DGM Unit Electric JKPCC Ltd Srinagar
DGM Unit Electric JKPCC Ltd Srinagar
Internal electrification of Workshop Block and Balance Work of Engineering College at Safapora
2021_PWDJK_125910_1
08/E/K of 2021-22
Open Tender
Electrical Works
Item Rate
90 days
Ganderbal
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,500
Yes
FC JKPCC Ltd a/c
Yes
GM JKPCC Ltd Srinagar
14 Jul 2021
4 Jun 2021
25 Jun 2021
4 Jun 2021
24 Jun 2021
4 Jun 2021
12 Jun 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed Pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A, “C” curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supply,installation,testing and commissioning of Ceiling fans (crompton greaves High Breez or approved equivalent) complete with double ball bearig, motor bearing, r, blades, down-rod canopies capacitor two module stepped type electronic fan regulator suitable for operation on 230V 50HZ 1-phase A.C supply complete as required
14oomm sweep
Supply,installation,testing & commissioning of 900 RPM 300mm ( Crompton Greaves trans Air or approved equivalent ) Exhaust Fan suitable for single phase 230v 50HZ AC supply Complete with motor louvers,shutters etc complete as required
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection / termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting / sweating and soldering etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Suply and installation of integral LED 4ft luminarie with CRCA housing and PC Glossy Cover.The luminarie should have a color consistency SDCM < 5, CRI> 80 and CCT of 6500K.The luminarie shall be compliant with IP 20 classification. Luminarie shall be designed to emitt at least 4000 nominal lumens at a system efficacy of attleast 115 lumens / watt with a maximum warrage of 34watts.The luminarie shall be designed so as to ensure lumen depriciation of upto 30% over 50K burning hours @ design ambient temp 45deg C. The electronic driver used shall have a power factor > 0.95 and THD < 10% and suitable for an operating voltage range of 140-270 V AC.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics, IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0, 2007 for Electrical safety, IEC62384 ed 1.1, 2011 for perfofmance and IEC 61547 ed 2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt, of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above parameters
Laying 0f one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required.
Above 185 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X 240 sq. mm
Supplying of cables for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X 240 sq. mm A2XFY
Laying 0f one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required.
Above 35 sq. mm and upto 95 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X 70 sq. mm
Supplying of cables for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X 70 sq. mm A2XFY
Supply,Installation,testing and Commissioning of Cubical type L.T Panel board suitable for 415V 3phase 4wire 50HZ AC supply system including incomers,outgoings,bus-bar,interlocking etc,dust & vermin proof with lockable arrangement, powder coated with stand location (workshop block ) INCOMERS MCCB 400 Amp 4 Pole breaking 36 KA with spreader 1no Digital multifunctional-meter 1 no Indicating Lamps ( RYB ) 1 set Current-Transformer ( 300/5A 10VA burden) class-1 1set Aluminium bus-bar 1200 Amp FP E-91 Electrolutic AL 1sets. 200A change over switch Panel Mount :1 No. Out-Goings MCCB 63 Amp 4 Pole with breaking 36 KA with spreaders 8 N0 MCB 80 Amp DP MCCB with Breaking capacity 36 KA 1 Nos MCB 32/40 Amp DP MCB with Breaking capacity 16 KA 10 Nos SP MCB 6-16 Amp 16 Nos Load Bearing Member to be made out of 16SWG CRCA Sheet Partition to be made out of 16SWG CRCA Sheet Gland Plates to be made16 SWGmm thick Complete job.
Supply,Installation,testing and Commissioning of Cubical type L.T Panel board suitable for 415V 3phase 4wire 50HZ AC supply system including incomers,outgoings,bus-bar,interlocking etc,dust & vermin proof with lockable arrangement, powder coated with stand location (Academic block ) INCOMERS MCCB 160Amp 4 Pole breaking 36 KA with spreader 1no Digital multifunctional-meter 1 no Indicating Lamps ( RYB ) 1 set Current-Transformer ( 300/5A 10VA burden) class-1 1set Aluminium bus-bar 300 Amp FP E-91 Electrolutic AL 1sets. 200A change over switch Panel Mount :1 No. Out-Goings MCB 63 Amp DP with breaking capacity 10 KA 3 N0 MCB 80 Amp DP MCCB with Breaking capacity 10 KA 3 Nos Load Bearing Member to be made out of 16SWG CRCA Sheet Partition to be made out of 16SWG CRCA Sheet Gland Plates to be made16 SWGmm thick Complete job.
Supply & Erection of 11meter long steel tubular poles.The pole is duly fitted with 2x2 ft flat iron base plate at the bottom and cap at the top of the pole complete with excuavation of pole trench and erecting of pole in the trench including cost of excuvation of trench & one coat of steel primer and two coats of steel silver/red paint complete job
Providing and laying of plum concrete blocks with 1:2:4 ratio (1 cement: 2coarse sand; 4 stone agg/boulders) complete job
Supply and fixing of iron rings made of steel duly fabricated and painted to be fixed on top of pole for holding lights
Supply and fixing of suitable size PVC pole box with connectors and base for holding MCB's
Supply and fixing of 6Amp SP MCB
Supply and fixing of 20Amp DP MCB
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.
150 mm width X 50 mm depth X 1.6 mm thickness
SITC of high-quality integrated LED Flood Light with a minimum system lumen of 23500 Lm and system wattage not exceeding 195W with a nominal efficiency 120 lumen/watt. CCT of 6500K with SDCM of < 5 and CRI : 70. The housing should be of non-corrosive high-pressure die-cast aluminum to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70. The Ingress protection should be minimum IP 66 with an IK rating of 09. The Luminaire should have a 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. EMI.Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above parameters
M/S ZAHID ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .