| 1 | L1₹2.9 CrAdmitted-Finance | ₹2.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.9 Cr+₹1.9 L (0.66%)Admitted-Finance | ₹2.9 Cr+₹1.9 L (0.66%) | L2 | Admitted-Finance |
| 3 | L3₹3.0 Cr+₹11.9 L (4.12%)Admitted-Finance 248 1 CHHEDIPURWA STATION ROAD BEHIND GURU NANAK SCHOOL GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | ₹3.0 Cr+₹11.9 L (4.12%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | KRIPA ELECTRICAL WORKS AND SUPPLIER L2 | M/s Aghoreshwar Kripa Construction Co. L1 | M/S SMM INFRATECH PVT Ltd L3 |
|---|---|---|---|---|---|---|
| 1.00 | SUPPLY OF Following MATERIALS as per Resspo Drawing/ Norms. | - | - | - | - | - |
| 2.00 | Main Bus Bar complete with structure with Panther conductor , Disc & Fitting(A-type steel structure) | 1 | Set | 1,10,000 ₹1,10,000 Lowest | 1,85,000 ₹1,85,000 | 1,50,000 ₹1,50,000 |
| 3.00 | Structure for 33 kV Lightning Arrester. | 15 | No. | 5,500 ₹82,500 | 100 ₹1,500 Lowest | 4,500 ₹67,500 |
| 4.00 | Structure for 33 kV Single PT | 3 | No. | 16,500 ₹49,500 Lowest | 26,500 ₹79,500 | 44,500 ₹1,33,500 |
| 5.00 | P.G. clamp for Panther to Dog conductor | 54 | No. | 200 ₹10,800 Lowest | 350 ₹18,900 | 250 ₹13,500 |
| 6.00 | P.G. clamp for dog conductor | 72 | No. | 85 ₹6,120 | 25 ₹1,800 Lowest | 120 ₹8,640 |
| 7.00 | 33 KV XLPE cable 3x300 sqmm | 160 | mtr | 3,750 ₹6,00,000 Lowest | 4,250 ₹6,80,000 | 3,750 ₹6,00,000 Lowest |
| 8.00 | 33 KV 3x300 sqmm Cable Jointing Kit | 8 | No. | 9,500 ₹76,000 | 6,500 ₹52,000 Lowest | 12,500 ₹1,00,000 |
| 9.00 | STP POLE 11 MTR | 4 | No. | 24,500 ₹98,000 Lowest | 25,000 ₹1,00,000 | 26,500 ₹1,06,000 |
| 10.00 | EARTHING COMPLETE WITH EARTHING ROD | 8 | No. | 1,250 ₹10,000 | 1,600 ₹12,800 | 950 ₹7,600 Lowest |
Tender Value
Refer Docs
EMD Value
₹2.9 L
Closing Date
10 Jul 2025, 4:00 pmClosed
SE EDC Mau 275101
SE EDC Mau 275101
Estimate for Construction of 2x5 MVA 33/11 KV SS Chaudhari Charan Singh Pump Canal Doharighat Mau on Turnkey Basis
2025_PVVNV_1053694_1
13/EDC(M)/2025-26
Open Tender
Electrical Works
Turn-key
120 days
EDD-Ghosi
Please refer To Tender documents
2 documents required · 2 mandatory
₹5,900
EE ETD Mau
₹2.9 L
7 Aug 2025
3 Jul 2025
11 Jul 2025
3 Jul 2025
10 Jul 2025
3 Jul 2025
Amount
SUPPLY OF Following MATERIALS as per Resspo Drawing/ Norms.
Main Bus Bar complete with structure with Panther conductor , Disc & Fitting(A-type steel structure)
Structure for 33 kV Lightning Arrester.
Structure for 33 kV Single PT
P.G. clamp for Panther to Dog conductor
P.G. clamp for dog conductor
33 KV XLPE cable 3x300 sqmm
33 KV 3x300 sqmm Cable Jointing Kit
STP POLE 11 MTR
EARTHING COMPLETE WITH EARTHING ROD
33 KV STAY SET COMPLETE
ACSR DOG CONDUCTOR
33 kv Polymer Pin insulator
33KV Disc Insulator Polymer Type
33 kv Disc fitting
Top channel M.S. 125x65x3200 mm
Droper Channel M.S. 100x50x2600 mm
MS Base Angle 75x75x6x2008mm With clamp & nut bolt
Number plate
Danger board with clamp
Barbed wire
Aluminium tape
Clamp with bolt & nut for Top dropper
6" Dia GI pipe 3 mtr. for 33 Kv cable protection
33 KV Line Isolator 400 Amp.
33 KV Bus Isolator 400 Amp.
Structure for 33 Kv line Isolator & bus isolator
33 KV Post Insulator
Structure for 33 KV POST INSULATOR
33KV Lightning Arrestor
P.T. 33 KV 1 Ph/110 V
33/11 KV Power T/F 05 MVA
33 KV VCB 800A, 750 MVA
33 KV SINGLE T/F Control Pannel
33 KV DOUBLE T/F Control Pannel
33KV CT 200/100/1A
33 KV C.T. structure complete as per resspo norms
11 KV Incoming VCB 600/300/5A
11 KV Outgoing VCB 200/100/5A
11 KV Bus Coupler
LT XLPE Cable 3.5x150 mm²
11 KV XLPE Cable 3x300 mm²
33 KV fuse set complete set
Structure for 33 kv Fuse Set
11KV XLPE Cable (300 Sq.mm.) Heat Shrinkable Jointing kit boxes mounted with switchgears and transformers. ( indoor/outdoor type )
11 KV jointing kit outdoor/indoor 3x300 sqmm
24 Volt(12 voltx2) battery & Invertor with cabinet
Copper Control Cable 4x2.5 mm²
Copper Control Cable 2x2.5 mm²
250 KVA 11/.4 KV T/F
Rubber Mat
Sub-station Name & Arrow shine Board complete(1.5*1.5 mtr. Iron sheet with stand)
05 Kg. CO₂ fire extinguisher portable type
05 Kg. dry powder fire extinguisher portable type
Fire buckets (4 No.) with stand filled with dry sand
LT XLPE CABLE 3.5X400 sqmm
Earthing of complete Indoor equipement (GI earthing both side and required MS strip 40*6 mm, 20 mtr each including 32 mm MS Bars)
EARTHING OF S/S Outdoor equipement and complete switchyard (22x16 Mtr) Earthmat work.
Power Transformer Delta neutral Earthing and Body Earthing including neutral support structure.(GI pipe) of length 20 mtr each.
outdoor switchyard & approach road with 70w l.e.d light 7 set including with 9meter stp& 4x16sqmm cable
chemical pipe earthing (lenth3meter dia80mm) with strip
ACDB box for distribution of LT line at panels and other equipment
G.I strip 50x6 mm
G.I strip 25x6 mm
Cartage, Erection, Feeting, Grouting and Laying of following fabricated structures as per Resspo Drawing/ Norms as per instructed by Concern Executive Engineer.
33 ds0oh0 flaxy Qst ih0Vh0 yxkus dk dk;ZA
33 ds0oh0 400 ,Eih;j cl vkblksysVj yxkus dk dk;ZA
33 ds0oh0 cl ,oa ykbZu vkblksysVj gsrq IyhaFk ,oa Qkm.Ms'ku lfgr LVªDpj yxkus dk dk;ZA
33 ds0oh0 iksLV bUlqysVj gsrq IyhaFk ,oa LVªDpj Qkm.Ms'ku lfgr LVªDpj yxkus dk dk;ZA
11 ds0oh0 dscy TokabV fdV 300 sqmm XLPE dsfcy esa yxkus dk dk;ZA
33 ds0oh0 iksfyej fMLd bUlqysVj fQfVax ds lkFk yxkus dk dk;ZA
33 ds0oh0 iksLV bUlqysVj yxkus dk dk;ZA
iSaFkj d.MDVj ds lkFk fMLd fQfVax djrs gq, LVªDpj lfgr esu cl ckj yxkus dk dk;ZA
24 oksYV cSVjh ,oa cSVjh pktZj dks fQfVax ds lkFk yxkus dk dk;ZA
33 ds0oh0 flaxy dUVªksy iSuy yxkus dk dk;ZA
11 ds0oh0 300 sqmm dscy ckDl Lohp xh;j ,oa VªkalQkeZj ij yxkus dk dk;ZA
LT XLPE 3.5X400 sqmm dscy fcNkdj yxkus dk dk;ZA
,0lh0,l0vkj0 Mkx dUMDVj fcNkus ,oa lSfxax ,oa ckbZafMax djus dk dk;ZA
33 ds0oh0 400 ,Eih;j ykbZu vkbZlksysVj yxkus dk dk;ZA
05 MVA ikWoj ifjorZd dks u;s IyhaFk ij LFkkfir dj dsfcy] yx rFkk ¶;wt lsV yxkdj ÅthZd`r djus dk dk;ZA
33 ds0oh0 Q;wtlsV yxkus dk dk;ZA
33 ds0oh0 dUVªksy iSusy yxkus dk dk;ZA
33 ds0oh0 lh0Vh0 200@100@1,0 yxkus dk dk;ZA
11 ds0oh0 3X300 SQ MM XLPE dscy fcNkdj bZaV ckyw yxkrs gq, mthZd`r djus dk dk;ZA
11 ds0oh0 vkmVxksbax oh0lh0oh0 yxkus ,oa VsfLVax djrs gq, mthZd`r djus dk dk;ZA
33 ds0oh0 oh0lh0oh0 ¼800A, 750MVA½ yxkrs gq, mthZd`r djus dk dk;ZA
11 ds0oh0 cl dIyj oh0lh0oh0 iSuy yxkus ,oa pkyw djus dk dk;ZA
11 ds0oh0 budfeax oh0lh0ch0 yxkrs gq, mthZd`r djus dk dk;ZA
33 ds0oh0 ykbZfVax vjsLVj yxkus dk dk;ZA
LT XLPE cable 3.5x150 sq.mm fcNkdj yxkus dk dk;ZA
33 ds0oh0 ikWfyej ihu balqysVj yxkus dk dk;ZA
250 ds0oh0,0 11@0-4 ds0oh0 u;k ifjorZd yxkus ,oa mthZd`r djus dk dk;ZA
,l-,e-lh usecksMZ IyhaFk ds lkFk yxkus dk dk;ZA
33 ds0oh0 Q;wtlsV LVªDpj yxkus dk dk;ZA
Qk;j cdsV 04 ua0 ckyw ,oa LVSaM lfgr yxkus dk dk;ZA
rail pieces 90 LBS IyhaFk ij xkus dk dk;ZA
ikWoj ifjorZd gsrq U;wwVªy ,oa ckMh vfFkZax yxkus dk dk;ZA
fire extenguisher with dry powder (5kg) yxkus dk dk;ZA
33 ds0oh0 ykbZfVax vjsLVj LVªDpj yxkus dk dk;ZA
Fire extenguisher co2 type 5Kg yxkus dk dk;ZA
vkWmVMksj Lohp;kMZ gsrq ,oa vizksp ekxZ ij vkj-Mh- ykbZfVax yxokus dk dk;ZZA
COPPER CONTROL CABLE 2X2.5 SQ.MM yxkus dk dk;ZA
ih-th- DySai Mkx Vw Mkx yxkus dk dk;ZA
jcj eSV yxkus dk dk;ZA
33 ds0oh0 ih-Vh- dk LVªDpj yxkus dk dk;ZA
,y0,0]lh-Vh ,oa ih-Vh ds fy, dsfedy ikbi vfFkZax yxkus dk dk;ZA
oh0lh0oh0 iSuy ds fy, IyhaFk ,oa Qkm.Ms'ku rS;kj djus dk dk;ZA
T/F bus complete with structure yxkus dk dk;ZA
ih-th- DySai iSaFkj Vw Mkx yxkus dk dk;ZA
COPPER CONTROL CABLE 4X2.5 SQ.MM yxkus dk dk;ZA
lh-Vh- LVªDpj IyhaFk Qkm.Mslu lfgr yxkus dk dk;ZA
vksYM IyhaFk fjis;j djus dk dk;ZA
fcfYMax ,oa Lohp;kMZ dk uke isUV }kjk fy[kus dk dk;ZA lkexzh lfgr
lcLVs'ku LVªDpj bR;kfn dks isUV djus dk dk;Z] lkexzh lfgrA
33@11 ds0oh0 fo|qqr lcLVs'ku ds uohuhdj.k@vk/kqfudhdj.k gsrq pkjksa vksj ls ckcsZM ok;j lfgr pgkjfnokjh ls ?ksjkcanh djus ,oa xsV yxkus dk dk;Z] lkexzh lfgrA
250 ds0oh0,0 forj.k ifjorZd U;wVªy ,oa ckMh ds vfFkZax dk dk;ZA
Max /Min line diagram cksMZ ij cukdj midsUnz ij yxkus dk dk;ZA
,y-Vh- dscy yxkus gsrq Vªsap lkexzh lfgr cukus dk dk;ZA
33 ds0oh0 dsfcy gsrq U;w Vªsap cukus dk dk;Z] lkexzh lfgrA
11 ds0oh0 dsfcy gsrq U;w Vªsap cukus dk dk;Z] lkexzh lfgrA
11 ds0oh0 dsfcy gsrq ,e-,l pSuy yxkdj dsfcy LVSaM cukus dk dk;ZA lkexzh lfgrA
VªaklQkeZj U;wVªy LVS.M ,e-,l- pSuy yxkdj cukus dk dk;ZA lkexzh lfgrA
daVªksy dscy taD'ku ds fy, is;j ckDl yxkus dk dk;ZA
iSuy ,oa vU; midj.k gsrq ,y-Vh- ykbZu dk fMLVªC;w'ku djus ds fy, ACDB ckDl yxkus dk dk;ZA lkexzh lfgrA
LVªDpj ds fy, th0vkbZ0 iV~Vh 50x6 dks yxkus dk dk;ZA
LVªDpj ds fy, th0vkbZ0 iV~Vh 25x6 dks yxkus dk dk;ZA
iqjkus iksy VªkalQkeZj dks mrkjdj dk;ZLFky ij gh lgh txg ij yxkus dk dk;ZA
Laying out & windup of old and used XLPE cable.
opening of trench cover to windup of existing cable and resetting after work completion.
Cleaning of existing Trench filled of soil etc.
Opering of cable from switch gears panel and earthing of panel
Digging of Pakka CC work to dismount the switchyard structures. With material
33@11 ds0oh0 fo|qqr lcLVs'ku ds uohuhdj.k@vk/kqfudhdj.k gsrq lc LVs'ku ds leLr midj.kksa ds VsfLVax djrs gq, mthZd`r djus dk dk;ZA
33@11 ds0oh0 fo|qqr lcLVs'ku ds uohuhdj.k@vk/kqfudhdj.k gsrq ydM+h dh dqlhZ 4 ux est 1 ux ia[kk bR;kfn yxokus dk dk;ZA lkexzh lfgrA
LVsjkWM dEiyhV lsV 20 ,e-,e- yxkus dk dk;ZA
33 ds0oh0 TokabUV fdV vkmVMksj type 3x300 sq.mm yxkus dk dk;ZA
STP Double Pole 11 Mtr dks x<~<k [kksndj leLr fQfVax yxkrs gq, mthZd`r djus dk dk;ZA
vfFkZax dEiyhV th-vkbZ jkM yxkus dk dk;ZA
33 kv 3x300 sq.mm XLPE Cable dks 33 ds0oh0 ehVjhax ij yxkus dk dk;ZA
33kv T.V.M dks Hk.Mkj dsUnz ls lqjf{kr ynkbZ <qykbZ djrs gq, yxkus dk dk;ZA
G.I. PIPE 6" DIA dks dsfcy esa yxkus dk dk;ZA
uEcj IysV yxkus dk dk;ZA
BARBED WIRE yxkus ,oa cka/kus dk dk;ZA
Alluminium Tape(0.77x6.4 mm) miyC/k djkus o yxkus dk dk;ZA
DANGER BOARD yxkus dk dk;ZA
33KV XLPE Cable (3x300) yxkus dk dk;ZA
Concreting of stay dh xzkmfVax djus dk dk;ZA lkexzh lfgrA
iksyksa dh xzkmVhax djus dk dk;ZA lkexzh lfgrA
33 ds0oh0 TokabafVax fdV yxkus dk dk;ZA
leLr LFkkbZ VsªUp dk fuekZ.k dk;ZA
Construction of 3X3 Mtr PPMC room with Gate as per requirement including trench, 1.5 Mtr wide interlocking approach road from main road and flooring complete work.
33 ds0oh0 lh-Vh- ih-Vh- Hk.Mkj dsUnz ls izkIr djds lqjf{kr ynkbZ <qykbZ djrs gq, yxkus o ekm.Vhax djus o fQfVax djus dk dk;ZA
ehVfjax gsrq dEiyhV vkmVMksj vfFkZax yxkus ekm.Vhax djus o fQfVax djus dk dk;ZA
33KV Pilfer Proof ehVfjax D;wfcdy ckDl dks Hk.Mkj dsUnz ls izkIr djds ynkbZ <qykbZ djrs gq, yxkus dk dk;ZA
CT/PT UNIT dks f'kQ~V djus ,oa ynkbZ <wykbZ djrs gqm y;s Mcy iksy ij yxkus dk dk;ZA
33KV PPMC dks f'kQ~V dj ynkbZ <wykbZ djrs gq, u;s LFkku ij yxkus dk dk;ZA
33@11 ds0oh0 fo|qqr lcLVs'ku ds uohuhdj.k@vk/kqfudhdj.k gsrq vU; eSVsfj;y bR;kfn dks Hkh f'k¶V djus gsrq ynkbZ <wykbZ dk dk;ZA
Laying of 33 KV Cable Double circuit including cost of sand in trench
Laying of double ckt 11 kv cable on existing cable tray both Double circuit complete work for outgoing panel to pump house
Earthing of S/S Outdoor equipement and complete switchyard (22x16 Mtr) Earthmat work.
Earthing of complete Indoor equipement (GI earthing both side and required MS strip 40*6 mm, 20 mtr each including 32 mm MS Bars)
Power Transformer Delta neutral Earthing and Body Earthing including neutral support structure.(GI pipe) of length 20 mtr each.
(T & P of S/S as per specification, pliers 4 no, Meggar 5 kv 1 no, wrench 1 set whole, hammer 1 no, 2 no Saw, 2 no. Axe, 2 no. long rope, 2 no. earth chain, 1 no. ladder, Ladder trolley 1 no., safety belt 2no., pulley 1 no.) leLr Vh0 ,.M ih0 lkexzh miyC/k djkus dk dk;ZA
KRIPA ELECTRICAL WORKS AND SUPPLIER (BID ID -5310396)
M/S SMM INFRATECH PVT Ltd (BID ID -5311558)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .