Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAdmitted-Finance 9TH FLOOR 920 WAVE SILVER TOWER SECTOR 18 NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L1 | Admitted-Finance | |
| 2 | L2₹3.1 Cr+₹16.3 L (5.47%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹4 Cr+₹1.0 Cr (33.9%)Admitted-Finance A 21 BEHIND LIONS CLUB SCHOOL III PHASE THIRU VI KA INDUSTRIAL ESTATE GUINDY CHENNAI 600 032 | CHENNAI | TAMIL NADU | 600001 | L3 | Admitted-Finance | |
| 4 | Rejected-Technical 86 UNIVERSAL INDUSTRIAL ESTATE I B PATEL ROAD GOREGAON EAST MUMBAI 400063 | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | - | Rejected-Technical Pursuant to clause II.3 of NIT, Firm is not meeting NIT criteria for similar works. |
| Sl No | Description | Qty | Unit | CGMP Projects Pvt. Ltd L1 | Hubert Enviro Care Systems Limited L3 | Komal Industries L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of Ultra Pure Water (UPW) Plant of capacity 1.2 CMH and 18 M Ohm-cm resistivity complete with monitoring and control system as per Technical Specification Sheet - 01. | 1 | Set | 1,97,45,985 ₹1,97,45,985 | 2,58,84,000 ₹2,58,84,000 | 1,71,09,450 ₹1,71,09,450 Lowest |
| 2.00Supply, installation, testing and commissioning of Polypropelyne Homopolymer (PPH) pipes and fittings of size 25 mm for UPW loop as per following details and Technical Specification Sheet - 02. | ||||||
| 2.10 | Pipes | 150 | RM | 401 ₹60,150 | 250 ₹37,500 Lowest | 850 ₹1,27,500 |
| 2.20 | Bends | 25 | Nos | 437 ₹10,925 | 130 ₹3,250 Lowest | 450 ₹11,250 |
| 2.30 | Union | 10 | Nos | 549 ₹5,490 | 250 ₹2,500 Lowest | 340 ₹3,400 |
| 2.40 | Tee | 20 | Nos | 512 ₹10,240 | 150 ₹3,000 Lowest | 180 ₹3,600 |
| 3.00 | Supply,installation, testing and commissioning of PVDF magnetic pumps with remote operation of capacity 30 LPM with Head of 5 Meters on 1000 kg/m3 density head complete with all accessories as per Technical Specification Sheet - 03. | 7 | Nos | 46,797 ₹3,27,579 Lowest | 1,14,200 ₹7,99,400 | 63,400 ₹4,43,800 |
| 4.00Supply, installation, testing and commissioning of double walled chemical storage tanks of following material and capacity along with other accessories as mentioned below and as per Technical Specification Sheet - 04. | ||||||
| 4.10 | FRP tank of capacity 1 m3 with PVDF Lining and accessories with cooling PVDF tubes for inside liquide | 3 | Nos | 2,54,745 ₹7,64,235 Lowest | 3,16,650 ₹9,49,950 | 4,20,000 ₹12,60,000 |
| 4.20 | FRP tank of capacity 2 m3 with PVDF Lining and accessories with cooling PVDF tubes for inside liquide | 2 | Nos | 4,53,714 ₹9,07,428 | 4,50,000 ₹9,00,000 Lowest | 6,50,000 ₹13,00,000 |
Tender Value
₹5.1 Cr
EMD Value
₹10.3 L
Closing Date
6 Aug 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer and Head, TSD
Technical Services Division, BARC, Trombay, Mumbai-400085
Supply, Installation, Testing and Commissioning of Ultra-Pure Water Plant and Chemical Scrubber along with associated miscellaneous work for Clean Room Facility at H-9, NPD, BARC, Mumbai-85
2026_BARC_915397_1
BARC/TSD/ET/11/2026-2027
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
365 days
H-9, NPD, BARC, TROMBAY
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹10.3 L
5 Oct 2026
2 Jul 2026
13 Aug 2026
2 Jul 2026
6 Aug 2026
2 Jul 2026
2 Jul 2026 - 13 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of Ultra Pure Water (UPW) Plant of capacity 1.2 CMH and 18 M Ohm-cm resistivity complete with monitoring and control system as per Technical Specification Sheet - 01. | 1 | Set | - | - |
| 2Supply, installation, testing and commissioning of Polypropelyne Homopolymer (PPH) pipes and fittings of size 25 mm for UPW loop as per following details and Technical Specification Sheet - 02. | |||||
| 2.1 | Pipes | 150 | RM | - | - |
| 2.2 | Bends | 25 | Nos | - | - |
| 2.3 | Union | 10 | Nos | - | - |
| 2.4 | Tee | 20 | Nos | - | - |
| 3 | Supply,installation, testing and commissioning of PVDF magnetic pumps with remote operation of capacity 30 LPM with Head of 5 Meters on 1000 kg/m3 density head complete with all accessories as per Technical Specification Sheet - 03. | 7 | Nos | - | - |
| 4Supply, installation, testing and commissioning of double walled chemical storage tanks of following material and capacity along with other accessories as mentioned below and as per Technical Specification Sheet - 04. | |||||
| 4.1 | FRP tank of capacity 1 m3 with PVDF Lining and accessories with cooling PVDF tubes for inside liquide | 3 | Nos | - | - |
| 4.2 | FRP tank of capacity 2 m3 with PVDF Lining and accessories with cooling PVDF tubes for inside liquide | 2 | Nos | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 23.48 MB
SCHEDULEA.pdf
Tender Documents • 0.15 MB
ProformaOfSchedules.pdf
Tender Documents • 0.14 MB
TechnicalSpecificationSheets.pdf
Tender Documents • 0.64 MB
BOQ_962018.xls
BOQ • 0.23 MB
TenderDocument.pdf
Tender Documents • 1.91 MB
TECHNICALBIDET11.xls
Tender Documents • 0.17 MB
CORRIGENDUM4.pdf
PDF • 0.16 MB
CORRIGENDUM3DateExtension.pdf
PDF • 0.10 MB
CORRIGENDUM2.pdf
PDF • 0.14 MB
CORRIGENDUM1.pdf
PDF • 1.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .