Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 CrAccepted-AOC 519 P SECTOR 3 URBAN ESTATE KURUKSHETRA 136118 | KURUKSHETRA | KURUKSHETRA | HARYANA | 136118 | ₹8.7 Cr | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | - | - | Rejected-Technical Higher rates |
| 3 | Rejected-Technical RGTPP KHEDAR HISAR HARYANA | HISAR | HARYANA | 125001 | - | - | Rejected-Technical Higher rates |
| 4 | Rejected-Technical | - | - | Rejected-Technical Higher rates |
| 5 | Rejected-Technical | - | - | Rejected-Technical Higher rates |
Tender Value
Refer Docs
EMD Value
₹18 L
Closing Date
6 Jan 2021, 10:00 amClosed
Secretary and ME
Cheeka
Construction of Stadium In Municipal Committee Cheeka
2020_HRY_154249_1
CM/MCC/2020/1/1
Open Tender
Civil Works
Works
365 days
Construction of Stadium In Municipal Committee Che
Please refer Tender documents.
2 documents required · 2 mandatory
₹20,000
Yes
₹18 L
Yes
31 Oct 2022
24 Dec 2020
6 Jan 2021
24 Dec 2020
6 Jan 2021
24 Dec 2020
Amount
Providing and fixing Readymade information signs for service areas in stainless steel finish (Grade 304 , 1.5-2mm thk.) with information embossed or cut out with appropriate lettering/Pictograms/ complete as per the attached reference images. Lettering font,size and content subject to final approval of the architect in charge. SERVICE AREAS-SIZE OF PLATE 6"X6" with rounded edges
Providing and fixing Readymade information signs for service areas in stainless steel finish (Grade 304 , 1.5-2mm thk.) with information embossed or cut out with appropriate lettering/Pictograms/ complete as per the attached reference images. Lettering font,size and content subject to final approval of the architect in charge. FUNCTIONAL AREAS -SIZE OF PLATE 12"x3"
Providing and fixing Room plates on glass/wooden partitions / glass doors as per the approved location. Size of the SS plate(Grade 304 , 1.5-2mm thk.)- 6" x 6" with acrylic black rimming sliding room occupany indicator , lettering to be embossed/etched complete as per the attached image.Font and final design subject to final approval of the architect in charge.
Providing and fixing Directional signage on toughened glass sheet .Content to be displayed using plotter cut lettering on one side of the sheet, with additional taping to achieve a unifrom background . Lettering font,size ,color and content subject to final approval of the architect in charge. Cost to include mounting of glass sheets using SS Studs on masonary wall surface or suspending the sheets using ss rods from the ceiling.
Providing and installing Fire exit sign ceiling hanged, led Emergency with Ni-cd Battery backup capable of emergency backup of 2hr. Complete with hanging accessoires to the satisfaction of Engineer-in-charge.
Providing and installing Color Coded Dustbin DUO made of FRP Size: 406B x H813 xL813mm With Plastic bucket of 60L Each Colors & Graphics to be customized as per the directions of the architect
Providing and laying 200 mm thick granular sub base consisting of 1120.94 drainage layer confirming to Table 400.1 Grading -VI of MORT&H 5th edition, mixing in a mechanical mix plant at OMC, carriage of mix material to the site of work, spreading in uniform layer with motor grader on prepared surface and compacting with vibratory power roller to achieve desired density complete as per clause No.401 of MORT&H specifications for road & bridge (5th Revision) of 2013. (NS)
Providing & laying 75mm thick (Compacted) stone metal (G-II) 53mm to 22.4mm gauge wearing coat to waterbound macadam in layer of 75 mm each using screening type 'B' compacting with 3 wheeled steel roller/vibratory roller to achieve the desire density including lighting, guarding barricading and maintenance of diversion etc. as per clause No.404 of MORT&H specifications for road & bridge (5th Revision) of 2013 as per drawing and design directed by the Engineer complete in all respects. (NS).
Providing & Fixing of GRC tiles of approved shade over 12 mm thick cement mortar 1:4 for exposed outer surface for all heights including the cost of scaffolding complete in all respect. (Note:- Reputed make Tile such as Unistone, shall be used as approved by Engineer-in-charge. (NS) (Labour Rate)
Proflex Systems roof for hall
Design, supply, installation, testing and commissioning of 40 KW grid tied roof top solar PV powerplant TECHNO-COMMERCIAL PROPOSAL Of 3 Phase solar grid tie power plant complete withallequipment, as required upto PCU including synchronizationwith grid supply and civil foundation work formodulemountingstructure. The system includes the appropriateno.ofPVModules, mounting structure for themodules. Array Junction boxes, all cabling according to thesite andsystem requirement as follows or as perapproveddrawings.Specifications of the tenderanddirectionsofSite Incharge. The rate includes thefollowing items as per site requirementand as pe+rmanufacturer's specification complete in all respects. The design should be gotapprovedfrom the Architect & Engineer-in-Charge before execution with five years warranty against manufacturing defects.
Supply. Eerection and testing and commissioning of 80/ 85/100 watt indoor decorative rcess mounted LED laminate suitable for USG, GRD, MODULAR, ARMSTRONG ( Sixe 2x2 feet) false ceiling module including necessary connections with 2.5 sqmm PVC copper flexible cable for connecting the luminaire and including cost of Suspended mounting accessories etc. with all other accessories complete in all respect up to the entire satisfaction of engineer incharge of the work, Make:- Philps, Bajaj. GE, Wipro.. K-lite, Crompton greaves.
Providing & laying imported Maple wood surface board finish with 21mm.55 to 85 mm width and in random length in tom and groove shape having edges of boards with finger loop grove and thewbottom side with air pass groove over a frame of pine wood runners 70mm x 45mm treated with antitermide solution and fixed on bottom side with 10mm thick epdm air cushning pads by nails through the two wings at 350mm c/c.
Supplying and fixing ms hooks for GI pipe.
Providing and fixing 1 HP motor for pumping water from underground water tank to PVC water tank
Provding And Supply of Led BAJAJ Tube Light
Provding And Supply of BAJAJ Wall Light
Provding And Supply Orient,BAJAJ,KHAITAN Electric Ujala 1200 Mm Energy Saving 3 Blade Ceiling Fan,
S/E of 100 WATT LED light lumaniries of philips , Bajaj / crompton / Surya with lamps to complete the job in all respects in connection of the same on the lantern carriage as per specification
Earthing Copper Bonded Steel with 23.2 mm dia. Supply, Installation, Testing & Commissioning of long life Maintenance Free Earthing System . The Rod shall be of Copper Bonded Steel with 23.2 mm dia. and 10 feet length with a core of mild steel molecularly bonded with min. 250 microns coating of 99.99% pure electrolytic grade Copper and exothermically welded Cu Busbar of 50X6X200mm tested by CPRI capable of bearing fault current of 50kA. Along with earth enhancement compound (jam plus) tested by RoHs complying IEC 62561-7 in a sealed bag of minimum 30 kg (10 kg Bag x 3) resistivity is less than 0.2 ohm meter. The earth station shall be with Suitable Poly-plastic Pit Cover with lockable arrangement. (for neutral and body 500 kva transformer) including cost of petty material required to complete the job in all respect. Make: JMV or equivalent model of ERICO, OR FURSE, OBO.
Copper Bonded Steel with 14.2 mm dia. Supply, Installation, Testing & Commissioning of long life Maintenance Free Earthing System. The Rod shall be of Copper Bonded Steel with 14.2 mm dia. and 10 feet length with a core of mild steel molecularly bonded with min. 250 microns coating of 99.99% pure electrolytic grade Copper.Along with earth enhancement compound (jam plus) tested by RoHs complying IEC 62561-7 in a sealed bag of minimum 30 kg (10 kg Bag x 3) resistivity is less than 0.2 ohm meter . The earth station shall be with Suitable Poly-plastic Pit Cover with lockable arrangement. MAKE :- JMV, ERICO, OR FURSE, OBO including cost of petty material required to complete the job in all respect. Make: JMV or equivalent model of ERICO, OR FURSE, OBO.
Supply erection testing and commissioning of long life Maintenance Free Earthing System. The Rod shall be of Copper Bonded Steel with 17.2 mm dia. and 10 feet length with a core of mild steel molecularly bonded with min. 250 microns coating of 99.99% pure electrolytic grade Copper and exothermically welded Cu Busbar of 50X6X200mm tested by CPRI capable of bearing fault current of 25 kA. Along with earth enhancement compound tested by RoHs complying IEC 62561-7 in a sealed bag of minimum 30 kg (10 kg Bag x 3) resistivity is less than 0.2 ohm meter . The earth station shall be with Suitable Poly-plastic Pit Cover with lockable arrangement. including cost of petty material required to complete the job in all respect. MAKE :- JMV, OBO BATTERMAN OR ERECO.
Supply erection testing and commissioning of single spike air terminals of 10 mm/16 mm dia.of following lengths as required and as per site conditions. the air terminal shall be manufactured with aluminium. The terminal shall be provided with the integrated / attached threaded base support suitable for mounting the terminals as per site condition. The base support shall be minimum 3 mm thick and shall have inbuilt connector fitting for connection of lightning conductor in such away that conductor contact area shall not be less than 40mm on all side of the conductor. The air terminals shall be supplied with the intermediate guy-wire supports to make it stable in case of high wind speed. including cost of petty material required to complete the job in all respect. Make: JMV, OBO BATTERMAN OR ERECO. (A) 1000 mm
Supply erection testing and commissioning of Roof Conductor for Parapet and Interconnection of Air Terminal: Supply of 8 mm dia aluminium round conductor for air termination network at parapet wall with suitable accessories like type of clamps, conductor holder etc. as required and as per specifications. including cost of petty material required to complete the job in all respect. Make: JMV, OBO BATTERMAN OR ERECO.
Supply erection of T - Connector for making straight joint of 8 mm aluminium Conductor to 8 mm dia aluminium conductor on parapet wall, roof and vertical facade of mesonery / glass / metalic work. including cost of petty material required to complete the job in all respect. Make: JMV, OBO BATTERMAN OR ERECO.
Supply erection OF Cross - Connector for making straight joint of 8 mm aluminium Conductor to 8 mm dia aluminium conductor on parapet wall, roof and vertical facade of mesonery / glass / metalic work. including cost of petty material required to complete the job in all respect. Make:JMV, OBO BATTERMAN OR ERECO.
Supply erection of Straight - Connector for making straight joint of 8 mm aluminium Conductor to 8 mm dia aluminium conductor on parapet wall, roof and vertical facade of mesonery / glass / metalic work. including cost of petty material required to complete the job in all respect. Make: JMV, OBO BATTERMAN OR ERECO.
Down ConductorSupply erection of 8 mm dia aluminium round conductor for Down conductors to be installed on vertical façade of mesonery / glass / metalic work, with suitable accessories like type of clamps, conductor holder etc. as required and as per specifications. including cost of petty material required to complete the job in all respect. Make: JMV, OBO BATTERMAN OR ERECO.
Supply erection of Test Clamp to disconnect the down conductor from the earth termination network for regular checks of the earth termination resistance value. including cost of petty material required to complete the job in all respect. Make: JMV, OBO BATTERMAN OR ERECO.
Supply erection of Expansion piece of made of 8mm aluminium at every 20 mtr to maintain the flexibility to the conductor due to heat. including cost of petty material required to complete the job in all respect. Make: JMV, OBO BATTERMAN OR ERECO.
Supply of 12.5 Meter highmast pole having 2 section Top/Bottom Dia 150/340 mm with Winch ,Drum ,Gearbox ,Ring ,Steel wire ropes, Motor , Foundation Bolt.
150 watt LED flood light syska make
Double Door control panel 100 amp for reverse/forward ring operation
Installation of pole
SITC of Manual call point with mounting box complete as required.
Sitc of Electronic hooter 6 watt output TAC approved with a range of 25-30 mtr.
providing, installing, connecting, testing and networkable logic driven analogue addressable Main Fire Alarm Control and indicating panel.The panel shall be coupled to the PA system complete in all respect. 4 loop Panel
Wiring with 2X1.5 sqmm solid PVC insulated copper conductor 100 volt grade wires in with concealed conduit including terminations, all labour and material etc complete
Supply/Fixing of self illuminated "EXIT" sings made out from not less than 4 mm of transparent acrylic sheet of 300 x 150 mm size with self illuminated plastic words of 100 mm height suspended from ceiling by means of M.S. chain or fixed of the walls as required and as directed at site.
Supply, installation, testing and commissioning of Analogue addressable Photo Smoke Detectors based with LED shall be visible from 360deg, complete as required. (Make :/ GST/Morley)
Supply, Installation, Testing and Commissioning of Fault Isolator (GST/Morley)
Supply, Installation, Testing and Commissioning of Monitor Module. (GST/Morley)
Supply, Installation, Testing and Commissioning of Control Module. (GST/Morley)
Supply and fixing Response Indicator with Dual LED
Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018-1131 (A)
Supply & fixing of CO2 type fire extinguisher, 6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018-1132 (A)
Supply, Installation, Testing and Commissioning of M.S. Pipe 'B' Class as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc. and coating of Primer and P.O. Red Paint. Make : QST/Jindal Gzb. 50mm
Supply, Installation, Testing and Commissioning of M.S. Pipe 'B' Class as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc. and coating of Primer and P.O. Red Paint. Make : QST/Jindal Gzb. 32mm
Supply, Installation, Testing and Commissioning of M.S. Pipe 'B' Class as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc. and coating of Primer and P.O. Red Paint. Make : QST/Jindal Gzb. 25mm
Supply, Installation, Testing & Commissioning of Butterfly Valve Complelte in all respects.(Make : SIR/Kartar) 150mm dia
Supply, Installation, Testing & Commissioning of Flow Switch, complete in all respects. (Make:- System Sensor) 150mm dia
Supply, Installation, Testing & Commissioning of Alarm Control Valve, complete in all respects. (Make:- System Sensor) 150mm dia
SITC of Sprinkler 68° deg, complete in all respects. (Make:- OMEX/ Life Guard/Safex) Pendent/Upright Type
SITC of Sprinkler 68° deg, complete in all respects. (Make:- OMEX/ Life Guard/Safex) Wall Mounted Type
Supply, Installation, testing and Commissioning of Normal type Rosette Plate for sprinkler
Supply and Laying of Armoured Cable 2x1.5 Sqmm. (Make:- Relison/ Paradise/ Polycab/Pirelli)
Supply and installation of Air vessel of 300 mm dia, 1000 mm height, 6 mm thick dished end 8 mm thick.
Supply and installation of Announcing Panel
SITC of Air release valve.
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m. including getting out the excavated soil & then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. & disposing of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter. DSR-16(2.10.1.2)
Constructing masonry Chamber 60x60x75cm, inside with 75 class designation brick work in cement mortar 1:5 (1 cement : 5 fine sand) for fire hydrants, with C.I. surface box 350x350mm top and 165mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12mm thick finished with a floating coat of neat cement complete as per standard design. DSR-16(18.36.1)
Supply, Installation, Testing and Commissioning of one coat of 4 mm thick 'PYPKOTE' or coatek tape anti rust pipe protection , primer and lap of 25 mm on external M.S. pipes to make an impermeable layer in trenches or on structural/masonry members complete including surface preparation. 150mm dia
Supply, Installation, Testing and Commissioning of M.S. Pipe 'C Class Heavy as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc, complete in all respect. MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)-(Under ground) a) 150mm
Supply, Installation, Testing and Commissioning of M.S. Pipe 'C Class Heavy as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc, complete in all respect. MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)-(Under ground) b)100mm
Supply, Installation, Testing and Commissioning of M.S. Pipe 'C Class Heavy as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc, complete in all respect. MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)-(Under ground) c) 80mm
SITC of Sluice Valve complete with all respect. MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)-(Under ground) 150 mm dia
Supply, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts. MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)-(Under ground) 150mm dia
SITC of Singal Headed Hydrant Landing Valve comprising of 80 mm dia flanged Bend 63 mm dia, with cap and chain conforming to IS:5290(Make : Newage/Minimax/Safex/Firex)
SITC of RRL Hose Pipe 63 mm dia × 15 Mtr. Long with GM Coupling conforming to IS : 636(Make - Newage/Jayshree/CRC)
SITC of Short Branch Pipe as per IS:903(Make : Newage/Safex/Firex)
Supply, Installation, Testing & Commissioning of Butterfly Valve complete with flanges, gasket, nut bolts 80 mm
SITC of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle
Supply, Installation, Testing & Commissioning of Fire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet.(4 WAY)
Supply, installation, testing and commissioning of Variable Refrigerant Flow modular type air-conditioning system suitable for Cooling & Heating both by multiple scroll/DC Twin rotary compressor controlled by individual inverters for each compressor complete with indoor and outdoor units with individual wired and wireless /wired remote controller for indoor units and centralized controller, interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, control cabling and fittings etc. as per details given in specifications and having following items. The out door units shall be suitable for 3 phase 4 wire system, 415V + 10 %, 50 Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply. Outdoor Units Supply, installation, testing & commissioning of Modular type outdoor units equipped with highly efficient multiple scroll/ DC twin rotary compressors(OEM manufactured) fully inverter controlled (individual inverter for each compressor) i.e. changes its speed in accordance to the variation in cooling loads, special heat exchanger, low noise condenser fan, auto check function for connection error, auto address setting and capacity as mentioned below including all hardware & accessories & including full charging of R-410A refrigerant gas complete i/c powder coating complete as per specifications. The units should be with necessary weather protection coating. The coating should be done before bringing the units to site. Out door units shall be provided with MS stand of suitable size duly painted with corrosion resistant paint suitable for outdoor application. Each ODU in the module or individual unit should have multiple compressors for better redundancy. All the units shall be provided with built-in microprocessor control panel, for automatic operation and capacity control. All compressor shall have inverter technology i.e. outdoor units shall have all inverter based compressor. The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identicle of the ODU. Each ODU wheather used individually or used to make module should have multiple compresors. All Bidders has to submit the test certificates along with the delivery of VRF/VRV Units at site. A draft Format of the same need to be submitted along with in the Technical Bid. Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP at 50% Load to be >=5.2 at 35 Deg Ambient ConditionsInsurance of Units ,Unloading at site, placement of Oudoor Units on the foundation,stands, co-ordination during execution, rendering necessary guidance for execution, supervision, testing,commissioning and startup of above mentioned VRF/VRV by OEM. Refrigerant topup or charge must be included in quoted price Note: The civil foundations reqd shall be made by the tenderer28 HP Make:VOLTAS, Toshiba,Mitisubishi Electric,Daikin,O'General,LG,SAMSUNG
Supply, installation, testing and commissioning of Variable Refrigerant Flow modular type air-conditioning system suitable for Cooling & Heating both by multiple scroll/DC Twin rotary compressor controlled by individual inverters for each compressor complete with indoor and outdoor units with individual wired and wireless /wired remote controller for indoor units and centralized controller, interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, control cabling and fittings etc. as per details given in specifications and having following items. The out door units shall be suitable for 3 phase 4 wire system, 415V + 10 %, 50 Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply. Outdoor Units Supply, installation, testing & commissioning of Modular type outdoor units equipped with highly efficient multiple scroll/ DC twin rotary compressors(OEM manufactured) fully inverter controlled (individual inverter for each compressor) i.e. changes its speed in accordance to the variation in cooling loads, special heat exchanger, low noise condenser fan, auto check function for connection error, auto address setting and capacity as mentioned below including all hardware & accessories & including full charging of R-410A refrigerant gas complete i/c powder coating complete as per specifications. The units should be with necessary weather protection coating. The coating should be done before bringing the units to site. Out door units shall be provided with MS stand of suitable size duly painted with corrosion resistant paint suitable for outdoor application. Each ODU in the module or individual unit should have multiple compressors for better redundancy. All the units shall be provided with built-in microprocessor control panel, for automatic operation and capacity control. All compressor shall have inverter technology i.e. outdoor units shall have all inverter based compressor. The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identicle of the ODU. Each ODU wheather used individually or used to make module should have multiple compresors. All Bidders has to submit the test certificates along with the delivery of VRF/VRV Units at site. A draft Format of the same need to be submitted along with in the Technical Bid. Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP at 50% Load to be >=5.2 at 35 Deg Ambient ConditionsInsurance of Units ,Unloading at site, placement of Oudoor Units on the foundation,stands, co-ordination during execution, rendering necessary guidance for execution, supervision, testing,commissioning and startup of above mentioned VRF/VRV by OEM. Refrigerant topup or charge must be included in quoted price Note: The civil foundations reqd shall be made by the tenderer 32 HP Make:VOLTAS, Toshiba,Mitisubishi Electric,Daikin,O'General,LG,SAMSUNG
Supply, installation, testing and commissioning of Variable Refrigerant Flow modular type air-conditioning system suitable for Cooling & Heating both by multiple scroll/DC Twin rotary compressor controlled by individual inverters for each compressor complete with indoor and outdoor units with individual wired and wireless /wired remote controller for indoor units and centralized controller, interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, control cabling and fittings etc. as per details given in specifications and having following items. The out door units shall be suitable for 3 phase 4 wire system, 415V + 10 %, 50 Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply. Outdoor Units Supply, installation, testing & commissioning of Modular type outdoor units equipped with highly efficient multiple scroll/ DC twin rotary compressors(OEM manufactured) fully inverter controlled (individual inverter for each compressor) i.e. changes its speed in accordance to the variation in cooling loads, special heat exchanger, low noise condenser fan, auto check function for connection error, auto address setting and capacity as mentioned below including all hardware & accessories & including full charging of R-410A refrigerant gas complete i/c powder coating complete as per specifications. The units should be with necessary weather protection coating. The coating should be done before bringing the units to site. Out door units shall be provided with MS stand of suitable size duly painted with corrosion resistant paint suitable for outdoor application. Each ODU in the module or individual unit should have multiple compressors for better redundancy. All the units shall be provided with built-in microprocessor control panel, for automatic operation and capacity control. All compressor shall have inverter technology i.e. outdoor units shall have all inverter based compressor. The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identicle of the ODU. Each ODU wheather used individually or used to make module should have multiple compresors. All Bidders has to submit the test certificates along with the delivery of VRF/VRV Units at site. A draft Format of the same need to be submitted along with in the Technical Bid. Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP at 50% Load to be >=5.2 at 35 Deg Ambient ConditionsInsurance of Units ,Unloading at site, placement of Oudoor Units on the foundation,stands, co-ordination during execution, rendering necessary guidance for execution, supervision, testing,commissioning and startup of above mentioned VRF/VRV by OEM. Refrigerant topup or charge must be included in quoted price Note: The civil foundations reqd shall be made by the tenderer 40 HP Make:VOLTAS, Toshiba,Mitisubishi Electric,Daikin,O'General,LG,SAMSUNG
VRV/VRF Indoor Units Supply, installation, testing and commissioning of below mentioned capacity Ductable/Casettes type Indoor air conditioners complete with fan and fan motor, inter connecting it with refrigerant piping, insulation , cabling, earthing, necessary galvanized steel supports etc. as per specification and drawing. The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for 21 Kg/cm2. Indoor units shall have a wired remote control. They shall be operated through from the wired remote control from the respective locations. Corded Remotes are seperately payable. The Drain pump as a standard accessory and shall be included in the price of units for Cassette /Ductable Acs and should have built in provision of Fresh AiDuctable ACs3.0 TR
VRV/VRF Indoor Units Supply, installation, testing and commissioning of below mentioned capacity Ductable/Casettes type Indoor air conditioners complete with fan and fan motor, inter connecting it with refrigerant piping, insulation , cabling, earthing, necessary galvanized steel supports etc. as per specification and drawing. The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for 21 Kg/cm2. Indoor units shall have a wired remote control. They shall be operated through from the wired remote control from the respective locations. Corded Remotes are seperately payable. The Drain pump as a standard accessory and shall be included in the price of units for Cassette /Ductable Acs and should have built in provision of Fresh AiDuctable Acs 4.0 TR
VRV/VRF Indoor Units Supply, installation, testing and commissioning of below mentioned capacity Ductable/Casettes type Indoor air conditioners complete with fan and fan motor, inter connecting it with refrigerant piping, insulation , cabling, earthing, necessary galvanized steel supports etc. as per specification and drawing. The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for 21 Kg/cm2. Indoor units shall have a wired remote control. They shall be operated through from the wired remote control from the respective locations. Corded Remotes are seperately payable. The Drain pump as a standard accessory and shall be included in the price of units for Cassette /Ductable Acs and should have built in provision of Fresh AiFour Way Cassette Acs along with its Grill Panel 2.5 TR
VRV/VRF Indoor Units Supply, installation, testing and commissioning of below mentioned capacity Ductable/Casettes type Indoor air conditioners complete with fan and fan motor, inter connecting it with refrigerant piping, insulation , cabling, earthing, necessary galvanized steel supports etc. as per specification and drawing. The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for 21 Kg/cm2. Indoor units shall have a wired remote control. They shall be operated through from the wired remote control from the respective locations. Corded Remotes are seperately payable. The Drain pump as a standard accessory and shall be included in the price of units for Cassette /Ductable Acs and should have built in provision of Fresh AiFour Way Cassette Acs along with its Grill Panel 3.0 TR
VRV/VRF Indoor Units Supply, installation, testing and commissioning of below mentioned capacity Ductable/Casettes type Indoor air conditioners complete with fan and fan motor, inter connecting it with refrigerant piping, insulation , cabling, earthing, necessary galvanized steel supports etc. as per specification and drawing. The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for 21 Kg/cm2. Indoor units shall have a wired remote control. They shall be operated through from the wired remote control from the respective locations. Corded Remotes are seperately payable. The Drain pump as a standard accessory and shall be included in the price of units for Cassette /Ductable Acs and should have built in provision of Fresh AiTwo Way Cassette Acs along with its Grill Panel 2.0 TR
VRV/VRF Indoor Units Supply, installation, testing and commissioning of below mentioned capacity Ductable/Casettes type Indoor air conditioners complete with fan and fan motor, inter connecting it with refrigerant piping, insulation , cabling, earthing, necessary galvanized steel supports etc. as per specification and drawing. The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for 21 Kg/cm2. Indoor units shall have a wired remote control. They shall be operated through from the wired remote control from the respective locations. Corded Remotes are seperately payable. The Drain pump as a standard accessory and shall be included in the price of units for Cassette /Ductable Acs and should have built in provision of Fresh Ai Hiwall Units 1.5 TR Make: VOLTAS,Toshiba,Mitisubishi Electric,Daikin,O'General,LG,SAMSUNG
VRV/VRF Indoor Units Supply, installation, testing and commissioning of below mentioned capacity Ductable/Casettes type Indoor air conditioners complete with fan and fan motor, inter connecting it with refrigerant piping, insulation , cabling, earthing, necessary galvanized steel supports etc. as per specification and drawing. The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for 21 Kg/cm2. Indoor units shall have a wired remote control. They shall be operated through from the wired remote control from the respective locations. Corded Remotes are seperately payable. The Drain pump as a standard accessory and shall be included in the price of units for Cassette /Ductable Acs and should have built in provision of Fresh Ai Hiwall Units 2.0 TR Make: VOLTAS,Toshiba,Mitisubishi Electric,Daikin,O'General,LG,SAMSUNG
Providing and fixing of Corded remote controls with cord for ductable/Cassette Acs
Providing and fixing of Cordless remote controls
Providing, Fixing & Running Centralized Controller for all VRV/VRF / Indoor /Outdoor Units Make: VOLTAS,Toshiba,Mitisubishi Electric,Daikin,O'General,LG,SAMSUNG
Supply Installation, Testing and commissioning of fittings Ref Net / T / Y-joints etc as per specifications.
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF //Ductable/Split system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system.41.3 mm OD (insulation = 19mm)Make : Rajco/Mandev/Totaline
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF //Ductable/Split system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system. 38.2 mm OD (insulation = 19mm)Make : Rajco/Mandev/Totaline
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF //Ductable/Split system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system.34.9 mm OD (insulation = 19mm)Make : Rajco/Mandev/Totaline
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF //Ductable/Split system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system. 31.8 mm OD (insulation = 19mm)Make : Rajco/Mandev/Totaline
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF //Ductable/Split system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system. 28.6 mm OD (insulation = 19mm)Make : Rajco/Mandev/Totaline
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF //Ductable/Split system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system. 25.4 mm OD (insulation = 19mm)Make : Rajco/Mandev/Totaline
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF //Ductable/Split system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system. 22.2 mm OD (insulation = 19mm)Make : Rajco/Mandev/Totaline
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF //Ductable/Split system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system. 19.1 mm OD (insulation = 13 mm)Make : Rajco/Mandev/Totaline
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF //Ductable/Split system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system. 15.9 mm OD (insulation = 13 mm) Make : Rajco/Mandev/Totaline
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF //Ductable/Split system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system. 12.7 mm OD (insulation = 13 mm) Make : Rajco/Mandev/Totaline
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF //Ductable/Split system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system. 9.5 mm OD (insulation = 13mm) Make : Rajco/Mandev/Totaline
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF //Ductable/Split system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system.6.4 mm OD (insulation = 13 mm) Make : Rajco/Mandev/Totaline
SITC of Factory/Site fabricated GSS Ducting complete with hanging arrangement of fasteners, GI threaded rods etc. 24 G (0.63 MM) (Make: Eco Duct/Zeco(Sheet Make: Tata, Sail,Jindal)
SITC of Nitrile rubber class-O/Closed cell XLPE Fire retardant insulation 9 mm thick pasted on the outer surface of duct with suitable adhesive complete in all respects with Nitrile tapes.
SITC of Acoustic lining of the supply duct with 10 mm thick Accosound Nitrile board with suitable adhesive to be pasted inside of the Plenum duct complete in all respects 10 mm thickness accosound Board
SITC of Aluminium extruded powder coated Grills for supply & return air w/o vcd Make:Tristar/Caryaire/Ravistar/Uniaire
SITC of Aluminium powder coated Diffuser for supply & return air w/o vcd Make:Tristar/Caryaire/Ravistar/Uniaire
Supply, installation, testing & commissioning of GI Collar dampers
Supply, installation, testing & commissioning of GI Duct dampers
Supply, installation, testing & commissioning of CBRI approved fusible link Fire duct Dampers for at least 90 min fire rating as per UL555:1955 Specifications without Sleeve
Supplying & fixing of fresh air intake louvers with bird screen dampers along with pre Filter (Aluminum extruded only)
Providing UPVC pipes of various sizes for condensed water drainage from Indoor unit to nearest disposal point in toilet/ outside rain water harvesting system as approved by architect/consultant/Client All necessary civil works like cutting & chasing of walls/floor/ glass etc. and make them good thereof 32 MM DIA Make : Diplast/Polypack/Supreme
Providing UPVC pipes of various sizes for condensed water drainage from Indoor unit to nearest disposal point in toilet/ outside rain water harvesting system as approved by architect/consultant/Client All necessary civil works like cutting & chasing of walls/floor/ glass etc. and make them good thereof 25 MM DIA Make : Diplast/Polypack/Supreme
Providing & fixing control cum transmission wiring/ Control Cabling of 2 core x 1.5sq. mm copper in suitable conduits between indoor and out door unit & indoor unit & its remote controller. Make : Havell's,Eko,Finolex,Polycab
Providing & Charging of Refrigerant of R 410a for Top up in Piping and Outdoor/Indoor Units of VRV/VRF system. Make : Honeywell ,Dew Point
Providing and fixing of perforated type GI Cable Tray (1.5 mm thick) for exposed Running Copper Refrigerant Piping of of Following Sizes including nut bolts G.I Thread rods Complete in all Respect 50mm(H) x 450mm(W) x50 mm(H)
Providing and fixing of perforated type GI Cable Tray (1.5 mm thick) for exposed Running Copper Refrigerant Piping of of Following Sizes including nut bolts G.I Thread rods Complete in all Respect 50mm(H) x 300mm(W) x 50 mm(H).
CABINET /IN Line CENTRIFUGAL FANS FOR FRESH AIR Supply, Installation, Testing & commissioning of Ceiling Suspended Inline type fans. Fans shall be of Low noise direct driven type with all accessories etc.complete as per specifications & drawings.(Installation of fans shall mean unloading, lifting-shifting, positioning,levelling & installation in place) Make : Edgetech ,Zeco,Waves,Carrier 1500 CFM ,30 mm Static
Providing & Fixing Underdeck Insulation with 50 mm thick TF Quality EPS of Density 20 Kg/M3 fixed to slab with good quality Black CPRX Compound. 28Gwirenet shall be tightened arround insulation so as avoid any kind of sagging, Ends of net shall be overlapping at least 25mm. Overlaps shall be screwed with galvanized screws to avoid rusting
Bidder Name
Amount
RAVI PARKASH CONTRACTOR(GSTN-06AJMPP2964K1ZN)
GODARA CONSTRUCTION COMPANY(GSTN-06AAGFG1005M1ZO)
Satish Kumar Gupta Contractor(GSTN-NA)
SUNIL SANGWAN(GSTN-NA)
NAFE SINGH CONTRACTOR(GSTN-NA)
MS B.S.Construction Company(GSTN-NA)
SUNIL SANGWAN
GODARA CONSTRUCTION COMPANY
RAVI PARKASH CONTRACTOR
Satish Kumar Gupta Contractor
NAFE SINGH CONTRACTOR
NAFE SINGH CONTRACTOR
GODARA CONSTRUCTION COMPANY
SUNIL SANGWAN
Satish Kumar Gupta Contractor
MS B.S.Construction Company
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_206581.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .