pipe of 150 mm bore complete all as specified..
MCB, Single pole, 240 volt, 40 Amp, 10KA rating, "B" curve, complete all specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Drg.pdf
Additional Documents • 0.57 MB
BOQ_835880.xls
BOQ • 0.44 MB
Tender.pdf
Tender Documents • 5.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .