Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.8 L+₹21,035.39 (0.63%)Rejected-Finance | L2 | Rejected-Finance High Rate |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
29 Dec 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintendent Engineer
UPSCIDCO LTD JHANSI
Supply of Labour and Electric work for Balance work of Residence Building Typ 2 (04 no) Fire Station Samthar Jhansi
2022_SCIDC_760345_1
32/SE/Jhansi/ET/2022-23
Open Tender
Civil Works - Others
Item Rate
270 days
Fire Station Samthar Jhansi
Please refer the tender Document
2 documents required · 2 mandatory
₹1,300
Yes
UPSCIDCO LTD
₹68,000
Yes
16 Jan 2023
19 Dec 2022
29 Dec 2022
19 Dec 2022
29 Dec 2022
19 Dec 2022
19 Dec 2022 - 29 Dec 2022
Amount
Supply of Labour for TYPE 4 Nos. Residence Building
First Class bricks works in 1:6 cement and coarse sand of 1.25F.M. mortar in foundation upto plinth supply of labour and T&P etc. required for proper completion of the work including providing scaffolding rope, chahlies fixing and removal. in foundation.
laying damp proof course 4.0cm thick with cement concrete 1:2:4 (1Cement: 2 Coarse sand : 4graded gtone aggregate 10mm nominal size) and curing complete.
Painting on D.P.C. with two coats of air blown bitumen 85/50 @ 1.7 kg/sqm approx including cost of fuel if any.
First Class bricks works in 1:6 cement and coarse sand of 1.25F.M. mortar in above plinth supply of all labour and T&P etc. required for proper completion of the work. But in super structure in 230mm wall including providing scaffolding rope, chahlies fixing and removal. In Super Structure.
First Class bricks works in 1:4 cement and course sand of 1.25F.M. mortar in above plinth supply of all labour and T&P etc. required for proper completion of the work. But in super structure in 115mm wall including providing scaffolding rope, chahlies fixing and removal. In Super Structure work.
Fixing of M.S. angle iron door, windows, ventilator frame made of approved M.S. angle iron wroght to required form including drilling hole, welding and reciting where necessary and also including supply of all materials, such as steel hinges of required size, nut & bolts etc. and also including all taxes, wastage and one coat of red oxide paint complete in all respect as per direction of Engineer in charge for proper completion of work at site of work.
Fixing of S.S. Railing Stair case
fixing of M.S. angle iron Z section window (approved Section) with Specified design of grill out side openable design of window and gril as per approved drawing 10mmsq bar 75mm c/c and 3no. bar group @ 75mm and four group in horizontal including providing stay and one coat of red oxide primer excluding glass pans.
fixing of M.S. grill of approved quality and drawing made of flat iron including supply of all materials, labour and T&P etc also including one coat of red oxide paint comp. in all respect as per direction of engineer-in-charge (S.I. No. New item 3)
First Class bricks works in 1:3 cement and course sand of 1.25F.M. mortar in above plinth supply of all labour and T&P etc. required for proper completion of the work. But in super structure in 115mm wall including providing scaffolding rope, chahlies fixing and removal.
R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast in the proportions of 1:1½;3 in outer work excluding supply of reinforcement and its bending but including its fixing and bending the same with 24 B.W.G.G.I. Binding wire and including necessary centering and shuttering etc. and also including Supply of all labours and T&P etc. required for proper completion of work binding wire cost being including in the item but for R.C.C. work.Column
R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast in the proportions of 1:1½;3 in outer work excluding supply of reinforcement and its bending but including its fixing and bending the same with 24 B.W.G.G.I. Binding wire and including necessary centering and shuttering etc. and also including Supply of all labours and T&P etc. required for proper completion of work binding wire cost being including in the item but for R.C.C. work.Lintel & Sunshed
R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast in the proportions of 1:1½;3 in outer work excluding supply of reinforcement and its bending but including its fixing and bending the same with 24 B.W.G.G.I. Binding wire and including necessary centering and shuttering etc. and also including Supply of all labours and T&P etc. required for proper completion of work binding wire cost being including in the item but for R.C.C. work.RCC for Beam
R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast in the proportions of 1:1½;3 in outer work excluding supply of reinforcement and its bending but including its fixing and bending the same with 24 B.W.G.G.I. Binding wire and including necessary centering and shuttering etc. and also including Supply of all labours and T&P etc. required for proper completion of work binding wire cost being including in the item but for R.C.C. work.R.C.C. Slab
Fixing and Removing Of Shuttering in Beam & Collumn
Mild steel or iron in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrougth to required shape as necessary including bending for proper completion of the work . R.C.C. work
filling of sand also including supply of all materials, labour and T&P etc. required for proper completion of the work.
Cement concrete in 1:4:8 with cement, sand and (22.40-43)mm granite stone ballast (crusher broken) in foundation including supply of all labours and T&P etc. required for proper completion of work.
15 mm thick plaster with cement mortar over brick work minimum thickness not to be less than 3/8”(10mm) thick including supply of all labour and T&P etc. required for proper completion of the work for proper completion of the work but with cement and approved coarse sand in 1:6 cement & fine sand of 1.25F.M. mortar. inside
12mm thick plaster with cement mortar over brick work minimum thickness not to be less than 3/8”(10mm) thick including supply of all labour and T&P etc. required for proper completion of the work for proper completion of the work but with cement and approved coarse sand in 1:6 cement & fine sand of 1.25F.M. mortar. in outside
laying of 8 to 10mm thick ivory or light shade Vitrified tiles of 600mmX600mm size in flooring or skirting laid with 1:3 ( 1cement : 3 Coarse sand) finishing with cement slurry & with pigment grouting & polishing complete i/c supply of all materials, labour T&P required for proper completion of work. in flooring
laying of 8 to 10mm thick ivory or light shade Vitrified tiles of 600mmX600 mm size in flooring or skirting laid with 1:3 ( 1cement : 3 Coarse sand) finishing with cement slurry & with pigment grouting & polishing complete i/c supply of all materials, labour T&P required for proper completion of work. in Skiting
laying of 20mm thick Kota stone flooring over 20mm thick base of Cement mortar 1:4 (1cement: 4 coarse sand) laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete.
fixing 5mm thick China white Glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials labour and tools etc. required for completion of the work . (Size of tiles upto 200X300 mm) in flooring
fixing 5mm thick China white Glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials labour and tools etc. required for completion of the work . (Size of tiles upto 200X300 mm) in wall
Making Grooves 10 to 12mm wide X 8mm deep in plaster on the wall or in ceiling etc.
Making of Drip Couars in same shade or faces i/x supply of all materials, labour etc.
fixing of 32cm (1.1/4”) thick Commercial Quality (Kanju) Sitapur ply or other approved ply wood flush shutters.
Supply and fixing of Oxidize door fitting.
Putty two coated including all Labour T&P etc complete.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Weather coat two coat coats------- Finishing walls with Acrylic Smooth exterior paint of required shade 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) sqm 90.00
Painting or Varnishing on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint or clear synthetic varnish including Supply of all materials labour and T&P etc. required for proper completion of the work. Paint to be used should confirm to the ISI no.103 1950 (In two coat.) wood work.
Fixing Panes of glass with equal or equivalent ISI marked quality putty Brads and springs and including supply of all materials and labour ete complete. (3.80 to 4.7mm thick)
fixing of aluminium sheet 24 gauge in door shutter with B & snew----Toilet
25mm(1½”) thick 1:2:4 plain cement concrete floor with cement, approved coarse sand and 2cm(3/4”) graded approved stone laid in panels finished with 3mm. (1/8”) flooring coat of neat cement or cement and marble dust in 5:1 as specified over removing and over lapping mortar at the joints of panel sand removing any and giving them a uniform finish including Supply of all labour and T&P etc. required for proper completion of the work.
Providing and injecting chemical for peri constructional Anti-termite and creating and chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling jun ction of wall and floor. Along the external per meter of binding expansion joints currounding of pipes and conduit etc. complete. (plinth area of the building at 6313 (part 2013) IMIDACLOPRID SC 30.5 concenterate or any othe approved material sush as Hepthachlor of Chlordane wall be used. The rate of application of chemical em'ulsion shall be as follows :- treatment of top surface of plinth filling 5 liters per sqm.
fixing of Jali door Shutter in teak wood
fixing of Stainless steel masqutio proof jali window.
fixing of ward rob shutter
fixing of Grenite Stone flooring and nosing window sil and courter
filling of Sinder in Sukan portion of toilet
fixing of M.S. Sheet door
laying “Brick bat Coba” 100 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water proofing compound filled gaps of coba & including supply of all materials labour T&P etc. required for proper completion of work and as per direction of E.I.C.
fixing 110mmø PVC pipe complete with rose heads bends M.S. Clamps 2.5cmX3mm fixed to walls by 15cm long 6mmø nail and including repair of plaster pointing etc if damaged during fixing of the pipes including cost of all material labour, tools and plant etc. required for proper completion of work.
Making Khurra
Moulding of Graynite stone
Supply of Labour for SEPTIC TANK FOR 25 USER
Excativion in foundation in mixed soil
filling of Sand
Lean Concrete in 1:4:8 in C:C/S:S/ballest (40mm)
R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast.
Brick work in 1:4 C:C/Sand mortar in sides
20mm Plaster with 1:2 C:C/S + neat cement
R.C.C. in 1:1½:3 C:C/S:S/G Top cover
Cutting & binding of for steel
40mm P.C.C. flooring in 1:2:4 C:C/S:S/G
12mm plaster outer side
Supply of Labour for SOAK PIT (Inner Dia 2.50mts)
Excavation in foundation insoil mixed with moram/kankar in bundelkhand area requiring use of specials tools and plants such as pick axes and sabbal etc. (Rate ins including Royality) (¶d2/h)
First Class bricks works in 1:4 cement and coarse sand of 1.25F.M. mortar in foundation upto plinth supply of all labour and T&P etc. required for proper completion of the work including providing scaffolding rope, chahlies fixing and removal. in foundation. (Honey Comb Brick Work with 1:4 C:Sand) (¶d2/h)
Filling of Brick Bats (¶/4) = 0.79
R.C.C. work with cement approved course sand and 2 cm (3/4)” gauge approved stone ballast in the proportions of 1:1½;3 in lintels of doors and windows excluding supply of reinforcement and its bending but including its fixing and bending the same with 24 B.W.G.G.I. Binding wire and including necessary centering and shuttering etc. and also including Supply of all labours and T&P etc. required for proper completion of work binding wire cost being including in the item but for Slab etc.
Mild steel or iron in plain work such as reinforced concrete or reinforced. for Slab.
Brick on edge
Supply and fixing 110mmø PVC pipe complete with rose heads bends M.S. Clamps 2.5cmX3mm fixed to walls by 15cm long 6mmø nail and including repair of plaster pointing etc if damaged during fixing of the pipes including cost of all material labour, tools and plant etc. required for proper completion of work.
2cm. (.3/4”) thick cement plaster in Dedo or skirting in 1:2 consisting of one part of cement and 2 part in panels, finished with 3mm. (1/8”) floating coat of neat cement or cement and marble dust in redio of 5:1 including Supply of all labour and T&P etc. required for proper completion of the work. (For dedo skirting)
15 mm thick plaster with cement mortar over brick work minimum thickness not to be less than 3/8”(10mm) thick including supply of all labour and T&P etc. required for proper completion of the work for proper completion of the work but with cement and approved coarse sand in 1:6 cement & fine sand of 1.25F.M. mortar. inside
Casting of Man Hole Chamber 600X600X750
Fixing Of P.V.C Pipe 150 mm Dia
Supply of Labour for Sanitary & Water Supply
fixing of European type white glazed earthen ware W.C. pan Indian approved 1st Quality ISI marked backlight seat cover and lit of C.P. brass hinges and rubber buffers.
fixing Ist Quality W.C. Orrisa pan white glazed earthen ware ISI marked WC pan size 580mm (Hindustan, Cera make) including supply of all materials, labour and T&P etc. required for proper completion of work.
fixing of Wash hand Basin size 550x400mm ISI marked basin (Hindustan, Cera, Parrywere make)
Laying of Stanless Steel Sink of size 600X450X200mm with drainges board
fixing of C.P. Brass towel rail 600mm size together with pair of C.P. brass brackets to fit towel rail.
fixing of 600X400mm beveled edge mirror of superior glass mounted on 6mm thick A.C. Sheet or plywood sheet and fixed to plastic sleeves with C.P. Brass screws and washers.
fixing of C.P. Soap dise.
fixing of PVC Tank 1000 lits.
fixing of Angle cock
fixing of 15mmø C.P. Short body Bib cock.
fixing of 100X75mm PVC Nahani Trap.
fixing of C.P.waste 32mmø
fixing of C.P.waste 40mmø
fixing of C.P. Jali 100mmø
fixing of C.I. Door Tee 100mmø
fixing of C.I. Door Tee 75mmø
fixing of C.I. Door bend 100mmø
fixing of C.I. Door bend 75mmø
Supply and fixing of M.S. Clamp.100mmø
Supply and fixing of M.S. Clamp.75mmø
Making lead Joint 100mmø
Making lead Joint 75mmø
fixing of C.I.Pipe ISI mark C.I.pipe 100mmø
fixing of C.I.Pipe ISI mark C.I.pipe 75mmø
fixing of G.I.pipe 15mmø
fixing of G.I.pipe 20mmø
fixing of G.I.pipe 25mmø
fixing of 15mm PVC Connection 45mm long.
fixing of Gate Valve.25mmø
fixing of Gate Valve. 15mmø
fixing of C.I. Collar 100mmø
fixing of C.I. Collar 75mmø
Cutting of Hole in R.C.C.
fixing of C.I. Plan bend 100mmø
fixing of C.I. Plan bend 75mmø
Supply of Labour for Construction of APRON DRAIN 250mm wide
Excavation in foundation insoil mixed with moram/kankar in bundelkhand area requiring use of specials tools and plants such as pick axes and sabbal etc. (Rate ins including Royality)
Supply and filling of Sand.
Cement concrete in 1:4:8 with cement, sand and (22.40-43)mm granite stone ballast (crusher broken) in foundation including supply of all materials, labours and T&P etc. required for proper completion of work.
First Class bricks works in 1:4 cement and course sand of 1.25F.M. mortar in above plinth supply of all materials, labour and T&P etc. required for proper completion of the work. But in super structure in 230mm wall including providing scaffolding rope, chahlies fixing and removal. In Super Structure.
25mm cement concrete flooring 1:2:4 ( 1 cement: 2 coarse sand:4 graded stone aggregate of size 12.5mm and below) by laid over concrete finished with floating coat of neat cement (base concrete to be paid separately) including fixing of glass strips. (Excluding cost of glass strips.)
2cm. (.3/4”) thick cement plaster in on Drain Side & Top in 1:2 consisting of one part of cement and 2 part in panels, finished with 3mm. (1/8”) floating coat of neat cement or cement and marble dust in redio of 5:1 including Supply of all materials labour and T&P etc. required for proper completion of the work.
Electric Work (Labour With Material)
Wring point for light with 1.5 Sq. mm FRLSH insulated multistrend single core copper conductor cable in PVC conduit with 1.5 Sq. mm FR PVC insuleted multistrend copper conductor cable as earthwire drawn inside Modular type switch & celling rose angle/ batten holder on 3mm thick phenolic paminated backlite sheet etc.complete in all respect.
Wring point for fan/fresh air fan (light duty exhaust fan) with 1.5 Sq. mmFRLSH insulated multistrend single core copper conductor cable in PVC conduit with 1.5 Sqmm FR PVC insuleted multistrend copper conductor cable as earthwire drawn inside Modular type switch & celling rose angle/batten holder on 3mm thick phenotic paminated backlite sheet etc. complete in all respect.
Wring point for plug with 1.5 Sq. mm FRPVC insulated multistrend single core copper conductor cable in PVC conduit with 1.5 Sq. mm FR PVC insuleted multistrend copper conductor cable as earthwire drawn inside Modular type switch & socket etc. complete in all respect.
Wring point for call Bell with 1.5 Sq. mm FRLSH insulated multistrend single core copper conductor cable in PVC conduit with 1.5 Sq. mm FR PVC insuleted multistrend copper conductor cable as earthwire drawn inside plano type switch & socket etc. complete in all respect.
Wring point for Exhaust Fan with 1.5 Sq. mm FRLSHinsulated multistrend copper conductor cable in PVC conduit with 1.5 Sq. mm FR PVC insuleted multistrend copper conductor cable as earthwire drawn inside 15A Modular plano type switch & Ceiling rose on 3mm thick backlite sheet complete in all respect.
S/F of hexagonal fan box with hexagonal side of approx 80mm in legnth fabricated from 16 SWG MS sheet incorporating 10 mm dia, MS round bar as per approved complete in all respect.
Supply & wiring of submains with two number 10 sq.mm PVC insulated single core copper conductor in 25mm dia heavy duty PVC conduit with 1 no. 6sq.mm FR PVC insulated multistrend single core copper conductor cable as earth continulty wire drawn inside the conduit complete in all respect.
Supply & wiring of submains with two number 6 sq.mm PVC insulated single core copper conductor in 25mm dia heavy duty PVC conduit with 1 no. 4 sq.mm FR PVC insulated multistrend single core copper conductor cable as earth continulty wire drawn inside the conduit complete in all respect.
Supply & wiring of submains with Four number 10 sq.mm PVC insulated single core copper conductor in 25mm dia heavy duty PVC conduit with 2 no. 6 sq.mm FR PVC insulated multistrend single core copper conductor cable as earth continulty wire drawn inside the conduit complete in all respect.
Supply & wiring of submains with two number 2.5 sq.mm PVC insulated single core copper conductor in 25mm dia heavy duty PVC conduit with 1 no. 1.5 sq.mm FR PVC insulated multistrend single core copper conductor cable as earth continulty wire drawn inside the conduit complete in all respect.
Supply and fixing of batten holder complete in all respect
Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
S/F of LED Tube light with Batten suitable for up to 1X22 Watt LED tube light complete including tube etc. On surface complete in all respect CAT-AA
S/Laying of 'Al' conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size of as directed by the Engineer - Incharge, complete in all respect. The armouring of the cable ahsll be properly connected with the earth conductor by clamps etc. 50 sq.mm 3.5 core.
Supply & burying of Earthing Electrode T-19 (Hot Dip Galvanized), Length 300mm, Outer pipe 50mm, inner pipe 25, Terminal dia 12mm, Outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip galvanization up to 100 micron filled with crystllingnce conductive mixture (CCM) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm squre C.I. frame with hinged cove & masonty housing. (From electrode terminal to switch board, cost of 25x3 G.I. strip will be extra) Make: As approved in U.P.P.W.D., & C.P.R.I. Certified.
S&L of 25mm x 3mm G.I. Strip from earth electrode directly in the ground as requird complete in all respect.
S/F of electronic fan regulator 120-280 V ISI marked ,on the existing switch board including making connections, required material, labour T/P etc. for proper completion of work to the satisfaction of Engineer in Charge of work.
S/F of 6Amp. To 32 amp. SPMCB (10 KA) Cat B
S/F of 63 amp DP MCB CAT- B
S/F of 40amp SPMCB CAT- B
S/F of 63 amp SPMCB CAT- B
S/F of 63 amp FP MCB CAT- B
S&F surface/flush mounting 8 ways SPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. Cat-B
S & F surface/Flush mounting 4ways V TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. CAT -B
S&F surface/flush mounting 4 ways SPN distribution board without MCB complete in all respect, as directed at site by Engineer in charge. Cat -A
S&F of Power plug with 20A/250 volt flush type switch and 5 pin 20A/250V flush type universal socket in suitable MS box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer.
Supply of Erection of Ceiling fan 1200 mm ISI mark. Sweep, 230/250 Volts, 50 Hz standared down rod, bleads including connection etc. complete as required.
S/F of Light duty Exhaust Fan 300mm
Supply and fixing of M.S. Drum Dully painted with luvers making hole in wall for exhaust fan complete.
S/F of LED Bulb 9 Watt
Supply and fixing of Call bell
S/F fan sheet cover of backelite sheet
Supply & wiring of submains with two number 1.5 sqmm PVC insulated 1100 V grade Multistrand single core copper conductor in 20mm dia heavy duty PVC conduit with 1 no. 1.5sqmm FR PVC insulated multistrend single core drawn inside the conduit complete in all respect.
S/F OF exhaust fan lovers 12"
M/S HARSHITA ASSOCIATE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .