Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | ₹33.6 L Quoted ₹34.7 L | L1 | Accepted-AOC AOC |
| 2 | L2₹45.4 LRejected-Finance GSTIN: 23CKHPS3749B1Z715 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | ₹45.4 L | L2 | Rejected-Finance Not being L1 bidder |
| 3 | L3₹46.8 LRejected-Finance GSTIN: 23ACXPT9554HIZQC 187 NIRMAN VIHAR DELHI 92 | ₹46.8 L | L3 | Rejected-Finance Not being L1 bidder |
| Sl No | Description | Qty | Unit | M/S KAPIL CONSTRUCTION CO L3 | Akarsha Enterprises L1 | M/s Anupam Construction Co. L2 |
|---|---|---|---|---|---|---|
| 1.00 | Disconnecting, dismantling and taking out old U/S ACSR conductor of any size out lived broken unserviceable including removing binding wire from insulators/jumpers complete all as specified and directed by EIC. | 8 | Qtl | 800 ₹6,400 | 500 ₹4,000 | 3,000 ₹24,000 |
| 2.00 | Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 3½ core 240 sq mm complete all as specified and directed . | 340 | RM | 2,018 ₹6.9 L | 690 ₹2.3 L | 1,325 ₹4.5 L |
| 3.00 | Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 3½ core 185 sq mm complete all as specified and directed . | 250 | RM | 1,618 ₹4.0 L | 599 ₹1.5 L | 1,300 ₹3.3 L |
| 4.00 | Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 3½ core 150 sq mm complete all as specified and directed . | 850 | RM | 1,258 ₹10.7 L | 575 ₹4.9 L | 1,200 ₹10.2 L |
| 5.00 | Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 3½ core 95 sq mm.completed | 350 | RM | 868 ₹3.0 L | 475 ₹1.7 L | 800 ₹2.8 L |
| 6.00 | Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 3½ core 50 sq mm complete all as specified and directed . | 300 | RM | 498 ₹1.5 L | 395 ₹1.2 L | 475 ₹1.4 L |
| 7.00 | Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 3½ core 35 sq mm complete all as specified and directed . | 1,200 | RM | 348 ₹4.2 L | 365 ₹4.4 L | 375 ₹4.5 L |
| 8.00 | Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 4 core 25 sq mm complete all as specified and directed . | 540 | RM | 308 ₹1.7 L | 325 ₹1.8 L | 325 ₹1.8 L |
| 9.00 | Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 4 core 16 sq mm complete all as specified and directed . | 100 | RM | 258 ₹25,800 | 245 ₹24,500 | 220 ₹22,000 |
| 10.00 | Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 4 core 10 sq mm complete all as specified and directed . | 100 | RM | 198 ₹19,800 | 195 ₹19,500 | 160 ₹16,000 |
Updated dates
Tender Value
₹43.2 L
EMD Value
₹86,500
Closing Date
10 Apr 2026, 6:00 pmClosed
GE (AF) Adm Area Gwalior
GE (AF) Adm Area Gwalior -474020
Repair/ replacement of OH conductor to UG cable in domestic area Ph-II at AF Station Gwalior
2026_MES_756236_1
8579/E8
Open Tender
Electrical and Maintenance Works
210 days
GE (AF) Adm Area Gwalior
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Adm Area
₹86,500
Yes
3 Jun 2026
13 Mar 2026
17 Apr 2026
13 Mar 2026
10 Apr 2026
27 Mar 2026
Disconnecting, dismantling and taking out old U/S ACSR conductor of any size out lived broken unserviceable including removing binding wire from insulators/jumpers complete all as specified and directed by EIC.
Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 3½ core 240 sq mm complete all as specified and directed .
Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 3½ core 185 sq mm complete all as specified and directed .
Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 3½ core 150 sq mm complete all as specified and directed .
Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 3½ core 95 sq mm.completed
Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 3½ core 50 sq mm complete all as specified and directed .
Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 3½ core 35 sq mm complete all as specified and directed .
Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 4 core 25 sq mm complete all as specified and directed .
Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 4 core 16 sq mm complete all as specified and directed .
Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 1100 volts grade,of size 4 core 10 sq mm complete all as specified and directed .
Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels for laying of cable etc including taking out existing cable protection brick PCC cover etc complete all as specified and directed .
Returning, filling in, including spreading levelling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed
Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed
M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. Note : Punned thickness shall be measured & paid.
Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable all as specified and directed by Engr-in-Charge.
Supply & Fix 80 mm bore light grade galvanized iron tubing ISI marked etc laid in trenches or fixed on wall floor in GI pipe complete all as specified and directed.
Supply & Fix 50 mm bore light grade galvanized iron tubing ISI marked etc laid in trenches or fixed on wall floor in GI pipe complete all as specified and directed.
S&F MCCB 125 Amps 3 Pole, 16 KA, 415 V, 50 Hz with thermal setting between 70% to 100% adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
Supply and installation & Testing factory made CPRI approved LT feeder pillar box of size 60cmX45cmX30cm for 3 phase, 4 wire, 415Volt, AC, 50Hz, outdoor, cubical type, weather, dust and vermin proof, pedestal mounting type suitable for front operated applications having aluminium bus bar rating capacity 400Amps and neutral 300 Amps rating capacity mounting of insulators, incoming controlled with fixed type MCCB 3 Pole of capacity 250 Amps and breaking capacity Icu= 36KA including canopy on top and gland provision in bottom made out of 3.15mm thick MS sheet duly powder coated of approved shade using 40mmX40mmX6mm angle iron frame and supports including necessary excavation and grouting the same in PCC 1:2:4 mix, type B1 complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 25x4 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing complete all as specified & directed.
S&F for cable jointing kit in repairs for 1.1 KV grade cable for end termination heat shrinkable type joints with jointing material and accessories suitable for 3.5 core 16 to 50 sqmm XLPE insulated armoured aluminium conductor cable complete all as specified directed by Engr-in-Charge.
S&F for cable jointing kit in repairs for 1.1 KV grade cable for end termination heat shrinkable type joints with jointing material and accessories suitable for 3.5 core 70 to 120 sqmm XLPE insulated armoured aluminium conductor cable complete all as specified directed by Engr-in-Charge.
S&F for cable jointing kit in repairs for 1.1 KV grade cable for end termination heat shrinkable type joints with jointing material and accessories suitable for 3.5 core 150 to 300 sqmm XLPE insulated armoured aluminium conductor cable complete all as specified directed by Engr-in-Charge.
M&L for PCC (1:4:8) Type D-2 using 40mm graded stone aggregate as in foundation/repairs to damaged road/footpath/plinth for panels etc. including necessary formwork complete all as specified.
M&L for PCC (1:2:4) Type B-1 using 20mm graded stone aggregate as in repair to footpath/hard standing/plinth for panels etc. including necessary formwork complete all as specified.
Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 50 mtr etc complete all as specified
Boring of holes under road, pavement, hard standing by mannual borring and including supply and laying insertion of HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as specified and directed.
Supply & Fix 15 mm bore light grade galvanized iron tubing ISI marked including all fittings etc fixed on pole including suitable size clamps, nut and bolts protection pipe for street light cable from junction box to street light complete all as specified and directed
Supply and fixing in replacement copper conductor flexible cable with PVC insulator multi-stranded 2 x 2.5 sqmm 1100 volt drawing in to the street light pole incl connection for security light from junction box to street light fitting complete all as specified & directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tender8579.pdf
Tender Documents • 0.96 MB
BOQ_847079.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid