| 1 | L1₹14.0 LAccepted-AOC 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹15.0 L+₹97,830 (6.99%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹15.0 L+₹1.0 L (7.39%)Rejected-Finance AT ROAD HATIALI PO CHABUA DIST DIBRUGARH ASSAM 786184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹15.2 L+₹1.2 L (8.44%)Rejected-Finance MES TINALI PO CHABUA DISTT DIBRUGARH ASSAM 84 | CHABUA | DIBRUGARH | ASSAM | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹15.3 L+₹1.3 L (9.53%)Rejected-Finance AT ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹13.5 L
EMD Value
₹28,000
Closing Date
19 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) CHABUA
GE(AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUGARH, ASSAM-786102
REPAIR/MAINTENANCE OF EXTERNAL WATER SUPPLY AND ALLIED WORKS AT BALIJAN STN UNDER GE(AF) CHABUA
2021_MES_463587_1
346/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE(AF) CHABUA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE(AF) CHABUA
₹28,000
Yes
10 Sept 2021
29 Jul 2021
21 Aug 2021
29 Jul 2021
19 Aug 2021
12 Aug 2021
30 Jul 2021 - 6 Aug 2021
60 days
Amount
Opening of top and bottom cover of pressure feed type filtration plants 5000 to 10000 gallons capacity per hours, taking out old filter media including old strainer etc and removing and disposing at nearest dump all as directed by Engineer-in-Charge.
Scraping and cleaning the surface bed, inner and outer surfaces of the IR plant shell for complete removal of scales, rust, old paint etc and painting with two coats of anti corrosive bituminous lead free paint suitable for storage of potable water (for internal surfaces) and two coats of aluminium paint for external surfaces and two coats of synthetic enamel paint with connected valves, frontal pipes as per colour code and write (size of lettering 65 mm height) on indicated space ie. DATE OF CHANGING FILTER MEDIA............., CAPACITY OF TANK ...........,MES NO ............,SM NO ........etc.) in white synthetic enamel paint over black back ground synthetic enamel paint of 10000 gallons capacity filtration plant complete all as directed.
Supply and fixing of PP/LDPE double deck type PP(3/8" or 1/2") strainer suitable for filtration plant, complete all as specified and as directed.
Supplying and charging in layers special coarse sand suitable for use in filtration plant of following sizes, complete all as specified and as directed.:-
(a) 1/8" x 1/16" mesh
(b) 1/16" x 1/24" mesh
Supplying and charging in layers new washed, cleaned, dust free graded gravels filter media suitable for use in filtration plant of the following size, complete all as specified and as directed.:-
(a) Gravel of grading 20 mm to 40 mm
(b) Gravel of grading 12 mm to 20 mm
(c) Gravel of grading 6 mm to 12 mm
(d) Gravel of grading 3 mm to 6 mm
Note:- (i) Before charging of filter media contractor shall carry out raw water testing for all parameters. (ii) After completion of the change of filter media the treated water test for all parameters with in 10 days to send the water for testing. (iii) All testing connected with water, testing from Govt approved laboratory. (iv) The water testing cost is deemed to be included in rates quoted.
Supply and charging in layers Manganese dioxide(MnO2) of approximate sizes 20 mm to 25 mm containing at least 65% of manganese, suitable for use in filtration plant complete all as specified and as directed by Engineer-in-Charge. NOTE:- Samples of raw material (MNO2) should be got tested in Govt approved laboratory before using in the oxidation chamber for determining the MNO2 purity, which shall not be less than 65% ((MNO2 contents minimum 65% purity), testing charge for the same is deemed to be included in the cost quoted by the contractor.
Supply and fixing in repairs diaphragm valve of 80 mm bore including taking out old diaphragm valve with, complete all as specified and as directed.
Cleaning, desludging and removing of all scales and dirt from OH Pressed Steel Tank of capacity 9600 gallons installed at height of 40 feet staging and write (size of lettering 75 mm height) on indicated space at a height 3.5 mtr from ground level (ie. DATE OF CLEANING................, CAPACITY OF TANK ..................etc.) in black synthetic paint over white synthetic enamel paint all as directed and specified. NOTE : (a) Cost of staging/working platform involved shall be deemed to be included in the unit rate quoted. (b) consumption of bleaching powder for cleaning of each tank shall not be less than 12 Kg (c) Maximum two times cleaning of each tank in entire C.A. period. (Measured separately each time)
Construction of brick masonry valve pit / chamber of internal dimension 90 cm x 90 cm x 90 cm depth with sub class 'B' old size bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6 mm angle iron 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary breaking of the existing old chamber, excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m, complete all as specified and as directed by Engr-in-Charge.
All as per item No. 9 here-in-before above but valve pit chamber of internal dimension size 60 x 60 x 60 cm, complete all as specified and as directed by Engr-in-Charge..
Attending emergency breakdown of sewage/water supply installation where directed, taking out defective submersible pump set of capacity 7.5HP/10HP/15HP/ 16.5HP incl column pipes from bore well, transporting pump set from site to work shop for repairs and back and lowering the pump set incl column pipes and making water and electric connection as per existing for running of pump motors complete all as directed by Engr-in-Charge. Note:- Spare Parts shall be measured & paid under relevant items.
Supply only Upper housing 80 mm for 10 HP Submersible pump & motor (water supply & sewage), complete all as specified and as directed.
Supply only Upper housing 80 mm for 15 HP Submersible pump & motor (water supply & sewage), complete all as specified and as directed.
Supply only Upper housing 80 mm for 20 HP Submersible pump & motor (water supply & sewage),complete all as specified and as directed.
Supply only Mitchel thrust bearing gunmetal for 15 HP Submersible pump & motor (water supply & sewage),complete all as specified and as directed.
Supply only Mitchel thrust bearing gunmetal V6 for 20 HP Submersible pump & motor (water supply & sewage),complete all as specified and as directed.
Supply only Rotor for ,15 HP Submersible pump & motor (water supply & sewage),complete all as specified and as directed.
Supply only Intermediate piece for 10 HP Submersible pump & motor (water supply & sewage) ,complete all as specified and as directed.
Supply only Gun metal impeller 140 mm for 15 HP Submersible pump & motor (water supply & sewage) ,complete all as specified and as directed.
Supply only Pump NRV 200 mm inner dia for 15/20 HP Submersible pump & motor (water supply & sewage),complete all as specified and as directed.
Supply only Pump shaft gunmetal for 15 HP Submersible pump & motor (water supply & sewage),complete all as specified and as directed.
Rewinding of stator of submersible motor for 15/20 HP capacity with water proof insulated copper wire of existing gauge to achieve the specified/required RPM including taking out old unserviceable winding, complete all as specified and as directed
All as per item No-22 here in before but 0.5 HP capacity, complete all as specified and as directed.
Supply, fiixing, testing and commissioning pressed steel plates of size 1.25 m x 1.25 m x 6 mm thick on existing PS OH Tank installed on 40' to 50' height staging with required number of holes on the plates according to existing plate of PS tank including all necessary joining materials i.e. lead wire, tape, lead wool, gasket, putty/jointing compound, new machine made bolts, nuts, washers, MS cleat etc of required size to make the joining portion absolutely leak proof complete including painting of two coats of lead free black bituminous paint suitable for storage of drinking water internally and two coats of Aluminum paint over one coat of red oxide zink chrome primer externally including preparation of surface and refixing/reconnecting of existing pipe line connection, including taking down old u/s plates complete all as specified and as directed. Note:- cost of staging/working platform involved shall be deemed to be included in the unit rate quoted.
Repairing of joints of plates in position by loosing the jointing bolts, unscrewing jointing materials such as lead wire/tapes, lead wool gasket, bituminous compound and replacing with new matching made bolts, nuts, washers bituminous compound suitable for potable water and MS cleats wherever required complete all as specified and as directed by Engr-in-Charge.
S&F in repairs of 3 mm thick MS sheet cover plate with locking arrangement fixed at any position of PS overhead tank installed on 40' to 50' height staging including necessary welding, jointing materials to make the jointing portion absolutely leak proof complete all as specified and as directed.
Repairs to existing 9600 Gallons water tank installed on 40/50 feet height staging by disconnecting pipe connection carefully taking down the existing PS plates by cutting welding, nut bolts etc and refixing the same with existing serviceable plate/new plate of size 1.25 m x 1.25 m x 6 mm (PS plates refixed/new shall measured and paid separately under respective items), painting the tank after repair work with 2 coats of aluminum paint outside the tank incl staging (staging painted by black synthetic enamel paint both side) top to bottom and two coats of lead free black bituminous paint inside the tank (suitable for storage of drinking water) and scraping smoothly by scraper & sand paper to remove all loose paints, scales, rust and restoration of pipe lines, lettering with white synthetic enamel paint over the black painted surfaces of indicated plates (i.e. capacity of tank, date of cleaning etc) complete all as directed. Note:- (a) The cost for the refitting of pipeline connections in new or old positions with necessary GI fittings, flanges and jointing materials etc includes in the unit rate quoted by the firm to make the joint leak proof. (b) Plates shall be measured and paid separately. (c) The PS tank shall be painted with two coats of aluminum paint out side incl staging and two coats of black bituminous (lead free) paint inside complete, Cost of staging/working platform & painting (inside / outside) involved shall be deemed to be included in the unit rate quoted.
S&F steel water tubing medium grade galvanised, with all fittings laid in trenches of size 25 mm bore complete all as directed. Note:- Excavation and earth work if required will be measured and paid separately.
All as per item 28 but 40mm bore complete all specified and as directed.
All as per item 28 but 50mm bore complete all specified and as directed.
All as per item 28 but 80mm bore complete all specified and as directed.
All as per item 28 but 100mm bore complete all specified and as directed.
S&F steel water tubing medium grade galvanised, with all fittings to walls and ceilings of size 15 mm bore complete all specified and as directed.
All as per item 33 but 20mm bore complete all specified and as directed.
All as per item 33 but 25mm bore complete all specified and as directed.
All as per item 33 but 40mm bore complete all specified and as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or sch of credit or removal to store 15 mm bore complete all specified and as directed. Note:- Excavation and earth work if required will be measured and paid separately.
All as per item 37 but 20mm bore complete all specified and as directed.
All as per item 37 but 25mm bore complete all specified and as directed.
All as per item 37 but 40 to 50 mm bore complete all specified and as directed.
All as per item 37 but 80 to 100mm bore complete all specified and as directed.
Supply and fixing in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 20mm bore pipe complete all specified and as directed.
All as per item 42 but for 25mm bore pipe complete all specified and as directed.
All as per item 42 but for 40mm bore pipe complete all specified and as directed.
All as per item 42 but for 50mm bore pipe complete all specified and as directed.
Supply and fixing in repairs sluice valve with cast iron body and gun metal/steel spindle and hand operated iron wheel, both ends flanged and drilled including nuts, bolts, washers and gaskets, PN 1.6 ISI Marked of 80mm bore size all as specified and directed by Engr-in-Charge.
All as per item 46 above but for 100mm bore complete all specified and as directed.
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
S & F in repairs MCCB 4 pole,415 volt 160 Amps with breaking capacity 36 kA, 415 V, 50 Hz, complete all specified and as directed.
S & F repairs MCCB 4 pole,415 volt 200 Amps with breaking capacity 36 kA, 415 V, 50 Hz, complete all specified and as directed.
S & F repairs MCCB 4 pole,415 volt 250 Amps with breaking capacity 36 kA, 415 V, 50 Hz, complete all specified and as directed.
S & F repairs MCCB 4 pole,415 volt 400 Amps with breaking capacity 36 kA, 415 V, 50 Hz, complete all specified and as directed.
S & F in repairs MCB TP 63 Amps, 415 V, complete all specified and as directed.
S & F in repairs MCB TP upto 32 amps 415 volts B series complete all specified and as directed.
S & F in repairs MCB SP 'B' series 6 to 40 Amps, 240 V complete all specified and as directed.
Taking up GI water mains from trenches for repair/rectification of leakage of GI water line of sizes 15 to 25 mm dia including bailing out water, mud etc and relaying the same after repair in position and testing of leakage complete all as specified and directed by Engineer-in-Charge. Note:- Excavation & earthwork will be measured and paid for separately but GI fitting and jointing material deemed to be included in the quoted rate.
Taking up GI water mains from trenches/wall for repair/rectification of leakage of GI water line of sizes 40 to 50 mm dia including bailing out water, mud etc and relaying the same after repair in position and testing of leakage complete all as specified and directed by Engineer-in-Charge. Note:- Excavation & earthwork will be measured and paid for separately but GI fitting and jointing material deemed to be included in the quoted rate.
Taking up GI water mains from trenches/wall for repair/rectification of leakage of GI water line of sizes 80 to 100 mm dia including bailing out water, mud etc and relaying the same after repair in position and testing of leakage complete all as specified and directed by Engineer-in-Charge. Note:- Excavation & earthwork will be measured and paid for separately but GI fitting and jointing material deemed to be included in the quoted rate.
S & F in repairs power factor improvement static condenser (capacitors) of required capacity, complete all as specified and directed.
S&F in repairs Fully Automatic Star Delta Starter in sheet steel Enclosure with contactor & Pneumatic timers, 3 phase 415 volts, Relay range (18-25 Amps) suitable of 15 HP pump, and connection, testing, complete all as specified and as directed by Engr-in-charge.
S&F in repairs Fully Automatic Star Delta Starter in sheet steel Enclosure with contactor & Pneumatic timers, 3 phase 415 volts, Relay range (23-32 Amps) suitable of 20 HP pump , and connection , testing ,complete all as specified and as directed by Engr-in-charge.
S & F in repair's relay for automatic star delta submersible pump starter overload relay, range (8-22), 415 volts complete all as specified and as directed.
S & F in repair's relay for automatic star delta submersible pump starter overload relay range (16-44), 415 volts complete all as specified and as directed.
Supply and fixing in repair power contactors 3 pole rating 25 Amps, with auxiliary contact 01 NO 01 NC complete all as directed by the Engineer-in-Charge.
Supply and fixing in repair power contactors 3 pole rating 30 Amps, with auxiliary contact 01 NO 01 NC complete al as directed by the Engineer-in-Charge.
Supply and fixing in repair power contactors 3 pole rating 30 Amps, with auxiliary contact 01 NO 01 NC complete all as directed by the Engineer-in-Charge.
Supply and fixing in repair power contactors 3 pole rating 32 Amps, with auxiliary contact 01 NO 01 NC complete all as directed by the Engineer-in-Charge.
S & F in repairs APFC Relays with auto set function having 7 + 1 steps 8 stage suitable for 415 Volts incl necessary connections all as directed.
S & F in repairs front mounted add on aux contact block 1 NO + 1 NC suitable for power contactor MNX 45 all as directed .
S & F in repairs side mounted add on aux contact block 1 NO + 1 NC suitable for power contactor MNX 45 all as directed .
S & F in repairs modular contact NO block suitable for capacitor bank all as directed.
S & F in repairs modular contact NC block suitable for capacitor bank all as directed.
Supply only MS handle for hand pump, complete all as specified and as directed.
Supply only cast iron hand pump set complete all as specified and as directed.
Supply and fix in repair vertical check complete all as specified and as directed.
S & F in repairs electronic protection Relays overload, single phasing, current unbalance, under current complete all as specified and directed.
S & F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.
S & F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
Supply and fixing in repair digital voltmeter, ranging from 0 to 500 Volts, including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge.
Supply and fixing in repair digital ammeter, ranging from 0 to 400 Amps (with CT of suitable ratio), including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge.
S & F in repairs Indicator Lamps (LED type) including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge.
Schedule of Credit
M/s PRABIR ENTERPRISE
D.D Construction
M/S DURGA CONSTRUCTION & CO
M/S MAHATO ENTERPRISE
STANDARD ELECTRIC WINDERS
FREEZCON
MAA COMMUNICATION
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .