Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC NO 1 4 56 Y SRI BHARATHI NAGAR OPP PARVATHI THEATER CUMBUM ROAD THENKARAI PERIYAKULAM THENI DT 625 601 | PERIYAKULAM | THENI | TAMIL NADU | 625601 | L1 | Accepted-AOC AOC | |
| 2 | L2₹21.6 L+₹1.5 L (7.20%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹28.2 L+₹8.1 L (40.1%)Rejected-Finance | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹28.3 L+₹8.1 L (40.4%)Rejected-Finance NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L4 | Rejected-Finance NOT L1 | |
| 5 | L5₹28.4 L+₹8.3 L (41.1%)Rejected-Finance | L5 | Rejected-Finance NOT L1 |
| Sl No | Description | Qty | Unit | GS TRADERS L6 | RAMSON TRADERS L5 | Shiva Shakthi Electrical Enterprises L4 | SREE VARU ELECTRICALS L3 | PRIYADARSHINI CONSTRUCTIONS L1 | Auromirra Enterprises L2 | KAALIKA ELEVATORS L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing unserviceable materials and making good disturbed surfaces of walls, floors etc. | 691 | Point | 20 ₹13,820 | 20 ₹13,820 | 9 ₹6,219 Lowest | 25 ₹17,275 | 10 ₹6,910 | 10 ₹6,910 | 110 ₹76,010 |
| 2.00 | M & L for point wiring with 1100 Volts grade 1.5 sqmm PVC insulated FRLSH unsheated cable with multistandred copper conductor conforming to IS: 694:1990 (for phase, Neutral and and Earth) in and including Non metalic PVC rigid condiut medium grade ISI mark with all accessories concealed in wall/ ceiling/floor / road etc, with cast iron / pressed steel terminal box of sutaible size duly painted inner & outside by anticorrosive paint, including plastic laminated sheet 1.6 mm thick for mounting switches, socket cover with fitting screw washer, including cutting chasses in wall/floor/roof for fixing of conduit and making good the distributed surfaces using cement plaster, levelling with existing surface complete all as specified and as directed for following-
One light/ fan/ bell point controlled by one switch | 25 | Point | 600 ₹15,000 | 800 ₹20,000 | 600 ₹15,000 | 600 ₹15,000 | 650 ₹16,250 | 575 ₹14,375 Lowest | 730 ₹18,250 |
| 2.01 | M & L for One Light/ Fan point on same switch circuit board with other switches complete all as specified and directed by Engr-In-Charge | 100 | Point | 450 ₹45,000 | 100 ₹10,000 Lowest | 450 ₹45,000 | 300 ₹30,000 | 450 ₹45,000 | 125 ₹12,500 | 340 ₹34,000 |
| 2.02 | M & L 5 Amp socket outlet point on same board complete all as specified and directed by Engr-In-Charge | 10 | Point | 100 ₹1,000 | 100 ₹1,000 | 50 ₹500 Lowest | 90 ₹900 | 100 ₹1,000 | 70 ₹700 | 230 ₹2,300 |
| 2.03 | M & L 5 Amp socket outlet point independent but near switch board complete all as specified and directed by Engr-In-Charge | 15 | Point | 300 ₹4,500 | 800 ₹12,000 | 600 ₹9,000 | 600 ₹9,000 | 450 ₹6,750 | 75 ₹1,125 Lowest | 810 ₹12,150 |
| 2.04 | One light point controlled by two way switch complete all as specified and directed by Engr-In-Charge | 6 | point | 700 ₹4,200 | 880 ₹5,280 | 666 ₹3,996 | 650 ₹3,900 | 750 ₹4,500 | 600 ₹3,600 Lowest | 1,120 ₹6,720 |
| 2.05 | All as per Item no 2 above here in before but with 2.5 sqmm size wire for power point concealed in wall complete all as specified and directed by Engr-In-Charge | 15 | Point | 800 ₹12,000 | 880 ₹13,200 | 801 ₹12,015 | 750 ₹11,250 Lowest | 750 ₹11,250 Lowest | 775 ₹11,625 | 750 ₹11,250 Lowest |
| 3.00 | M & L for point wiring with 1100 Volts grade 1.5 sqmm PVC insulated FRLSH unsheated cable with multistandred copper conductor conforming to IS: 694:1990 (for Phase, Neutral and and Earth) in and including Non metalic PVC rigid condiut medium grade with ISI mark of appropriate size with all accessories concealed in wall/ ceiling/floor etc, with GI flush in box/terminal boxes of sutaible size, including front plate for mounting of modular switch/ socket and combined cover plate with fitting screw washer, including cutting chasses in wall/floor/roof for fixing of conduit and flush in box and making good the distributed surfaces matching with existing complete all as specified and as directed for following-
One light/ fan/bell/ point controlled by one switch | 50 | Point | 625 ₹31,250 | 800 ₹40,000 | 600 ₹30,000 | 600 ₹30,000 | 650 ₹32,500 | 585 ₹29,250 Lowest | 1,160 ₹58,000 |
| 3.01 | M & L for One Light/ Fan point on same switch circuit board with other switches complete all as specified and directed by Engr-In-Charge | 60 | Point | 500 ₹30,000 | 150 ₹9,000 | 450 ₹27,000 | 300 ₹18,000 | 450 ₹27,000 | 125 ₹7,500 Lowest | 510 ₹30,600 |
| 3.02 | All as per Item No 3 above here in before but for Modular type Socket 6/10 Amp of two module in independent board, 230 volts complete all as specified and directed by Engr-In-Charge. Make: | 15 | Point | 625 ₹9,375 | 800 ₹12,000 | 600 ₹9,000 Lowest | 600 ₹9,000 Lowest | 650 ₹9,750 | 605 ₹9,075 | 1,030 ₹15,450 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Jul 2025, 6:00 pmClosed
GE(S)BANGALORE
GE(S)BANGALORE
REPAIR/MAINT OF INTERNAL WIRING SWITCHES, SOCKETS,SUB MAIN,LIGHTING AND CONNECTED ITEMS AT CWE OFFICE,GE (S),MES IB, BSO YARD,AGE E/M YARD, DHOBHI GHAT, MARSHAL BK, ZRO, TORNAGALLU AND REPAIR MAINT TO FANS,GEYSERS AND COOLING APPLIANCES UNDERGE(S)BLR
2025_MES_716695_1
8938/E8
Open Tender
Civil Works
Item Rate
270 days
BANGALORE
AS PER NIT
6 documents required · 6 mandatory
₹500
GE(S)BANGALORE
₹80,000
Yes
11 Oct 2025
25 Jun 2025
26 Jul 2025
25 Jun 2025
24 Jul 2025
10 Jul 2025
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing unserviceable materials and making good disturbed surfaces of walls, floors etc.
M & L for point wiring with 1100 Volts grade 1.5 sqmm PVC insulated FRLSH unsheated cable with multistandred copper conductor conforming to IS: 694:1990 (for phase, Neutral and and Earth) in and including Non metalic PVC rigid condiut medium grade ISI mark with all accessories concealed in wall/ ceiling/floor / road etc, with cast iron / pressed steel terminal box of sutaible size duly painted inner & outside by anticorrosive paint, including plastic laminated sheet 1.6 mm thick for mounting switches, socket cover with fitting screw washer, including cutting chasses in wall/floor/roof for fixing of conduit and making good the distributed surfaces using cement plaster, levelling with existing surface complete all as specified and as directed for following- One light/ fan/ bell point controlled by one switch
M & L for One Light/ Fan point on same switch circuit board with other switches complete all as specified and directed by Engr-In-Charge
M & L 5 Amp socket outlet point on same board complete all as specified and directed by Engr-In-Charge
M & L 5 Amp socket outlet point independent but near switch board complete all as specified and directed by Engr-In-Charge
One light point controlled by two way switch complete all as specified and directed by Engr-In-Charge
All as per Item no 2 above here in before but with 2.5 sqmm size wire for power point concealed in wall complete all as specified and directed by Engr-In-Charge
M & L for point wiring with 1100 Volts grade 1.5 sqmm PVC insulated FRLSH unsheated cable with multistandred copper conductor conforming to IS: 694:1990 (for Phase, Neutral and and Earth) in and including Non metalic PVC rigid condiut medium grade with ISI mark of appropriate size with all accessories concealed in wall/ ceiling/floor etc, with GI flush in box/terminal boxes of sutaible size, including front plate for mounting of modular switch/ socket and combined cover plate with fitting screw washer, including cutting chasses in wall/floor/roof for fixing of conduit and flush in box and making good the distributed surfaces matching with existing complete all as specified and as directed for following- One light/ fan/bell/ point controlled by one switch
M & L for One Light/ Fan point on same switch circuit board with other switches complete all as specified and directed by Engr-In-Charge
All as per Item No 3 above here in before but for Modular type Socket 6/10 Amp of two module in independent board, 230 volts complete all as specified and directed by Engr-In-Charge. Make:
All as per Item No 3 above here in before but for Modular type Socket 6/10 Amp of two module on same board, 230 volts complete all as specified and directed by Engr-In-Charge.
All as per Item no 3 above here in before but for Modular type socket 16A of Two Module but with size 2.5 sqmm wire for power point concealed in wall complete all as specified and directed by Engr-In-Charge
M & L for point wiring with 1100 Volts grade 1.5 sqmm PVC insulated FRLSH unsheated cable with multistandred copper conductor conforming to IS: 694:1990 (for phase, Neutral and and Earth) in Existing condiut all accessories concealed in wall/ ceiling/floor / road etc, with cast iron / pressed steel terminal box of sutaible size duly painted inner & outside by anticorrosive paint, including plastic laminated sheet 1.6 mm thick for mounting switches, socket cover with fitting screw washer, including cutting chasses in wall/floor/roof for fixing of conduit and making good the distributed surfaces matching with existing complete all as and as directed for following- One light/ fan/bell point controlled by one switch
M & L One Light/ Fan point as same switch circuit board with other switches complete all as specified and directed by Engr-In-Charge
M & L 5 Amp socket outlet point on same board complete all as specified and directed by Engr-In-Charge
M & L 5 Amp socket outlet point independent but near switch board complete all as specified and directed by Engr-In-Charge
All as per Item no 4 above here in before but with 2.5 sqmm size wire for power point in existing conduit complete all as specified and directed by Engr-In-Charge
M & L for point wiring with 1100 Volts grade 1.5 sqmm PVC insulated FRLSH unsheated cable with multistandred copper conductor conforming to IS: 694:1990 (for phase, Neutral and and Earth) in casing caping medium grade with all accessories, including cast iron / pressed steel terminal box of sutaible size duly painted inner & outside by anticorrosive paint, including plastic laminated sheet 1.6 mm thick for mounting switches, socket cover with fitting screw washer, including cutting chasses in wall for fixing of terminal boxes for mounting switch/sockets and making good the distributed surfaces using cement plaster, levelling to match with existing surface complete all as and as directed for following- One light/ fan/bell point controlled by one switch
M & L One Light/ Fan point as same switch circuit board with other switches complete all as specified and directed by Engr-In-Charge
M & L 5 Amp socket outlet point on same board complete all as specified and directed by Engr-In-Charge
M & L 5 Amp socket outlet point independent switch board complete all as specified and directed by Engr-In-Charge
All as per Item no 5 here in before but with cable 2.5 sqmm wire for power point in casing caping medium grade of appropriate size complete all as specified and directed by Engr-In-Charge
S&F for switch piano, flush type single pole, one way 5 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge.
S&F for switch piano, flush type single pole, two way 16 Amps, 230 Volts complete all as specified and directed by Engr-In-Charge.
M&L for switch socket outlet 2 in1, 5pin, 5Amp with mounting arrengement on two/ four holes complete all as specified and as directed by Engr-in-charge.
M&L for switch socket outlet 2in1, 6pin, 5/15Amp multipurpose with mounting arrengement on two/ four holes complete all as specified and as directed by Engr-in-charge .
S&F for Modular type switch one way 6/10 Amps, 230 volts matching with existing complete all as specified and directed by Engr-In-Charge.
S&F for Modular type switch one way 16 Amps, 230 volts, matching with existing complete all as specified and directed by Engr-In-Charge.
S&F for Modular type Socket 6/10 Amps, 230 volts matching with existing complete all as specified and directed by Engr-In-Charge.
S&F for Modular type Socket 16 Amps, 230 volts, matching with existing complete all as specified and directed by Engr-In-Charge.
S&F for Modular type fan regulator 1/2 module as reqd matching with existing, 230 volts complete all as specified and directed by Engr-In-Charge.
S & F stepped type electronic fan regulator flush type complete all as specified and as directed by Engr-In-Charge.
S&F for Modular type bell push switch one way 6/10 Amps, 230 volts matching with existing complete all as specified and directed by Engr-In-Charge.
S&F Bell push piano type, 5 Amps complete all as specified and directed by Engr-In-Charge.
S&F for Ceiling rose surface mounted with three terminals, PVC/Polycarbonate isolated body complee all as specified and directed by Engr-in-Charge.
S&F Call bell AC, 230 Volts matching with existing sample complete all as specified and directed by Engr-In-Charge.
S&F in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20/32 Amps as reqd all as specified and directed .
S&F MCB, DB Double door type, made out of CRCA mild steel sheet flushed in wall, SPN 4 way with 200 Amps rated bus bar , 240 volts IP-43, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc including taking down old DB complete all as specified and as directed.
All as per item No 21above here in before but for SPN 8 Way DB complete all as specified and directed by Engr-In-Charge.
All as per item No 21 above here in before but for TPN 4 way DB 415 Volts complete all as specified and directed by Engr-In-Charge.
S & F in replacement VTPN DB - Dobule Door made out of CRCA mild steel sheet flushed in wall, TPN 4 way with 200 Amp rated bus bar, 415 volt with PVC MCB blanking plate, stove enamelled for incorporated of MCBs, insulators and MCCB of capacity upto 125 Amps TP/FP etc, complete all as specified and as directed by engineer in charge.
Supply and fixing in replacement of MCB TPN 415 Volt 63 Amps Complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of MCB SPN 6 - 40 Amps, 240 Volts Complete all as specified and as directed by Engr-in-Charge.
Supply & fixing in replacement of MCB SP 06-40 Amp, AC, 240 volts, Complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB FP 415 Volts 125Amps, 16 KA Complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB FP 415 Volts 100Amps, 16 KA Complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB FP 415 Volts 63 Amps, 16 KA Complete all as specified and as directed by Engr-in-Charge.
Supply and Fixing of Bus bar Chamber indoor type with aluminium bus bar 100Amp TPN, with four outgoing ways fabricated out of sheet steel, duly painted with stove enamelled paint over a coat of red oxide with locking arrangement and mounting arrangement flush in wall/fixed in wall as reqd including taking down old bus bar chamber complete all as specified and as directed by engr in charge.
S&F in replacement of 5 Amp switch socket with junction box complete all as specified and as directed by Engr-In-Charge.
S&F in replacement of 15 Amp switch socket with junction box complete all as specified and as directed by Engr-In-Charge.
S&F in replacement PVC insulated FRLS unsheathed multistranded copper cable1.5 sqmm complete all as specified and as directed by Engr-In-Charge.
S&F in replacement PVC insulated FRLS unsheathed multistranded copper cable 2.5 sqmm complete all as specified and as directed by Engr-In-Charge.
S&F in replacement PVC insulated FRLS unsheathed multistranded copper cable 4.0 sqmm complete all as specified and as directed by Engr-In-Charge.
S&F in replacement PVC insulated multistranded flexible 3 core copper wire 1.5 sqmm complete all as specified and as directed by Engr-In-Charge.
S&F in replacement PVC insulated aluminium stranded conductor cable 2 core 6 sqmm complete all as specified and as directed by Engr-In-Charge.
S&F in replacement PVC insulated aluminium stranded conductor cable 2 core 10 sqmm complete all as specified and as directed by Engr-In-Charge.
Supply and Fixing in replacement of PVC Casing caping of size 18 mm x 8 mm with clips locking, complete all as specified and as directed by Engr-In-Charge.
Supply and Fixing in replacement of PVC Casing caping of size 20 mm x 12 mm with clips locking, complete all as specified and as directed by Engr-In-Charge.
S&F in replacement of flush metal GI Box for Modular type switch and sockets flush in wall including cutting chasses to wall for fixing of box and making good to disturbed surface suitable for mounting 4 nos switch one module complete all as specfied and directed by Eng-In-Charge.
S&F in replacement of modular switch and socket mounting/cover plate with frame suitable for 4 module metal GI Box for modular type switches and sockets complete all as specified and directed by Engr-In-Charge.
S&F in replacement of flush metal GI Box for Modular type switch and sockets flush in wall including cutting chasses to wall for fixing of box and making good to disturbed surface suitable for mounting 6 nos switch one module complete all as specfied and directed by Eng-In-Charge.
S&F in replacement of modular switch and socket mounting/cover plate with frame suitable for 6 module metal GI Box for modular type switches and sockets complete all as specified and directed by Engr-In-Charge.
S&F in replacement pole mounted light fitting for outdoor use Post top laltern/Garden Light with aluminum die cast base suitable for mounting on 40mm dia pole/pipe and polycarbonate white diffuser suitable for and including 9W LED lamp with B22 base of color as decided including B22 lamp holder complete all as specified and directed by Engr-In-Charge.
S&F in replacement of surface mounted Mirror light LED batten 2 feet 10 W with all accessories as required flexible copper 2 core wire from fitting to ceiling rose complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of surface & wall mounted LED batten 4 feet 20 W including flexible copper 2 core wire from tube light fitting to ceiling rose required length with all accessories all specified and as directed by Engr-in-Charge.
S&F in replacement LED weather proof bulk head light fitting of shape and size as per site requirment of wattage upto 10 watt matching with existing unserviceable light fitting with mounting clamp, LED driver holder, LED lamps etc including connecting up to in celling rose complete all as specified and as directed by Engr-in-Charge.
S&F in replacement LED downlighter light fitting of shape and size as per site requirment of wattage 15 to 20 watt matching with existing unserviceable light fitting with mounting clamp, LED driver holder, LED lamps etc including connecting up to in celling rose complete all as specified and as directed by Engr-in-Charge.
S&F in replacement LED recess/surface mounting as reqd 2x2 fittings 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with deffuser glare free light complete with driver, holders & LED lamp of colour as decided suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as derected by Engr-in-Charge
S&F in replacement building protection light fitting to be mounted on pole/bracket of minimum 35W, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, corrosion resistant including optics for scattering light complete all as specified and directed by Engr-In-Charge.
S&F in replacment of 36 Watt LED recess/surface mounted 1'x4' panel light with electronic driver of operating voltage 110 to 265 Volts complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable of 24/0.2mm size and taking down old unserviceable tube light fitting complete all as specified and as directed by Engr-In-Charge.
S&F in replacement LED inverter batten tube light fitting 4 ft 20 watts complete all as specified and as directed by Engr-In-Charge.
S & F in replacement LED Strip Light fitting of 10 watt including driver colour as desided at site complete all as specified and as directed by Engr-In-Charge.
S&F in replacement wall mounting light fitting in plastic body with lamp holder fancy B22 base and diffiuser sutaible for and including 9w LED Lamp of colour as decided with mounting provision complete all as secified as directed by Engr-in-Charge.
Supply, laying, testing and commissioning of LT under ground cable XLPE in repair insulated armoured, heavy duty, elelctric cable, size 10 Sqmm 2 Core with stranded aluminium conductor, 1100 Volts grade conforming to IS -7098 (Part-I) 1988 fixed with saddle and clamps complete with cable ends connection with proper thimbles nut bolts washer including taking down of existing cables Complete all as specified and as directed by Engr-In-Charge.
All as per item No.57 but of size 16 Sqmm x 4 core
M&L for preparation of surfaces for painting of Metallic Meter box/ Bus bar chamber of any size, with two coats of stove enamelled Paint of color as decided over a coat of red oxide primer both inside and outside of door complete complete all as specifed and as directed by Engr-In-Charge.
M&L sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through concealed/ casing caping/ PVC conduit as required at site including taking down old sub main complete all as specified and as directed by Engr-In-Charge. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
M&L sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through concealed/ casing caping/ PVC conduit as required at site including taking down old sub main complete all as specified and as directed by Engr-In-Charge. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
S & F LED flood light 30W made up of pressure die cast aluminium housing wth toughened glass and LEDs as a light source prewired with electronic driver suitable for 30 watts light fitting with IP 65 protection with Surge protection device for protection of LED driver, lumen efficacy of light fitting shall be not less than 100 lm/W. with necessary mounting arrangements colour as per deside at site including taking down old unserviceable light fitting.complete all as specified and directed by Engr-in-charge.
S & F LED Land Scape not less than 8W made up of pressure die cast aluminium housing and LEDs as a light source prewired with electronic driver suitable for 8 watts light fitting with IP 65 protection with Surge protection device for protection of LED driver, lumen efficacy of light fitting shall be not less than 100 lm/W. with pole of height upto 1 mtr including mounting arrangements on floor/ Earth using PCC of appropriate ration as required including taking down old unserviceable light fitting.complete all as specified and directed by Engr-in-charge.
M & L earthing complete with GI earth plate Electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished earth wire 4.0 mm dia by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC chamber and RCC cover slab, connecting lead wire from test point to DB complete all as specified & as directed by Engr-In-Charge.
Taking down, dismantling of geysers of any type/capacity from site for repair and Inspection, cleaning, descaling, brazing inner tank, internal wiring including replacement of unserviceable items as reqd, reassembling & reinstallation after necessary repair incuding testing after repair complete all as specified & directed. Note :(a) Replacement of major unserviceable items shall be measured & paid separately under respective item of work.. (b)Cost of replacement for minor items like washers, gaskets, nuts, bolts etc and items not mentioned below is deemed to be include in quoted rates.
Supply only following items to be fixed under item no 61 complete all as specified and directed by Engr-In-Charge. Inner tank for geyser of capacity 25 ltrs of shape matching with existing.
Inner tank for geyser of capacity 50 ltrs of shape matching with existing.
Siphon Assembly suitable for geyser of capacity 25 ltrs of shape matching with existing.
Siphon Assembly suitable for geyser of capacity 50 ltrs of shape matching with existing.
Heating element rated 1.5/2.0 KW with mounting provisions round/tikona as reqd of shape matching with existing
Thermostat with auto cutoff provision switch capillary/screw type, with range 0-80 deg celcius of shape and size matching with existing suitable for geyser of capacity 25/50 Ltrs.
Indicator lamp red and green with coloured diffuser for geysers matching with existing.
Safety valve/high pressure valve matching with existing for geysers
NRV for geysers matching with existing.
Base fixing cover matching with existing.
Cover outer for geyser of capacity 25/50 ltrs of shape and size matching with existing.
Thermal Insulation material for isolation of geyser tank and outer cover, complete set for 25/50 ltrs capacity geyser.
PVC insulated Copper cable flexible 3 core of size 2.5 Sqmm ISI marked.
15 Amps Plug Top 3 Pin
PVC connection flexible pipe 16mm dia 450mm long with brass ferrules at both ends for hot and cold water all as specified & as directed. (Set of 2)
Taking down unserviceable ceiling fan, wall mounted fan, cabin fan, exhaust fans etc of any type and size from position, disconnecting electric supply, repair/replacement of unserviceable items, including cleaning oiling/greasing,tightening of nut bolts refixing blades complete all as specified and directed by Engr-In-Charge. Note: (a) Cost of Replacement of minor items i.e, nut bolts, screws, pins etc including T&P and grease/oil are deemed to be included in quoted rates. Major items to be replaced to make fans serviceable will be measured and paid seperately.
Supply only following items to be fixed under item no -3 complete all as specified and directed by Engr-In-Charge. Ball/Roller bearing of size and shape matching with existing suitable for fans
Gun metal bush of size and shape matching with existing suitable for fans
Motor stator for ceiling fans wounded with copper wire of size matching with existing with insulation with casing complete.
Motor stator for exhaust fans upto 300 mm sweep wounded with copper wire of size matching with existing with insulation and casing matching with existing complete.
Motor stator for wall mounted fans upto 450 mm sweep wounded with copper wire of size matching with exsting with insulation and casing matching with existing complete.
Motor rotor prewired for ceiling fans of size and type matching with existing
Motor rotor prewired for Exhaust fans/wall mounted fans of size and type matching with existing
Fan blades for ceiling fan of any type and size matching with existing
Fan blade for exhaust fan metal body any type and size with mounting provisions matching with existing.
Plastic cup with screw for ceiling fans
Rubber bush with MS bolts, nuts & washers with 'U' clamps for ceiling fans complete all as specified and as directed.
S&F in replacement capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed.
S&F in replacement capacitor 3.15/4.0 Mfd suitable for ceiling / exhaust/wall mounting fans complete all as specified and as directed.
S&F in replacement down rod of 30/45 cm with nut, bolts and safety pin for ceiling fans complete all as specified and as directed.
M&L for cutting,grinding , welding of exsiting steel/Wooden window frame/grill , removal of wire mesh and glass panel and fixing 10mm thick ply wood for fixing of PVC exhaust fan fixing arrangement including making good to distrubed surfaces matching with existing complete all as specified and directed .
M&L for making hole in stone masonary/Hollow cubes/bricks wall using suitable T&P for fixing of metal body exhaust fan suitable size and making good the distrubed surfaces matching with existing colour complete all as specified and as directed .
M&L for making hole in stone masonary/Hollow cubes/bricks wall at both ends (2 holes) using suitable T&P for hanging of GI Pipe of upto 40mm dia in wall for fixing of ceiling fan and making good the distrubed surfaces matching with existing complete all as specified and as directed .
Supply and fixing GI Pipe 40mm dia medium grade, fixed on wall for mounting of ceiling fans complete all as specified and directed by Engr-In-Charge.
M&L for Preparation of surface & painting the outer body of geyser complete after cleaning & applying one coat of stove enamelled white paint by spray painting, writing No incluing taking down and refixing after painting complete all as specified & as directed by Engr -in-Charge.
M&L for Preparation of surface & painting the ceiling fans with blades complete after cleaning & applying one coat of stove enamelled white paint by spray painting, writing No complete all as specified & as directed by Engr -in-Charge.
M&L for Preparation of surface & painting the Exaust fans with blades complete after cleaning & applying one coat of stove enamelled white paint by spray painting, writing No complete all as specified & as directed by Engr -in-Charge.
Dismantling /opening the ceiling fan of any type size and make, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling/re-fixing in its p complete all as specified and as directed by engr in charge..
Dismantling /opening the air circulator fans of upto 750 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Dismantling /opening the wall mounted fan of upto 450 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Dismantling /opening the exhaust fans upto 300mm sweep of any type size removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
S&F in replacement ceiling fan motor of 1200 mm sweep complete with rotor, stator, outer body including 3 nos fan blades, down rod and other connected accessories matching with existing complete all as specified and as directed by Engr- in- Charge.
S&F in replacement Exaust fan motor of up to 250 mm sweep as required at site plastic body complete with rotor, stator, outer body, blades, louver and other connected accessories including mounting frame matching with existing complete all as specified and as directed by Engr- in- Charge.
S&F in replacement Exaust fan motor of 300 mm sweep metal body complete with rotor, stator, outer body, blades, louver and other connected accessories including mounting frame matching with existing complete all as specified and as directed by Engr- in- Charge.
S&F in replacement wall mounted fan motor of 400 mm sweep plastic body complete with rotor, stator, outer body, blades, front and rear grills, fan regulator, swing system and other connected accessories including mounting provisions matching with existing complete all as specified and as directed by Engr- in- Charge.
S&F in replacement storage type electric heater tank 25 Ltr with thermostat, siphon assly, heating element, mineral wool insulation, outer body/cover, red and green indicatior, safety valve, NRV complete with flexible 3 core PVC insulated cable with mounting provisions complete all as specified and directed by Engr-In-Charge.
M&L in replacement for extension of down rod for ceiling fan upto 1.5 mtr including nut, bolts , washers complete accessories all as specified and as directed.
S&F in replacement of exhaust fans outerframe for holding exhaust fan motor upto 280 mm sweep with supporting angle complete all as specified and directed.
S&F in replacement of exhaust fans outerframe for holding exhaust fan motor 300 mm sweep with supporting angle complete all as specified and directed.
M&L in replacement for louver with iron frame and aluminum shutter/blades suitable for exhaust fans of upto 450mm sweep complete with accessories and mounting provisions complete all as specified and directed by Engr-In-Charge.
Auromirra Enterprises (BID ID -3361754)
SREE VARU ELECTRICALS (BID ID -3362254)
Shiva Shakthi Electrical Enterprises (BID ID -3362005)
RAMSON TRADERS (BID ID -3361688)
GS TRADERS (BID ID -3355444)
KAALIKA ELEVATORS (BID ID -3362114)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .